Loading...
HomeMy WebLinkAbout11/13/2002 P&Z Packet• • • btlA Vic; CITY OF LINO LAKES PLANNING & ZONING BOARD MEETING Wednesday, November 13, 2002 6:30 p.m. City Council Chambers (Scheduled to be Televised on Ch. 16) AGENDA I. CALL TO ORDER AND ROLL CALL II. APPROVAL OF AGENDA III. APPROVAL OF MINUTES: October 9, 2002 IV. OPEN MIKE V. ACTION ITEMS A. Ray Benkler, Car Wash, XXX Lake Drive, Conditional Use Permit and Site Plan Review, Bob Kirmis (NAC) B. Gordon Johnson, Udor, 500 Apollo Drive, Site Plan Review, Tanda Gretz C. CONTINUED PUBLIC HEARING, Gary Uhde, Behm's Century Farm 6th — 10th Additions, South of Main St. & North of Carl St. - Section 7, Preliminary Plat, Rezone, MUSA Allocation, Jeff Smyser - NO ADDITIONAL INFORMATION — CONTINUE TO DECEMBER MEETING VI. DISCUSSION ITEMS A. None VII. ADJOURN • CITY OF LINO LAKES PLANNING & ZONING BOARD MINUTES DATE TIME STARTED TIME ENDED MEMBERS PRESENT MEMBERS ABSENT STAFF PRESENT • September 11, 2002 : 6:37 P.M. 8:16 P.M. : Corson, Hyden, Lyden, Schaps and Zych. : Lane and Rafferty. : Jeff Smyser; Tanda Gretz; James Studenski I. CALL TO ORDER AND ROLL CALL Chair Schaps called the Lino Lakes Planning and Zoning Board meeting to order at 6:37 p.m., September 11, 2002. Chair Schaps requested a moment of silence in remembrance of the victims and their families of September 11, 2001. II. APPROVAL OF AGENDA The agenda was approved. III. APPROVAL OF MINUTES — August 14, 2002 Mr. Lyden made a MOTION to approve the minutes of the August 14, 2002, meeting of the Lino Lakes Planning and Zoning Board, and was supported by Mr. Hyden. Motion carried 3 -0 -1 (Corson abstained). IV. OPEN MIKE Chair Schaps declared open mike open at 6:39 p.m. David McDonald, 790 Lois Lane, asked for clarification regarding plans he had for an addition that he wanted to put on. He presented a diagram of his proposed plans for the Board's review. He asked for the Board's suggestions and recommendations. Chair Schaps stated he has had conversations with Mr. McDonald and Mr. Smyser regarding the expansion of his business, and asked if Mr. McDonald changed the wall construction, would it still be considered a pole barn. Mr. Smyser replied before Mr. APPROVED MINUTES • Planning & Zoning Board September 11, 2002 Page 2 McDonald built onto this building, it was a pole barn and he told Mr. McDonald as long as it did not fulfill the definition of a pole barn, there would be no problem. He stated as long as the building did not have metal skin and poles in the ground, the City would not view this as a pole barn. However, he would still be required to meet the other Code requirements. He indicated this expansion was a good idea, as long as it was not a pole barn construction. Mr. Lyden asked if the definition of a pole barn was the material that was used on the outside. Mr. Smyser replied that was one of the factors. Mr. Lyden pointed out the City should not have a problem with the metal roof, considering the City Hall had a metal roof. Chair Schaps asked if the building inspector could look at this to determine if it was a pole barn. Mr. Smyser replied he had checked with the building inspector, and the building inspector agreed that as long as there were not both poles and metal skin on the building, it was not a pole barn. Mr. McDonald noted on the surveyor's map he had received when he added the last addition on, it was noted that at some point in the future, he was intending on adding onto the back of the building. Chair Schaps informed Mr. McDonald to work closely with staff and submit a commercial site and building plan. Mr. Lyden made a MOTION to close Open Mike at 6:50 p.m., and was supported by Mr. Hyden. Motion carried 4 -0. V. ACTION ITEMS A. Laraine Cardarelli & Craig Severson, 82XX W. Rondeau Lake Rd., Minor Subdivision Staff explained Ms. Cardarelli and Mr. Severson are applying for a Minor Subdivision of approximately 32 acres of land, zoned Rural, on the 82XX block of West Rondeau Lake Road. The applicant would like to create two lots: one lot of 21.69 acres and one lot of 10.43 acres. Staff presented its analysis by explaining the Certificate of Survey shows the proposed division of the 32 -acre parcel. Parcel A, 21.69 acres, contains 22 % upland. Parcel B, 10.43 acres, does not have upland delineated on the survey, but as aerial photos show the land to have been in agriculture (and now in pasture), meeting the 20% minimum upland requirement does not appear to be an issue. • Staff explained the minimum lot size for property in a Rural zone is ten acres. Both of the two proposed lots will meet this requirement. APPROVED MINUTES • • • Planning & Zoning Board September 11, 2002 Page 3 Staff stated the minimum lot width for property in a Rural zone is 330 feet, and both lots meet this requirement. In addition, both lots will have full frontage on a road, as required under the Lino Lakes Subdivision Ordinance, Section 1008.08, subdiv. 6, which states that "all lots shall abut for their full frontage on a publicly dedicated street." Staff noted all created lots are required to include drainage and utility easements. The applicant will need to dedicate drainage and utility easements to the City in accordance with Lino Lakes Subdivision Ordinance Section 1001.08, subdiv. 4. Such easements shall be five feet in width along side property lines, ten feet in width along front and rear property lines, and cover all ponding and wetland areas. In addition, street right -of -way dedication will be required according to the Lino Lakes Subdivision Ordinance Section 1001.08, subdiv. 10. Staff stated it should be noted as a point of information that there is an existing 30 -foot easement between the proposed parcels that serves as a driveway to an existing lot of record ( "Parcel C ") that lies between the two proposed lots on their southern boundary. This easement is not held by the City, but presumably exists solely for access purposes for Parcel C. Staff indicated Lino Lakes City Ordinance Section 3, subd. 3.B.2.b states that parcels located within a zoning district that carries a minimum lot size of 10 acres must have a minimum of 20% buildable /upland area. Both of the proposed lots meet this requirement. Staff stated soils tests confirm that there are soils on both the proposed parcels capable of accommodating a septic system, with enough room for both primary and secondary sites. In conclusion, staff noted the proposed Minor Subdivision would result in two lots: Parcel A of 21.69 acres and Parcel B of 10.43 acres. Both proposed lots would meet all minimum lot requirements, as established under the Lino Lakes City Code. As a result, staff would recommend approval of the Minor Subdivision with the following conditions: 1.) A park dedication fee of $1,665 to be paid prior to the certification and recording of the Minor Subdivision. 2.) The applicant shall dedicate to the City drainage and utility easements measuring ten feet in width along the front and rear property lines, five feet in width along side property lines, and covering all ponding and wetland areas. Such dedication shall be in the form of a Quit Claim Deed, per the City attorney, to be submitted prior to the certification and recording of the Minor Subdivision. 3.) The applicant shall dedicate to the City a 33 -foot wide permanent public right -of -way adjacent to West Rondeau Lake Road. Such dedication shall be in the form of a Quit Claim Deed, per the City attorney, to be submitted prior to the certification and recording of the Minor Subdivision. Chair Schaps invited applicant to make comment. Applicants did not make comments. APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 4 Mr. Lyden made a MOTION to approve Laraine Cardarelli & Craig Severson, 82XX W. Rondeau Lake Rd., Minor Subdivision, subject to staff's recommendations and conditions as outlined in staff's report. The motion was supported by Mr. Hyden. Motion carried 4 -0. B. Michael & Laura Sullivan, 8065 Wood Duck Trail, Variance Staff stated Michael and Laura Sullivan reside at 8065 Wood Duck Trail, a 2.89 acre lot that is zoned Rural. The Sullivans have applied for a Variance in order that they may locate a detached garage closer to the front lot line than the principle building. Section 3, subdiv. 4.D.1.c of the Lino Lakes Zoning Ordinance states that "no detached accessory structure shall be closer to the front lot line than the principal building or its attached garage." Staff noted the Sullivans home is sited 98 feet back from Wood Duck Trail. Wood Duck Trail is classed as a minor collector street, which has a setback requirement of 40 feet. Staff indicated the property currently does not have a garage on site, although there is a 12' X 16' shed located to the northwest of the house. The Lino Lakes Zoning Ordinance, Section 5, subdiv. 1.C.3, states "all dwellings shall have a double garage." Staff stated Section 3, subdiv. 4.D.1.c states "no detached accessory structure shall be closer to the front lot line than the principle building or its attached garage." Staff indicated Section 3, subdiv. 4.D.8.d allows for 3,600 sq.ft. of accessory buildings, and up to two detached accessory buildings for a property of this size and zone. Staff indicated to satisfy ordinance requirements, a detached garage would have to be parallel with, or behind, the front line of the house. This is problematic on this site for three reasons. First, the septic drain field is located approximately 24 feet to the south of the house, with the septic tank located southeast of the house approximately the same distance. Second, the well is located to the north of the house approximately 25 feet. Thirdly, there is a pond located to the northwest of the house, directly in back of the current shed location. Each of these features act to preclude locating a garage in what would be a typical location next to, or behind, the house. As a result, staff stated the applicant is asking to be allowed to site a garage in a location to the side of, but in front of, the house. Such a site would put the garage closer to the street than the house, and thus violate Section 3, subdiv. 4.D.1.c of the City Zoning Ordinance. Staff noted such a location, however, would meet the required 40 -foot setback requirement from Wood Duck Lane. In addition, such a location would allow for the construction of a double garage, which the site currently does not have, but is a building requirement for properties located in the Rural zone. Lastly, a 24' X 36' detached garage APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 5 • would be within the allowable size and number of accessory building allowed on a lot of this size and zone. Staff noted that at least one neighboring property contains a garage which is sited closer to the street (8025 Wood Duck Trail). Staff stated the Lino Lakes Zoning Ordinance states that "in considering all requests for variance or appeal, and in taking subsequent action, the City shall make a finding of fact: 1.) That the property in question cannot be put to a reasonable use if used under conditions allowed by the official controls. Comment: the property as a whole may be put to reasonable use, but official controls preclude the construction of a garage (which is a requirement under the Zoning Ordinance) in the only workable location that is near the house. 2.) That the plight of the landowner is due to physical circumstances unique to his property, not created by the landowner. Comment: The physical location of the septic tank, drain field, well and pond preclude siting a garage in a location which would satisfy the requirements of the Zoning Ordinance. Such a configuration of elements presents a situation unique to this property, although this situation was — at least in part — created by the (previous) landowner. 3.) That the hardship is not due to economic considerations alone, and when a reasonable use for the property exists under the terms of the ordinance. Comment: The demonstrated hardship is the lack of a garage site that would satisfy the requirements of the Zoning Ordinance. Such a hardship is not economically motivated but, rather, site driven. While such a hardship still allows for the reasonable use of the property, such a hardship does not allow the property to comply with the requirement of the Zoning Ordinance, which states that all dwellings in a Rural zone should have a double garage. 4.) That granting the variance requested will not confer on the applicant any special privilege that would be denied by this ordinance to other lands, structures, or buildings in the same district. Comment: There is no special privilege involved but, rather, a need/hardship that is site - driven. Other properties with similar site constraints would also be valid candidates for a Variance such as this one. 5.) That the proposed actions will be in keeping with the spirit and intent of the ordinance. Comment: The Lino Lakes Zoning Ordinance states that a double garage is a building requirement for property located in the Rural zone. Granting this Variance would allow the applicants to comply with this requirement. APPROVED MINUTES • Planning & Zoning Board September 11, 2002 Page 6 Staff noted this application for a Variance is driven by three site constraints: location of a septic system, well, and a pond. Each of these constraints prevent siting the proposed garage in a location next to, or behind, the house, in compliance with the Lino Lakes Zoning Ordinance. As a result, staff feels there is a demonstrated need/hardship that is site - driven and quantifiable, and so justifiable. Staff would recommend approval of the proposed Variance with the following condition: 1.) The proposed garage be placed no closer than 62 feet from Wood Duck Trail. 2.) The 10 x 10 shed is to be removed. Mr. Lyden asked what was the number of accessory buildings. Ms. Gretz stated she believed it was two. Mr. Lyden stated when he drove out to the site, there were two sheds and asked if they were both owned by Mr. Sullivan. Chair Schaps invited applicant to make comment. Mr. Sullivan, 8065 Wood Duck Trail, replied there was a 10x10 shed that would be taken down once they got a dumpster for the construction of the proposed garage. • Chair Schaps asked if Mr. Sullivan agreed to adding the 10 x 10 shed to be removed as a part of the conditions. Mr. Sullivan replied he did agree to that requirement. Mr. Hyden made a MOTION to approve Michael & Laura Sullivan, 8065 Wood Duck Trail, Variance subject to staffs recommendations and conditions as outlined in staffs report. The motion was supported by Mr. Lyden. Motion carried 4 -0. C. Donald Lindahl, 855 Ash Street, Minor Subdivision & Variance Staff stated this item was presented at the August 14th meeting of the Planning & Zoning Board. After consideration of the issues, members voted to table the application pending additional information from the applicant. Specifically, Mr. Lindahl was asked to present alternate configurations for the proposed one -acre lot (Tract B), in hopes that it might be possible to achieve the required 330 feet of lot width/road frontage. Mr. Lindahl has presented two alternate configurations for consideration by members. Both proposals would meet the minimum lot width/road frontage requirement of 330 feet. However, as a result of meeting the width requirement, lot size then increases over the one -acre threshold. Since there are only 11 acres total to be used between the two proposed lots, such an increase in the size of proposed Tract B, then decreases the size of proposed Tract A under the 10 acres minimum requirement for property in a Rural zone. APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 7 Staff indicated Don and Faith Lindahl own 11 acres of land, zoned Rural, at 855 Ash Street. The Lindahls have applied for a Minor Subdivision and Variance from the minimum lot width requirements in order to subdivided their property. Although the minimum lot size for property in a Rural zone is 10 acres, the Lindahls are seeking to create a 10 -acre and a one -acre parcel, as allowed under Section 3, subd. 3.A.2.b.2 of the Lino Lakes City Code: "Habitable single family homes constructed prior to July 13, 1992 may reduce their lot size to a minimum of one acre if the balance of the property results in a parcel of ten acres, or is serviced by public sewer, and it can be demonstrated by means satisfactory to the City that the division will not result in ground water, soil or other contamination which may endanger the public health." Staff noted the Lindahls propose to live on the one -acre parcel containing the residence and outbuildings, and sell the remaining ten -acre parcel to their son. Staff stated t \it should be noted that the existing 11 -acre parcel was created in 1997 as part of a minor subdivision of 58.76 acres. Minutes from the meetings of both the Planning & Zoning Board and the City Council note that a further subdivision of the 11- acre parcel, such as is now being proposed, was discussed at that time. Minutes note that the applicant "had been advised that splitting off one acre with the homestead to provide an additional building site would probably not be recommended in this case." Staff presented its analysis by noting the Certificate of Survey shows the proposed division of the 11 -acre parcel. Tract B, one acre, contains the Lindahl home and outbuildings, of which .89 acres are upland; Tract A, ten acres, contains the balance of the property, of which four acres are upland. Staff indicated the minimum lot size for property in a Rural zone is ten acres. The proposed newly created lot would meet this requirement, with the balance of the property consisting of the one -acre parcel, as allowed under Section 3, subd.3.A.2.b.2. Staff noted the minimum lot width for property in a Rural zone is 330 feet. Lot width is defined as "the horizontal distance between the side lot line of a lot measured at the building setback line and parallel to the front lot line." Additionally, the Lino Lakes Subdivision Ordinance, Section 1001.08, subdiv. 6, requires that "all lots shall abut for their full frontage on a publically dedicated street." Staff stated Tract B at 155 feet, does not meet the minimum lot width requirement, and, as a result, the applicant is asking for a Variance. With less than the required 330' of lot width, then, Tract B also does not fulfill the requirement of having full frontage on a road. Staff noted Tract A is an irregularly shaped ( "C- shaped ") lot that does not meet the minimum lot width requirement in terms of contiguous road width and road frontage. Rather, the lot wraps around the one acre parcel, with 269 feet to the west of the one acre APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 8 1111 parcel and 188 feet to the east of the one acre parcel. Thus, although the proposed lot has 330' of width on a road, it is not contiguous width. Staff indicated Lino Lakes City Ordinance Section 3, subd. 3.B.1.b requires parcels requiring a minimum of 10 acres or more to have a minimum of 20% upland area. Both parcels meet this requirement: the 10 -acre parcel has four acres of upland, although this upland exists as "islands" among wetland area, and the one acre parcel is almost entirely composed of upland. Staff stated soils tests confirm that the proposed 10 -acre parcel is capable of accommodating a septic system. In addition, there is adequate room for both primary and secondary sites. The one -acre parcel already contains a septic system, with adequate room for a secondary site. Staff indicated the existing 11 -acre parcel contains a second driveway, not used by the Lindahls but existing on their property, that is the sole source of access for the neighboring property to the west, at 815 Ash Street. Without this driveway, the property at 815 would be landlocked, with no access out to Ash Street or any other road. The minor subdivision approved in 1997, which created the parcels at 815 and 855 Ash Street, required an easement agreement be drawn up for the driveway. This agreement was approved by the City attorney and recorded with Anoka County. In addition, as a further condition of approval, the driveway was approved by the Fire Chief. Staff noted the driveway is currently used primarily by the residents at 815 Ash Street, as the Lindahls have their own access drive. Further subdivision of the 11 -acre parcel would require shared use of this driveway, which may or may not pose a legal issue: the easement agreement states the easement is "for the exclusive benefit of Tracts B (855 Ash Street) and C (815 Ash Street)." Further, the agreement states that "no party may unreasonably increase the burden of the driveway and utility easement." The agreement can be amended only with the written consent of both parties. Staff stated the Lino Lakes Zoning Ordinance states that "in considering all requests for variance or peal and in taking subsequent action, the City shall make a finding of fact: 1.) That the property in question cannot be put to a reasonable use if used under conditions allowed by the official controls. Comment: The property has been, and currently is, being put to reasonable use. The applicant is simply asking for a further intensification of use. 2.) That the plight of the landowners is due to physical circumstances unique to his property, not created by the land owner. Comment: The landowner is asking for a further subdivision of his land, which he was advised "would probably not be recommended" when he first purchased his property. 3.) That the hardship is not due to economic considerations alone and when a APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 9 • reasonable use for the property exists under the terms of the ordinance. • Comment: There is no hardship demonstrated or apparent; rather the proposed lots simply do not meet the minimum lot requirements for property in a Rural zone. 4.) That granting the variance requested will not confer on the applicant any special privilege that would be denied by this ordinance to other lands, structures, or buildings in the same district. Comment: Granting a Variance without the demonstration of hardship or unique circumstances would confer upon the applicant special privilege. 5.) That the proposed actions will be in keeping with the spirit and intent of the ordinance. Comment: The proposed action would not be in keeping with the spirit and intent of the Ordinance, as Variances are to be granted only in cases where hardship /unique physical circumstances are present. Staff noted the proposed Minor Subdivision would result in two lots: Tract B would have a width of 155 feet, thus not meeting the minimum lot width requirement of 330' for property in a Rural zone, nor the requirement of full frontage on a road; Tract A would have 330' of width and road frontage, but it would not be contiguous width or frontage. Alternate configurations presented by the applicant meet the minimum lot width/road frontage, but do not meet the minimum lot size requirement of 10 acres. As a result, staff cannot recommend approval of the Minor Subdivision. Staff noted as there are no hardship issues or unique circumstances apparent on the property, staff cannot recommend approval of a Variance from the lot width requirements. Chair Schaps asked if they made the smaller lot bigger, was that the only flaw. Ms. Gretz replied that was correct. Mr. Lyden stated the reason they had minimum lot frontage was to have orderly development in the future. He noted the reality was that this was the right way to develop this property. He noted there was not going to be development around this property because there was wetland on one side and a cemetery on the other side. Chair Schaps stated in this case were would likely be no development alongside of this property. Mr. Lyden stated in his opinion the first option presented last month was the best option. Mr. Zych asked if there was a park dedication fee to be paid. Ms. Gretz replied the park dedication would be $1,685 and applicant was aware of this amount. APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 10 • Chair Schaps invited applicant to make comment. • • Don Lindahl, 855 Ash Street, stated he preferred to go back to his original plan with the one -acre. He stated that option worked the best for all of the buildings that was on the one -acre parcel. He indicated his second choice would be option 3. He stated he would want to record to reflect that the one parcel was not 10 acres so a future buyer would not have a problem obtaining a building permit. Mr. Lyden made a MOTION to approve Donald Lindahl, 855 Ash Street, with option number one as outlined in staff s report. Mr. Lyden requested Mr. Lindahl obtain some written agreement with the neighbor regarding use of the driveway. Mr. Lindahl replied all of that land would be owned by Tract A, so it would be entirely owned by the new owner, and the new owner would be informed to work out the driveway easement with the neighbor and this requirement would be made at the time the land was transferred. He noted his neighbor was very agreeable to working with this situation. Ms. Gretz requested the following three conditions: 1. Park dedication fee to be paid 2. Standard drainage and utility easements 3. Right -of -Way as required by Anoka County. The motion was supported by Mr. Corson. Motion carried 3 -1 (Hyden). D. CONTINUED PUBLIC HEARING, Gary Uhde, Behm's Century Farm 6th — 10th Additions, South of Main St. & North of Carl St. Chair Schaps reopened the public hearing at 7:20 p.m. Staff stated the P & Z continued the public hearing on this project at the August 14 meeting. There were a number of issues to be resolved. Staff noted major design issues include access and roads, parkland, potential new air park lots, air park impacts, wetlands, and future development on surrounding lands. Staff indicated the applicant submitted new plans on Wednesday, September 4. This did not allow time for staff to review and analyze the new submittals. Staff stated road access and connections are important design issues. The question of connecting Carl St. was discussed extensively at the August meeting. This is a major issue, and it affects numerous other aspects of the project and of this area of the City. APPROVED MINUTES • • Planning & Zoning Board September 11, 2002 Page 11 Staff is asking the P & Z to consider the following information and then give staff direction on whether or not Carl St. should be connected. Based on that direction, staff will work with the applicant on the design of the plat. Staff stated the applicant hired a consultant to prepare a traffic study. The study was summarized at the August meeting. At that time, staff had not had the opportunity to review the traffic study. The City Engineer now has had the applicant's traffic study analyzed. That analysis is attached (TKDA memo from Steven Elmer, August f3). Note that several assumptions and conclusions in the study may not be universally accepted. Staff noted the majority of P & Z members voiced opposition to connecting Carl St. to the new development. At the same time, most P & Z members expressed support for new air park lots that would each accommodate a home and a hanger. Staff indicated it would seem that the best way to incorporate new air park lots would be to design them to be part of the existing air park. If this is to occur, they should be connected to the existing air park lots along Carl St. If Carl St. does not connect, the new air park lots will be separated from the rest, which would seem to violate the concept of an air park "neighborhood ". Staff indicated therefore, if new air park lots are to be created with the Behm's plat, Carl St. should connect to the new plat. Staff stated existing air park lots on Carl St. are 373' deep, with widths ranging from 123' to 178' (1.1 acre to 1.5 acre). The hangers can be up to 3200 s£ The size of any new air park lots should accommodate the houses, hangers, and taxiways. Staff noted one of the options presented by the project applicant is the future creation of a road along the powerline easement to provide access to 4th Ave. and a connection between 4th Ave. and Sunset Rd. At the August meeting, discussion included the likelihood of future opposition to this connection by residents of the new Behm's neighborhood —the neighborhood that will be created by the plat under consideration. Staff believes that the opposition that will occur will most likely prevent the connecting road from being constructed. Staff indicated there are physical design issues to consider as well. The powerline easement is 90 feet wide. If a road is built along the northern edge of the easement, the powerline easement will cover the front 90 feet of the lots fronting on the road. The houses will have to be setback at least 90 feet to be out of the easement, with 90' driveways. The front yards will have high voltage powerlines crossing them. This does not seem to be a very inviting neighborhood design. Even if the paved road is offset as close as possible to the towers, at least 50 -60 feet of front yards will be under the powerline easement with the wires overhead. Staff stated since the property on which this hypothetical road is located is not being developed, we have no design that shows a road and plat layout that could be workable. Lacking this, it is impossible to know the feasibility of developing the property with a road connecting the Behm's development with 4th Ave. APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 12 Staff noted the property on which this hypothetical road would be built is guided as a Stage 2 (post 2010) area. Because of this, it will not be allowed to develop for some time, if ever. In addition, the comprehensive plan clearly requires decreasing the amount of annual growth. There is no way to know when this property will be developed and the road will be built. Mr. Lyden stated his first point of concern was whether a road was 44 feet wide or 36 feet wide and noted that were would be a lot of pedestrians using the road. He stated he believed they would need to have a trail in this area also. Mr. Smyser replied they were proposing a 36 -foot wide road with a trail on the side, separated from the road. He pointed out if they were just doing it as a local road, they would need to go back and look at the design. John Johnson, Director of Engineering, Metro Land Surveying & Engineering, 412 County Road D, Little Canada, asked they address the collector roads tonight only so they could move on with the design. He presented diagrams of the proposal for the Board's review and comment. Mr. Zych noted that emergency vehicle access was an issue that needed to be addressed. Mr. Johnson agreed. • Mr. Zych noted his concern was not just for emergency vehicles, but for public concern as well. • Mr. Corson stated they would not be making any decisions tonight, but would be giving direction. Chair Schaps asked what other options would they have to make an east -west connection. Mr. Johnson replied there were no other options. Chair Schaps asked if he believed it was a good idea to create two air park neighborhoods. Mr. Johnson replied there was already a north and south air park neighborhood. He indicated there was no connection between the east and west lots on the south side because of a ditch. He stated the neighbors had asked they create additional air park lots. He stated as far as if it was important for the air park neighborhood to be connected, the neighbors would be the best ones to ask that question to. Bonnie Bigler, 346 Carl Street, stated the air strip was the neighborhood and that was what connected them. She indicated they had no problem having any other type of a connection. Mike Cirese ( ?sp), 215 Palomino Lane, agreed that the air strip was the community. He pointed out a group of people with a common interest formed a tight bond. He stated this was a good community to live in and noted roads would not divide them. He stated he supported his community and if there was a way to have Carl Street remain the way it was, that was what he supported. APPROVED MINUTES • Planning & Zoning Board September 11, 2002 Page 13 Chair Schaps asked if it would drastically affect him, if it were extended. Mr. Cirese replied it would not affect him, but he could see his neighbor's point of view regarding traffic. Dave Ramsden, 302 Carl Street, stated he was against this proposal. He indicated he did not understand why emergency vehicle access came into play right now. He indicated he did not like the curving of the proposed road and expressed concern that the road would be too close to the ditch. Jim Obowa, representative of Lino Air Park, stated he had seen the plans and from the neighborhood's perspective, they would want the connector road to the north and not on Carl Street. Chair Schaps asked if he understood the concerns about the emergency vehicle access. Mr. Obowa replied he did. Mr. Lyden stated he had not seen anything from the police department, fire department, etc. that there was a concern and requested seeing something in writing. Mr. Smyser replied they would follow -up and obtain a report. Mr. Zych noted that this was an opportunity to do this right and allow for sufficient • emergency vehicle access. Chuck Kolstad, 296 Carl Street, expressed concern about the "jogging" of the proposed Carl Street. He noted an emergency vehicle would not make this jog without considerably slowing down. He stated he did not want arrows in his front yard indicating the street curved to the right. He indicated an emergency vehicle could not make it any faster into the development by taking Carl because of the jogs in the road. He stated he believed the City already had their mind made up to put Carl Street through. He expressed concern about vehicles ending up in his front yard or house because they could not make the turn. He stated most residents on Carl Street were opposed to this. He urged the Board to see his point of view as a homeowner in the City. Tom Schmelzer, 398 Carl Street, supported the connection of Carl Street. He expressed concern about dividing up the neighborhood by not expanding Carl Street. He stated it was unfortunate developments were not integrated as a main design. He expressed concern for the safety of landing aircraft. Glenn Martig, 376 Carl Street, agreed with Mr. Kolstad that with two outlets going to Sunset should be adequate for emergency vehicles and the proposed bends in Carl Street, was dangerous. He stated they had been told they would be living on a cul -de -sac. He pointed out anybody moving into the new development would know where the collector street were, but they were told they had a cul -de -sac. Mr. Lyden made a MOTION to continue the Public Hearing to the October, 2002 Planning & Zoning Board Meeting. APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 14 • The motion was supported by Mr. Corson. Motion carried 4 -0. Mr. Lyden requested public safety information regarding specifics. He requested the Air Park officers get together and come up with a list of what their concerns were. He stated they did not have the right to destroy a current neighborhood for the development of a new neighborhood. Chair Schaps agreed the Air Park needed to submit a letter and requested they address if the extension of the street in any fashion would affect their property, their neighborhood, etc. He invited anyone else in that neighborhood to also offer opinions in writing. He stated overall he had a concern about emergency vehicle access into the new development. He stated an alternative would be for Mr. Uhde to purchase the sod farm property, but there would still be challenges Mr. Uhde would need to work out. He noted sometimes the public safety of everyone became more important than one group of people. He believed Carl should be expanded. Mr. Corson stated he did not believe he had enough information on option B to know if he should agree with that one or not. He stated he agreed they needed a connection. Mr. Zych stated he wanted Carl Street to be connected. Mr. Hyden stated he believed they needed a connection. Linda Eckart, asked for clarification about the distance issue when they referred to safety. Chair Schaps stated future development would be within the square she had described and stated they wanted a connection in the middle of the square to allow for emergency vehicle access. VI. DISCUSSION ITEMS Mr. Lyden asked under action item 5A there were a couple of easements that needed to be conveyed to the City and inquired as to how that would be accomplished. Mr. Smyser replied what the City was doing now was when these types of conditions were placed on a property, the City required the deeds to be conveyed to the City before it got recorded by the County. VII. ADJOURNMENT Mr. Lyden made a MOTION to adjourn the meeting at 8:16 p.m., and was supported by Mr. Hyden. Motion carried 4 -0. Respectfully submitted, Kathy Altman, Recording Secretary TimeSaver Off Site Secretarial, Inc. APPROVED MINUTES Planning & Zoning Board September 11, 2002 Page 15 • • • APPROVED MINUTES • • AGENDA ITEM V. A STAFF ORIGINATOR: Bob Kirmis (NAC) P AND Z MEETING DATE: November 13, 2002 TOPIC: Benkler Carwash - Site & Building Plan Review and CUP BACKGROUND Ray Benkler has requested approval of site and building plans and a conditional use peimit to allow the construction of a full service carwash, a self - service carwash and a quick lube facility (within a single structure) upon a 1.6 acre site located west of Lake Drive between I -35W and Elm Street. While the applicable LI, Light Industrial district provisions do not specifically list carwashes as a permitted or conditional uses, the district does state that uses permitted in commercial zoning districts shall be allowed within LI districts. As a result, the use will be treated as a conditional use and processed accordingly. This review is based on the following plan submittals: Preliminary Site Plan dated 10/7/02 Grading, Drainage & Erosion Control Plan dated 10/10/02 Utility Plan dated 10/10/02 Landscape/Tree Preservation Plan dated 10/10/02 Floor Plan dated 10/7/02 Building Elevations dated 10/7/02 Lighting Plan dated 9/10/02 TKDA Engineering Comments dated 11/5/02 Environmental Board Comments dated 11/4/02 ANALYSIS Site and Building Plan Review Property Legal Description. The subject property is described as part of Auditor's Subdivision # 54 and comprises two individual lots. As part of the CUP processing, the two lots which comprise the subject property should be legally combined. • • Benkler Carwash Page 2 of 11 Access. Access to the subject site is to be provided via a 30 foot wide curb cut along Lake Drive. Appropriately, the access point is in direct alignment with Church Drive to the east. The acceptability of the proposed curb cut location and width as well as the need for associated roadway improvements (i.e. turn lanes) should however, be subject to comment and recommendation by the City Engineer and the Anoka County Highway Department. Circulation. The proposed use includes a full service carwash, a self - service carwash and a quick lube facility. Recognizing the co- existence of these activities, a well- conceived plan for site circulation is both very important and very challenging. As shown on the submitted site plan, site circulation is proposed to occur in a counter - clockwise fashion. While the proposed circulation pattern is considered well conceived and follows a natural tendency to "keep right ", some concern exists in regard to a users understanding of the circulation pattern and a potential for congestion at the sites entry point. To address this concern, the applicants are proposing to separate site entry and exit areas with a landscaped median and identify desired site circulation routes with freestanding directional signage. To further identify desired traffic movements, it is suggested that pavement directional signage also be provided. Two circulation - related concerns exist in regard to the by -pass lane on the west side of the property. One concern relates to the necessary u -turn maneuvers that will occur west of the building where full service carwash vehicles move from the staging area to the conveyor area. It appears conceivable that such maneuvers could interfere with access to both the self - service carwash and quick lube facility. A second concern with the by -pass lane relates to the areas west of the self - service wash and quick lube facility where a potential overlapping of vehicular stacking could potentially occur. The applicant has indicated that the self -serve wash is to accommodate recreational vehicles. It appears likely that a recreational vehicle waiting to occupy the southerly self - service stall may block access to the quick lube stacking area. While the applicant is encouraged to address the aforementioned concerns, it is acknowledged that such circulation issues are internal to the site and constitute more of an inconvenience to site patrons than a threat to public safety. • • • Benkler Carwash Page 3 of 11 Lot Size and Setbacks. The lot and building performance standards for properties within the LI District are listed below. As shown above, all applicable lot and building performance standards have been satisfied. Architecture/Building Materials. According to the Ordinance, the architectural appearance of the building may not be so dissimilar to the existing buildings or areas as to cause impairment in property values or constitute a blighting influence. As shown on the submitted building elevations, the building is to be finished in a combination of colored rock face block, face brick and stucco. Such materials are consistent with the building material requirements of the Ordinance. While the elevation indicates that the building is to be finished in two varied colors of rock face block, specific building colors have not been indicated. As a condition of site and building plan approval, building colors should be specified. Although the proposed building materials satisfy the requirements of the Ordinance, some concern exists in regard to the presentation of the building to Lake Drive. As proposed, the eastern facade of the building will consist of ten garage doors. To draw attention away from the garage doors, the applicant has proposed landscaped medians in the front of the building. Aside from "softening" the appearance of the building to Lake Drive passersby, the landscape medians also serve to channel traffic throughout the site. Required Proposed Lot size minimum 1 acre 1.6 acres Lot width minimum 150 feet 273 feet Setbacks — building Lake Drive side lot line rear lot line Setbacks - parking Lake Drive side lot line rear lot line 50 feet 10 feet 15 feet 15 feet 5 feet 5 feet 52 feet 26 feet 68 feet 15 feet 10 feet 15 feet Building height 45 feet 18 feet Green space 10 percent 29 percent As shown above, all applicable lot and building performance standards have been satisfied. Architecture/Building Materials. According to the Ordinance, the architectural appearance of the building may not be so dissimilar to the existing buildings or areas as to cause impairment in property values or constitute a blighting influence. As shown on the submitted building elevations, the building is to be finished in a combination of colored rock face block, face brick and stucco. Such materials are consistent with the building material requirements of the Ordinance. While the elevation indicates that the building is to be finished in two varied colors of rock face block, specific building colors have not been indicated. As a condition of site and building plan approval, building colors should be specified. Although the proposed building materials satisfy the requirements of the Ordinance, some concern exists in regard to the presentation of the building to Lake Drive. As proposed, the eastern facade of the building will consist of ten garage doors. To draw attention away from the garage doors, the applicant has proposed landscaped medians in the front of the building. Aside from "softening" the appearance of the building to Lake Drive passersby, the landscape medians also serve to channel traffic throughout the site. • • Benkler Carwash Page 4 of 11 Off- street Parking. The standards for calculating the off - street parking requirements for the proposed uses are outlined in Section 3, Subdivision 5 of the City Code. Use Ratio Requirement Full Service Carwash Spaces equal to five times the capacity of the operation plus one space for each employee (capacity of 6 vehicles with 6 employees *) 36 Self Service Carwash Spaces equal to five times the capacity of the operation plus one space for each employee (capacity of 2 vehicles with no employees *) 10 Oil/lube facility 2 spaces per service bay 4 Total 50 * Per information provided by the applicant The Ordinance does not indicate whether or not stacking spaces may be counted toward fulfilling this requirement. While the need for drying and employee stalls is obvious, it is believed that excluding stacking space from the off - street parking requirement for the carwash would result in an excessive off - street parking supply. Therefore, stacking spaces are considered acceptable off - street parking spaces. Including exterior stacking spaces, a total of 56 spaces are provided on site, exceeding that required by Ordinance. The site plan illustrates one handicap parking stall. To satisfy applicable State requirements, one additional handicap stall should be provided. At 18 feet in depth and 9 feet in width, all off - street parking stalls have been found to meet the minimum dimensional requirements of Section 3, Subd. 5 of the Ordinance. In regard to vehicular stacking space, the Ordinance states that stacking space associated with carwashes should accommodate the number of vehicles that can be washed during a maximum thirty - minute period and shall be subject to comment by the City Engineer. According to the applicant, it is anticipated that the full service carwash can accommodate 30 vehicles in a half hour period. As shown on the submitted site plan, four stacking lanes have been provided for the full serve carwash accommodating a total of 30 vehicles. • • Benkler Carwash Page 5 of 11 Landscaping. As shown on the landscape plan, a variety of trees are proposed on site. Specifically, mixtures of Swamp White Oak, Austrian Pine and River Birch trees have been proposed along Lake Drive. Additionally, shrub plantings have been proposed within the two medians (within the interior of the site) and clump grass has been proposed at the northwest comer of the building. Two concerns exist in regard to the landscape plan. As noted in the attached Environmental Board comments, concern exists in regard to the number of plantings provided on site. The Board has specifically recommended that additional trees be provided. A second concern is the placement of trees within the "rainwater garden" in the southeastern area of the property and their ability to survive. As a condition of site and building plan approval, the tree plantings proposed within the "rainwater garden" should be relocated. Tree Preservation. The tree preservation plan has been superimposed on the landscape plan. The plan however, does not specify the types and sizes of trees to be saved and removed. As a condition of site and building plan approval, the tree preservation plan should be modified to indicate all significant trees on site and those to be saved. Curbing and Striping. As a condition of site and building plan approval, all off - street parking areas and associated drive lanes should be provided a continuous concrete curb. This includes the planting medians on the east side of the building where such curbing will both define the drive lanes and serve to protect the vegetation within such medians. Aside from the striping of off - street parking stalls (a standard ordinance requirement), it is recommended that the one -way bypass lane around the perimeter of the building be striped and thereby segregated from adjacent stacking lanes. Trash Enclosures. According to Section 3, Subd. 4.G of the Ordinance, all refuse and recyclable materials must be stored within the principal building or within an accessory structure (within a side or rear yard) that is totally screened from eye level view from neighboring uses and public rights of way. The submitted site plan does not illustrate a trash enclosure. If trash is to be stored outdoors, the location of the enclosure should be illustrated on the site plan. Green Space. Within LI districts, a minimum green area of 10 percent of the lot area is required. The amount of impervious surface coverage on the site has not been specified. As a condition of site and building plan approval, the applicant should demonstrate compliance with the minimum green area requirement. • • Benkler Carwash Page 6 of 11 Signage. The site plan illustrates a freestanding sign in the northeast corner of the site within the "rainwater garden ". The acceptability of the sign placement (within the "rainwater garden ") should be subject to comment by the City Engineer. Details regarding site signage have yet to be submitted. As a condition of site and building plan approval, all site signage must comply with the applicable requirement s of the Sign Code. As previously indicated, the applicant is proposing freestanding directional signage to identify desired traffic movements on the site. In addition to such freestanding signage, it is recommended that pavement directional signage also be provided to ensure proper site circulation. Lighting. As required by ordinance, a lighting plan identifying illumination levels on the subject site has been provided. The proposed illumination levels and fixture details have been found to be acceptable. According to the plan, freestanding shoebox style fixtures have been proposed within parking areas while wall mounted fixtures have been proposed on the north, south and east sides of the building. According to the Ordinance, the source of lights should be hooded and controlled so as not to illuminate adjacent properties or public rights -of -way. More specifically, low- impact, downward - focused, low spill, low intensity fixtures should be used. While the shoebox style fixtures meet this requirement, the source of the light from the wall - mounted fixtures will be visible from adjacent properties. As a condition of site and building plan approval, the wall - mounted fixtures should be changed such that the source of the light will not be visible from adjacent properties. Utilities. A utility plan has been submitted for review by the City Engineer. As a condition of site and building plan approval, the utility related modifications and comments as set forth in the City Engineer's memo should to be incorporated into the plans. Grading and Drainage. A grading and drainage plan has been submitted for review by the City Engineer. One noteworthy concern related to drainage involves the handling of wastewater from the self - serve carwash. Of particular concern is the potential "dragging" of water toward the site's egress point (on Lake Drive) in the winter months and the potential for the creation of an ice slick. As a condition of site and building plan approval, the issue should be addressed to the satisfaction of the City Engineer. • • Benkler Carwash Page 7 of 11 As a condition of site and building plan approval, the grading and drainage related modifications and comments as set forth in the TKDA letter dated 11/5/02 should to be incorporated into the plans. CEPTED Review. The primary issues of the CEPTED review regard traffic flow through the development. The development has been redesigned to address these issues. Environmental Issues. The Environmental Board reviewed the request at their October 30, 2002 meeting and recommended approval. Their comments are attached to this report. To be noted is that the Board's recommendations related to lighting and landscaping have been included as conditions of site and building plan/conditional use permit approval. Rice Creek Watershed District Review. The Rice Creek Watershed District (RCWD) has determined that the proposed development will not require a Watershed District Permit as the impervious surface coverage on the property does not exceed one acre. Development Agreement: Prior to the commencement of any site work, the applicant will be required to enter into a development agreement with the City and post all the necessary securities required by it. Conditional Use Permit As previously indicated, the applicant is requesting approval of a conditional use permit to allow a carwash within an I -1, Light Industrial zoning District (both drive - through and self - service carwashes are listed as conditional uses). In considering conditional use permit requests, the Ordinance states that the Planning and Zoning Board shall recommend approval and the City Council shall order the issuance of such permit only if it finds that such use at such location: 1. Will not be detrimental to or endanger the public health, safety, comfort, convenience or general welfare of the neighborhood or the City. Comment: The proposed use is not anticipated to be detrimental or endanger the public. 2. Will be harmonious with the general and applicable specific plans and policies of the comprehensive plan of the City and this ordinance. • Comment: The Comprehensive Plan suggests industrial use of the site. Within the applicable LI, Light Industrial zoning district, carwashes are considered a • Benkler Carwash Page 8 of 11 conditional use. Thus, the proposed land use satisfies the land use directives of the Plan. 3. Will be designed, constructed, operated, and maintained so as to be harmonious and appropriate in appearance with the existing and /or intended character of the general vicinity and will not change the essential character of that area. Comment: The building design is consistent with material requirements of the Ordinance and therefore will not negatively affect the essential character of the area. The proposed building is in fact anticipated to improve the appearance of the area. 4. Will be served adequately by essential public facilities and services, including street, police and fire protection, drainage structures, refuse disposal, water and sewer systems, and schools; or will be served adequately by such facilities and services provided by the persons or agencies responsible for the establishment of the proposed use. • Comment: As a condition of project approval, the building will be adequately served by essential public facilities and services. 5. Will not create excessive additional requirements at public cost for public facilities and services and will not be detrimental to the economic welfare of the community. Comment: This development is not expected to increase public costs, nor be detrimental to the economic welfare of the community. 6. Will not involve uses, activities, processes, materials, equipment and conditions of operation that will be detrimental to any persons, property, or the general welfare because of excessive production of traffic, noise, smoke, fumes, glare, or odors. Comment: The proposed use of the property is not expected to create any excessive externalities that would be abnormal to the character of the area. 7. Will have vehicular approaches to the property which are so designed as not to create traffic congestion or an interference with traffic on surrounding public thoroughfares. • • • Benkler Carwash Page 9 of 11 Comment: The site layout meets standards held within the City's Zoning Ordinance including turn lanes, access width, and access spacing/location. 8. Will not result in the destruction, loss, or damage of a natural, scenic or historic feature of major importance. Comment: The applicant is currently working with the City Engineer to satisfy drainage related issues. 9. Will conform to specific standards of this ordinance applicable to the particular use. Comment: The proposed use will as a condition of approval meet the applicable requirements of the Ordinance. RECOMMENDATION Based on the findings contained in this report, our office recommends approval of the Site and Building Plan and Conditional Use Permit to allow the construction of a full service carwash, a self - service carwash and a quick lube facility (within a single structure) upon a 1.6 acre site located west of Lake Drive between I -35W and Elm Street subject to the following conditions: 1. The two lots, which comprise the subject property, be legally combined. 2. The acceptability of the proposed curb cut location and width as well as the need for associated roadway improvements (i.e. turn lanes) be subject to comment and recommendation by the City Engineer and the Anoka County Highway Department. 3. Building colors be specified. 4. One additional handicap parking stall (totaling three spaces) be provided to satisfy applicable State requirements. 5. Additional trees be provided on -site as recommended by the Environmental Board. 6. Tree plantings proposed within the "rainwater garden" be relocated. Revised plans depicting such change shall be provided prior to City Council consideration of the application. • • Benkler Carwash Page 10 of 11 7. The tree preservation plan be modified to indicate all significant trees on site and those to be saved. Revised plans depicting such change shall be provided prior to City Council consideration of the application. 8. All off - street parking areas and associated drive lanes (including the planting medians on the east side of the building) be provided a continuous concrete curb. 9. The one -way bypass lane around the perimeter of the building be striped and thereby segregated from adjacent stacking lanes. 10. If trash is to be stored outdoors, the location of the enclosure be illustrated on the site plan. Revised plans depicting such change shall be provided prior to City Council consideration of the application. All refuse and recyclable materials shall be stored within the principal building or within an accessory structure (within a side or rear yard) that is totally screened from eye level view from neighboring uses and public rights of way. 11. The City Engineer provide comment and recommendation regarding the proposed sign placement within the "rainwater garden ". 12. All site signage comply with the applicable requirements of the Sign Code. 13. Pavement directional signage be provided to ensure proper site circulation. 14. The wall mounted light fixtures be changed such that the source of the light is hooded and controlled so as not to illuminate adjacent properties or public rights -of -way. Specifically, low- impact, downward - focused, low- spill, low - intensity fixtures shall be used. Revised plans depicting such change shall be provided prior to City Council consideration of the application. 15. The conditions of the TKDA letter (dated 11/5/02) related to grading, drainage and utilities are satisfied. The easement issues must be resolved prior to City Council approval of the application. 16. Prior to the commencement of any site work, the applicant enter into a development agreement with the City and post all the necessary securities required by it. The agreement shall also contain an operation and maintenance agreement. • ATTACHMENTS 1. Preliminary Site Plan 2. Grading, Drainage & Erosion Control Plan 3. Utility Plan 4. Landscape/Tree Preservation Plan 5. Floor Plan 6. Building Elevations 7. TKDA Comments 8. Environmental Board Comments • • Benkler Carwash Page 11 of 11 •TKDA • TOLTZ, KING, DUVALL, ANDERSON AND ASSOCIATES, INCORPORATED ENGINEERS • ARCHITECTS • PLANNERS November 5, 2002 Mr. Jim Studenski, P.E. City of Lino Lakes Engineer 600 Town Center Parkway Lino Lakes, Minnesota 55014 Re: Ray Benkler Car Wash Commercial/Development Engineering Review City of Lino Lakes, Minnesota TKDA Commission No. 12475 -002 Dear Mr. Studenski: The following engineering review is based on these documents: 1500 PIPER JAFFRAY PLAZA 444 CEDAR STREET SAINT PAUL, MINNESOTA 55101 -2140 PHONE: 651 /292 -4400 FAX: 651 /292.0093 • Preliminary Site and Building Concept for Ray Benkler from Raymond R. Raffel, Architect. Dated October 7, 2002, but unsigned. • Grading, Drainage and Erosion Control Plan for Carwash Site - Ray Benkler, as submitted by Glenn Rehbein Companies and W.A.T. McCully, P.E. (3 plan sheets and dated October 11, 2002). • Stormwater calculations (HydroCAD) by Glenn Rehbein Companies entitled Ray - 2nd Revised Carwash Site (12 pages). • Previous Ray Benider Car Wash Site engineering review comments from City Engineer and dated October 9, 2002. • "A Geotechnical Evaluation Report" for Benider Carwash by Braun Intertec Corp. (Darin E. Hyatt, P.E.) and dated May, 8, 2002. Engineering Review Comments: A. Grading Plan: 1. Show existing topography around property perimeter to a fifty (50) width from property line(s). 2. Identify area to west of development site as an existing stormwater pond, including ownership. An Equal Opportunity Employer Mr. Jim Studenski, P.E. 411 City of Lino Lakes November 5, 2002 Page 2 3. Show proposed easements for drainage purposes. Show drainage and utility easements parallel and along the proposed property lines. 4. The proposed infiltration swale along the northerly development property line is shown with a 2% slope but computes to only a 1.6% slope between the rainwater garden and the west infiltration basin. Correct on plans and in stormwater calculations. 5. Correct and revise parking stall grades as water appears to be trapped in the northerly stall of six (6) stalls on the east of the site and south of access road from Lake Drive. 6. Recommend that when on -site or imported soils are used to fill low areas that they must be a minimum "SCS - Soil Group B" material. 7. All development site concrete curb and gutter is to be Mn/DOT B618. For the proposed "flat" areas, it is recommended that a pattern be established to maintain the back of the curb to the maximum extent possible. This will be a better guide to vehicle drivers and will protect the adjacent stormwater system from damage. The pattern should consist of a three (3) foot opening with one (1) foot tapers along areas designated for "flat" curb, as shown on the plans. 8. Provide to the City a copy of the Anoka County Highway Department permit (approval) for driveway access requirements prior to construction start-up. B. Watermain: This extension and service would require plans and specifications that follow City standards for utility construction in public rights -of -way. It would also require Anoka County, Lino Lakes, and Minnesota Department of Health permits. C. Sanitary Sewer: In general, the proposed sanitary sewer alignment from 4th Avenue to the Development site is acceptable with the following comments: 1. Provide the City with a permanent 20' wide easement that is parallel to the proposed sanitary line. Also, grading along the easement that provides future maintenance access. 2. A sanitary manhole will be needed at the junction of the N -S 8" sanitary pipe and the 6" sanitary service pipe to the building. Also, check with the City regarding the size and material of the service pipe to the building as well as clean-out or other manhole requirements. • Mr. Jim Studenski, P.E. S City of Lino Lakes November 5, 2002 Page 3 • 3. There are concerns regarding wetlands possibly crossing the sanitary sewer alignment. If there are wetlands that will need to be crossed, then these areas should be identified in plan and specification format including solutions for addressing any wetlands crossing issues. Generally, crossing a wetland with a sanitary sewer pipe is discouraged. 4. Since the 8" sanitary sewer line will be owned and maintained by the City, plans and specifications following City standards for utility construction in public rights -of -ways and/or easements. This work will require a permit (approval) from the Minnesota Pollution Control Agency for sanitary sewer extensions. D. Erosion Control: 1. Label and list on the plans an erosion control schedule for the project. 2. The City reserves the authority to site - inspect and provide instruction to the Owner for the installation, maintenance, repair and removal of all erosion control devices. This is regardless of whether it has been shown on the plans or not, if it is deemed to be in the best interests of the City. Owner to provide unlimited site inspection access to designated City Staff until such time as erosion control devices are no longer deemed necessary by City forces. 3. Owner's civil engineer to provide design for the type and depth of the growing medium material to be placed at the labeled infiltration basins, infiltration swale and other sod/seed areas throughout the development site: E. Storm Sewer System: 1. Storm calculations (Ray - 2nd Revised Carwash Site and dated October 10, 2002): • Page 3 under Subcatchment 3S, change Curve Number (CN) for pervious parking area from 10 to 49. • Page 5, revise calculations for Reach1R: NSWALE as outlet invert cannot be 896.4 as this is lower than any elevation throughout the storm system. • Page 7 under Pond 3P, West Infiltration Area and Routing #4: The modeling says that a "27" Horiz Orifice/Grate" is being used to convey stormwater to the existing pond along the westerly property line. From the information shown on Plan Sheet 1, an 8" PVC pipe would be the controlling factor. Please modify to fit the plan sheet or provide an explanation for how this component works. 2. Contours shown along westerly property line do not show enough detail and would fall into the adjacent private property. If as Plan Sheet 1 indicates, an 897 contour (not shown) would be needed on private property in order to construct to the 897.75 top of Mr. Jim Studenski, P.E. • City of Lino Lakes November 5, 2002 Page 4 • • berm. If this is the case, then easement documents need to be submitted to the City. Also, rip -rap and an 8" PVC. storm outlet pipe along the westerly property line are shown on property that is not on the development site. This would require an easement to be submitted to the City. 3. MH with R -4342 casting and 8" PVC outlet located along the westerly development property line. The 8" PVC is recommended to be changed to a 15" RCP with fixed end section and set at the normal water elevation of 895.7 (instead of 895.00 shown on the plans). That is, the outlet structure and pipe are recommended to be re- designed. 4. Provide stormwater calculations for the 2 -year design rainfall event, the 10 -year design rainfall event and the 100 -year (revised) designed rainfall event. 5. Determine if 4" or 6" perforated draintile (or both) will be used on the project. Either correct the plans and/or re- compute the stormwater runoff /routing calculations to match the sizing. 6. Provide the City Engineer with literature and technical data describing the proposed "4- inch Netlon Advanced turf' and "Netpave 50 backfilled with 3/8" clear- washed dresser trap bit. admix rock" for review. There are concerns about permeability and bituminous component of the Netpave regarding compaction over time. 7. Prior to construction commencement, provide the City Engineer with a completed copy of the MPCA -NPDES permit.. 8. Regarding separation between groundwater elevation and the mostly westerly infiltration basin base or finish elevation. Groundwater elevations have been established by two (2) soil borings as described by a Braun Intertec Report (May 8, 2002). The groundwater elevations were 890.5 and 892.5. These groundwater elevations provide greater than the three (3) foot separation from all of the development site proposed basins or swales base elevations. It is also recommended that nearby private water supply wells be located for adjacent properties to determine the proximity of the water wells to the stormwater system. The location of the adjacent private wells along with well log information needs to be provided to the City Engineer for his review. 9. Pretreatment features, such as basin slope geometry, ponding water depths and detention time, length/width for ponds, swale slope and overflow issues have been addressed on the revised plans. It is recommended that these plan items be accepted as shown. Mr. Jim Studenski, P.E. City of Lino Lakes November 5, 2002 Page 5 10. Provide Construction Sequencing and Maintenance Plan for review and consequent approval. It is recommended that these items be provided to the City Engineer for review prior to plan approval. In specific, it is recommended as part of the Maintenance Plan that the Owner be required to file yearly reports to the City describing the working condition of the stormwater system by a qualified person capable of recommending corrective measures as they become apparent. It should be expected that the rainwater gardens would need removal and replacement for plugging on an average of three (3) years. F. Provide preliminary plat for review and approval that includes all the easements for drainage and utilities. Should you have any questions, please feel free to contact me at 651/726 -7925. Sincerely, kI\ /‘ \tJ.-(, Patrick M. Windier, P.E. Project Engineer PMW:art r • 1 Environmental Memo To: Jeff Smyser From: Marty Asleson CC: Michael Grochala Date: November 4, 2002 Re: Recommendations /Environmental Board/October 30, 2002/Car Wash The Environmental Board recommended the approval of the Proposed Lake Drive Carwash with the following stipulations: • That the soil boring documents submitted to the Environmental Board be analyzed by our City Engineer to determine if the seasonally high water elevations are at least 3 feet from the bottom of the designed infiltration ponds. The Environmental Board recommended that an additional boring be drilled at the Westem most infiltration pond to ensure that this 3 foot separation will exist. This additional boring is requested at the discretion of the City Engineer. • That the lighting plan be changed to reflect our City standard for low- impact, downward - focused, low- spill, low- intensity fixtures. • That the project applicant submit a sequence plan and Best Management Practices Plan. Best management should include a plan for periodic sweeping of the parking areas, trash and litter pick -up, proper storage of any materials that may spill into the environment, and a plan to maintain the pervious surfaces in the design. The Environmental Board requested that no pesticides be used on the pervious surfaces. • That the developer would change landscape species in the proposed plan, as requested by the Environmental Board and provide additional trees in the landscape. • Page 1 11i_ir__ MWM ,,:; .., Aer1 SPIMRNYIIMF2NlMiy/Nyq�H yy A1r1�11tlif }�AICW�r; • • GF2AD 1 \G FLAN 1 so GRAPHIC SCALE (IBI MET ) 1 BneR - 9:0 IL 0.5CY CIJI RIPRAP CY am O 6" ADS N12 RIPRAP PERFORATED PIPE CHECK DAM NO GRADING TO BE DONE OFF STE ,� 1 SALVAGE AND 0 REPLACE RIPR - C q 0; 1405F,4ETLON YIX EROS$ON CONTROL 2002 900 - - --- 4CY CLII RIPRAP �y OVERFLOW /CHECK 2/4' FLAT CURB/ DAM - /I CIJI' RIRRAP."' -; V7 v a V 0AP(WATER+ a 7 VWWI 7 77 7 7 7 7 VV 6 1.1111•8111111101110111.11111 sr 0 vIPIP_ ; a Pc E /' !CY ELO RIPRAP �gL OVEkFtow /cHECK DAM .691.E •:r; CASING R -4342 RI►t 697.70 NY.695.90 6" PVC 695,00 ( 802.06 zr'CL 1 i 'CL GRADING NOTES AND SEQUENCING SILT FENCE TO BE INSTALLED DOWNHILL FROM ANY GRADING ACTIVITY SOME TREES AND DEAD FALL ARE TO BE CLEARED BEGIN STRIPPING TOPSOIL IN RIGHT OF WAY SITEWORK SHALL BEGIN ONCE SILT FENCE IS INSTALLED CONSTRUCT AND MAINTAIN ROCK CONSTRUCTION ENTRANCE OFF LAKE DRIVE SILT FENCE TO BE MAINTAINED DURING GRADING SEED AND MULCH DISTURBED AREAS WITHIN TWO WEEKS OF FINAL DISTURBANCE SEED MIXTURE SHALL BE MNDOT SPEC 3876, AT A RATE OF 35 PLS Lbs /ACRE OR MNDOT SPEC. 500 AT A RATE OF 50 PLS Lbs /ACRE MULCH RATE SHALL BE TWO TONS PER ACRE MIN. BSMT. OR FLOOR ELEV. SHALL BE A MIN. OF TWO FEET ABOVE 100 YEAR POND /LAKE ELEVATIONS ANY RIPRAP SHALL BE CLASS 11 CONTACT WILLIAM MCCULLY AT GLENN REHBEIN COMPANIES AT (763) 784 -0657 STRIP PERVIOUS PARKING AREA AND FILL WITH WASHED SAND 2' BELOW FINISHED GRADES OVERSIZE WASHED SAND AREAS AT 1:1 PREVENT COMPACTION OF PERVIOUS AREA DRAINTILE UNDER BITUMINOUS TO BE COVERED WITH 2" INSULATION, 4' WIDE •••NO GRADING TO BE DONE OFF SITE LEGEND SILTFENCE PERVIOUS PARKING SF SF RAINWATER GARDEN 7 SF ,..-----r 7 7 7 7 V'`' 7 c 7 V 7 c a v 7 07 07777.77'? 7 .. 7 .7 vC 0 7 0 7 7 7 7 7 a a. a. 7 777 - f t+sto- C INFILTRATION BASIN �- - ' • • • - - - • • -- i • . • c NETLON AREAS PA M NT CTION 1.5 ":ITWEA 1.5" BIT. BASE 6" CL V RECYCLED 'Cr Oq'NRF o *j -.1P // .4C 02.04 1,4? ^!1` •�V Q 4~T /1' 02.02 / CL f ' `CL MANTNN ROC( DORMICE IF TRACKING BEONS ROCK CONSTRUCTION ENTRANCE (HEREBY EER1WY THAT THIS PLAN OR SPECIFICATION WAS PREPARED OT YE OR UNDER YY DIRECT SUPERM90N AND THAT I MI A OULY REQS1ERED PROFE5S91014IL ENGINEER UNDER THE LANS OF THE STATE OF YNIESOTA W.A.T. lAcCOLLY pATE: RFC. No.2j 12 % B iii 11/l7TURF DISTALLATlON AT tNLRG CY ReON O .1 rs N0 b17DNo�rs�0 MY IffN.S. l" 0114Y(a or MOM MOO NO ISM Nr" - a ,e,s tort aaa■ .Nlt 10!/1100. s ac 01110117.171•I AL >s NIY 10 111t 1111011 M RN .RCS ION P1Nr . . f rRr 17IFIV OI Rn LR.w""'Gri.Ni1pO"`imlK 1°b`"{.ma'u"'o�i'iiOali"J`Lft` 'b.'°"`� Z W 1 DRL O D DATE 08/12/2002 'ERnCA1 SCALE HOW, 1' : 20 .108 NO. 02504 BOO( PACE SHEET \or 3 slicers/ SITE AND UTILITY PLAN 60' 8l PVC SDR 35 0.5% CONNEdT TO EIOSTINc OUTSIDE OR INSIDE ()ROP CORE 11V:889.0 SSMH1 RIM:901.0 INV: 889.40 INV: 889.30 7 Art TA EX-1413'3 TC 90P.0 INV:88 .97 8" rePt B 0 889 /,9 I fro 901.) -'F UTILITY NOTES • .rs ;‘5 5514112 RIM: 901.0 / INV:890.05 INV:1389,95 ' 400' 8" / PVC SDR 35 0.5% WATERMAIN SERVICE CONNECTION TO BE MADE . FROM EXTENSION OF 12" TRUNK MAIN IF REQUIRED DOMESTIC AND FIRE -FLOW SHALL BE SPLIT IN THE BUILDING PROPOSED 12" WATERMAIN EXTENSION WAS PROPOSED TO BE ON THE EAST SIDE OF LAKE DRIVE CITY TO DETERMINE IF 12" DIP WATERMAIN NEEDS TO MOVE TO WEST SIDE OF LAKE DRIVE SANITARY SEWER SERVICE SHALL BE EXTENDED FROM MAINLINE ON WEST PROPERTY LINE NO SEWER SERVICE CURRENTLY EXISTS FROM THE WEST SANITARY SEWER TO BE EXTENDED FROM 4TH AVENUE AND TO THE SOUTHERN PROPERTY LINE PLAN AND PROFILE CONSTRUCTION DRAWING SHALL BE SUBMITTED AFTER ALIGNMENT APPROVAL NO TREES TO BE PLANTED OVER UTILITY LINES OR IN ANTICIPATED EXPANDED ROW PROVIDE 2" INSULATION, 4' WIDE OVER /(" DRAINTILE WHERE IT IS UNDER BITUMINOUS 8" SITE NOTES TOTAL SITE AREA:1.56AC TOTAL IMPERVIOUS:0.98AC /42,819 SF OR 63.1% TOTAL PARKING SPACES:16 FLAT CURB USED WHERE SHOWN TO CONVEY WATER TO RAINWATER GARDENS AND INFILTRATION BASINS AND SWALES RETAINING WALL TO BE NO TALLER THAN FOUR FEET RETAINING WALL GREATER THAN 3.5 FEET SHALL HAVE METAL BANISTER NETLON NETPAVE 50 USED TO CREATE PERVIOUS PARKING SPACES AND DRIVE LANES LEGEND PERVIOUS PARKING 5c , v c v7:oc7c voocv.,, RAINWATER GARDEN i G^ G' G 7 c 7 7 C7 ^. G^ G v c INFILTRATION BASIN NETLON AREAS 0 726 90 O GRAPHIC SCALE N • IN .[rrrw .NL cm.) ( se F T) 1 Web - 30 It AMON IULMY 00 r WYNN INrc Nal 1.5' BIT. YEAR 1.5' BIT. BASE 6" CLV RECYCLED al' STEP 4' NETLON ADVANCED TURF S5A1H4 RIM: 901 IN V. 892.63 0.2' LOVER 6' TESTED SAND z• PEA GRAVEL FLAT 24' CURB SLOPED ENDS TRAN9110N TO 8612 CURB 60- A4 PERF. ADS 1112 NETLON AREAS CURB TO CURB DETAIL MAY BE LANDSCAPED / \or GRANULAR NSITU MATERIAL 6 / R\ � 1 \ 7444k P 1k ,1 _� \ q a v:ooc 1 \ -1`' °sue/ \ / LS at EM IS OM IAEE C Qv MCTWD 32 2,g IMAM 50 /60611110 MI 3/4' DEAR- 1M51FD 136593 TRAP -BT. /MX ROC IE1O11 11100 INTO TIE 10, 7' OF SAM we as 9021ME TO IC AT 10RCY OF STRPP.IC tA1ER RAT 2C CPS SLOPDO 005 104419301 10161: OM A=11=11=11ll =11 = II =1i =D n n -n -il: :::::::: '11=11=11=F =11=11=-11' ^ I1 =11- .. ... ...- .,._ _ - .. � -... .. -•. 171 -11 =. 11- 11= `V- Ta11-n ll= 1I- 'ffnali :=1: ll=` 2Tias- lr=`Ir`LII= `u- 1r-1r` r'' i = il= n= n -uii -u 11= n.7- -11 =11= 11=11 -11 , 11- 11-. i1= 11= II- 11- 11= 11= 11= IR- 11= 11= 11= 11= 11- II -11= 11_11._1. t•- Ir -,Y- „� NOTE: I ISTML ORMN111 AS SAN) 6 16TA11ID N F. A051112 1ASIED CONCRETE 05 SPOR19ER 11PE 5440 NETPAVE AREAS CURB TO CURB DETAIL DUMRMt 11110 NAW UAL NAM 5ATO EDGES TO I DOMED AT A 1:1 SLOPE (REVISIONS B\ PER CITY 9 -9 -02 DRL PER CRY 10 -10 -02 WATM 1 (CREW CERTIFY THAT TINS PLAN OR SPECIFICATION WAS PREPARED BY ME OR UNDER MY 0l CT Sl1PERNSION ANO THAT I AM A DULY REGISTERED PROFESS/0N& ENGINEER UPWER THE LANS OF THE STATE OF Im11ES0TA YLA.T. McCULLY $40.23L381 / Q W fy CL d Q >- J O =Z V) 2 w D >--z W � � V ORL CHECKED WATM DATE 08/12/2002 VERTIC6L SCJALE HORIZ. : 30' .100 MO. 02504 BOOK PACE SHEET 2 3 SHEETS) 3 OF 3 5IEETS 4 LANDSCAPING & TREE PRESERVATION PLAN TRIES KEY Scientific Name Cotranon name Hebtat• Comments AG Antelesd'd inimilflora 'Annum Brie' --= Amsam Brilliance Swacebary MD Cheep form AR Am' rabrae.'Notduwooda' Ikrthwooda Red l.4ple M Mo.. tolerant BN Sa da Mean Ri•erBurb MD Champ f CC C.MMa use- A&1fr.r. Men. Thanker Hawthorn MD Drought tenant CO Cakesoa4.ddi, Heckhary 14D Toksm wet sites MP Maher 'Pr.iucfre' PakdueFlowakg Crabap*k M Red 2.5-3' nabtomirg MS Makes'Smyian' Sugar Tye. Flowering C M Pik 2- 3'apblmig PGS Now lemma donate Beek fide Spruce MET Red3' PN Pietas tetra Austrian Pine MD S•ktolerant PR Phase miaow Norway or Red Pint MD Red 23- 3'ereshbaaing PT PopdaaMwtddca Qukig Aspen MD Plat i.gmnpig QB Damn bicolor Sweep White Oak MD Camped SRI Syrimea nw/arlda'Ivory Silk' Renew Tree Lilac M 10-12' SHRUBS Ke9 Scientific Name Crememume Habitat Commits AGC :amain pd ' Compact Amer Maple MD MW CS Conner memo lane las. Dogwood MW Mo.. tolerant DL DieMlles keep& Dwarf Bash Honeysuckle DM Draught tolerant IBC hNpener 'Bhr Chip' Eke chip Juniper MD Gaepie PPG Picea ping.. 'Globose DwnfBbn Sprout MD Toksm wet sites RC Ram 'Champlain' Chempkio Shrub Rom M Red 2.5-3' nabtomirg RC Rasa 'Carefree Wonder Carefree Weeder Sbrab Rose M Pik 2- 3'apblmig RGV Rom 'George V.eeoorer George Vanm.er Shrub Rose M Red3' RH Rosa 'Hairy Hudson' Huy Hod. Shrub Rase M White 3' RICH Rasa 'Hope for Han.nt Hope for Humanity Shrub Rose M Red 23- 3'ereshbaaing RW Rosa 'Maim; Perko Winnipeg Pula Shrub Rue M Rod 2-2_5 exmbkamiog SG Sleeve 'Goldmound' Gokhaormd Spina DM Camped SH Syrb.ga z liyaeleitheiflone 'Poc.hoema' Pedant= Like M 10-12' SP Syringepvmlo 'Dins Kim' Mm Kim Lilac M 6-1' PERENNIALS AND PRAIRIE PLANTS (PORES) KEY Sciatific Name Cameron narae Habitat Size Comments AD Aaciepius hcmwata Stump lfilkwead MW 23- Widely adaptable CV CorsoprisvertldVam 'Zagreb' Zagreb Caeops's MD 01 Tolerate deoogk EM apemen. no elate Jan Pye Weed MW 23" EP &Mom e a pima* Pope Cone Flower MD 4' Toksm wet sites HPM Hanerun.Str'Pardon Me' or 'Baja' Daylily 'Pardon Me' M MI Deep Rod HSD He erocallis'Stella de Om' or 'Ropy Rattans' Sk la de OroD.ylily M 01 Golden yeller err light yeller IS lift stheks 'Raffled Velvet' Reeled Vela Sberen hie M 01 ry per renhnler Blue FOg Tub MW 4" MF Mwwdaftradose Wild Beaune MWD 25" NW Motto XAmend 'Walkers Low' welter's Low Catmint MD 01 Toler.te drought RG Rrameckia'Oddes a' Oedema Studbooks. or Bon mEyed Satan MD 4' GRASSES KEY Scientific Nme Comwas.° Habitat Sire Comment CA Cak.nagroatlr z axSJkra/Cori Foerster' Feather Reed Gar M 4' Widely adaptable SH Sporoboh& ?murals*, Pa cie Dropeeed M 4' SN Sargbasmo. em. Inch= Gnu M 4" SP Spare. pece.m Prairie Cadgrb. MW 23" Toksm wet sites 33 Sd anchyriom scope/.s Little Bhrnkm MD 4- •0- Plant safes • dry . ite, M - Masi -pleat prefers asite that is moderately, be not areessirely moat. W Plan pew • moan ketion std will tolerate shat periods of.ta>ubng water or moderately keg periods of constantly mom sal msd tioo. REQUIREMENTS FOR TREES, SHRUBS, PERENNIALS, AND PRAIRIE PLANTS: • All deciduous nee are to be 2" in diameter or greeter (termed at 6" from grand) and me systems hall and Mewed (B&B) and supported o. a sturdy wee basket that holds the mot 1&B i a fun, rgid condition (See pp. 5-6, item 13.1 through 1.4 of AAN Standards for Nursery Stock). • All rape. (coniferous)hem are to bey'6' in height and tree dug and psoolsad using B&B method with Wady wire basket wand root 5.11. Mfiimm root ball diameter shall be the same as those specified for deciduous trees (nem 13.1 through 1.4 and pp 14.15, iron 32.1) Minimum dimmer ball is 20- fe • 5' eonata, 22" minimum for . 6' treA • Al shako, evergreen and deciduous, are to be of 45 gallon omtamer aim (u 83 or 05 pot size) • All paemiak and prairie plants are to be in contain= no m.Ber than what is specified in plant list. Container size specified ed in inches refer to the diameta or width ofooaaioa or pot. A 81 size refers to a 1 gallon siaoamaimr. OTHER REQUIREMENTS • whin d1 tree ad dvubs with 4" of hardwood shredded bark mulch. Mulched areas .round tree bunk should be 4' in diameter. • Mukh all perennial beds wish 2' of hardwood shredded bark ankh • Af1er pleating and before mulching apply • granular pssanerged herbicide (such as Preen) arced all plies. • Edge •11 beds with Black Dimmed Vinyl edging or equivalent • Water plants thoroughly after planting. Aiwa wet down mulch thoroughly so moisture pooenate into soil below in order to activate herbicide. REQUIREMENTS FOR SEEDING AREAS: • btfsltradar brim shall be seeded with • Prairie Rera.« musedhdgbtIMak Wildflower sad mix. Secdiog th.D be broadcast at a4 oz/1000 SF. • Gar areas and berms dull be seeded with • Prairie Resmatims ShortlDrf seed mu. Seeding can be broadcast at • 0316. PLS /1000 SF or drilled at 10 Ibs PLS /ace • Rain water gardens shall be planted with Is.oti Dogwood, Red Twig Dogwood and Pussy Willow shrub. In ad6tim Swamp Milkweed, Marsh Mkrigold, Joe Pye Weed, Blue Flag kis, Blade Eyed Stan and Big Blue Stem Clomps will be mod A plea shall be placed every 25 square feet S nlinwala Peden =806,1 NE rainwater g.rdea -1769 sf GRAPHIC SCALE ( IM PCT) 1 Web - PA R SSMH3 RIM: 898.0 INV: 892.05 INV: 892.15 LEGEND SWAMP WHITE OAK PINE ails GRASS CLUMP G ® SHRUBS AND 0 0 PERENNIALS GENERAL LANDSCAPING NOTE$ NO IRRIGATION PLANNED SEED ALL DISTURBED AREAS AND BERMS WITH SPECIFIED SEED SEED INFILTRATION BASINS WITH THE PRAIRIE RESTORATION MIX ALL TREES TO BE BALL AND BURLAPPED AU. TREES SHALL BE STAKED AND GUYED PER NURSERYMAN'S STANDARDS LANDSCAPER TO INSTALL EDGING MATERIAL AROUND SHRUBS, FILLED MATH MULCH OR ROCK PER DEVELOPER'S CHOICE PRESERVE AS MANY TREES ALONG NORTH, WEST AND SOUTH PROPERTY LINES AS POSSIBLE oi -r 1 7.7 /RATION SWALE w • .. CASTING R -4342 RM :897.30 INV:895.90 8" PVC 895.00 3MH4 M:901 V: 892.63 QB PN PN PN 2 —AG BN BN I1 HEREBY CERTIFY THAT THIS PLAN OR SPECIFICATION WAS PREPARED BY ME OR UNDER MY DIRECT SIIPERN510N AND R4A3 1 AM A DULY REGISTERED PROFESSIONAL ENGINEER UNDER TIE LAMS OF Tit STATE OF MINNESOTA LAT. M<CLLLY b E: REG NO.I]y7! / • DRAW14 oat CHECKED WATM DATE 08t _12/2002 voiOCAL SCALE HGta2. J08 N0. 02504 BOOK PAGE 0 • 0 z ro 1 1 I 1 • 1 I 1 I I.- -- --I 1 - - - --_I r I air/ I t etirr_ loy.10 i 1 10'X10' `Ta6o-4& 1►J . fi w r 3t 6 =o sae 2 X44 33 Vi PZ 3 OIL 10?l'e GK Ttg 1- dl A- C 11:F-e A Cs c4.OM. .'0••. C.3101.11.414 1 • ..40.x ., 4-014t- RAPIPCitc•Aga•Cli... •4001t.V. 40.1100. 44004. oilloCZ 0 4•441.0144 balgarvir if • / {i1.01LA • ur11Hitp 14ep!.1w N. a tL -awor 11xrrx "x01441LA .t MJ� FHl ln4 wt.olc 1s • 9 614400 p,oGiEr[ -.tii wn+� ry .PGt.i. uup. 6 1E t'1ai7.1. pJlyd ir4. a! rt4' Ids.d to's. to' C.p1:01.60 R.oty -Mce, store. fSyIGM.'.G¢-oR GIL UL $'G$FA-Ct • .:G or4c.(QULtK 401.411.. A _G 04910 RPC1410C4. –._ CA.0 014.146- AotoiciL =_.. Aawyrac - J.OG9FfXGi Gl+b/Fi% Ge —. b5t lb• .ort. A SHEET P3 3 AGENDA ITEM 5B STAFF ORIGINATOR: Tanda Gretz P & Z MEETING DATE: November 13, 2002 TOPIC: Site Plan Review for UDOR Co. for an expansion to their existing building ACTION REQUIRED: 3/5 vote • BACKGROUND Mr. Gordon Johnson of UDOR company is applying for a site plan review in order to construct a second expansion onto their current facility at 500 Apollo Drive. UDOR first constructed their 6,000 sq.ft. building in 1994. In 1999 a 2,400 sq.ft. addition was constructed. The applicant is now asking for approval for a second addition of 3,600 square feet, to be used for cold storage /warehousing and testing. This report is based on the following attached exhibits: 1. Existing Conditions Plan (C1-1), dated 10- 31 -02. 2. Site Plan (C2 -1), dated 10- 31 -02. 3. Grading, Drainage & Erosion Control Plan (C3 -1), dated 10- 31 -02. 4. Utility Plan (C4 -1), dated 10- 31 -02. 5. Landscape Plan (L1-1), dated 10- 31 -02. Os • • Planning & Zoning Board UDOR Site Plan Review November 13, 2002 ANALYSIS Land Use Compatibility Direction Land Use Zoning Site Industrial Light Industrial North Industrial Light Industrial (General Business to the NE) East Industrial Light Industrial South 35W 35W West Industrial Light Industrial Site Description UDOR is located at 500 Apollo Drive, with the rear of the property abutting the 35W interstate highway. The proposed addition site is immediately adjacent (south) of the 1999 addition. There is a ponding area to the southwest of the proposed addition site. Access to the addition is to be completely internal; there are no docking bays, parking, or sidewalks proposed to access the addition. Setbacks Setback Required Proposed Front — from Apollo Drive 50 feet + 50 feet Side 10 feet + 10 feet Rear — from 35W 50 feet + 50 feet Building Issues The applicant has submitted no full -view elevation plans. The proposed addition is to be constructed of rock faced block to match the existing building in terms of construction material and height. Since the addition site is at the rear of the lot, with a ponding area to the south of the site and only approximately 15 feet on the north side of the site, access for construction purposes will be via the property to the north, with which the applicant has an acquired an access agreement. • Planning & Zoning Board UDOR Site Plan Review November 13, 2002 Public Services This site is served by both City water and sewer. The existing building is, and the proposed addition will be, sprinkled and meet fire code. Parking/Access /Traffic UDOR is a warehouse -type facility with approximately 2,000 sq.ft. of office space. However, parking requirements for the initial building approved in 1994 were based solely on warehouse use and square footage (1 stall for each 2,000 sq.ft.). The parking calculations made at that time were for 6,000 sq.ft. of warehouse and 6,000 sq.ft. of future warehouse expansion, for a total of 12,000 sq.ft. of warehouse. Thus, 6 parking stalls were required, with 7 stalls actually constructed. As a result, parking for the proposed 3,600 sq.ft. addition has already been provided for. The applicant reports that there are actually eight stalls at the site and that parking is not a problem. The applicant further reports that there are seven employees at the company, with no additional employees proposed. Access to the site is via a shared access driveway off Apollo Drive, which is a County road. As a result, plans have been forwarded to Anoka County for review. • Lighting There is no additional lighting proposed for the addition or site. Landscaping City Code allows impervious site coverage up to 90 %, and the proposed addition is within this requirement. Approval of the initial building in 1994 came with the following requirement: "Following completion of the proposed expansion, plantings will be located to the rear of the property line to provide an appealing view from I -35W." Since this second expansion appears to use the space limits of the site, with no room for further expansion in the future, it is now appropriate to require the landscaping be done. As a result, the applicant has proposed planting 11 trees of various varieties (oak, maple, spruce) in the buffer area between the proposed addition and 35W. Additionally, there is a ponding area on the site, to the southwest of the proposed addition. This should be protected with silt fencing during construction • • • Planning & Zoning Board UDOR Site Plan Review November 13, 2002 Grading/Drainage City Engineer Jim Studenski has reviewed the submitted plans and reports that they generally meet City requirements. The following two outstanding issues need to be resolved, after which final approval can be given: 1. Drainage calculations must be submitted. 2. Documentation allowing access to the construction site from the adjacent site must be submitted. CONCLUSION As the proposed addition appears to meet all requirements, staff would recommend approval, with the following conditions: 1. Drainage calculations must be submitted prior to City Council review. 2. Documentation allowing access to the construction site from the adjacent site must be submitted. 3. Silt fencing shall be staked at the top of the ponding area, rather than on the sides, to prevent erosion. 4. No additional lighting is to be added without review. 5. Landscaping should be completed within one year of issuance of the building permit. OPTIONS 1. Recommend approval of the proposed Site Plan Review, with conditions. 2. Recommend denial of the proposed Site Plan Review. 3. Return to staff with direction. RECOMMENDATION Option #1. \4• N \ \R \ ,4 \ 1.1i./ N.. N., • 'N. ''N \ \ ` \.,,,,,, \ \ 1 .la. l• 5' SEL262( 1 MI \,\ „...., ,,....- --. --- ----° \V::: - -"' / 1; a. Weg NAFFE 9A1 "°FN \ J\ • / '9� /..i¢ST. r \ 4 i( 1 ��. APOLLO \ J 1 .\ 1 \ \ J \ / \ J w.. NCI 1 1 n I 1. 1 !\ \A l 1 \l l /\ 4./ 1 i l_ 1 t \ 1 1 o t 1 1 1 I - ■..• F- ■.0 SDo•OS3e' J90.J7 J I0" EASEMENT f Lot 1 BIoCk -2.- - DOING rFE 9010 \ \ \l*- \ \ _ , / \ _.._ .7 / \ / \ / \\ wt • - \ ` ` —� /J / /— ` -� �r.. 0„...._. / / /MA '807 % /j 1./ \ ..-- --9ol / Z — - — / — / m., w / . ;.1� — — — ,,c _ -.,f / way =:pis �: X�F tw / — .� ., .tv �/ '. .../... / —� loi' J _� — .ma // 0�, / BP 7' / / DTI B Sll'/S 4 %�i' /// �1 t //.4,/.,, , / a,"^ \ �l04 / 5,,52. i/ \ jp::,,'<` f \ \ J\ \ r \ 40 \ \ \ BENCHMARK TOP NUT OF HYDRANT ON NORTH SIDE OF APOLLO DRIVE AS SHOWN HEREON. ELEV = 909.25 FT. (INV= 904.16) DENOTES ELEVATIONS PER AS -BUILT PLANS BY TKDADATED 1996 LEGEND . CATCH BASIN o SANITARY MANHOLE 91 GATE VALVE HYDRANT 01 TELEPHONE PEDESTAL ...A SPOT —AA—STORM SEWER SANITARY SEWER I — WATERMAIN —a.—* CHAIN LINK FENCE CONCRETE CURB CONCRETE �`.. .. • � CONTOUR ■ 19000• =MO 1 x � 1 \ 1 1 // 1 \ /y� \) 1 ,l / / t. 41 20 PARK UDOR USA C I T Y OF LINO LAKES M 1 N N E S 0 1' A SEIEN1ZION DBMS GPM CC RAC7N0 8E MAIN 8TREEI; gym. MIINEAPOUM y �.wry�,yyy �. pin" o°••�iw /.w Y W rA•�1� •r •N,_ ._ mr ens O B-I (9-2 N-1 CO�- MT PLO MOM PLO MIR w1 1 booby catty that W. Olm, gsMeet. at nyat w DM* by Pro sr maw my dreg noonlelol out ow a IM St. .4 remelt 111Na1 1 R 111119 Uenw Ns IMP oats 021E IK2Sw 9- -27 -02 CITY SUBMITTAL )0 -31 -02 PER CITY COMMENTS BUAIITY ll1t112Om1E =Mk DESGN BY' DRAWN BY CHECKED BY: DA's LOUCKS ASSOCIATES N AN* • CI,0 ddmmiK • Lad Saw* Under 4eltl.edle • bylnam OW • 4ei mloo Ilk llo t• ek ICY s= Tapirs M � 1 md110.Amm EXISTING CONDITIONS 94146A CH 000 700.10012.14 SEIDACK °MIN& tilt&DIM PIT MID APOLLO S00.0216T 39a37 ICT EASEMENT D7571MG ADOD7ON 90.69 • .rj.' MJ SULAM PROPOSED ADDITION FFE.• 9019 60' Lot 1 Block 2 1 BUSINESS 552,14 BM BRUM= 22111rA� 7 •1 VALL7 BENCHMARK TOP NUT OF HYDRANT ON NORTH SIDE OF APOLLO DRIVE AS SHOWN HEREON. ELEV = 909.25 FT. (INV=904.16) DENOTES ELEVATIONS PER AS-BUILT PLANS BY TKDADATED 1996 LEGEND MI CATCH BASIN o SANITARY MANHOLE DI GATE VALVE .C) HYDRANT M TELEPHONE PEDESTAL 007.0 SPOT >— STORM SEWER — > SANITARY SEWER I — WATERMAIN —K—I0 CHAIN LINK FENCE CONCRETE CURB jCONCRETE CONTOUR 0 20 1.1 SCALE IN 40 FEET d L t 76, 07 PARK NOTES: LOT AREA ORIGINAL BLDG AREA EXISTING ADDITION AREA PROPOSED ADDITION AREA TOTAL BUILDING AREA EXISTING PAVED AREA 48,672 SQ. FT. 6,042 SQ. FT. 2,400 SQ. FT. 3,600 SQ. FT. 12,042 SQ. FT. 12,335 SQ. FT. PROPOSED PAVED AREA 12,207 SQ. FT. EXISTING IMPERVIOUS AREA 20,777 SQ. FT. PROPOSED IMPERVIOUS AREA 24,249 SQ. FT. EXISTING PERVIOUS AREA 27,895 SQ. FT. PROPOSED PERVIOUS AREA 24,423 SQ. FT. NOTE: 27.74% 25.08% 49.82% 50.18% NO ADDITIONAL LIGHTING WILL BE ADDED TO THE SITE UDO USA CITY OF LINO LAKES MINNESOTA MIN OUPTL CONTRACTP40 219 FE MAN 8114Ea, surrE r IMNEAPOUB,114 85414 012 p.r"=19. 9.4.00 71=r00=0 ow.aw "'goo r r0•0= rp ••• I *a. 0001ore Woo 110 00■10 ok: be Ranh 7.14744 SHER 11122 C1-I C1-1 CO-I U-1 Karmic C01911721111 MI PUN ORPTIOTO RAT [TIM MAN We* colify 94I 01M16291101, ••• me sr mula. 9190.109 991 PPP 2•900T. 1•11.9 Ms Pam 1191991 2 St 1.19 tlunso 2.1.0 9-27-02 PTV MUTT. 10-21-02 PET CATY COMMENTS 01721172 VANA010/XIT 1149312 02290.1 Pr Dam Br CMPC2997 017 DATE LOUCKS ASSOCIATES Phasing • Civil Wm.* • 1.1 Saw* - baited/me • boiromestal • kehmeriap UN babe L. Na. amp/4 Illarla tligire MOM-NU he (10014111 • sow IN hp iN011=1•1NEAM SITE PLAN ZMIECIAO. 941466 C2-1 • • rl IS 1 1 r\ ;1 1 1 T 1 (-IT \A t t \/ 1./ rl 1 1 • I• 1 r— r i vse a ��• �_ v v YOLS a +R PAC 03.9 i F PE 90,19 APOLLO 5100'02 JA'E 390.J7 SILT FENCE" \ \ . O \ \ \ ,6_ 1 \% ._1$) \� ) ) %,o, j -'v i �9D6- _ COMM WI�FOQY Rmm DOM1 PROPOSED-- 'ADDITION F .• 903.9 60' i _".119A- ' ,/ — 1\ rw \ 3 / / / I ■ 902`_ // / \ 1r! X901 / / 1 \1112., °11 �\ tto � f / IIRi 1�j1A Block 2— B14 I/11 'i$S4 SILT FENCE –' --•-1 /� \ / /� / 5�A 5.51 4\N \ 114 BENCHMARK TOP NUT OF HYDRANT ON NORTH SIDE OF APOLLO DRIVE AS SHOWN HEREON. ELEV = 909.25 FT. (INV= 904.16) DENOTES ELEVATIONS PER AS –BUILT PLANS BY TKDADATED 1996 LEGEND 10 CATCH BASIN Q SANITARY MANHOLE DO GATE VALVE Q HYDRANT M TELEPHONE PEDESTAL Me SPOT — »— STORM SEWER SANITARY SEWER — I WATERMAIN CHAIN LINK FENCE CONCRETE CURB CONCRETE �-- 902^1 CONTOUR 20 40 SCALE FEET \ 11 ir, I I r 1 Y\ r • L t V l PARK 1. SET POSTS MO EXCAVATE 4$4' 192) 4 190.19E ALONG TIE UNE OF POSH 3. ATTACH 11€ 4I1ER FABRO 10 THE THE FENCE AND MEND 111410 11* 1EEHCIL 2. STAPLE MA MF/OND TO THE POSTS 4. BAC10E1 AND COMPACT THE SOT. 141e1 CONSIRUC110N OF A AT FENCE AT FENCE MAINTENANCE PROGRAM 1. INSPECTION - AT FENCES SHALL BE MSPECIED IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY 010416 PROLONGED RAINFALL MT REWIRED REPAIRS 9U11 BE MADE M*0)111 LY. 2 REPLACEEENI - FABRIC 94A.1 BE REPLACED PROMPTLY 'WHEN IT DECOMPOSES CR BECOLES MEFFEC11W BEFORE THE BARRIER IS NO LWICE6 FECESSARY. 3. SEDIMENT REMOVAL - SEDIMENT DEPOSITS SHOULD BE REMOLfD AFTER EACH STORM EVENT. DV MUST BE ROOMED MEN DEP0915 REACH APPROXMATELY WE -HALF THE NOWT OF TIE BARMER. SALT FENCE UDOF USA C I T Y O F LINO LAKES MINNESOTA 0 DB4,13 GUM CONTRACTING 215 8E UAI !MEET, BATE Dos IRIEAPOIB, W 854I4 v,w�11 r W Wore y1.1h1yN.w�"Warr� M~ie Y� Mr iyWM wwW M•1w ..111E • r. 111.• MEW ,1119 01 -1 R-1 o-1 C4-1 10011110 mlmenle rflsX 1AM10. motley Pal OY gm 4.10.11. 111 a 1 a1�'p h err :.a ow, ` Pr..* r iw4,�U r M.a d w 51.1• of M1,nrls M..11 .L 31. 11s4I, Um. 11. 0.0 DAR PENSION 1 -27 -02 CITY 0112117 ?AL 0 -31 -02 PER CITY COMMENTS Liman 1UNAaomrr av¢► DESIGN RI DRAWN BY• 111110110:11 Er 01E LOUCKS ASSOCIATES 1 OmNEE • C11il bEiam* • Lod taw* Maim* d1ehltetbe • IN1e...w • dttllWep R 1Tr E.eYd 1.e• •11 MA 0111 ( MO• GRADING, DRAINAGE & EROSION CONTROL PLAN PBOEGIJ6 94146A C3 -1 NOS S00'02'J0 £ 390.37 10' EASEMENT • "° ms`s 9 VOTING ACVMON /FE 90.110 APOLLO PROPOSED m ADDITION FFE- 903.9 SA mums -34 60' BUSINESS enemas same \ BENCHMARK TOP NUT OF HYDRANT ON NORTH SIDE OF APOLLO DRIVE AS SHOWN HEREON. ELEV = 909.25 FT. (INV= 904.16) DENOTES ELEVATIONS PER AS -BUILT PLANS BY TKDADATED 1996 CATCH BASIN O SANTARY MANHOLE IM GATE VALVE .0 HYDRANT T TELEPHONE PEDESTAL ..m.. SPOT >>-- STORM SEWER SANITARY SEWER WATERMAIN -- • CHAIN LINK FENCE CONCRETE CURB CONCRETE CONTOUR \ SCALE IN FEET I n 1 i T 1 Al T PARK NOTE: UTILITY EXTENSIONS TO PROPOSED ADDITION PROVIDED FROM EXISTING BUILDING AS NEEDED. UDO USA CITY OF LINO LAKES M I N N E S O T A DENNIS OUPTL CONTRACTING SURE 306 hoodoo IANNEAPOUB, IAN 5664 d 002 IIr.1t 1 or ly Mar*. or ropOrt I ra M' 1b.1 F1* Erroboor mi . IM 4w M No SW* M I&* 4 Michael i x •.n Um.. Ir Use MAN 0910 REM O* 9 -27 -02 CITY SUBMITTAL 10 -31 -02 PER CITY COMMENTS 90*210 11.09■iemlt .1900. DESIGN 131, CHEMED He DRAWN 9 DIM OUCKS ASSOCIATES 1 A•••W • OBI Oda+U[ • Wd Wimp /alUseh.. • 6lhmamW • Areaway 1111BWet -•tlb1 k MINNA • woo IM M. N. en UTILITY PLAN PBOIBGL110. 94148A C4 -1 OR ,GP•MLW CUMIN r NJ s t 1 4' rl l. \A t t ',/ 1 r'N I I . I • I I" r a r. !' it • IS1 1 I I S0O.O2'36 390.37 1] -- — ,o' Sf / / ± ;"• 9Y7MAL &LAM •t.= Nf MOIR Qp / / \ i =; APOLLO 1 t Lot 1 ,_.__\ `'\ DISTINO ADDITION FFE MIA ■ ...,,.; , } J _ / • *;:' };"���Vj ice% =1—` I // .110 , /,�A� tob B (�l S .l ,S j I `. 11 T I /1 T \A l l \J 1 •wt NIL .b) SYMIQTY1 COMMON NAME 'SCIENTIFIC NAME 1 SIZE 1 CONT 1 COMMENTS DECIDUOUS TREES PO 2 NORTHERN PIN OAK NM Quercus elliosoldalls 2" CAL B &B SINGLE STEM 3 NORTHWOOD RED MAPLE Acer rubrum 'Northwood' 2" CAL B &B SINGLE STEM EVERGREEN TREES BH NP 3 BLACK HILLS SPRUCE 3 NORWAY PINE Picea alauca densata Pinus resinoso 6' HGT 6' HGT B &B B &B FULL FORM FULL FORM PLANT SCHEDUL --- -� - \-" 903_ - ILJ/ \ -�� "..,/ or- \ // - -- ▪ / MA H. THE CONTRACTOR IS RESPONSIBLE FOR POSITION 1 THROOUUG TREES IN B PERIOD. STAKING IS SUGGESTED BUT NOT REQUIRED. ANY STAKING MUST CONFORM WITH PRACTICES AS DEFINED IN A.N.A. GUIDEUNES FOR STANDARD PRACTICES PRUNE DAMAGED AND CROSSING BRANCHES AFTER PLANTING IS COMPLETE. REMOVE ALL FLAGGING AND LABELING TREE. WATER TREE THOROUGHLY DURING PLANT1NQ OPERATIONS. PLACE BACKFILL IN 8-12 UFTS AND SATURATE SOIL W1TH WATER. DO NOT COMPACT MORE THAN NECESSARY TO MAINTAIN PLUMB. 16 "N2" POLYPROPYLENE OR POLYETHYLENE STRAP TREE WRAP TO FIRST BRANCH SAFETY FLAGGING - ONE PER WIRE MULCH - 4- DEEP - PER SPEC. PLANTING SOIL - PER SPEC. WOOD STAKE (OPTIONAL) EDGE VARIES - SEE PLAN SCARIFY BOTTOM AND SIDES OF HOLE PRIOR TO PLANTING ROOT BALI. SET ON MOUNDED SUBGRADE CONTRACTOR IS RESPONSIBLE FOR TESTING PERCOLATION RATES PRIOR TO PLANTING. NOTIFY LANDSCAPE ARCHITECT IMMEDIATELY IF POOR DRAINAGE EXISTS DECIDUOUS TREE PLANTING DETAIL SCALE: 1/2" - PLANTING DETAIL Deciduous Tre&DW ALL UNDERGROUND UTILITIES SHALL BE LAID SO THAT TRENCHES DO NOT CUT THROUGH ROOT SYSTEMS OF ANY EXISTING TREES TO REMAIN. WHERE EXISTING TREES AND/OR SIGNIFICANT SHRUBS MASSINGS ARE FOUND ON SITE, WHETHER SHOWN ON THE DRAWING OR NOT, THEY SHALL BE PROTECTED AND SAVED UNLESS NOTED TO BE REMOVED AND /OR ARE IN AN AREA TO BE GRADED. ANY QUESTION REGARDING WHETHER PLANT MATERIAL SHOULD REMAIN OR NOT SHALL BE BROUGHT TO THE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO REMOVAL NO PLANTING WILL BE INSTALLED UNTIL COMPLETE GRADING AND CONSTRUCTION HAS BEEN COMPLETED IN THE IMMEDIATE AREA. SEED ALL AREAS DISTURBED DUE TO GRADING OTHER THAN THOSE AREAS NOTED TO RECEIVE SOO. SEED SHALL BE INSTALLED AND MULCHED AS PER MNDOT SPECS. ALL PLANT MATERIAL SHALL COMPLY WITH THE LATEST EDITION OF THE AMERICAN STANDARD FOR NURSERY STOCK, AMERICAN ASSOCIATION OF NURSERYMEN. UNLESS NOTED OTHERWISE, DECIDUOUS SHRUBS SHALL HAVE AT LEAST 5 CANES AT THE SPECIFIED SHRUB HEIGHT. ORNAMENTAL TREES SHALL HAVE NO V CROTCHES AND SHALL BEGIN BRANCHING NO LOWER THAN 3' ABOVE ROOT BALL STREET AND BOULEVARD TREES SHALL BEGIN BRANCHING NO LOWER THAT 6' ABOVE FINISHED GRADE. ALL PROPOSED PLANTS SHALL BE LOCATED AND STAKED AS SHOWN ON PLAN. LANDSCAPE ARCHITECT MUST APPROVE ALL STAKING OF PLANT MATERIAL PRIOR TO ANY AND ALL DIGGING. NO PLANT MATERIAL SUBSTITUTIONS WILL BE ACCEPTED UNLESS APPROVAL IS REQUESTED OF THE LANDSCAPE ARCHITECT BY THE LANDSCAPE CONTRACTOR PRIOR TO THE SUBMISSION OF A 81D AND /OR QUOTATION. ALL PLANT MATERIALS SHALL BE FERTILIZED UPON INSTALLATION WITH DRIED BONE MEAL, OTHER APPROVED FERTILIZER MIXED IN WITH THE PLANTING SOIL PER THE MANUFACTURER'S INSTRUCTIONS OR MAY BE TREATED FOR SUMMER AND FALL INSTALLATION WITH AN APPUCATION OF GRANULAR 0 -20 -20 OF 12 OZ PER 2.5" CALIPER PER TREE AND 6 OZ PER SHRUB WITH AN ADDITIONAL APPUCATION OF 10 -10 -10 THE FOLLOWING SPRING IN THE TREE SAUCER. ALL PLANTS TO BE INSTALLED AS PER PLANTING DETAILS. WRAPPING MATERIAL SHALL BE CORRUGATED PVC PIPING 1" GREATER IN CAUPER THAN THE TREE BEING PROTECTED OR QUALITY, HEAVY, WATERPROOF CREPE PAPER MANUFACTURED FOR THIS PURPOSE. WRAP ALL DECIDUOUS TREES PLANTED IN THE FALL PRIOR TO 12 -1 AND REMOVE ALL WRAPPING AFTER 5 -1. ALL EVERGREEN TREES TO RECEIVE 4" DEEP SHREDDED HARDWOOD MULCH WITH NO MULCH IN DIRECT CONTACT WITH TREE TRUNK. IF THE LANDSCAPE CONTRACTOR IS CONCERNED OR PERCEIVES ANY DEFICIENCIES IN THE PLANT SELECTIONS, SOIL CONDITIONS OR ANY OTHER SITE CONDITION WHICH MIGHT NEGATIVELY AFFECT PLANT ESTABUSHMENT, SURVIVAL OR GUARANTEE, HE MUST BRING THESE DEFICIENCIES TO THE ATTENTION OF THE LANDSCAPE ARCHITECT PRIOR TO PROCUREMENT AND /OR INSTALLATION. CONTRACTOR SHALL GUARANTEE NEW PLANT MATERIAL THROUGH ONE CALENDAR YEAR FROM THE DATE OF OWNER ACCEPTANCE. WARRANTY (ONE FULL GROWING SEASON) FOR LANDSCAPE MATERIALS SHALL BEGIN ON THE DATE OF ACCEPTANCE BY THE LANDSCAPE ARCHITECT AFTER THE COMPLETION OF PLANTING OF ALL LANDSCAPE MATERIALS. NO PARTIAL ACCEPTANCE WILL BE CONSIDERED. CONIFEROUS PLANTING MAY OCCUR FROM AUGUST 15 - OCTOBER 1 AND FALL DECIDUOUS PLANTING FROM THE FIRST FROST UNTIL NOVEMBER 15. PLANTING OUTSIDE THESE DATES IS NOT RECOMMENDED. ANY ADJUSTMENT MUST BE APPROVED IN WRITING BY THE LANDSCAPE ARCHITECT. PROTECT ALL EXISTING OAKS ON SITE SCHEDULED TO REMAIN. IF EXISTING OAKS ARE DAMAGED IN ANY MANOR ABOVE OR BELOW GROUND IN THE ROOT SYSTEM, AN ASPHALTIC TREE PRUNING PAINT SHOULD BE APPUED IMMEDIATELY AFTER WOUNDING. OAKS ARE NOT TO BE PRUNED, REMOVED OR TRANSPLANTED BETWEEN APRIL 15 AND JULY 1. NOTIFY LANDSCAPE ARCHITECT IF THESE DATES ARE UNAVOIDABLE. PLANTING NOTES UDO USA C I T Y O F LINO LAKES M I N N E S O T A DENNIS OUPTL CONTRACMo 2111 8E MAN STREET, BUTS 908 MNE.APCLB, MN 55414 a:afr. r .. ur"ap/=% c"""am lr. 7p.°` -µms -r` tor. r vM.....v Tma COMM culmBLme sm PUS GRAMM mum PLAN MUTT PLAN LANGSC.PS P.M I IM*•Y erbry Mal qM put tp.pMmllm or noted e pnp* by not or u,dr my *. t wato0M." tool bat I so • aAr LMard Lto,M1C,q. AMilsl u.d tM Iew N Dot SU. of Idbm.. . PRA Pt -e - e � L1.a*• Ne D ATE IIEVmO4 9 -27 -02 CITY SUBMITTAL 10 -31 -02 PER CITY COMMENTS •UYlrf MABAOOmR 1111TYc DESIGN BC DRAWN 0* CHECKED Br MrE LOUCKS ASSOCIATES Thu* • aril k Io.o ng • IOU Surveying Wkye 4tlitedme • k.io,. atU • 4eNm4o0 ,r ink& 1.2 .NN Me 12•2•112 NI* .M►� • MM T'I'C IN N s LANDSCAPE PLAN 94148A L1 -1