Laserfiche WebLink
I'l 1E CITYOF <br />LA rK/ E <br />maw""MMOW111- <br />16ONNOW.:- <br />containing a rooming house, housekeeping units, a hotel, a dormitory, two or <br />more dwelling units or two or more nonresidential occupancies, shall maintain, in <br />a clean and sanitary condition, the shared or public areas of the structure and <br />exterior property, <br />The interior of the property is not maintained in good repair, it is not structurally <br />sound and is unsanitary. <br />3. 305.2 Structural members. All structural members shall be maintained <br />structurally sound; and be capable of supporting the imposed loads. <br />Tile prqp� is not being In aintained structurally sound or capable of support* <br />imposed loads. <br />4. 3051 Interior Surfaces. All interior surfaces, including windows and doors, shall <br />be maintained in good, clean and sanitary condition. Peeling, chipping, flaking or <br />abraded paint shall be repaired, rernoved or covered. Cr4ciced or loose plaster, <br />decayed wood and other defective surface conditions shall be corrected. <br />Interior surfaces, windows, doors, interior walls and n4shes are not being <br />maintained in clean and sanitary condition. <br />5. 305.4 Stairs and walking surfaces. Every stair, ramp; landing, balcony, porch, <br />deck or other walking surface shall be maintained in sound condition and good <br />repair. <br />Stairs to the secondfloor are not maintained in sound condition and good repair. <br />The stairs to the basement level are inaccessible, the stairway isfilled with debris <br />making the area inaccessible. <br />6� 305.5 Handrails and guards. Every handrail and guard shall be firmly fastened <br />and capable of supporting normally imposed loads and shall be maintained in <br />good condition. 306.1 General. Every exterior and interior flight of stairs having <br />more than four risers shall have a handrail on one side of the stair and every open <br />portion of a stair, landing, balcony, porch, deck, rasp or other walking surface <br />which is more than 30 inches (762 nun) above the floor or grade below shall have <br />guards. Handrails shall not be less than 30 inches (762 min) high or more than 42 <br />inches (1067 min) high measured vertically above the nosing of the tread or above <br />the finished floor of the landing or walking surfaces. Guards shall not be less than <br />30 inches (762 min) high above the floor of the landing, balcony, porch, deck, or <br />ramp or other walking surface. <br />Handrails and guardrails are missing where required, <br />3800 Laverne Avenue North * Lake Elmo * Minnesota * 55042 * 651,7473900 <br />