'ri IE CITY OF <br />LAKE T-*""LMO <br />505.4 Water beating facilities. Water heating facilities shall be properly <br />installed, maintained and capable of providing an adequate amount of water to be <br />drawn at every required sink, lavatory, bathtub, shower and laundry facility at a <br />temperature of not less than 1 loop (43°C), A gas -burning water heater shall not <br />be located in any bathroom, toilet room, bedroom or other occupied room <br />normally Dept closed, unless adequate combustion air is provided. An approved <br />combination temperature and pressure -relief valve and relief valve discharge pipe <br />shall be properly installed and maintained on water heaters. <br />The home does not have running water, plumbing, Heated water or f tur es. <br />12.506.1 General. All plumbing fixtures shall be properly connected to either a <br />public sewer system or to an approved private sewage disposal system: <br />The home is not connected to a sewage system. <br />1 .602 2 Residential occupancies. Dwellings shall be provided with heating <br />facilities capable of maintaining a room temperature of6°F (20°C) in all <br />habitable rooms, bathrooms and toilet rooms based on the winter outdoor design <br />temperature for the locality indicated in Appendix D of the International <br />Plumbing Code. Cooling appliances shall not be used to provide space heating t <br />meet the requirements of this section. <br />602.5 Room temperature measurement. The required room, temperatures shall <br />be measured 3 feet (914 rom) above the floor near the center of the room and. <br />feet (610 rom) inward from the center of each exterior wall, <br />:e bore does not have heating facilities capable of maintaining z required <br />temperature as required. <br />14.604.1 Facilities required. Every occupied building shall be provided with an <br />electrical system in compliance with the requirements of this section and Section <br />605. <br />604.3 Electrical system' hazards. Where it is' found that the electrical system in <br />a structure constitutes a hazard to the occupants or the structure by reason o <br />inadequate service, improper fusing, insufficient receptacle and lighting outlets, <br />improper wiring or installation; deterioration or damage, or for similar reasons; <br />the code official shall require the defects to be corrected to eliminate the hazard.., <br />605.1 Installation. All electrical equipment, wiring and appliances shall be <br />properly installed and maintained in a safe and approved manner, <br />605.2 .Receptacles. Every habitable space in a dwelling shall contain at least two <br />separate' and; remote receptacle outlets. Every laundry area shall contain at least <br />one grounded -type receptacle or a receptacle with a, ground fault circuit <br />interrupter. Every bathroom shall contain at least one receptacle. Any new <br />bathroom receptacle outlet shall have ground fault circuit interrupter protection, <br />3800 Laverne ;Avenue North * Lake Elmo * Minnesota * 55042 * 5j1,7 i7,3 {}0,., <br />
The URL can be used to link to this page
Your browser does not support the video tag.