Laserfiche WebLink
-ri tuz- clrn, ot, <br />LAKE ELMO <br />2. Foundation is caving in east side of home below grade. Block foundation grout is <br />missing at the concrete block foundation, block is cracked and is caving in along <br />the east wall. (Exhibit 2, Exhibit 3, Exhibit 4 & Exhibit 5) <br />3. The sill and floor joist area of the main floor east wall is exposed to the weather, <br />no siding or protective weather barrier nor is flashing present in any area along <br />the east wall. The main floor system rim and joists are rotted and structural <br />integrity is compromised on the east exterior wall. (See Exhibit 3 & Exhibit 5) <br />4. The double hung window to the north of the electric meter on the east wall is <br />rotted and falling into the house. There is no flashing present, the wood is rotted <br />and not weather tight. (See Exhibit 6, Exhibit 8 & Exhibit 9) <br />5. The siding and trim boards on the east wall of the house is rotted and does not <br />extend to the top of the wall, (See Exhibit 10 & Exhibit 11) <br />North Side Exterior <br />1. Foundation grout is missing at the concrete block foundation, block is cracked <br />and is separating along the length of the north wall, (See Exhibit 12) <br />2. Structural framing of the wood -frame floor system and walls above foundation is <br />not flashed or weather tight.(See Exhibit 12) <br />3. Door opening on the north wall is missing the door, plywood pieces nailed over <br />opening from the interior. Opening is not weather tight. Structural framing at the <br />floor framing is rotted at the door opening. (See Exhibit 12) <br />4. Window opening on the north wall is missing the window, plywood has been <br />nailed over the opening from the interior. Opening is not weather tight. (See <br />Exhibit 12) <br />5. Exterior sheathing is missing along the north wall near the window opening. (See <br />Exhibit 12) <br />6. Siding and trim missing from the north wall, sheathing is exposed to the weather <br />and approx. top half of the exterior wall is not flashed or protected from the <br />weather or weather tight.(See Exhibit 12) <br />7. Window at the top of the wall is not flashed or weather tight.(See Exhibit 12) <br />West Side Exterior <br />1. West patio door is not weather tight in opening, exterior siding, trim and flashing <br />is missing, the opening is not weather tight. (See Exhibit 13 & Exhibit 14) <br />2. Foundation grout is missing at the concrete block foundation, block is cracked <br />and is separating along the length of the north wall, Multiple location block is <br />3800 Laverne Avenue North * Lake Eirno * Minnesota * 55042 * 651347,3900 <br />