My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
#19 - Roers LE Multifamily Final Plat
LakeElmo
>
City Council
>
City Council Meeting Packets
>
2020's
>
2024
>
11-19-24
>
#19 - Roers LE Multifamily Final Plat
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2025 4:34:06 PM
Creation date
4/1/2025 11:59:44 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROPOSED BUILDING <br />13,150 S.F. <br />FFE=1023.00 <br />G <br />HUDSON BOULEVARD N <br />EXISTING R.O.W. (VARIES) <br />100' <br />EXISTING <br />R.O.W. <br />HUDSON BOULEVARD N <br />OUTLOT B JULIA AVE N4 <br />T <br />H <br /> <br />S <br />T <br />R <br />E <br />E <br />T <br /> <br />N <br />O <br />R <br />T <br />H <br />PROPOSED BUILDING <br />49,417 S.F. <br />FFE=1022.00 <br />T <br />T <br />VAN <br />GFE=1011.00 <br />WET POND 3P <br />FILTRATION BASIN 15P <br />FILTRATION BASIN 14P FILTRATION BASIN 13P FILTRATION BASIN 12P <br />FILTRATION BASIN 11P <br />INFILTRATION BASIN 7P <br />FILTRATION BASIN 1P <br />STORMWATER <br />POND <br />HWL=1000.30 <br />LOT 1 <br />LOT 2 <br />INFILTRATION BASIN 4P <br />IRRIGATION SYSTEM <br />CONTROLS ENCLOSURE <br />REUSE IRRIGATION <br />PUMP INTAKE <br />PUMP STATION/ENCLOSURE <br />SCALE IN FEET <br />0 10050 <br />NORTH <br />NO DATE BY CKD APPR SHEET <br />OF <br />Date License # <br />Print Name: <br />I hereby certify that this plan, specification, or report <br />was prepared by me or under my direct supervision and <br />that I am a duly Licensed Professional Engineer under <br />the laws of the State of Minnesota. <br />DRAWN BY <br />DESIGNED BY <br />CHECKED BY <br />PROJECT NO. <br />PRELIMINARY <br />DESIGN REVIEW <br />PERMIT SUBMITTAL <br />CONSTRUCTION DOCUMENTS REV. <br />COMMENT <br />Engineering | Surveying | Planning | Environmental <br />24.1S (LMS TECH) | JOSEPH BAILEY | 9/12/2024 11:59:25 AML:\PROJECTS\53062\CAD\CIVIL\SHEETS\53062-C6-UTIL C3.04, C6.01-C6.05.DWG:C6.01 OVERALL UTILITY PLANROERS LAKE ELMO, LLC <br />LAKE ELMO APARTMENTS <br />LAKE ELMO, MN <br />75 <br />53062 <br />12/02/2021 <br />04/18/2022 <br />09/13/2024 <br />EAB <br />TLL <br />JDB <br />JOSEPH D. BAILEY <br />04/27/2023 58645 <br />09/13/2024 TTP MCA JDB PERMIT SET <br />08/07/2024 TTP MCA JDB PUD SUBMITTAL OVERALL UTILITY PLAN C6.01 <br />25 <br />THE SUBSURFACE UTILITY INFORMATION SHOWN ON THESE PLANS IS A UTILITY QUALITY LEVEL D. THIS QUALITY LEVEL WAS DETERMINED ACCORDING TO THE GUIDELINES OF ASCE/CI 38-02, <br />TITLED "STANDARD GUIDELINES FOR THE COLLECTION AND DEPICTION OF EXISTING SUBSURFACE UTILITY DATA." THE CONTRACTOR AND/OR SUBCONTRACTORS SHALL DETERMINE THE EXACT <br />LOCATION OF ALL EXISTING UTILITIES BEFORE COMMENCING WORK, BY CONTACTING THE NOTIFICATION CENTER (GOPHER STATE ONE FOR MINNESOTA). THE CONTRACTOR AND/OR <br />SUBCONTRACTOR AGREE TO BE FULLY RESPONSIBLE FOR ANY AND ALL DAMAGES, WHICH MIGHT BE OCCASIONED BY HIS OR HER FAILURE TO EXACTLY LOCATE AND PRESERVE ANY AND ALL <br />UTILITIES (UNDERGROUND AND OVERHEAD). <br />IF THE CONTRACTOR ENCOUNTERS ANY DRAIN TILE WITHIN THE SITE, HE OR SHE SHALL NOTIFY THE ENGINEER WITH THE LOCATION, SIZE, INVERT AND IF THE TILE LINE IS ACTIVE. NO DRAIN TILE <br />SHALL BE BACKFILLED WITHOUT APPROVAL FROM THE PROJECT ENGINEER. <br />IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. <br />PROPOSED EXISTING <br />LEGEND <br />PUBLIC SANITARY <br />SEWER <br />FORCEMAIN (SAN.) <br />STORM SEWER <br />DRAINTILE <br />PRIVATE WATERMAIN <br />UNDERGROUND <br />GAS LINE <br />UNDERGROUND <br />TELEPHONE <br />UNDERGROUND <br />ELECTRIC <br />CONCRETE CURB <br />EASEMENT LINE <br />UTILITY CONSTRUCTION NOTES <br />SEE NOTES AND CASTING TABLE ON PAGE C6.06 <br />PUBLIC WATERMAIN <br />PRIVATE SANITARY <br />SEWER <br />START PRIVATE <br />SANITARY SERVICE <br />AFTER MANHOLE <br />PRIVATE <br />SANITARY <br />SERVICE <br />PUBLIC <br />SANITARY <br />PUBLIC <br />SANITARY <br />START PRIVATE <br />WATER SERVICE <br />AFTER GATE VALVE <br />PUBLIC <br />WATERMAIN <br />PUBLIC <br />WATERMAIN <br />PUBLIC <br />WATERMAIN <br />PUBLIC <br />WATERMAIN <br />START PRIVATE <br />WATER SERVICE <br />START PRIVATE <br />SANITARY SERVICE <br />AFTER MANHOLE <br />PRIVATE <br />SANITARY <br />SERVICE
The URL can be used to link to this page
Your browser does not support the video tag.