Laserfiche WebLink
OFFICE OF ENVIRONMENTAL STEWARDSHIPDAVID LARSON <br />DATE PRINTED:PROJECT MANAGER DRAWN BY <br />TRANSPORTATION BUILDING <br />STATE OF MINNESOTA <br />DEPARTMENT OF TRANSPORTATION <br />ST. PAUL, MINNESOTA 55155-1899MINNESO <br />TA <br />DE <br />P <br />A <br />R <br />T <br />MEN <br />T <br />OF TRANSPOR <br />T <br />A <br />T <br />I <br />O <br />N <br />OFFICE OF ENVIRONMENTAL STEWARDSHIP <br />ENV. PLANNING AND DESIGN UNIT <br />SHEET NO.OF SHEETS9 <br />STANDARD PLANTING DETAILS (C) <br />9STATE PROJECT SP 1901-171 (T.H. 13) <br />'2 <br />10'8 <br />51 <br />8' FOR CONIFEROUS TREES <br />5' FOR DECIDUOUS TREES <br />CHART ON STANDARD PLANTING DETAILS (B) <br />MINIMUMS FROM THE PLANTING HOLE DIMENSIONS <br />HOLE EXCAVATION WIDTH IN ACCORDANCE WITH <br />PLANTING DETAILS (A) <br />DETAIL SEE STANDARD <br />FOR PLANTING SOIL <br />PLANT SPACING IN MASS BEDS <br />PLANTING DETAIL (B) <br />SEE STANDARD <br />FOR MULCH DETAIL <br />INSTALL GRANULAR FILTER <br />INSTALL TILE DRAINAGE <br />' <br />8 <br />3 <br />0 <br /> GRADE.FINISHED <br /> THAN HIGHER 1"-3" MASS ROOT OF TOP THE PLACING ALLOW TO BED OR HOLEEXCAVATE1. <br /> SUBSOIL. DRAIN ADEQUATELY TOLAYER <br /> SOIL PAN HARD DRAINED POORLY OR IMPERVIOUS THROUGH ENTIRELY HOLES DIAMETER 8"AUGER2. <br />DRAINAGE. <br /> POSITIVE FOR NECESSARY IF 8" ADDITIONAL AN RE-AUGER DRAINAGE. POSITIVE FORTEST3. <br /> SOIL. INPLACE 50%AND <br /> SAND 50% OF MIXTURE INCORPORATED UNIFORM A WITH HOLES AUGER BACKFILLTHOUROUGHLY4. <br /> (B). DETAILS PLANTING STANDARD SEE TYPE.ROOT TO ACCORDING PLANTINGCOMPLETE5. <br /> GRADE. FINISHED THANHIGHER <br /> 1"-3" MASS ROOT THE OF TOP THE PLACING ALLOW TO BED OR HOLEEXCAVATE1. <br /> GRADE. LOWER A AT DAYLIGHTING TILE DRAIN DIAMETER MINIMUM 4"INSTALL2. <br />). (B DETAILS PLANTING STANDARD SEE TYPE.ROOT TO ACCORDING PLANTINGCOMPLETE3. <br />INSTALL MINI-BERM <br />NOTE: <br /> APPROVAL.ENGINEER <br /> TO SUBJECT CONTRACTOR, THE BY DETERMINED ARE USE TO TYPEWHICH <br /> AND SOILS DRAINED POORLY FOR DETAILS PLANTING USING FOR NEEDTHE1. <br /> MASS. ROOT THE OF DEPTH THE 1/4 BED OR HOLEEXCAVATE1. <br /> HOLE. IN MASS ROOTSET2. <br /> HEIGHT. BERM THETIMES <br /> 3 OF WIDTH A TO BASE BERM THE EXTEND. SOILPLANTING WITH BERMCONSTRUCT3. <br /> (B). DETAILS PLANTING STANDARD SEE TYPE.ROOT ACCORDING PLANTINGCOMPLETE4. <br />PLANTING DETAIL FOR POORLY DRAINED SOILS <br />M <br />A <br />S <br />S <br />R <br />O <br />O <br />T <br />1/4 <br /> <br />HOLES <br />8" AUGER <br />TILE <br />4" DRAIN <br />PLANTING DETAILS (A) <br />DETAIL SEE STANDARD <br />FOR PLANTING SOIL <br />PLANTING DETAILS (A) <br />DETAIL SEE STANDARD <br />FOR PLANTING SOIL <br />PLANTING DETAILS (A) <br />DETAIL SEE STANDARD <br />FOR PLANTING SOIL <br />PLANTING DETAIL (B) <br />SEE STANDARD <br />FOR MULCH DETAIL <br />PLANTING DETAIL (B) <br />SEE STANDARD <br />FOR MULCH DETAIL <br />PLANTING DETAIL (B) <br />SEE STANDARD <br />FOR MULCH DETAIL <br />(MnDOT 2571.3D2 (STEP 8) <br />NOTE: <br /> BASIN. WATERING THE OF HALF UPHILLTHE <br /> CONSTRUCT NOT DO GREATER, OR SLOPES 1:2ON1. <br />CUT AREA <br />EXISTING GRADE <br />WATER BASIN <br />UPHILL HALF <br />WATER BASIN <br />DOWN HILL HALF <br />PLANTING DETAILS (A) <br />DETAIL SEE STANDARD <br />FOR PLANTING SOIL <br />DETAILS (B) <br />SEE STANDARD PLANTING <br />ROOT TYPE. <br />PLANT ACCORDING TO <br />PLANTING ON SLOPES <br />HOLD WATER IN BASIN. <br />SOIL RIDGE TO <br />PLANTING DETAIL (B) <br />SEE STANDARD <br />FOR MULCH DETAIL <br /> RIM. TOPOUTWARD-FLARED <br /> AN ANDPERFORATION <br /> LINE LASER A WITHTUBES <br /> POLYPROPYLENETRANSLUCENT <br /> SEMI AND RIGIDTWIN-WALL, <br /> EXTRUDED, SEAMLESS,USE1. <br />TWISTING. <br /> OR DISLODGINGPREVENT <br /> TO STAKE OAK WHITE 1''x <br /> 1'' A TO ATTACHED-TIESCABLE <br /> NYLON WITH SHELTERSECURE2. <br /> ROOTS. TREE THEDISTURBING <br /> WITHOUT SURFACE SOILTHE <br /> BELOW 1'' OF MINIMUM ATUBE <br /> THE OF BOTTOM THEEMBED3. <br /> SHOWN. AS DOWNNETTING <br /> PULL TUBE. THE OFTOP <br /> THE OVER SLEEVE ANDCOVER <br /> NETTINGPHOTODEGRADABLE <br /> PLASTIC AINSTALL4. <br />" <br />8 <br />7 <br />2 <br />' <br />- <br />0 <br />1' <br />- <br />0 <br />" <br />"4 <br />31'-5 <br />1' <br />- <br />9 <br />" <br />1' <br />- <br />0 <br />" <br />SEEDLING TREE SHELTER <br />2 <br />' <br />- <br />0 <br />" <br /> <br />M <br />IN <br />. <br />12 <br />" <br /> <br />T <br />O <br /> <br />14 <br />" <br />PREVAILING WIND <br />RECESS <br />FORMED TUBE <br />SECURE STAKE IN <br />CABLE-TIE TO <br />(LENGTH VARIES) <br />STAKE <br />TUBE SHELTER <br />PERFORATION <br />LASER LINE <br />NETTING <br />(MnDOT 2571.3I4) <br />RODENT PROTECTION <br /> 15" <br />WIRE MESH <br />STAKE <br />CONIFEROUS TREES <br />12" MIN. HT. FOR <br />DECIDUOUS TREES <br />24" MIN. HT. FOR <br /> 2". END CUT THE OVERLAPCLOTH). <br /> (HARDWARE MESH WIRE WELDED GALVANIZED GRID 0.25" USING CYLINDER DOUBLE-LAYERED AFORM1. <br /> STEM. TREE THE OFCENTER <br /> THE FROM 7", GROUND THE INTO STAKES OAK WHITE HEARTWOOD OPPOSING 1" x 1" TWODRIVE2. <br /> OVERLAP. THE ALONG CENTER ON 4" APPROXIMATELY SPACE OVERLAP. THE ALONG-TIESCABLE OR <br /> WASHERS AND SCREWS EITHER, USING STAKES THE OF OUTSIDE THE TO CYLINDER MESH THESECURE3. <br /> WASHERS. WITH LONG 3/4" x DIA. 1/8" GALVANIZED HEAD ROUND BE SHALLSCREWSa. <br />OR <br />.STRENGTH <br /> TENSILE 120LB TO 75LB BETWEEN AND LONG 8" LEAST AT, NYLON BE SHALLTIES-CABLEb. <br /> ROOTS. TREETHE <br /> DISTURBING WITHOUT SURFACE SOIL THE BELOW 1" CYLINDER MESH THE OF EDGE LOWER THEEMBED4. <br /> CYLINDER. THE OF TOPTHE <br /> WITH FLUSH BE WILL STAKE CYLINDER. THE OF TOP THE AT PERMITTED BE NOT WILL EDGESCUT5. <br /> DETAIL. PLACEMENT MULCH IN SPECIFIED ASTRUNK <br /> THE FROM BACK PULLED BE SHALL AND DEPTH 3" EXCEED NOT SHALL CYLINDER THE WITHINMULCH6. <br /> GUARDS. RODENT HEIGHT MIN. 12" OFINSTALLATION <br /> PERMIT TO REMOVED BE TO HAVE MAY BRANCHES LARCH AND PINE OF WHORL BOTTOMTHE7. <br /> TREES. SPRUCE ONPLACE NOT DO TREES, LARCH AND PINE DECIDUOUS, ALL ONINSTALL8. <br />(MnDOT 2571.3I2) <br />' <br />81 <br />4 <br />' <br />21 <br />4 <br />' <br />21 <br />2 <br />' <br />8 <br />3 <br />2 <br />STAKING AND GUYING <br /> SIZING POSTSTEEL <br />CALIPER TYPE POSTSTEEL A B C D <br /> INCHES4 <br /> THENLESS <br />7'-0"MIN. <br />3'-0" <br />4'-0"3'-0" <br />INCHES <br /> 4THEN <br />GREATER <br />10'-0" <br />MIN. <br />4'-0" <br />6'-0"5'-0" <br /> <br />A <br /> <br /> <br />B <br /> <br /> <br />C <br /> <br /> <br />D <br /> <br />SLOPE. <br /> GROUND OFREGARDLESS <br /> PLUMB DRIVE BALL.ROOT <br /> OF OUTSIDE PLACEWIRES. <br /> GUY RETAIN TO DRILLEDOR <br /> NOTCHED BE TO POSTSTEELS1. <br /> APPROVED.BE <br /> NOT WILL SYSTEMSGUYING <br /> WIRE AND HOSERUBBER <br /> SUBSTITUTE TOREQUESTS2. <br /> YEAR. ONEWITHIN REMOVE4. <br />10 ga WIRE. <br />STRAPS. ATTACH WITH <br />THICK AND 1.5" WIDE <br />POLYETHYLENE, 40 MIL. <br />POLYROPYLENE OR <br />16" LONG <br />SEE CHART <br />STEEL POST <br /> BY THE ENGINEER. <br /> PROBLEM, OR AS DIRECTED <br /> WIND CONDITIONS ARE A <br /> WHERE VANDALISM, SOIL, OR <br /> TREES IN A PLUMB CONDITION <br /> OR NECESSARY TO MAINTAIN <br /> REQUIRED UNLESS SPECIFIED <br />3. TREE STAKING IS NOT <br />OR APPROVED EQUAL. <br />POST (MnDOT 3401) <br />CHANNEL STEEL SIGN <br />10', 2.2 LB. FLANGED <br />(MnDOT 2571.3I1) <br />OR APPROVED EQUAL. <br />POST (MnDOT 3403) <br />ROLLED STEEL FENCE <br />REVISED - JANUARY / 01 / 2014