Laserfiche WebLink
  <br />    PAGE 1 of 2  <br />  <br />MEMORANDUM  <br />Date:  December 16, 2024  <br />  <br />  <br />  <br />To:  Sophia Jensen, City Planner  Re:  Chavez Variance Application   <br />Cc:  Chad Isakson, P.E., Assistant City Engineer    PID 14‐029‐21‐42‐0002 (Northstar Outlot B)  <br />From:  Jack Griffin, P.E., City Engineer    Engineering Review Comments  <br />  <br />  <br />An engineering review has been completed for the Chavez Variance Applications for PID 14‐029‐21‐42‐0002.  <br />  <br />  <br />STATUS/FINDINGS:  It is recommended that the application for variances be denied on the basis that the application  <br />is premature. All site plan improvements are shown based on future conditions for street access, access to city  <br />water and sewer, adjacent residential lots and lot lines, and proposed subdivision grading, all of which does not  <br />exist today. The Northstar 2nd Addition Final Plat and Plans must be submitted, reviewed and approved by the City,  <br />the Plat must be recorded at Washington County. The subdivision improvements must also be constructed and  <br />accepted by the City. Until these conditions are met, the existing conditions represented in the Chavez variance  <br />applications are subject to change and may alter the Chazev application submittal requirements.  <br />  <br />  <br />1. At this time there is no public street access, and there is no public water and sanitary sewer access to this  <br />property. Access to public streets, public water and public sanitary sewer will not be available to this parcel  <br />until future phases of the Northstar subdivision are platted and recorded. Until such time the existing  <br />conditions are subject to change.  <br />2. The application materials remain incomplete.   <br />a. A Stormwater Management Plan must be submitted meeting VBWD permit requirements.,  <br />b. All drainage and utility easements must be fully shown and identified on the site plans, including  <br />drainage and utility easements along adjacent lots and over the proposed lot.  <br />3. The area of impervious surface for the home and driveway must be provided and if greater than 6,000 SF, a  <br />stormwater management plan meeting VBWD permit requirements must be submitted to verify proposed  <br />on‐site BMPs. The Site plan proposes two rain gardens to meet VBWD permit requirements. The designs are  <br />only conceptual as submitted and subject to change. There is limited room for the installation of these BMPs  <br />and no soil borings have been submitted to demonstrate conducive soil characteristics being present. The  <br />plan may be feasible as proposed but also may not be feasible, all dependent on final design parameters.   <br />4. Off‐site grading/construction easements. The proposed grading and culvert installation requires work to be  <br />completed  on  the  adjacent  property  to  the  north.  The  home  construction  as  proposed  will  require  <br />permanent and/or temporary off‐site drainage and utility easements.   <br />5. Additional drainage and utility easements are required to ensure all 100‐year storm event high‐water‐level  <br />(HWL) contours are fully contained within an existing or expanded drainage and utility easement over the  <br />adjacent lot to the north.  <br />6. The proposed lot grading shows a driveway culvert to facilitate positive drainage for the rear yards of the  <br />two adjacent lots (draining north to south under the driveway). The driveway culvert pipe size and material  <br />must be specified. The upstream 100‐year HWL must be determined and shown on the grading plans and  <br />the 100‐year HWL contour must be fully contained within a drainage and utility easement.  <br />7. A driveway emergency overflow elevation must be established and protected by easement.   <br />8. The existing drainage and utility easement over all of Outlot B must be maintained and not vacated.