City Council Meeting <br />March 21, 2023 Page 11 <br /> <br /> <br />Streets and Access: Access to Lots 1‐3, Block 2 will be provided from a private shared <br />commercial drive that extends north from Hudson Boulevard through the center of the site. The <br />private driveway is proposed at the approved Hudson Boulevard access location for the north <br />parcel. Due to Fire Code regulations, there are limitations on the size of future buildings accessed <br />from this private drive. A condition has been added limiting the total square feet of buildings on <br />Lots 1-3 Block 2 to not exceed 124,000 sq. feet unless a secondary access is approved by the City. <br />Lot 1, Block 1 is also proposing to connect driveways with the adjacent retail strip center. <br />Pedestrian access is proposed with a marked crosswalk across Hudson Boulevard. Sidewalk and <br />trails will be connected within the PUD and to the adjacent properties. <br /> <br />Subdivision requirements: The subdivision has been reviewed in conjunction with the PUD. <br />Deviations from the standards are allowed with the PUD. The proposed lots meet minimum lot <br />area and width requirements. A deviation is being request to allow lots to front on a private <br />driveway versus a required public street (103.00.140) The City Attorney needs to review the title <br />work and provide a plat opinion prior to review of the final plat. A condition is included. A <br />Developers Agreement will be required as part of future plat approval. The City Engineer has <br />reviewed for conformance with engineering standards. His memo is attached, and all items are to <br />be addressed as part of the final plat submittal. <br /> <br />Lighting 105.04.070: City code requires that light fixtures be downcast and shielded. Light <br />quantities shall exceed one footcandle meter reading as measured from the centerline of the street, <br />nor shall any light or combination of lights, which cast light on an adjacent property, exceed 0.4 <br />footcandles as measured from said property line. <br /> <br />The auto dealer is proposing downcast and shielded light fixtures that are wall mounted and on <br />poles. Pole heights are 8 feet and 25 feet on 2.5-foot base. (Not taller than the building). Foot <br />candles exceed .4 at the property lines along the private drive, between Lots 1-2, Block 2 and are <br />close to zero at the front line (thus meeting centerline foot candles). On the fast-food site, 18-foot- <br />tall poles on 2 foot base are proposed (same height as the building). Foot candles proposed are .6 <br />on the corner side lot line, 1.4 on the rear lot line and 2.6 on the side abutting the retail strip mall. <br />The footcandles meet the ordinance at the centerline of the street. Deviations are being requested <br />to exceed the footcandles as noted on the plans. <br /> <br />Comprehensive Sign Plan: A Comprehensive sign plan is proposed for this PUD (attached). A <br />deviation is being requested to consider the private driveway a street frontage for purposes of this <br />PUD. The applicant is proposing wall signs, ground signs, and directional and informational signs. <br />Sign permits are required and they must comply with the approved Comprehensive Sign Plan and <br />City Ordinances. The sign ordinance has illumination standards. This information has not been <br />provided. The Comprehensive Sign Plan shall be revised to show how this is met or language <br />added that it will meet sign illumination requirements upon permit submittal. <br /> <br />One wall sign and one ground sign per street frontage is allowed with exceptions. For buildings <br />with over 100 feet of frontage, up to 3 ancillary wall signs are allowed. The maximum allowed <br />wall sign is 1 sq. foot per length of building frontage. The maximum size of any wall sign is 100 <br />sq. feet. <br />