Laserfiche WebLink
STRING INVERTER <br />WITH SINGLE DC <br />INPUT <br />SUN SHADE <br />CORRUGATED <br />METAL ROOF PANEL <br />AC CONDUITDC CONDUIT <br />9'-3" MAX <br />WARNING:High touch current .Earth connection essentialbefore connecting supply.iFor more detailsplease see the user manual. <br />CAUTION:RISK OF BURNING. DO NOT TOUCH! <br />CAUTION:DO NOT REMOVE COVER UNTIL 5 MINUTESAFTER DISCONNECTING ALL SOURCES OFSUPPLY.DANGER:BEFORE OPENING THE DEVICE, DISCONNECTFROM GRID AND THE PV GENERATOR. THEDEVICE MAY ONLY BE OPENED BY SERVICEPERSONNEL.WARNING:HAZARDOUS VOLTAGE AND ENERGY INSIDE,DISCHARGE BY SERVICE PERSONNEL BEFOREOPENING THE DEVICE. ELECTRIC SHOCKHAZARD. THE DC CONDUCTORS OF THISPHOTOVOLTAIC SYSTEM ARE UNGROUNDEDAND MAY BE ENERGIZED. <br />CAUTION:RISK OF ELECTRIC SHOCK - BOTH AC AND DCVOLTAGE SOURCES ARE TERMINATED INSIDETHIS EQUIPMENT. EACH CIRCUIT MUST BEINDIVIDUALLY DISCONNECTED BEFORESERVICING AND WHEN THE PHOTOVOLTAICARRAY IS EXPOSED TO LIGHT, IT SUPPLIES ADC VOLTAGE TO THIS EQUIPMENT. <br />WARNING - POWER FED FROMMORE THAN ONE SOURCE <br />5min <br />VERTICAL SUPPORT <br />STRUCTURES AND SUNSHADE <br />WOOD GATE POST <br />FOOTING DESIGN <br />PER FENCE <br />SUPPLIER <br />20'-0" <br />WOOD GATE POST <br />4"X4" 6 GA. GALVANIZED <br />WIRE MESH WELDED TO <br />FRAME7'-8" MINCHAIN LOCK <br />1'-6" MIN <br />9' MAX <br />ABOVE <br />GRADE <br />MOTOR/DAMPERS <br />TRACKER ROTATION <br />LIMIT 120° <br />72 CELL SOLAR <br />MODULE <br />1'-6" MIN MOTOR/DAMPERS <br />9' MAX <br />72 CELL SOLAR <br />MODULE <br />TRACKER <br />PILE <br />9'-3" MAX <br />ABOVE <br />GRADE <br />8' <br />9'-4" <br />40'40' <br />ABOVE <br />GRADE <br />ABOVE <br />GRADE <br />GRADE <br />6'6' <br />2' <br />DITCH1:1EDGE OF GRAVELEDGE OF GRAVEL4:1 <br />1: <br />1 <br />6:1 <br />SLOPE TO <br />EXISTING <br />GROUND <br />MATCH <br />EXISTING <br />GROUND6" TOP COURSE - CLASS 5 <br />COMPACTED SUBGRADE <br />2% SLOPE (TYP), MIN 1%2% SLOPE (TYP), MIN 1% <br />LOADBREAK SWITCH <br />OPERATING HANDLE <br />RECLOSER CONTROL <br />CABINET <br />FEEDER BREAKERS <br />MAIN BREAKER <br />WOODEN POWER POLE <br />WOODEN POWER POLE <br />15KV GROUP <br />OPERATED <br />DISCONNECT <br />15KV RECLOSER <br />6'6' <br />8'-8" <br />3'-8" <br />CONDUIT <br />SUPPORT STRUT <br />ABOVE <br />GRADE <br />STRING INVERTER <br />WITH SINGLE DC <br />INPUT <br />6" BASE COURSE <br />4'-4" MAX HEIGHT <br />AT MIDDAY <br />CONCRETE PAD <br />40' <br />ABOVE <br />GRADE <br />PRODUCTION METER <br />CABINET <br />WOODEN POWER POLE <br />15KV METER <br />6' <br />10'-10" MAX <br />ABOVE <br />GRADE <br />CONCRETE PAD3' MIN <br />NCU ANTENNAWEATHER SENSOR <br />5'-3" ABOVE GRADE <br />7' <br />7'-3" <br />UTILITY METER <br />OUTPUT <br />PROJECT <br />ADDRESS <br />DRAWING <br />TITLE: <br />SHEET NUMBER: <br />SCALE: <br />DRAWN BY: <br />CHECKED BY: <br />DATE: <br />REVISIONS: <br />WRITTEN DIMENSIONS ON THIS PLAN SHALL SUPERCEDE SCALED <br />DIMENSIONS. CONTRACTORS ARE RESPONSIBLE FOR FIELD <br />VERIFYING ALL DIMENSIONS. THIS DRAWING, DESIGN, CONCEPT <br />AND ARRANGEMENT REMAIN THE PROPERTY OF ONEENERGY <br />RENEWABLES AND SHALL NOT BE COPIED, DISCLOSED OR <br />REPRODUCED WITHOUT CONSENT. <br />DESCRIPTION <br />A B C D E F G H I J K <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />10 <br />11 <br />9 <br />CEF LAKE ELMO COMMUNITY SOLAR, LLC <br />ONEENERGY DEVELOPMENT <br />10755 50TH ST N <br />LAKE ELMO MN 55042 <br />ELEVATION DETAILS <br />1" = 4' <br />A-002 <br />OM <br />10/1/2021 <br />THIS PROJECT CONSISTS <br />OF THE DESIGN AND <br />INSTALLATION OF <br />1.000MWac SOLAR <br />PHOTOVOLTAIC SYSTEM. <br />MODULES ARE TO BE <br />MOUNTED IN SINGLE AXIS <br />TRACKERS, WHICH FOLLOW <br />THE SUN FROM EAST TO <br />WEST THROUGHOUT THE <br />DAY OR MOUNTED AT A <br />FIXED TILT FACING SOUTH. <br />INTERCONNECTION TO BE <br />COORDINATED WITH THE <br />LOCAL UTILITY.