My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
02-17-26 City Council Meeting Packet
LakeElmo
>
City Council
>
City Council Meeting Packets
>
2020's
>
2026
>
02-17-26 City Council Meeting Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2026 12:34:42 PM
Creation date
2/18/2026 12:31:18 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
200
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page: 3 <br /> <br /> <br /> <br />or the degree of restoration and repair of rutting following each maintenance event, or the degree <br />of vegetation maintenance throughout the BMP site and access road. In the event of homeowner <br />conflict, having full legal right to the property provides for easier enforcement, in the event the <br />homeowner encroaches the BMP or maintenance access road through grading changes, <br />playgrounds, fences, landscaping, and/or accessory structures. <br /> Should the City approve the placement of BMPs on private lots, it is strongly recommended <br />that staff be directed to research and prepare alternative engineering design standards and <br />easement encroachment agreements to address private lot BMPs. Any approval should also <br />clearly indicate that such approval is for Rural Estate Residential Subdivisions only. <br />3. Minimum floor elevations must be at least 2 feet higher than the adjacent 100‐year HWL <br />elevation. In addition, all low opening elevations for all buildings must be at least 1‐ft higher than <br />any adjacent emergency overflow elevation (EOF). Revisions and additional information are <br />required. <br /> The Pond 1 HWL must be a minimum of 2‐ft below the adjacent City owned water booster <br />station (Elevation 1009.91) or 1007.91. The pond must be lowered over 3‐feet which may or <br />may not be feasible in the current location. Stormwater ponding is not advisable in the vicinity <br />of the storm water booster station and should be moved much further away from the facility. <br /> The L1B1 existing building low floor and low opening elevation must be provided on the <br />Sketch Plan for determination of the allowable HWL for Pond 2 and Wetland 5. <br /> The low floor and low opening elevations for the existing Torre Pines home located southeast <br />of Pond 3 is required to establish the maximum HWL elevation for Pond 3. In addition, the <br />applicant is encouraged to meet with the VBWD to assess feasibility of constructing Pond 3 in <br />the proposed location, and review HWL requirements, outfall requirements, and potential <br />mitigation requirements for the protection of the downstream property. <br /> The low floor and low opening elevations for the existing Lake Elmo Heights home located <br />north of Pond 5 is required to establish the maximum HWL elevation for Pond 5. In addition, <br />the applicant is encouraged to meet with the VBWD to assess feasibility of constructing Pond <br />5 in the proposed location, and review HWL requirements, outfall requirements, and potential <br />mitigation requirements for the protection of the downstream property. <br /> The low floor and low opening elevations for the existing Lake Elmo Heights homes located <br />north of Filtration Basins 1E and 2W is required to establish the maximum HWL elevation for <br />BMPs. In addition, the applicant is encouraged to meet with the VBWD to assess feasibility of <br />constructing these BMPs in the proposed locations, and review HWL requirements, outfall <br />requirements, and potential mitigation requirements for the protection of the downstream <br />properties. <br /> The wetland HWL elevations (Wetlands 1‐5) must be determined and shown on any <br />preliminary plat application for the plat application to be deemed complete. All on‐site and <br />off‐site adjacent structure low floor elevations must be a minimum of 2‐ft. above the wetland <br />HWL elevations. <br />4. All pond outfall pipes must discharge in locations that do not create pointed discharges to <br />downstream properties. Off‐site easements may be required. <br />5. All wetland and stormwater basin emergency overflow elevations must be determined and shown <br />on any preliminary plat application for the plat application to be deemed complete. All adjacent <br />on‐site and off‐site structure low floor elevations must be a minimum of 1‐ft. above any adjacent <br />emergency overflow elevations. <br />6. All wetlands and wetland buffers must be protected by easement. It is standard Lake Elmo <br />practice to require wetlands and wetland buffers within Outlots dedicated to the City, however, <br />staff remains amenable to allowing them to remain on private lots protected by easements <br />dedicated to the City for Rural Estate Residential Lots. Wetland, wetland buffers and wetland HWL
The URL can be used to link to this page
Your browser does not support the video tag.