Laserfiche WebLink
ilk bURGOYNE VARIANCESs <br />in addition to the Engineer's-r.erommadations the Council <br />required yearly inspection of the system,•by the home owner,• <br />to insure the system is operating properly, <br />The Council discussed metering the water use and the use of <br />the vacant lot, next to Burgoyne, as a future drainfield site. <br />M/S/P Mottaz/Morgan adopting P,-81-69 granting a var.inace from build <br />& property line setbacks, but not from the 10' waterline setback, <br />because that is a Minnesota Health Department regulation, <br />subject to the following conditions: <br />1, on page 3 of the percolation report - the distance between <br />the bed and the water line should be 1.01, The bed dimensions <br />should be 20' x 32.51. The spacing between the distribution <br />pipes should be 5'--0". The water line in a north -south direction <br />should be eliminated. The street right -of. -way line should be <br />shown on the east edge of the bed, <br />2. On page 5 of the percolation repor.t,- revise the spacing to <br />5'-0" between distribution pipes, <br />3. On page 6 of the percolation report the drawing shows the <br />bottom of the bed 18 inches below the ground surface and <br />ground mounded up 6 inches, This may interfere with surface <br />water drainage away from the house. It is recommended that <br />the bottom of the bed be placed 24 inches below the ground <br />surface and no mounding occur. <br />4. The distribution box be fitted with a baffle to evenly <br />distribute the effluent, <br />5. The existing septic tank is proposed to be reused, if this <br />is done, the cover should be removed, entirely cleaned out, and <br />inspected for water tightness before reuse. <br />6, The northerly side yard should be sodded after construction <br />because of its steep slope. <br />7. The applicant should be made aware that this system just <br />meets minimum standards. The occupants of the house should be <br />encouraged to practice water conservation as much as practical. <br />8. A yearly inspection of the system be made by the homeowner <br />with the results forwared to the City. Inspection entails <br />opening the distribution box to verify that there are no solids <br />present and opening the septic tank and measuring the depth of the <br />sludge and water level in the tank, <br />Mr. Burgoyne will have to identify the corner boundaries of the <br />property before beginning construction. <br />The Engineer's letter will serve as a basis for inspection of <br />the system during construction. <br />