Loading...
HomeMy WebLinkAbout#15 Arts Center repairs MAYOR & COUNCIL COMMUNICATION -- page 1 -- DATE: 12/1/15 REGULAR ITEM # 15 AGENDA ITEM: Arts Center Repairs SUBMITTED BY: Clark Schroeder, Interim City Administrator THROUGH: Clark Schroeder, Interim City Administrator REVIEWED BY: Clark Schroeder, Interim City Administrator SUGGESTED ORDER OF BUSINESS: - Introduction of Item .............................................................. City Administrator - Report/Presentation…………………………………………City Administrator - Questions from Council to Staff ............................................. Mayor Facilitates - Call for Motion ............................................................... Mayor & City Council - Discussion ....................................................................... Mayor & City Council - Action on Motion .................................................................... Mayor Facilitates POLICY RECOMMENDER: Interim City Administrator FISCAL IMPACT: $25,000 to $35,000 SUMMARY AND ACTION REQUESTED: The building was inspected by our Building Official, Fire Chief, Parks Chairperson, and Electrical inspector. Their report is attached to this packet. I will highlight that if this building is going to be used as a public facility we should develop a budget to fix it up and bring it into compliance. In talking to Rick Chase Building Official, he said there are a number of different considerations to consider when considering uses for this building. According to the City Engineer, the building is not planned for a service stub for sewer connection. A visual inspection of the electrical system highlights repairs would be necessary to bring up to current code. Furnace should be inspected/maintained before winter. Structural supports and repairs to the foundation should be done. The attachment lists a number of different areas which need to be addressed if the public is going to utilize this building. His guess without looking into it is that it would take $25k to $35k to bring the building into compliance. The city could direct staff to obtain firmer estimates on repairs in order to help guide their decision. If the city council wishes City Council Meeting [Regular Agenda Item 15] December 1, 2015 -- page 2 -- to create and maintain a community center repairs/maintenance/budget/contractors need to be developed to create a safe compliant space. RECOMMENDATION: Direct staff to obtain firm estimates on repairs for the Arts Building, and hire out maintenance of the building. To: Clark Schroeder Scope: Building evaluation Address: 3585 Laverne Ave N (Arts Building) Date: September, 2015 City Staff was tasked with evaluating the Lake Elmo Arts Building, the comment below only relate to visual observations made on site. The following comments are provided as a result of site visits by the Electrical Inspector, Fire Chief, Building Official and the Parks Chairman Shane Weis. Well The facility is currently served by City water, it is staff recommendation to verify the prior well system for this site be evaluated to ensure the well was sealed in accordance with the Minnesota well code. According to the Minnesota Department of health there is no well sealing record on file, although there is a well disclosure certificate on file. See the attached well disclosure certificate. Septic The structure is currently served by an existing septic system, it is recommended by staff the current septic system be evaluated by a qualified technician in order to determine compliance with Department of Health regulations in accordance with the intended use. Please note according to Engineering the current downtown project does not include a service stub to this property. Electrical A visual observation was completed by the Contract Electrical inspector of the dwelling area. The following corrections/comments are: 1. Install the weather proof box by the rear entrance of the structure. 2. Repair/replace per code the exposed wire connection in the basement by the water softener. 3. Lighting in hallways upstairs correct per code. 4. Exposed wiring in detached garage. Due to some of the existing wiring methods and code requirements it is also recommended all future electrical work be done under the required permits. Dwelling plumbing recommendations: 1. Water leak- Kitchen sink. 2. Exterior garden hoses- Disconnect prior to winter. Dwelling mechanical recommendations: 1. Furnace- replace dirty filter. 2. Have start up test/cleaning completed on furnace. Foundation/structural: 1. CMU cracking- Visual observation of CMU cracking, a report from a design professional with special knowledge should be completed to determine the suitable nature of the foundation. 2. Main floor area- over addition (crawl space) has noticeable settling/shifting of main floor a design professional with special knowledge can determine suitability of this area. 3. Exposed sump- pit located in old well room, the discharge pipe of this system requires repair, and also the discharge location on the exterior should be located to discharge away from the foundation on the exterior. 4. There is noticeable dampness in the basement area. 5. Structural column- Basement observed a high percentage of decay. Required to replace. 6. Floor joist- Notching of floor joist in basement required to be repaired. Dwelling exterior recommendations: 1. Roof gutters- Area in gutters growing vegetation. 2. Siding- areas of decay. 3. Window frames- areas of decay. 4. Fireplace- If proposed to be in use a cleaning, and applicable codes standards should be applied. (spark arrestor) Dwelling interior: 1. Mold- visual areas observed. 2. Stairways- Guards and handrails not available in some areas. 3. Smoke detection- Not operational 4. Windows- The majority of windows are painted shut, to assist in emergency egress these are required to be operational. 5. Storage- Material stored in front of windows 2nd floor. 6. Storage- Items stored in stair landing to basement. 7. Lead based paint- May be present in some areas. *The attic area is not included in this evaluation due to access.* Access to one room upstairs not available. Existing fire alarm system & exit illumination/signage. 1. Verify system is operational as installed with qualified installer. It appears the last test date was completed in 2010. 2. Emergency lighting and exit signage not operational. (3each). Detached garage: 1. Overhead garage door- not operational. 2. Penetrations- Exterior wall penetrations seal. 3. Exterior walls- Areas of decay on corners, wall, and fascia. At the time of this evaluation access to the interior of the garage was not available. 4. Bottom cord of truss damaged and deflecting. Landscape: 1. Overgrowth of vegetation in some areas are negatively impacting the durability on the exterior of the structure. Deck 1. Visual observation of decking and guard from top side appear to be in serviceable condition. The structural components underside were not accessible for inspection. 2. There is noticeable areas of deflection of the joist system from top side.