Loading...
HomeMy WebLinkAboutResolution 2001-015City of Lake Elmo Washington County, Minnesota Resolution 2001 -15 A Resolution Requesting the Lower St. Croix Watershed District (fka): Valley Branch Watershed District) Consider Adoption of Rules and Regulations for the Control of the Rate and Volume of Water Leaving a Development Site WHEREAS, volume control is important because it addresses water runoff, flooding issues, prevents damage to infrastructure, and has the potential to save significant resources; and WHEREAS, millions of dollars have been spent on "after the fact" remedial projects in caused by uncontrolled development in the Lower St. Croix Watershed District; and WHEREAS, communities with a desire for high - density development have that right. They do not have the right to disregard the negative impact of such development on communities downstream; and the LSCVWS is best equipped and has the statutory authority to deal with those cross jurisdictional boundary issues; and WHEREAS, there are viable alternatives to allowing water to leave a development site at a rate and volume that exceeds what it was prior to development; and VI­1EREAS, in the interest of protecting the health, safety and welfare of its residents and residents downstream from its corporate limits, the City of Lake Elmo has adopted the "One Percent Rule "; and NOW, THEREFORE, BE IT RESOLVED that the Lake Elmo City Council hereby petitions the Lower St. Croix Watershed District to amend its rules to consider volume control such as the following "One Percent" requirement: The rate and volume of surface volume runoff within the boundaries of a proposed property subdivision shall not, in any event, be greater than the rate and volume of runoff existing on the proposed property division prior to the proposed development. To the extent possible, provisions shall be made for controlling runoff by construction or enhancement of ponding facilities (and other stormwater management techniques) on the site of land within the boundaries of the proposed property division, which ponding facilities should provide for both permanent and temporary storage and runoff waters. The increased runoff volume from development shall be calculated at 0.35 -acre feet for each acre of impervious surface proposed in the development. Impervious surface shall be all streets, parking lots, roofs, walks, driveways or other hard surface materials proposed in any development. For residential developments, each lot shall be assumed to contain 3,000 square feet of impervious surface for the house, garage and driveway. Existing ponds or other facilities may be used for runoff volume control. Any storage ponds shall be designed to retain the volume of runoff calculated under this provision below its outlet or overflow point and above the water table. The Soil Conservation Service method of analysis shall be used to calculate the runoff rate prior to development. The pre - development land use shall be considered permanent meadow with a soil conservation curve number of 58. The 100 year, 24 hour storm of 5.9 inches of precipitation shall serve as the basis of any such analysis. Adopted by the Lake Elmo City Council this 6th day of March 2001. Lee Hunt, Mayor Attest: Mary Kueffner, CiYy Administrator