HomeMy WebLinkAboutPZ Packet; 04-10-17
3800 Laverne Avenue North
Lake Elmo, MN 55042
(651) 747-3900
www.lakeelmo.org
NOTICE OF MEETING
The City of Lake Elmo
Planning Commission will conduct a meeting on
Monday April 10, 2017 at 7:00 p.m.
AGENDA
1. Pledge of Allegiance
2. Approve Agenda
3. Approve Minutes
a. March 27, 2017
4. Public Hearings
a. EASEMENT VACATION. A request by Bremer Bank, National Association,
8555 Eagle Point Blvd N, Lake Elmo, to vacate two easements from
PID#3302921410053: an existing drainage and utility easement to be relocated to
allow for expansion of existing building on site and an existing drainage and
utility easement to be relocated upon combination of PID #3302921410053 with
PID#s 3302921410050 and 3302921410051.
b. ZONING TEXT AMENDMENT. A request by the City of Lake Elmo for a
Zoning Text Amendment amending Article XIII: Village Mixed Use District of
the City’s Zoning Code, adding a Village Low Density Residential Zoning
District and making minor adjustments to the City’s VMX Zoning District
Standards.
5. Business Items
a. ZONING TEXT AMENDMENT –The Planning Commission will discuss a
proposed solar energy system ordinance.
b. ENGINEERING AND LANDSCAPE STANDARDS – The Planning
Commission will discuss and make recommendation on proposed City
Engineering and Landscape Standards.
6. Updates
a. City Council Updates – April 4, 2017
i. Inwood 5th Addition Final Plat and PUD Plans - Approved
ii. Approve Comp Plan Amendment to City’s Wastewater facilities -
Approved
b. Staff Updates
i. Upcoming Meetings:
April 10, 2017
April 24, 2017
ii. MAC CEP Report-none
c. Commission Concerns
7. Adjourn
***Note: Every effort will be made to accommodate person or persons that need special considerations to attend this
meeting due to a health condition or disability. Please contact the Lake Elmo City Clerk if you are in need of special
accommodations.
Lake Elmo Planning Commission Minutes; 3-27-17
City of Lake Elmo
Planning Commission Meeting
Minutes of March 27, 2017
Chairman Kreimer called to order the meeting of the Lake Elmo Planning Commission at
7:00 p.m.
COMMISSIONERS PRESENT: Larson, Dorschner, Emerson, Williams, Lundquist and
Hartley
COMMISSIONERS ABSENT: Fields, Kreimer and Dodson
STAFF PRESENT: Planning Director Wensman and City Administrator Handt
Approve Agenda:
M/S/P: Dodson/Williams, move to approve the agenda as presented, Vote: 6-0, motion
carried, unanimously.
Approve Minutes: March 13, 2017
M/S/P: Lundquist/Dorschner, move to approve the March 13, 2017 minutes as
amended, Vote: 6-0, motion carried unanimously.
Public Hearing – Zoning Map Amendment – General Business to Village Mixed Use
Wensman started his presentation regarding the rezoning of properties from GB to
VMX. Since 2013, there have only been 3 properties rezoned to VMX based on
applications received by the City. In 2016, the Planning Commission discussed rezoning
all of the properties to VMX, but tabled it for the following reasons 1) densities within
this area are guided too high 2) VMX standards are less restrictive 3) form based code
should be created 4) updated population and development projections for area needed.
The rational for the rezoning is to bring the subject perperties’ land use consistent with
the Comprehensive Plan. Without the rezoning at this tiem, many improvements to
these properties would require owners to rezone to VMX and obtain variances.
Wensman went through the differences between GB and VMX such as lot width, lot
area and impervious surface maximum. There are 83 parcels currently zoned general
business. There are some parcels that are guided RS that are guided for VMX and there
are a number of parcels zoned RS being used for business, not single family homes. The
residential properties being used for business were not noticed, but should be included
in this rezoning. Re-publication of the public hearing to include these properties would
2
Lake Elmo Planning Commission Minutes; 3-27-17
be needed. The properties that are guided for VMX, but currently used as single family
residences, staff is not recommending rezoning at this time. Staff feels that single
family residences should be an allowed use in the VMX. If that is the case, those
existing single family homes could be rezoned to VMX as it would have no impact on
them. New and existing homes should be treated the same.
Hartley is wondering why there is long list of condition uses as part of the VMX district.
Wensman stated it is the choice of the City Council to decide what is permitted and
conditional. Some uses are conditional to allow greater scrutiny of those uses. In the
Village, the lots and structures are very close to each other, so there could be uses that
should have greater scrutiny with conditions put in place to mitigate unforeseen
situations. Hartley thinks the veterinary services should be more specific to small
animals, not large animal services.
Wensman stated that if there are specific changes to the code, that code be discussed
through the public hearing for the zoning. Williams is wondering if the City Council
responded to the June Planning Commission request for updated population projections
for the Village area. Wensman stated that they did not specifically respond. They have
now launched into the Comprehensive Plan process and it will be addressed through the
process. Williams is asking if there were 2 houses fairly far apart on existing lots, could
they then subdivide and build another house. Wensman thinks there are greater
requirements for single family homes, but he will look at it. Williams asked about the
status of the form based code. Wensman stated that with the Comprehensive Plan
update, the priority for form based code was lowered. Emerson asked how many single
family homes would be affected if they change them to VMX. Wensman thought maybe
around 30 properties. Williams asked what the downside would be of those properties
being legal non-conforming. Wensman stated if the home burned down, they could
only rebuild on the footprint and would not be able to expand without a variance.
Williams is wondering about making single family homes conditional uses. Wensman
stated that might be a good solution.
Public Hearing opened at 7:32 pm
Sue Dunn, 11018 Upper 33rd Street, she would like the Commission to really think about
what things should be conditional uses. She is concerned about surface water and
impervious surface. She thinks the VMX could possibly add an additional 10,000 people
in the Village Area. She is concerned about the existing businesses. She thinks single
family homes are important to the Village Area. She thinks it is important to know what
the projections are for 2040 and how close we are to meeting those projections.
There is also a huge section to the East that is considered part of the Village area.
There were no written comments
3
Lake Elmo Planning Commission Minutes; 3-27-17
M/S/P: Dorschner/Williams, move to continue the public hearing for the Zoning Map
Amendment Discussion to rezone properties to VMX – Village Mixed Use to the next
possible meeting in order to properly notice the public hearing to include the additional
properties in the Zoning Map Amendment, Vote: 6-0, motion carried unanimously.
Public Hearing – Comprehensive Plan Amendment to add 2 properties to RSF Sewered
Wensman started his presentation regarding adding 2 properties to the Olson Lake Trail
sewer area and re-guiding them to Rural Single Family sewered. This would add 4497 &
4473 Olson Lake Trail to the MUSA. The feedback from the Met Council is that it would
just be an administrative review and would be similar to what was done in the Village to
add additional properties. This does not require any jurisdictional review as we have a
joint powers agreement with Oakdale. We have not received any comments from the
public notice sent out and advertised.
Dorschner asked what the Oakdale capacity would be for hooking up the rest of the
properties around Olson Lake on that road. Wensman stated that they are not in the
MUSA so there has been no talk about Oakdale picking them up. Wensman stated that
they do not know, because there is no plan for it and the property owners are not
requesting it. Handt stated that the Engineers did reach out to neighboring properties
to see if they wanted to be included, and these were the only 2 properties interested in
being included.
Williams is wondering if there is a Zoning Text that is actually rural single family
sewered. Wensman stated that the City does not have that specific zoning, but it is
probably something that could be created. Wensman stated that there really is no
problem leaving them as Rural Single Family zoning, but the change to the land use
designation was something the City Council was interested in to distinguish those
properties within the MUSA. Met Council was only concerned with land use designation
in the Comprehensive Plan allowing for sewer connection.
Emerson is wondering if they would move the MUSA line without the property owners
asking for it. Wensman stated that the City has not required properties to be sewered
unless the property owner has petitioned for it and signed a waiver.
Public Hearing opened at 7:44 pm
No one spoke and there were no written comments
Public Hearing closed at 7:45 pm
M/S/P: Dorschner/Lundquist, move to recommend approval of the amendment to the
City’s Wastewater Facilities Plan by adding PID #’s 090292132001 & 080292140059 to
the Olson Lake Trail MUSA, Vote: 6-0, motion carried unanimously.
4
Lake Elmo Planning Commission Minutes; 3-27-17
Hartley stated that they are adding these properties because they specifically requested
it. Looking at the map, there are potentially 4-5 properties that would seem to fit the
same characteristics of the other properties and why they requested it. Why is the City
not adding those properties? Williams stated it is because they did not request it and
according to Handt, they actively declined by not responding. Wensman stated that
there was one additional parcel that was thinking about it, but after further discussion
with the Engineer, they declined. Dorschner is wondering if we have the means through
the MUSA to require connection. Wensman stated that with the joint powers with
Oakdale, we have the means to connect these properties. Dorschner is concerned that
properties along the lake are still on old septic systems and what that means for the
future. Hartley stated that he is concerned because the City does not have a very good
mechanism to catch when drainfield fail and so we end up with even one house
affecting the Lake. Handt stated that most septic problems are caught when the
properties are sold or a building permit is issued. Williams stated that the same logic for
the additional properties could be applied to the whole Tri-Lakes area. If the MUSA was
opened up to the whole Tri-Lakes area, there would be numerous people speaking
against it. Wensman stated that there are a number of 201 septic systems in this area
that have been created to deal with some of the failing septic systems.
M/S/P: Lundquist/Dorschner, move to recommend approval of a Comprehensive Plan
Amendment re-guiding PID #’s 090292132001 & 080292140059 to Rural Single Family
Sewered on the City’s Land Use Plan, Vote: 6-0, motion carried unanimously.
Dorschner wanted to confirm that there was no Rural Single Family Sewered zoning.
Handt stated that there was not, but this is just guiding it as such in the Comprehensive
Plan. Hartley wanted to reinforce his concern from the standpoint of the
Comprehensive Plan, they do not have the potential pollution issues under control for
all of these properties that have individual septic systems and the inspection of them
comes well after the fact that they have failed. Williams doesn’t disagree, but doesn’t
feel that it will change anytime soon as he has heard the same discussion for 40 years.
Business Item –Preliminary Plat and PUD Plans - Royal Golf
Wensman started his presentation by stating that the Planning Commission approved
the rezoning to GCC on 3/13/17 and tabled the approval for the Preliminary Plan and
Preliminary PUD Plans. At the last meeting, the developer was proposing some changes
to the NW neighborhood. They have withdrawn those changes at this time. The
Planning Commission requested addition information on forest management, but the
developer is no longer interested in doing that. The developer has indicated he will
comply with the tree replacement requirements, but there is still dispute as to whether
the project is a mixed use. Since 3/13, the VBWD has raised concerns regarding some of
the infiltration basins. The developer is working through those issues and is confident
5
Lake Elmo Planning Commission Minutes; 3-27-17
there are adequate solutions that will not impact the plat. Staff has slightly modified
the condition pertaining to VBWD approval. Staff added a missing condition that the
green corridor in the NW neighborhood be a minimum of 100’ wide outside of the lot
area. Right now there is one area that is shown at 84’ with one of the lot lines.
Staff is recommending the same conditions with some corrections and additions. A
correction to #15, correcting the Lots and Block it pertained to. Condition #20 pertains
to the woodland management. It doesn’t hurt to keep that condition if the developer
changes his mind, but it is up to the Planning Commission how to handle that. Condition
#24 was reworded to make it clearer. #35 was added to capture the 100’ green
corridor. #36, #37 & #38 are the 3 conditions added by the Planning Commission
regarding the sidewalk along the South side of 20 th street and that there would be no
street lights except at street intersections to meet the dark sky ordinance and to work
with adjacent property owners to come up with screening that gets incorporated into
the landscape plans. The recommended findings are the same with the addition of #9
that a significant amount of public testimony regarding that 20 th street is already
dangerous without the additional traffic and the developer needs to explore ways to
make the road safer. Staff is recommending approval with 38 conditions of approval
and the 9 findings identified.
Dorschner asked what the dispute is around mixed use. Wensman stated that the tree
preservation plan has a provision that requires mitigation as well as landscape
requirements for residential development. For commercial and mixed use
developments there is an exception that all trees with the exception of ornamental
trees may be counted towards tree replacement requirements. The developer is saying
that this site is mixed use with the golf course being the commercial piece. They are
arguing that it the case so that all of the replacement trees will count towards their
landscaping requirements. Staff is saying that the golf course is the principle use; open
space. It was a public facility in the past and it had an accessory commercial use, which
is not the primary use. They will be creating a separate parcel for the more commercial
site, and possibly that could be exempted, but exempting the whole golf course is not
consistent with past practice and the City attorney does not support the mixed use
interpretation. Wensman stated the difference would be a large cost to the developer
in tree replacement or a significant loss of trees for the City. Staffs solution for this was
the idea of forest management to better serve the development. The developer likes
the tree preservation better because it is more quantifiable vs the forest management
which is kind of a gray area.
Rick Packer, Royal Golf, stated that the attorneys were discussing the mixed use concept
and they had hoped that they could come to a compromise. They did not feel that the
forest management was a compromise, but an exchange for the tree preservation
requirement. The Royal Golf attorney opinion is that this development is mixed use.
There is economic incentive that the City has provided to commercial development.
There is currently no definition of mixed use in the City code. In the absence of a
6
Lake Elmo Planning Commission Minutes; 3-27-17
definition, those terms are supposed to be given their plan and ordinary meaning. The
Royal Golf Community has 4 different types of uses on the property. There is
residential, business services, food service and outdoor recreation. They feel that the
golf course is clearly a commercial use. This is a wooded site vs a cornfield, so the
number is really large. There are 8500 trees on this site, with about 3000 trees being
removed. They are allowed to remove roughly 2500 trees or 30%. They are removing
about 35% or 418 trees more than what is allowed. Based on the City code without the
mixed use exemption, they would need to plant 3024 trees or 10 trees per lot. Packer
states it would cost them $1.5 million dollars for trees alone. They had proposed 900
trees or 3 trees per lot. Packer stated that staff rejected that as there was no way for
them to inspect them. They are planting 214 trees that are ornamental which do not
count either. They feel that they legally qualify for a mixed use and should get the
exemption. They were looking for some compromise that they did not get.
Royal Golf is proposing to construct an off street trail in a location shown on the
overhead vs a trail on 20th Street that has no shoulders. There is a significant grade
change where the trail would need to go and a loss of trees. They would argue that it
would be better served with adding a shoulder to the road that is wide enough to walk
and bike on. Packer talked about the alternate Villa design and would like that to move
forward to the City Council. There is one driveway that is in the sanitary sewer
easement which is a concern to the city engineer. They can enter something into
documents recorded against the property. Packer stated that this plan has one less unit
than proposed with plat, but is essentially the same grading plan.
Lundquist asked why the proposed sidewalk on 20th only goes just past the clubhouse.
Packer stated that there are places that are very steep and would be very disruptive to
that area. Williams asked why the City would not accept the widened shoulder or
sidewalk within the ROW. Wensman stated that MSA standards would require the
sidewalk to be located on the outer edge of the ROW.
Larson asked what the status of the tree replacement is. Wensman stated that there is
the landscape requirement and the street tree requirement. The City is going the mor e
lenient interpretation, requiring landscaping based on the disturbed area calculation.
Street trees will go in with the road when the improvement goes in. In terms of the
development trees with 4 trees going in with the home, as long as the City has escrow
to ensure the trees go in, the timing isn’t as important. There is a difference between
the developer and the City of approximately 1000 trees. That difference hinges on the
Mixed Use issue as the City and developer have failed to come to a compromise.
Williams asked if they are opposed to any forest management in exchange for relief of
the tree replacement. Packer stated that there is no compromise if it is dollar for dollar
exchange they would not be interested. Williams stated that he is willing to relax the
tree replacement provisions from 1000 to 500 in return for a program of buckthorn
removal for 3 years after construction has started. Hartley thinks that it is problematic
as it is not just the individual home owners. Dorschner stated that buckthorn is very
7
Lake Elmo Planning Commission Minutes; 3-27-17
difficult to manage and is good screening. Hartley feels that the City is better off having
new trees vs a management plan based on the possible tree diseases. Emerson feels
that the uses out there are mixed use and that is what they need to decide. Williams
feels that they need to go with the City Attorney’s opinion on that issue, but also feels
that there should be some relaxation of the number of trees with buckthorn removal.
M/S/P: Williams/Lundquist, move to add an additional condition that the tree
replacement requirement based on residential use be relaxed by 50% in return for the
developer controlling buckthorn by cutting stems and treating the remaining stumps by
either physical pulling or by herbicide application for a period of three years beyond the
date for which construction begins for the adjacent phase, Vote: 4-2, motion carried
with Hartley and Dorschner voting no.
Wensman stated that this motion would replace condition #20 in the packet. Dorschner
asked how many trees this would leave them to replace. Half would be around 500.
Dorschner feels there would be more value in trees vs. the forest management. He
feels the real issue is the mixed use interpretation vs. residential, but feels they need to
go with the attorney’s opinion. Jim Felton talked about what they did for the wildlife
corridor and what was required by the VBWD. His estimate of cost for what they have
done is about 50K.
Williams doesn’t believe there are any West Lakeland properties that they need to be
concerned about in regards to screening. Packer stated that they have an agreement
with the Homestead development. Williams feels that the City should allow the golf
carts on the streets for the GCC. Wensman stated that a separate ordinance would be
required that is not part of the zoning code. They could recommend that staff bring one
forward. Hartley stated that personally he is not in favor of the golf carts because they
are often driven irresponsibly and rules are not followed. Emerson doesn’t have a
problem with golf carts and maybe an age limit could be put on it. Dorschner was in
Arizona and many of the communities there have them. Larson stated that the golf
carts would have destinations such as the clubhouse, restaurant, etc. Schroeder stated
that they have looked at many ordinances in different cities and they address such
things as age, speed, hours of operation, lights, etc.
M/S/P: Williams/Dorschner, move to propose an additional finding #10 that the
Planning Commission determines that it would be desirable to allow golf carts on the
public streets within a golf course community, Vote: 5-1, motion carried, with Hartley
voting no.
Williams asked if the Fire Chief commented on the street names. Wensman stated that
the Fire Chief does not like the new street naming policy, and is going to be taking the
whole street naming policy back to the public safety committee. This street naming
complies with the current ordinance.
8
Lake Elmo Planning Commission Minutes; 3-27-17
In regards to the street lights, the City Engineer stated that there is no requirement to
have street lights in a development.
Packer is wondering if they have addressed the Villa area. Handt stated that as of
Friday, the developer was pulling that section, but tonight included it in the
presentation. Wensman stated that one clear problem based on their limited review is
the driveway with a storm pipe underneath it which will need to change.
M/S/P: Williams/Dorschner, move to recommend condition #39 that staff reviews and
approves the new plans presented tonight regarding the Villas and that the developer
complies with all of the staff recommendations, Vote: 6-0, motion carried unanimously.
M/S/P: Lundquist/Larson, move to recommend approval of the Preliminary Plat and
Preliminary Planned Unit Development Plans for the Royal Golf Club at Lake Elmo with
the 39 conditions based on the 10 findings identified in the staff report and amended by
the Planning Commission, Vote: 6-0, motion carried unanimously.
Business Item – Zoning Text Amendment – Village Low Density Residential Zoning
Wensman started his presentation regarding the Village Low Density Residential Zoning.
Since the last meeting, there were density ranges added, the impervious calculation was
added to 35%, struck the maximum setback standard, allows free standing multi-family
dwellings as a CUP to match the comprehensive plan, and clarified the setbacks for
other residential uses. There was a desire at the last meeting to have a build to line
incorporated into the VMX and the staff thinks that they have addressed that by the
prevailing setback of the street to have consistency. If it is a new street, it can be
decided at that time. Wensman went through some of the other standards.
Williams asked about the garage standards and why that need to be called out
specifically. Wensman thinks that it for existing homes that might want to build an
additional garage. There was some information regarding tiny houses and if the City
wants to alter its minimum home size. Wensman thinks more research needs to be
done regarding this for the next meeting. Another consideration is would we want to
have different standards for the urban vs rural areas. There was discussion if the
Planning Commission thinks the VMDR zoning should just use the standards for LDR and
have that reference made in the Comprehensive Plan.
Hartley is wondering how the City determines in the VMX what is a permitted use and
what requires a condition use permit. Wensman stated that there is not a straight
criteria that determines if it is permitted vs a CUP. Typically the City makes uses
conditional if it is perceived that the type of use could potentially create issues so the
city wants to put conditions on the use. Williams stated that if there were
9
Lake Elmo Planning Commission Minutes; 3-27-17
recommendations of uses that should be permitted, the Commission could take up that
discussion in the future.
Business Item – Zoning Text Amendment – Solar Ordinance
Wensman started his presentation regarding the solar ordinance. Some of the reasons
for a solar ordinance are to protect neighbors from glare, that it meets imperious
surface, area and size requirements and that there is a decommissioning plan. There is
also a solar farm definition, which is not currently outlined in the Zoning Code as
allowed permitted or condition primary use. Where should they be allowed as a
primary use if anywhere? Some of the standards are that it must comply with accessory
structure setback, height, lot coverage, etc. Should solar energy systems be exempt
from certain standards in certain areas? Hartley is wondering if the City wants to add to
the ordinance that an HOA can’t prohibit the use of solar panels. Wensman stated that
would be unusual, but the City could put that restriction on. Currently solar farms are
not allowed as the primary use anywhere, should they be? Staff is looking for any other
additional standards that the Commission would like to include.
Hartley thinks a large commercial installation is very different than a residential one. He
also feels that in residential, if it is limited to the rooftop, that is different issue than if it
takes up a whole back yard. Williams suggested a slightly different definition of solar
farm from “wholesale sales” to “offsite customers”. Williams wants “off -grid systems”
defined in the interconnection agreement section. Williams would like to eliminate
“using a reflector to enhance solar production” from the reflectors section. Hartley
stated that the commercial operations are probably the only ones to use reflectors.
Williams is also confused about “screening to the North side of the solar array”. He
thinks they need to look at that. Hartley suggested just striking the word north.
Williams thinks that it needs to be stated that solar panels are considered impervious
for calculations. Emerson doesn’t feel that the whole thing should be considered
impervious. Williams feels that especially in commercial operations, you have
compaction of the soils and it is no longer like a vacant field. There are also access roads
and maintenance to consider. Wensman stated that it is creating a concentrated flow
and runoff. Williams feels that it is easier for the City to manage and not inconsistent
with the codes of other Cities if it is considered impervious. Hartley stated that maybe
the total area could be calculated and 50% is considered impervious.
Williams would like to add a provision that HOA’s and CIC’s are not allowed to prohibit
solar systems. He is wondering if they should add solar systems as an incentive in the
PUD bonus table. Williams asked if these systems would require a city building permit.
Wensman stated that they would because of the footings. Hartley stated that screening
and such would need to be reviewed by the City. Wensman stated that it might not be a
building permit, but a zoning compliance review. Williams stated that there is a
reference to building code in the code requirements section and it should say all rooftop
10
Lake Elmo Planning Commission Minutes; 3-27-17
or building integrated systems. Williams would like to add the words “and/or screened”
to item #7 Visibility to be consistent with other rooftop structures. For storm water
management, Williams would like to add “Watershed Districts requirements”.
City Council Updates – March 21, 2017 Meeting
i) Wildflower 2nd Developer Agreement - passed
ii) Lakewood Crossing 2nd Addition Concept Plan PUD - passed
iii) Noise Ordinance – on hold
Staff Updates
1. Upcoming Meetings
a. April 10, 2017
b. April 24, 2017
2. MAC CEP Report
Commission Concerns
Hartley would like to reinforce the idea that the meetings not be too long and that the
Commission get out at a reasonable hour. If the meeting gets too long, they are not at
their best.
Dorchner wants to finalize the rural single family sewered. Wensman stated that the
ordinance states that the rural single family should be predominately individual septic,
but does not require it to be so. If they are designated in the comprehensive plan by the
MUSA, it is allowed. Dorschner feels there should be different standard for when you
are sewered and when you aren’t. Wensman will look at it more detail and report back.
Williams is concerned that there has been nothing done as a City regarding form based
code. He recognizes that it takes a long time, but it just keeps being pushed down the
road. Wensman stated that through the Comp Plan amendment process, the vision will
be reaffirmed.
Meeting adjourned at 10:45 pm
Respectfully submitted,
Joan Ziertman
Planning Program Assistant
BUSINESS ITEM 5b
STAFF REPORT
DATE: APRIL 10, 2017
AGENDA ITEM: 5B – PUBLIC HEARING
CASE #2016-59
TO: Planning Commission
FROM: Emily Becker, Planner
SUBMITTED BY: Zoning Text Amendment – Village Urban Districts
REVIEWED BY: Stephen Wensman, Planning Director
BACKGROUND:
The Planning Commission has reviewed a proposed draft Village Urban Low Density (V-LDR) zoning
district as well as minor amendments to the Village Mixed Use (VMX) District at its January 23, 2017,
February 13, February 27, 2017, and March 27, 2017 meetings.
ISSUE BEFORE THE COMMISSION:
Staff respectfully requests that the Planning Commission hold a public hearing and recommend changes
to and/or approval of the proposed draft ordinance of the Village Low Density Residential and minor
amendments to the Village Mixed Use (VMX) District.
PLANNING/ZONING ANALYSIS:
Summary of Discussed Changes since the last Planning Commission meeting to Proposed
Ordinance. The following provides changes and responses to Commission feedback provided from the
last meeting at which the subject ordinance was discussed:
Multi-Family Not within a Mixed Use Development Added. There was question about if there
was a definition for multi-family and for mixed use. Multi-family dwelling is defined in the
Zoning Code as a building containing three or more dwelling units. The mixed use definition
Mixed Use Definition. The Commission asked that mixed use be defined. Staff was unable to
find a very good example of mixed use to fit broadly within the Code. The VMX District states
that more than one use is allowed on one parcel of land or in one building. Mixed use could mean
a number of things: a mixture of uses in one building, one parcel, one development, one area, or
one neighborhood. Staff does not recommend that Mixed Use be defined, as it could cause issues
with interpretation elsewhere in the Code.
Additional Density Standards Added. Staff added language from the Comprehensive Plan
Amendment approved in late 2015 that allows a higher density for senior congregate care
facilities with services in the VMX to exceed listed density maximums with a range not to exceed
16 units per acre provided the facility can satisfy all zoning and applicable conditional use permit
reviews.
Garage Setback. There was question as to why garages should be required to be setback at least
25 feet. This is to prevent cars parked in driveways from parking in the right-of-way. Garage
setbacks were added to the Lot Dimension and Setback Requirements table in order to simply
standards.
Standards for Village Medium Density Residential. There is still no Village Medium Density
Residential Zoning District. The density that is set forth in the Comprehensive Plan for the
Village Medium Density Residential land use is 2.5-4.99 units per acre. This is virtually the same
density as Urban Low Density Residential (2.5-4 units per acre). Areas guided for Village
Medium Density Residential may be zoned Urban Low Density to achieve the density for which
2
BUSINESS ITEM 5b – ACTION ITEM
the area is guided. The reason for the creation of the Village Low Density Residential district is to
create an urban residential zoning district which allows a density of 1.5-2.49 (the density the
Comprehensive Plan designates for areas guided Village Low Density Residential), as there
currently exists no zoning district that allows this.
Additional Setback Standards for County Roads Added. Staff has received requests from the
county to add increased setback standards for county roads. Resultantly, Staff has recommended
adding setback standards from county roads CSAH 14 and 17 at a minimum of 30 feet.
Single Family Homes in VMX. The Commission has expressed that they would like to see
single family homes still allowed in the VMX District.
o Zoning Code Language Currently. Currently, standards for the VMX district indicate that
an existing single family home shall be considered a permitted, rather than non-
conforming use, in the VMX zoning district. This language was derived from the
Comprehensive Plan language outlined below. The Comprehensive Plan does not classify
single-family homes as an allowed use in the VMX zoning district.
“[Uses in] VMX: Twin Home, Townhouse, Apartment/Condominium, Housing
Above Retail”
“The existing residential neighborhoods within the Village Planning Area will
[be] guided either as RS – Rural Single Family or as VMX – Village Mixed-Use
with the intent of classifying all existing single family residential homes as
permitted uses:
o Language needs to be changed. This current language does not make legal sense. Either a
use should be permitted or conditional use. Upon rezoning, a use may be made a legal
non-conforming use, which would indicate that it could not be expanded. A legal non-
conforming use may not be expanded through the variance process, as that would be
considered a use variance, which is not allowed.
o Single Family Detached Home as a Conditional Use in VMX. The Commission had
mentioned that they may wish to see single family detached homes conditional uses in the
VMX district as an option. Staff has drafted the proposed ordinance to read this way.
However, the above should be considered regarding the Comprehensive Plan’s
designated uses for the VMX district.
Minimum Lot Size Requirements for Single Family Detached Home in VMX.
o Minimum Lot Size. Staff has estimated that the minimum lot size of single family homes
within the VMX District is approximately 0.3 acres (13,068 sf). The Commission had
expressed concern about lots with single family detached homes to subdivide. The
current ordinance designates a minimum lot size of 5,000 sf for a single family detached
home (even though it’s not an allowed new use). To address Commission concern, Staff
is proposing that the minimum lot size be 9,000 sf, mirroring the minimum lot size
standard of the proposed V-LDR standard. This would prevent a majority of the lots
within this district to further subdivide, as only approximately eight of the single family
residential lots guided for VMX would be able to further subdivide under this standard.
o Minimum Lot Width. The current minimum lot width for single family homes within the
VMX district is designated as 50 feet. However, it may make sense to increase this to 70
feet given the proposed increase minimum lot size of the district. It appears that very few
single family lots within the Village have a lot width of as little as 50 feet, however it
may affect some lots to increase the minimum to 70 feet. If the minimum lot size is
increased, it may make sense to change the minimum lot width as well. Staff has changed
the minimum lot width in the proposed ordinance but is looking for recommendation on
this.
Conditional and Permitted Uses Currently Allowed in the VMX District. The Commission
had expressed some concern over conditional and permitted uses currently designated as allowed
3
BUSINESS ITEM 5b – ACTION ITEM
within the VMX zoning district. The Commission should specifically outline which uses are of
concern and discuss. If additional standards are needed for specific uses, this should also be
discussed.
New Housing Types Mixture Requirement. The following statement was added to standards
for a single-family attached home in the VMX District. Staff added this standard, as it exists as
standards for multi-family dwellings and two-family dwellings in the urban residential district.
Staff has asked that the City Attorney review this language, as they believe it may not be legal to
limit the type of housing one person can put in on a block just because someone had previously
erected the same type of housing.
o “New housing types should be introduced in limited quantities to increase diversity and
housing choice, not to replace whole blocks of existing housing. Therefore, no more than
1/4 of the lineal frontage of a developed block may be redeveloped as two-family units,
and no further two-family or higher density development is permitted once this threshold
is reached. Lineal frontage shall be measured around the entire perimeter of the block.”
Veterinary Services. One comment from the Commission referenced that they may not wish to
see veterinary services for large animals in the downtown area. Staff has added language that sets
forth standards preventing this. The Commission should also keep in mind that further conditions
can be placed during the conditional use permit process to help mitigate risks associated with
certain uses.
House Size. The Commission did not specifically speak about the single family detached
dwelling size regulation that was added to the VMX and V-LDR Zoning Districts. This standard
remains unchanged as a result.
Question about General Site Design Considerations (154.504) vs. Development Standards
for Specific Uses (154.505). The Commission had a question about why these were two separate
sections. Section 154.504 sets forth general standards for all development within the Village
District, whereas Section 154.505 sets forth general standards for specific uses.
Findings.
The Planning Commission drafted the following findings at its February 13, 2017 meeting:
1. That certain areas of the Old Village are guided for Urban Low Density Residential in the Land
Use Plan of the Comprehensive Plan, which designates a density of 1.5-2.49 units per acre.
2. That there currently does not exist a Village Low Density Residential zoning district which has a
density of 1.5-2.49 units per acre within the Zoning Code.
3. That the Village Low Density Residential zoning district is being proposed due to the imminence
of the Gonyea West Development, which is expected to be proposed to be located within the Old
Village in an area guided for Village Low Density Residential.
4. That the Planning Commission would be interested in exploring increased densities within the
Old Village as an amendment to the Comprehensive Plan.
RECOMMENDATION:
Staff recommends that the Planning Commission hold a public hearing and provide feedback on or
recommend approval of amendments to Article XIII: Village Mixed Use Districts, which add standards
for the V-LDR Village Low Density Residential District and proposes minor changes to the VMX –
Village Mixed Use District. If the Commission wishes to make recommendation at this time, the
Commission may do so with the following motion:
“Move to recommend adoption of Ord 08- , creating a Village Low Density Residential District and
making minor amendments standards of the Village Mixed Use District.”
4
BUSINESS ITEM 5b – ACTION ITEM
ATTACHMENTS:
1. Draft Ordinance
Planning Commission Draft 4/10/2017
1
CITY OF LAKE ELMO
COUNTY OF WASHINGTON
STATE OF MINNESOTA
ORDINANCE NO. 08-__
AN ORDINANCE AMENDING ARTICLE XIII: VILLAGE MIXED USE DISTRICT AND
CREATING STANDARDS FOR A VILLAGE LOW DENSITY RESIDENTIAL ZONING
DISTRICT
SECTION 1. The City Council of the City of Lake Elmo hereby amends the Lake Elmo City Code
Title XV: Land Usage; Chapter154: Zoning Code; Article XIII: Village Mixed Use District; to read
the following:
ARTICLE XIII: VILLAGE MIXED USE DISTRICTS
§ 154.500 PURPOSE AND DISTRICT DESCRIPTION
(A) V-LDR Village Low Density Residential. The purpose of the V-LDR zoning district is to
provide opportunity for lower density residential development within the Old Village and create a
transition and connectivity between the heart of the Old Village and surrounding rural areas. Residential
development within areas zoned V-LDR will occur at a density of 1.5-2.49 units per acre.
(B) VMX – Village Mixed Use District. The purpose of the VMX district is to provide an area
for compact, mixed use development made mutually compatible through a combination of careful
planning and urban design and coordinated public and private investment. This district is intended to
continue the traditional mixed use development that has occurred in the Village area by allowing retail,
service, office, civic and public uses as well as residential units. The mixture of land uses within the
district is essential to establishing the level of vitality and intensity needed to support retail and service
uses. Development within areas zoned VMX will occur at a density of 6-10 units per acre. Senior
congregate care facilities may exceed this density maximum with a range not to exceed a total of 16
units per acre, provided the facility can satisfy all zoning and applicable conditional use permit review
criteria. The placement of building edges and treatment of building, parking, landscaping, and
pedestrian spaces is essential to creating the pedestrian friendly environment envisioned for the VMX
district. The standards in this chapter are intended to implement and effectuate the principles and
relationships established in the Village Master Plan, which will be carried out through specific standards
related to site planning, signage, architecture, building materials, and landscaping. Renovation and infill
of traditional storefront-type buildings is encouraged, and parking standards may be waived to
recognize the availability of on-street and shared parking facilities.
§ 154.501 PERMITTED AND CONDITIONAL USES
Planning Commission Draft 4/10/2017
2
Table 11-1 lists all permitted and conditional uses allowed in the urban residential districts. “P”
indicates a permitted use, “C” a conditional use. Uses not so indicated shall be considered prohibited.
Cross-references listed in the table under “Standards” indicate the location within this Ordinance of
specific development standards that apply to the listed use.
A. Combinations of uses, Village Districts. The following use types may be combined on a single parcel:
1. Principal and accessory uses may be combined on a single parcel.
2. A principal and secondary dwelling unit may be combined according to the standards of Section
155.137 154.454 (C).
B. Combination of uses, VMX District.
1. Single-family attached or multi-family complexes designed for rental or condominium occupancy,
since these typically include multiple units and buildings on a single parcel.
2. Other permitted or conditional uses allowed within the district may be combined on a single parcel,
provided that a unified and integrated site plan is approved. The entire development must be approved
as a conditional use.
3. A mixed-use building that combines permitted or conditionally permitted residential, service, retail and
civic uses may be developed meeting the form standards of this Article. Office or studio uses on upper
stories are encouraged.
Planning Commission Draft 4/10/2017
3
Table 11-1: Permitted and Conditional Uses, VMX Village Districts
V-LDR VMX Standard
Residential Uses Residential Uses
Household Living
Single-family detached dwelling P P* C* 155.504.A 154.505 (A) (1),
(2), *(4)
Two-family dwelling - P* 155.504.A 154.505 (A) (1),
(4)
Single-family attached dwelling - C 154.505 (A) (1), (5)
Multifamily dwelling - C 154.505 (A) (1), (6)
Secondary dwelling C C 154.505.D 154.454 (C) &
154.505 (A) (1), (3)_
Live-work unit - P 155.505.J 154.505 (B) (6)
Group Living
Group Home P P 155.102.C 154.301 (A)
Group Residential Facility - C 155.102.D 154.301 (B)
Congregate Housing - C 155.102.E 154.301 (C)
Semi-Transient Accommodations - C 155.102.F 154.301 (C)
Public and Civic Uses
Community Services - P 155.103.C
Day Care Center - P 155.103.D
Public Assembly - C 155.505.M
Religious Institutions - C 155.505.N 154.303 (N)
Schools, Public and Private - C 155.505.O 154.303 (A)
Services
Business Services - P
Business Center - P Offices - P Communications Services - P Education Services - P 154.303 (A) Financial Institution - P 155.505.P Funeral Home - C Lodging - C 155.505.Q 154.302 (D)
Medical Facility - C 155.505.R 154.303 (B)
Membership Organization - C 155.505.N
Nursing and Personal Care - C 155.104.C 154.303 (C)
Personal Services - P
Repair and Maintenance Shop - C 155.505.E 154.505 (B) (1)
Trade Shop - C 155.505.F 154.505 (B) (2)
Veterinary Services - C 154.505.G 154.505 (B) (3)
Planning Commission Draft 4/10/2017
4
Food Services
Standard Restaurant - P
Restaurant with Drive-through - C 154.304 (A)
Drinking and Entertainment - P 155.505.S 154.304 (B)
Sales of Merchandise
Retail Trade 1 - P 155.505.T
Farmer’s Market - C 155.505.AA
Garden Center - C 155.505.U 154.505 (B)
(4) Neighborhood Convenience Store - P 155.505.V
Shopping Center - C 155.505.W
Wayside Stand P P 154.454 (D)
Automotive/Vehicular Uses
Automobile Maintenance Service - C 155.505.X 154.505 (B)
(5) Automobile Parts/Supply - P 155.505.X154.505 (B)
(5) Gasoline Station - C 155.505.X 154.305 (B)
Parking Facility - C 155.505.X 154.505 (B)
(7) Sales and Storage Lots - C 155.505.X 154.305 (C)
Outdoor Recreation
Outdoor Recreation Facility - C 155.505.Y 154.306 (C)
Parks and Open Areas P P
Indoor Recreation/Entertainment
Indoor Athletic Facility - C 155.505.Z 154.307
Indoor Recreation - C 155.505.Z 154.307
Transportation and Communications
Broadcasting or Communications
Facility
- C 155.110.B
Mixed Uses
Combination of Principal Uses on a
single parcel
- C/P 154.501 (B)
Combination of Principal and
Accessory Uses on a single parcel
P P 154.501 (A)
Accessory Uses
Home Occupation P P 155.111.A,B
154.012 (12) (e)
Bed and Breakfast - C 155.111.C 154.310 (A)
Family Day Care P P 155.111.G 154.012 (12)
(d) Group Family Day Care - C 155.111.G Temporary Sales P P 155.107.B 154.509 (G)
Parking Facility - P 154.505 (H) (7)
Solar Equipment P P 155.111.I154.310 (C)
Swimming Pools, Hot Tubs, Etc. P P 155.111.J
Other Structures Typically
Incidental and Clearly Subordinate
to Permitted Uses
P P
Planning Commission Draft 4/10/2017
5
Note: Standards listed in Table 11-1 are listed by Article, Section and Subsection.
1Retail Trade in the VMX District includes all uses and activities defined as Retail Trade in §155.507.B.5
154.012 (5) (c) with the exception of building supplies sales and warehouse club sales.
§ 154.502 LOT DIMENSIONS AND BUILDING BULK REQUIREMENTS
Lot area and setback requirements shall be as specified in Table 11-2, Lot Dimension and Setback Requirements.
Table 11-2: Lot Dimension and Setback Requirements, VMX Villages Districts
V-LDR VMX
Minimum Lot Area (sq. ft.) a
Non-Residential Use - None
Single Family Detached Dwelling 9,000 5,000 9000
Two-Family Dwelling (per unit) b - 3,000
Single-Family Attached (per unit) c - 2,500
Multi-Family Dwelling (per unit) - 1,800
Secondary Dwelling - See 154.454 (C)
Live-Work Unit - 3,000
Congregate Housing - 155.102.E 154.301
(C)
Other Structures - 3,500
Maximum Lot Area (acres)
Residential Structures N/A N/A
Other Structures N/A 5
Minimum Lot Width (feet)
Single Family Detached Dwelling 70 50 70
Two-Family Dwelling (per unit) b - 30
Single-Family Attached (per unit)c - 25
Multi-Family Dwelling (per building) - 75
Live-Work Unit - 25
Maximum Height (feet/stories) 35 35/3 d
Maximum Impervious Coverage
Residential Structures 35% 75%
Other Structures - No Limit
Minimum Building Setbacks (feet) g
Planning Commission Draft 4/10/2017
6
Front Yard 25 Single-Family
Detached, Two-
Family, and Single-
Family Attached:
See LDR standards of
154.452
Multi-Family
Dwellings:
154.505 (A) (6) (b)
All Other
Residential Uses:
154.505 (A) (7)
Non-Residential
Uses:
154.505 (B) (1)
Interior Side Yard 10 10 e
Corner Side Yard 15 0 f
Rear Yard 20 10
Garages 25 25
Notes to VMX Village Districts Table
a. No development may exceed the residential density range as specified in the Comprehensive Plan for the
Village Mixed Use corresponding land use category.
b. Two-family units may be side-by-side with a party wall between them (“twin”) or located on separate
floors in a building on a single lot (“duplex”). The per-unit measurements in this table apply to “twin”
units, whether on a single lot or separate lots. The standards for single-family detached dwelling shall
apply to a “duplex” containing two vertically-separated units on a single lot.
c. In the case of single-family attached dwellings that are not situated on individual lots, minimum lot size
shall be applied to each unit as a measure of density; i.e. 1 unit per 2,500 square feet. This standard is
also used for multifamily dwellings.
d. Buildings up to 45 feet in height may be permitted as part of a PUD in the VMX District.
e. The front yard setback for single family homes shall be 25 feet.
e. Side yard setbacks in the VMX District apply only along lot lines abutting residentially zoned parcels
or those parcels with residential uses as the sole use.
f. Corner properties: the side yard façade of a corner building adjoining a public street shall maintain
the front setback of the adjacent property fronting upon the same public street, or the required front
Commented [EB1]: This is already indicated in 154.505
(A) (3) (b)
Planning Commission Draft 4/10/2017
7
yard setback, whichever is less. If no structure exists on the adjacent property, and provided
required setbacks are not otherwise stated herein, the setback shall be shown in the table.
g. Properties abutting CSAH 17 and CSAH 14 shall have a minimum setback standard of 30
feet.
§ 154.503 DIMENSIONAL REQUIREMENTS AND PRESERVATION OF OPEN SPACE
A. Averaging of Lot Area. When lots are clustered within a development to provide common open space,
the open space may be used to calculate an average density per lot to determine compliance with the
individual lot area requirements.
B. Lot Dimension Reductions. Other reductions in dimensional standards may be considered as part of a
Planned Unit Development if these reductions provide for common open space within a
development.
C. Village Open Space Overlay District. Development of areas within the Village Open Space Overlay
District, as designated by the Comprehensive Plan, is not allowed. Residential lots shall not encroach
on the areas designated as open space per this overlay district, unless approved by Council.
§ 154.504 GENERAL SITE DESIGN CONSIDERATIONS – LMX VILLAGE DISTRICTS
Development of land within the VMX Village Districts shall follow established standards for traffic circulation,
landscape design, and other considerations as specified in Article 5, 6 and 7.
A. Circulation. New access points to State Highway 5 County State Aid Highway 14 may be refused or
restricted to right-in right-out movement if alternatives exist. Internal connections shall be provided
between parking areas on adjacent properties wherever feasible.
1. The number and width of curb-cuts shall be minimized. To promote pedestrian circulation,
existing continuous curb-cuts shall be reduced to widths necessary for vehicular traffic, and
unnecessary or abandoned curb cuts shall be removed as parcels are developed.
B. Fencing and Screening. Fencing and screening walls visible from the public right-of-way shall be
constructed of materials compatible with the principle structure.
C. Lighting design. Lighting shall be integrated into the exterior design of new or renovated structures to
create a greater sense of activity, security, and interest to the pedestrian, and shall comply with
§150.035-150.038 Lighting, Glare Control, and Exterior Lighting Standards.
D. Exterior Storage. Exterior materials storage must be screened from view from adjacent public streets
and adjacent residential properties, by a wing of the principal structure or a screen wall constructed
of the same materials as the principal structure. Height of the structure or screen wall must be
sufficient to completely conceal the stored materials from view at eye level (measured at six feet
above ground level) on the adjacent street or property.
Planning Commission Draft 4/10/2017
8
E. Screening of Existing Residential Structures. When a new development is proposed adjacent to an existing
single family residential structure, screening shall be provided in accordance with §154.258.F. The City
may require buffering or screening above and beyond this section in cases where the required screening
will not provide an adequate separation between incompatible uses.
F. Sidewalks and/or Trails. Where cul-de-sacs are permitted by the City, sidewalks or trails are required to
connect the bulb of the cul-de-sac with the nearest through-road or trail.
G. Lake Elmo Theming Study. Elements of the Lake Elmo Theming Study not herein described
must be incorporated in to development within Village Districts where applicable.
§ 154.505 DEVELOPMENT STANDARDS FOR SPECIFIC USES
Development of land within the VMX Village d Districts shall follow established standards for traffic circulation,
landscape design, parking, signs and other considerations as specified in Articles 5, 6 and 7. The following standards
apply to specific uses; other standards related to design and building type may be found at §154.506.
A. Residential Units, Village Districts.
1. All Residential Units, Village Districts.
a. Residential housing units shall be designed to reflect the general scale and character of
the Village, including front yard depth, height and roof pitch, primary materials, facade
detailing and size and placement of window and door openings.
2. Single-Family Detached Dwellings, Village Districts.
a. No parking shall be located in the front yard or between the front façade and the
street except on a permitted driveway.
b. Primary entrances are required to be along the front façade.
c. Dwelling units shall be at least twenty-four (24) feet in width, at least nine hundred sixty
(960) square feet in area, and be placed on a permanent foundation.
3. Secondary Dwellings, Village District. Restricted to lots occupied by single-family dwellings, and
must meet the standards for secondary dwellings in residential districts, §154.13454 (C) and be
located within the primary structure.
4. Single-Family Detached and Two-Family Dwellings, VMX District.
a. Single-Family Detached Dwellings are limited to those existing at the time of adoption of this
Ordinance. Expansion of existing and new single-family detached dwellings shall be allowed
through the conditional use process. considered permitted uses, rather than nonconforming
uses.
Planning Commission Draft 4/10/2017
9
b. Unless otherwise specified in this Article, Single and Two-Family Dwellings in the VMX
district shall adhere to the MDR LDR district setbacks as specified in §154.452.
5. Single-Family Attached, VMX District.
a. A maximum of eight (8) units shall be permitted within a single building.
a. The primary entrance to each unit shall be located on the façade fronting a public street; an
additional entrance may be provided on the rear or side façade.
b. For redevelopment projects, new housing types should be introduced in limited quantities to
increase diversity and housing choice, not to replace whole blocks of existing housing.
Therefore, no more than 1/4 of the lineal frontage of a developed block (measured around the
entire block perimeter) may be converted to townhouse units, and no further townhouse, two-
family or higher-density development is permitted once this threshold is reached.
c. Common open space for use by all residents or private open space adjacent to each unit shall be
provided. Such open space shall compromise a minimum of three hundred (300) square feet per
unit.
d. No parking shall be located in the front yard or between the front façade and the street.
e. Unless otherwise specified in this Article, Single-Family Attached dwellings in the VMX
district shall adhere to the MDR district setbacks as specified in §154.452.
6. Multi-Family Dwelling Units, VMX District.
a. Dwelling units (both condominium and rental) within a mixed use development are restricted to the
upper floors or rear or side ground floors of a mixed use building.
b. Setback standards for multi-family dwellings not within a mixed use development shall be
determined through the conditional use process.
7. All Other Residential Uses, VMX District. Setbacks for all other residential uses within the
Village districts not specifically outlined in this Section shall be determined by either
154.506 or through the conditional cse process.
B. Non-Residential Uses, VMX District.
1. Setbacks, Generally. The front yard setback of a new non-residential building within the
VMX district shall maintain the prevailing front yard setback of that block, or a
maximum setback of 20 feet, whichever is less.
2. Repair and Maintenance Shop. No outdoor storage is permitted unless fully screened from public
view.
Commented [EB2]: Verifying with the City Attorney if this
is legal.
Planning Commission Draft 4/10/2017
10
3. Trade Shop. Exterior materials storage must be totally screened from view from adjacent public
streets and adjacent residential properties by a wall of the principal structure or a screen wall
constructed of the same materials as the principal structure.
4. Veterinary Services.
a. All activities must be conducted within an enclosed building.
b. Specific veterinary practices shall be limited to veterinary medicine, surgery, dentistry, and related
service for small domestic household pets.
5. Garden Center.
a. The storage or display of any materials or products shall meet all setback requirements of a
structure, and shall be maintained in an orderly manner. Screening along the boundaries of
adjacent residential properties may be required, meeting the standards of Article 6, Section
155.89.F.
b. All loading and parking shall be provided off-street.
c. The storage of any soil, fertilizer or other loose, unpackaged materials shall be contained so as to
prevent any effects on adjacent uses.
6. Automobile Maintenance Service and Automobile Parts/Supply
a. All vehicle repairs shall be conducted in a completely enclosed building
b. The storage or display of inoperable or unlicensed vehicles or other equipment shall meet all
setback requirements of a structure, and shall be totally screened from view from adjacent public
streets and adjacent residential properties.
7. Live-Work Unit. The purpose of a live-work unit is to provide a transitional use type between a home
occupation and a larger commercial enterprise, and to provide neighborhood-oriented commercial
services, while maintaining a generally residential character in which the work space is subordinate
to the residential use.
a. The work space component shall be located on the first floor or basement of the building.
b. The dwelling unit component shall maintain a separate entrance located on the front or side
façade and accessible from the primary abutting public street.
c. The work space component of the unit shall not exceed thirty (30) percent of the total gross floor
area of the unit.
d. A total of two (2) off-street parking spaces shall be provided for a live-work unit, located to the
rear of the unit, or underground/enclosed.
Planning Commission Draft 4/10/2017
11
e. The size and nature of the work space shall be limited so that the building type may be
governed by residential building codes. An increase in size or intensity beyond the specified
limit on floor area would require the building to be classified as a mixed-use building.
f. The business component of the building may include offices, small service establishments, home
crafts which are typically considered accessory to a dwelling unit, or limited retailing (by
appointment only) associated with fine arts, crafts, or personal services. It may not include a
wholesale business, a commercial food service requiring a license, a limousine business or auto
service or repair for any vehicles other than those registered to residents of the property.
g. The business of the live-work unit must be conducted by a person who resides on the same lot.
The business shall not employ more than two (2) workers on-site at any one time who live
outside of the live-work unit.
8. Parking Facility. Structured parking is permitted as a ground floor use within a mixed-use building,
provided that it is located on side or rear facades, not facing the primary abutting street. The
primary street-facing façade shall be designed for retail, office or residential use. The primary
street façade may include an entrance into the parking facility.
9. Outdoor Dining Accessory to Food Services. Outdoor dining is allowed as an accessory use in the
commercial districts, provided that tables do not block the sidewalk. A minimum of five (5) feet
of sidewalk must remain open.
§ 154.506 VMX DISTRICT DESIGN AND DEMOLITION REVIEW
A. Review of Design. For certain development activity as specified in the Lake Elmo Design Standards
Manual, design review is required as part of the approval process for a building permit, conditional
use permit, or certificate of zoning compliance under this Ordinance. All projects subject to design
review shall be reviewed for conformance with the Lake Elmo Design Standards Manual. A separate
process for design review is not established.
1. Review Authority and Process. Design review shall be the responsibility of the individual or body
authorizing the permit or certificate and shall be incorporated in the established review of the
applicable building permit, conditional use permit, or certificate of zoning compliance. For those
applications under this Ordinance that require review by the Planning Commission (i.e.
conditional use permits), the Planning Commission shall consider the standards in the Lake Elmo
Design Standards Manual as part of its recommendation to the City Council.
2. Review by Professional. The authorizing body may request review by a design professional of the
proposed design or demolition. The cost of review by such design professional shall be charged by
the applicant, and shall not exceed $1,000 unless otherwise agreed to by the applicant.
3. Development Activity Defined. Development Activity consists of new construction and
redevelopment activities, including remodeling that expands the footprint of a structure, altering, or
repairing a structure in a manner that will change the exterior appearance of said structure.
Planning Commission Draft 4/10/2017
12
Development activity also includes the construction of a new parking lots and installation of
signage.
a. Exempt Activities. The following activities shall be exempt from under review of this Section:
i. Ordinary repairs and maintenance that will not change the exterior appearance of a structure;
ii. Removal of existing signage without replacement unless said signs are an integral part of the
building;
iii. Emergency repairs ordered by the Director of Planning in order to protect public health and
safety;
iv. Exterior alteration, addition, or repair of a structure used as a single-family residence,
duplex, or two-family residence.
v. Temporary signage, installed in accordance with §154.212 of this Ordnance, or during
which time an application for permanent signage is pending under this Ordinance;
vi. Maintenance of existing signage advertising an on-site business;
vii. Alterations only to the interior of a structure.
§ 154.507 ACCESSORY USES AND STRUCTURES
Accessory uses are listed in the VMX District Use Table 11-1 as permitted or conditional accessory uses.
Accessory uses and structures in the VMX Village Districts shall comply with the following standards and all
other applicable regulations of this ordinance:
A. Phasing. No accessory use or structure shall be constructed or established on any lot prior to the
time of construction of the principal use to which it is accessory.
B. Incidental to Principal Use. The accessory use or structure shall be incidental to and customarily
associated with the principal use or structure served.
C. Subordinate to Principal Use. The accessory use or structure shall be subordinate in the area, extent, and
purpose to the principal use or structure served.
D. Function. The accessory use or structure shall contribute to the comfort, convenience, or necessity
of the occupants of the principal use or structure served.
E. Location. The accessory use or structure shall be located on the same zoning lot as the principal use or
structure.
F. Residential Accessory Structures
§ 154.5087 RESIDENTIAL ACCESSORY STRUCTURES
Planning Commission Draft 4/10/2017
13
A. 1. Design Compatibility. On parcels used for residential structures within the VMX Village
Districts, the design and construction of any garage, carport, or storage building shall be similar
to or compatible with the design and construction of the main building. The exterior building
materials, roof style, and colors shall be similar to or compatible with the main building or shall
be commonly associated with residential construction.
B. 2. Attached structures. An accessory structure shall be considered attached, and an integral part of, the
principal structure when it is connected by an enclosed passageway. All attached accessory
structures shall be subject to the following requirements:
a. The structure shall meet the required yard setbacks for a principal structure, as
established for the zoning district in which it is located.
b. The structure shall not exceed the height of the principal building to which it is attached.
B. 3. Attached Garages.
3. a. Attached garages are encouraged to be side or rear loaded. If facing the primary street, garages
shall be designed using one of the following techniques, unless specific physical conditions on
the lot in question require a different approach:
i. The front of the garage is recessed at least four (4) feet behind the plane of the primary
façade; or
ii. The front of the garage is recessed at least four (4) feet behind a porch if the garage
is even with the primary façade; or
i. Garages shall be offset from the principal structure by a minimum of two feet.
ii. The width of the attached garage shall not exceed 40% of the width of the entire
principal building façade (including garage) fronting the primary street.
4. b. Attached garages shall not exceed one thousand (1,000) square feet in area at the ground floor
level except by conditional use permit.
5. c. Garage doors or openings shall not exceed fourteen (14) feet in height.
C. 4. Detached structures. Detached accessory structures for permitted residential structures in the
VMX Village Districts must be in accordance with the following requirements:
a. Detached accessory structures shall be located to the side or rear of the principal
building, and are not permitted within the required front yard or within a side yard
abutting a street.
b. Detached garages shall not exceed one thousand (1,000) square feet at ground floor level and
shall not exceed a height of twenty-two (22) feet or the height of the principal structure,
Planning Commission Draft 4/10/2017
14
whichever is higher. The maximum size and height may be increased upon approval of a
conditional use permit, provided that lot coverage requirements are satisfied.
c. Pole barns, as defined herein, shall be prohibited.
d. No more than thirty (30) percent of the rear yard area may be covered by accessory structures.
e. Garage doors or openings shall not exceed fourteen (14) feet in height.
§ 154.509 ACCESSORY USES
A. G. Exterior Storage on Residential Parcels. All materials and equipment shall be stored within a building
or be fully screened so as not to be visible from adjoining properties, except for the following:
a. Laundry drying,
b. Construction and landscaping materials and equipment currently being used on the premises.
Materials kept on the premises for a period exceeding six (6) months shall be screened or stored
out of view of the primary street on which the house fronts.
c. Agricultural equipment and materials, if these are used or intended for use on the premises.
d. Off-street parking and storage of vehicles and accessory equipment, as regulated in Article
5, Section 155.67 154.210.
e. Storage of firewood shall be kept at least ten (10) feet from any habitable structure and screened
from view of adjacent properties.
f. Outdoor parking.
B. H. Temporary Sales. Temporary sales, also known as yard or garage sales, are permitted in all
residential districts, limited to two (2) per calendar year per residence, not to exceed four (4) days in
length for each event.
C. I. Accessory Uses and Structures Not Listed
§ 154.510 ACCESSORY USES AND STRUCTURES NOT LISTED
Standards for accessory uses and structures that are permitted in all districts, or in all residential buildings
in any district, are listed in Article 7, Specific Development Standards. These include uses such as family
and group family day care, bed and breakfast facilities, and home occupations, and structures such as
swimming pools and solar equipment.
SECTION 2. The City Council of the City of Lake Elmo hereby amends the Lake Elmo City
Code Title XV: Land Usage; Chapter154: Zoning Code; Article X: Division Into Districts;
Section 154.350 to read the following:
Zoning District R
Reference
R-2 One and Two Family Residential 154.033
GB General Business
154.034
Planning Commission Draft 4/10/2017
15
A Agriculture Article XI
RR Rural Residential Article XI
RT Rural Development Transitional Article XI
RS Rural Single Family
Article XI
RE Residential Estate
Article XI
LDR Urban Low Density Residential Article XII
MDR Urban Medium Density Residential Article XII
HDR Urban High Density Residential Article XII
V-LDR Village Limited Density Residential Article XIII
VMX Village Center - Mixed Use
Article XIII
C Commercial Article XIV
CC Convenience Commercial Article XIV
LC Neighborhood Office/Limited Commercial Article XIV
BP Business Park/Light Manufacturing Article XIV
PF Public Facilities Article XV
SECTION 3. The City Council of the City of Lake Elmo hereby amends the Lake Elmo City
Code Title XV: Land Usage; Chapter154: Zoning Code; Article VII: General Regulations;
Section 154.212: Sign Regulations; Table 5-3 to read the following:
Table 5-3 Ground Signs
Zoning District Aa, LDR, OP,
RE, RS, RRa,
RTa
MDR, HDR,
V-LDR
BP, C, CC, GB,
LC, VMX
No. of
Speed
Max Height/
Max Height/ Area
Max Height/ Area Total
Traffic Limit
Lanes (MPH) Area (Sq. Ft.) (Sq. Ft.) (Sq. Ft.)
1-3 0-34 - 6’/32 10’/32
35-44 - 6’/32 10’/50
45+ - 6’/32 10’/72
4-5 0-34 - 6’/32 10’/40
35-44 - 6’/32 10’/64
45+ - 6’/32 12’/80
Planning Commission Draft 4/10/2017
16
SECTION 4. The City Council of the City of Lake Elmo hereby amends the Lake Elmo City
Code Title XV: Land Usage; Chapter 153: Subdivision Regulations; Section 153.14: Park
Land Dedication Requirements; Subd. A to read the following:
Zoning Districts Minimum Required Land Dedication
R1, R2, R3, andR4 10%
RS, V-LDR, LDR, MDR, HDR 10%
RE 7%
RR and AG 4%
SECTION 5. Effective Date. This ordinance shall become effective immediately upon adoption
and publication in the official newspaper of the City of Lake Elmo.
SECTION 6. Adoption Date. This Ordinance 08-___ was adopted on this _____ day of
________, 2017, by a vote of ___ Ayes and ___ Nays.
LAKE ELMO CITY COUNCIL
_________________________________
Mike Pearson, Mayor
ATTEST:
__________________________
Julie Johnson, City Clerk
This Ordinance 08-__ was published on the ____ day of ___________________, 2017.
31.95
Wildflower:
Units: 145
Acres: 117
Gross Density: 1.23
Net Density: 4
Village Park Preserve
Units: 104
Acres: 64
Gross Density: 1.625
Net Density: 2.2
Easton Village
Units: 217
Acres: 98.47
Gross Density: 2.20
Net Density: 2.5
Village Preserve
Units: 91
Acres: 40
Gross Density: 2.275
Net Density: 2.64
Gonyea West (Under Contract)
Units: 213
Acres: 99
Gross Density: 2.15
Net Density: 2.5
Easton Village Parcel B
Total Acres: 45.55
Area Guided LDR: 34.86
Units Allowed by Gross Density of
1.5 - 2.49 Units/Acre:
52-86
Units Allowed by Net Density of
1.5-2.49 Units/Acre
(assuming 15% unbuildable-29.63 acres):
44-73
Easton Village Parcels A
Acres: 46
Area Guided MDR: 33.83
acres
Units Allowed byGross
Density
2.5-4.99 Units/Acre:
84-168 units
Units Allowed by
Net Density
2.5-4.99 Units/Acre:
(assuming 15% unbuildable
= 28.75 acres )
71-143
Screaton Parcel
Acres: 23.78
Units Allowed by Gross Density of
1.5 - 2.49 Units/Acre:
35-59
Units Allowed by Net Density of
1.5-2.49 Units/Acre:
(assuming 15% unbuildable=20.2 acres)
30-50
VMX-Guided Parcels:
164.4 acres
Units Allowed by Net
Density of
5-10 Units/Acre:
(assuming 15%
unbuildable=139.74 acres)
698-1397
Undeveloped Acreage: 62.8
Potential New Units in
Undeveloped Acreage
Using Density of 5-10
Units/Acre:
(assuming 15%
unbuildable=53.38 acres)
266-533
27THKE
A
T
S
24TH
MA
N
N
I
N
G
KI
M
B
R
O
32ND S T N
LE
G
I
O
N
LA
K
E
E
L
M
O
32ND
STILLW
A
T
E
R
LA
Y
T
O
N
44TH
LI
L
A
C
L
A
M
P
E
R
T
KL
O
N
D
I
K
E
31ST
KR
A
F
T
33RD
P
R
I
V
A
T
E
L
A
N
SING
30TH
M
E
N
D
E
L
44THSTREET
LI
L
Y
LISBON
AVENUE
43RD
L I S B O N
24TH
L A K E
E L M O
32ND
L A K E
E L M O
M
A
N
N
I
N
G
44TH
K
L
O
N
D
I
K
E
LEGION
30TH
MA
N
N
I
N
G
M A N N I N G
32ND
LA
K
E
E
L
M
O
30TH30TH 30TH
LI
S
B
O
N
33RD
MA
N
N
I
N
G
43RD
ST
I
L
L
W
A
T
E
R
L
I
S
B
O
N
24TH
2 4 T H
44TH
LE
G
I
O
N
LA
K
E
E
L
M
O
STILLWAT
E
R
L E GI
O N
30TH
Sources: Washington County & Metro GIS12-16-2016
5
7.51
Parcels Guided in Village District
Land Use
Expected Per Village Master Plan
Development/Parcel Under Contract, Prelim Plat or Final Plat
Planned or Approved Development
Possible Future Development
Gonyea West 213 Screaton Parcel 35 59 30 50
Village Preserve 91 Easton Village Parcel A 84 168 71 143
Wildflower 145Easton Village 217Village Park Preserve 104Total Planned/Approved Development Units:770 Possible Future Units :171 313 145 266
VMX Zoning District 200-300 Arbor Glen 48 Vacant Parcels in VMX District 266 533
Potential Redevelopment in VMX District 398 1397
Possible # of Units (based on net density) Low High
44 73
V-LDR and V-MDR Zoning Districts
800
Possible # of Units (based on gross density Low High
Easton Village Parcel B 52 86
3
Lake Elmo Planning Commission Minutes; 2-27-17
existing language that limits garage width to 40% of the width of the principal structure
in the VMX.
The Commission wanted to further research into the minimum house square footage
requirements allowed in all the zoning districts and suggested looking at the zoning
codes for progressive cities, neighboring cities and a few similar cities in the west metro.
Business Item – Zoning Text Amendment – Planned Unit Development Zoning
Planning Director Wensman introduced draft changes to the PUD ordinance. He
suggested the purpose to the changes was to add the recently approved OP PUD
process to the Article I PUD regulations. The other primary change was to eliminate the
size requirement for commercial PUDs and to allow the Planning Director to waive the
Sketch Plan requirement for small commercial PUDs when they meet the identified
objectives in Section 154.751. Wensman also mentioned that Consulting Planner Gozola
had reviewed the draft and offered some additional suggested changes. Wensman
stated he will review some of Gozolas suggestions and will incorporate them into a
future draft amendment.
Commissioner Williams wanted to revisit section 154.751, Identified Objectives. He felt
the requirement that one or more of them needing to be met was too easy for
developers. It was suggested that Planning staff research what other cities do for
establishing a basis for allowing PUDs.
Commissioner Hartley suggested that 154.752 C and D be reworded to something like
120% increase from the underlying zoning requirements.
Commissioner Williams was supportive of the draft changes to the minimum
requirements, but suggested some rewording.
Commissioner Hartley wanted 154.753 B to include public trails.
The Commission discussed potential changes to the point system in Table 16-2 and
wanted to revisit this. It was felt that Trails were a requirement already if part of a
comprehensive trail plan and that otherwise the City should not award points for them.
Business Item – Zoning Text Amendment – Solar Ordinance Discussion
Planning Director Wensman introduced the Solar Ordinance discussion asking the
Commissioners what they wanted to see changed with the City’s ordinance.
Commissioner Dorschner wanted to be sure the ordinance protected neighbors from
glare, etc. related to solar facilities. Commissioner Larson also stressed that safety was
a concern.
4
Lake Elmo Planning Commission Minutes; 2-27-17
Commissioner Williams thought the ordinance should address impervious surface
requirements. Williams also felt the City should be less concerned with the amount of
energy that can produced and more concerned about the area or size requirements and
the districts in which the facilities should be located.
Director Wensman offered that he would review the city’s ordinance against other
ordinances to create a draft ordinance that takes into consideration the Commissions’
concerns along with items generally addressed in other ordinances for future discussion.
City Council Updates – February 21, 2017 Meeting
i) OP-Alt Zoning District Repeal – passed
ii) Shoreland Management Overlay Ordinance Amendment – failed and tabled
to next meeting
iii) ZMA and CUP for 3549 Lake Elmo Ave - passed
Staff Updates
1. Upcoming Meetings
a. March 13, 2017
Planning Director Wensman informed the Commission that the Royal Golf
zoning map amendment and preliminary plat and preliminary PUD,
Inwood 5th final plat and PUD and Lakewood Crossing 2nd Concept PUD
public hearings will be held.
b. March 27, 2017
Planning Director Wensman thought that Easton Village 2 nd Addition and
Hidden Meadows 2nd Addition final plat might be reviewed at this
meeting along with business items for future ordinance amendments.
Commission Concerns
Commissioner Dodson asked to review the engineering standards for street lighting.
Commissioners Dorschner and Hartley requested updated zoning maps for their zoning
notebooks.
Meeting adjourned at 9:45 pm
Respectfully submitted,
Joan Ziertman
Planning Program Assistant
STAFF REPORT
DATE: 4/10/2017
BUSINESS
ITEM #: 5a
MOTION
TO: Planning Commission
FROM: Emily Becker, City Planner
AGENDA ITEM: Solar Energy Ordinance
REVIEWED BY: Stephen Wensman, Planning Director
BACKGROUND:
The creation of a solar garden/solar power ordinance is an item on the 2017 Planning Commission Work
Plan. The Planning Commission reviewed a draft ordinance at its March 27, 2017 meeting. Staff has
amended the proposed ordinance for the Planning Commission’s review.
ISSUE BEFORE COMMISSION:
The Planning Commission is being asked to clarify what should be included in the requested solar
garden/solar power ordinance.
PROPOSAL DETAILS/ANALYSIS:
Exemptions. The Planning Commission may wish to consider certain exemptions for the requirement that
solar energy systems adhere to the lot size and dimension standards of the zoning district in which the solar
energy system is located. The average size of an “off-the-shelf” solar panel is approximately 1 square meter
(approximately ten square feet). However, there are smaller solar panels available, and requiring that such
solar panels meet the accessory structure setback requirements of a zoning district may be unnecessary. For
example, the City had recently received an inquiry about installing a 13.2” X 11” solar panel to provide
exterior lighting to a sign. Because the Current code does not provide exemptions, this solar panel would
need to adhere to the minimum setback requirements of the zoning district in which the solar panel is being
proposed. The Commission may wish to consider adding an exemption to these requirements, based on the
size of the solar panel. Staff has proposed an exemption size of six square feet or less, but the Commission
may wish to consider a different size for exemptions.
Different Standards for Rooftop vs. Landscape. The Commission wished to designate different standards
for rooftop vs. ground solar energy systems. Language was added to clarify different standards for rooftop
and ground-mount solar energy systems.
Standards for Solar Farms. The proposed ordinance sets forth standards for solar farms. These standards
would set forth specifications for solar farms as a principal use within a zoning district. These standards
Planning Commission Meeting 4/10/2017 Business Item #5a
Page 2
would be specified in the Article of the zoning district in which solar farms would be allowed. Staff is
requesting that the Planning Commission consider if solar farms should be allowed as a conditional primary
use within a zoning district that currently exists in the city and to consider which zoning district that should
be.
Defining Off-Grid Systems. The previous ordinance exempted off-grid systems from being required to
have an interconnection agreement. The Commission asked for a definition of off-grid. Staff revised the
proposed ordinance to provide further clarification.
Additional Clarification for Impervious Surface. Staff added language to further clarify what would be
considered impervious surface for a solar energy system. This language was taken directly from the model
ordinance.
Reflectors. The Planning Commission suggested that the language in the proposed ordinance should be
amended to state that glare should be minimized from any solar energy system rather than stating that glare
shall be minimized from any solar energy system using reflectors. Staff has amended the language as such.
Restrictions from Homeowner’s Association. The Commission had requested that the solar energy
systems ordinance place restrictions on homeowner’s associations being able to forbid the installation of
solar energy systems or create design standards that effectively preclude solar energy installations. This
language has been added to the proposed ordinance.
Tax Status of Solar Farms. The Commission had questioned what the tax status of solar farms would be.
The City Assessor was contacted and stated that the land on which a solar farm in Scandia is located is
taxed commercially.
FISCAL IMPACT:
None.
OPTIONS:
The Commission may wish to:
Specify desired amendments or additions to the Zoning Code regarding solar garden/solar power
ordinance.
Not recommend amending current standards or adding new ones.
ATTACHMENTS:
Draft Ordinance
1
CITY OF LAKE ELMO
COUNTY OF WASHINGTON
STATE OF MINNESOTA
ORDINANCE NO. 08-___
AN ORDINANCE AMENDING THE LAKE ELMO CITY CODE OF ORDINANCES BY
ADDING ADDITIONAL STANDARDS FOR SOLAR ENERGY SYSTEMS.
SECTION 1. The City Council of the City of Lake Elmo hereby amends Title XV: Land
Usage; Chapter 154: Zoning Code; Article II; Section 154.012; Subd. (B) (12) by amending
the definition of Solar Equipment and adding one definition relating to solar energy
systems:
Solar Farm. A commercial facility that converts sunlight into electricity, whether by
photovoltaic (PV), concentrating solar thermal devices (CST), or other conversion technology,
for the principal purpose of wholesale sales of generated electricity to off-site customers.
Solar Equipment Energy System. Any solar collector, skylight, or other solar energy device
whose A device or structural design feature, a primary purpose of which is to provide for the
collection, storage, and distribution of solar energy for space heating, cooling, water heating,
providing daylight for interior lighting, or for power generation.
SECTION 2. The City Council of the City of Lake Elmo hereby amends Title XV: Land
Usage; Chapter 154: Zoning Code; Article II; Section 154.310 (C) to read as follows.
Solar Energy Systems. Solar energy systems and solar structures are permitted accessory uses in
all districts, provided the system or equipment is in compliance with minimum lot requirements
and setback standards set forth below.
1. Rooftop Solar Energy Systems.
a. These systems are permitted accessory uses in all districts in which buildings are
permitted.
b. Visibility, Commercial Installations. Commercial rooftop systems shall be placed
on the roof to limit visibility from the public right-of-way or to blend into the roof
design, provided that minimizing visibility still allows the property owner to
reasonably capture solar energy.
2. Ground-Mount Solar Energy Systems.
a. Ground-mount energy systems are permitted accessory uses in all districts where
buildings are permitted.
b. A solar structure Ground-mount energy systems must comply with all accessory
setback, height and lot coverage restrictions unless otherwise stated herein or a
variance is granted and shall not encroach on any City easement unless an
easement encroachment agreement approved by the Planning Director or his/her
designee after review and approval from the City Engineer or his/her designee has
been executed. A certificate of zoning compliance is required for all solar energy
systems unless a conditional use permit is required as stated herein.
Commented [EB1]: “Solar structure” is not defined in the code.
“Solar Energy System” is now defined, and so was kept. “Solar
energy systems” is sufficient to meet the intent of what is trying to
be said here.
2
i. The collector surface of a ground-mount system and any foundation,
compacted soil, or other component of the solar installation that rests on
the ground is considered impervious surface. Vegetated ground under the
collector surface can be used to mitigate stormwater runoff.
c. Exemptions. Solar energy systems of a size of six square feet or less may be
exempt from zoning district setback requirements.
3. Interconnection Agreement. All electric solar energy systems that are connected to the
electric distribution or transmission system through the existing service of the primary
use on the site shall obtain an interconnection agreement with the electric utility in whose
service territory the system is located. Solar energy systems connected directly to the
distribution or transmission system must obtain an interconnection agreement with the
interconnecting electric utility. Systems that are not directly connected to the grid or not
connected to the electric system of a building that is connected to the gird are exempt
from this requirement.
4. Glare. Glare produced from any solar energy system shall be minimized from affecting
adjacent or nearby properties. Measures to minimize glare include selective placement of
the system, screening of the solar array, modifying the orientation of the system, reducing
use of the reflector system, or other remedies that limit glare.
a. Mirror Reflecting Designed Solar Energy Systems. Mirror reflecting designed
solar energy systems are permitted only on properties with five (5) acres or larger.
A conditional use permit is required and more restrictive setback standards may
be required upon review of the conditional use permit.
5. Code Requirements. Electric solar system componements that are connected to a building
electric system must have an Underwriters Laboratory (UL) listing. All solar installations
must comply with the Minnesota and National Electric Code. All rooftop or building
integrated solar energy systems require a building permit and shall comply with the
Minnesota Building Code. Solar thermal hot water systems shall comply with applicable
Minnesota State Plumbing Code requirements.
6. Decommissioning. A decommissioning plan shall be required to ensure that facilities are
properly removed after their useful life. Decommissioning of solar panels must occur in
the event they are not in use for 12 consecutive months. The plan shall include provisions
for removal of all structures and foundations, restoration of soil and vegetation and a plan
ensuring financial resources will be available to fully decommission the site. The City
may require the posting of a bond, letter of credit or the establishement of an escrow to
ensure proper decommissioning.
7. Easements Allowed. Solar easements may be filed, consistent with Minnesota Stat.
Chapter 500 Section 30. Any building owner can purchase an easement across
neighboring properties to protect access to sunlight. The easement is purchased or
granted by owners of neighborhing properties and can apply to buildings, trees, or other
structures that would diminish solar access.
8. Restrictions on Solar Energy Systems Limited. No homeowners’ agreement, covenant,
common interest community, or other contract between multiple property owners within
a subdivision shall forbid installation of solar energy systems or create design standards
that effectively preclude solar energy installations.
SECTION 3. The City Council of the City of Lake Elmo hereby amends Title XV: Land
Usage; Chapter 154: Zoning Code; Article __: ________; Section ________: Development
Standards for Specific Uses to read as follows.
3
____. Solar Farm.
1. Conditional Use Permit. A conditional use permit is required.
2. Stormwater and NPDES. Solar farms are subject to the City’s and watershed district’s
stormwater management and erosion and sediment control provisions and NPDES permit
requirements.
3. Foundations. A qualified engineer shall certify that the foundation and design of the solar
panels, racking and support is within accepted professional standards, given local soil and
climate conditions.
4. Power and communication lines. Power and communication lines running between banks
of solar panels and to nearby electric substations or interconnections with buildings shall
be buried underground. Exemptions may be granted by the City in instances where
shallow bedrock, water courses, or other elements of the natural landscape interfere with
the ability to bury lines, or distance makes undergrounding feasible, at the discretion of
the Planning Director.
SECTION 2. Effective Date. This ordinance shall become effective immediately upon
adoption and publication in the official newspaper of the City of Lake Elmo.
SECTION 43 Adoption Date. This Ordinance 08-___ was adopted on this ______ day of ___
2017, by a vote of ___ Ayes and ___ Nays.
LAKE ELMO CITY COUNCIL
_________________________________
Mike Pearson, Mayor
ATTEST:
_________________________________
Julie Johnson, City Clerk
This Ordinance 08-____ was published on the ____ day of ___________________, 2017.
STAFF REPORT
DATE: 4/10/17
REGULAR
ITEM #: 5b
MOTION
TO: Planning Commission
FROM: Stephen Wensman, Planning Director
AGENDA ITEM: Landscape Design Standard Details and Specifications
REVIEWED BY: Emily Becker, City Planner
Stephen Mastey, Consulting Landscape Architect.
BACKGROUND:
On a periodic basis, the City’s Landscape Design Standard Details and Specifications are
updated and approved by the City Council. As part of that process it was requested that the
Planning Commission review them and make a recommendation to the City Council. This year,
the landscaping and irrigation design standard details and specifications, have been removed
from the Engineering Standards and these have been updated and incorporated into their own
freestanding set of standard details and specifications.
ISSUE BEFORE THE COMMISSION:
To review the Landscaping Design Standard Details and Specifications and provide a
recommendation to the City Council.
PROPOSAL DETAILS/ANALYSIS:
Landscape Standards (900 series). The new series include updated details for deciduous,
coniferous trees and shrubs for flat and sloped site planting. The tree protection detail was also
moved into the landscape standards. The landscape standards also include required and
recommended details for landscape irrigation. The required irrigation details include the water
service and controller details that illustrate the required connections to Municipal Water
consistent with City Council’s direction in 2016 when reviewing and adopting the irrigation
standards. The recommended details illustrate best practices in landscape irrigation and these
details are taken from the 5th Street project, where irrigation was required. All the irrigation
standard details refer to updated irrigation specifications. Other improvements to the details
include:
To be current with MN Department of Transportation Standard Specifications for
Construction 2016 Edition;
To be current with the latest edition of American Standard for Nursery Stock
(ANSI Z60.1);
Planning Commission Meeting
4/10/17 Business item #5b
Page 2
To clarify and provide additional guidance on incorrect planting practices that
have been observed from time on time projects within in the City specifically on
City owned property / right of way;
Provide guidance within the irrigation specification and details to help further
protect the City’s potable water resources; and
To be current with updated technology advances within the irrigation industry
specifically in the areas of energy efficiency, water conservation, improved
watering that coincides with better plant health and increased sustainability of the
irrigation products and systems supplied.
FISCAL IMPACT:
None
RECOMMENDATION:
Staff recommends that the Planning Commission recommend approval of the Landscaping Design Standard
Details and Specifications with the following motion:
“Move to recommend approval of the Landscaping Design Standard Details and Specifications.”
ATTACHMENTS:
Landscaping Standard Details and Specifications
STAFF REPORT
PLANNING COMMISSION
DATE: 04/10/2017
ITEM #: 5b
AGENDA ITEM: Engineering Design and Construction Standards Manual – March 2017 Revisions
SUBMITTED BY: Jack Griffin, City Engineer
REVIEWED BY: Kristina Handt, City Administrator Rob Weldon, Public Works Director
Stephen Wensman, Planning Director
Chad Isakson, Assistance City Engineer
BACKGROUND: The City has prepared and maintains engineering design standards, standard
specifications, and standard details for public infrastructure within the City, including streets, sanitary
sewer, watermain, storm water facilities, right-of-way management and boulevard layout. This information
is compiled into an Engineering Design and Construction Standards Manual for use by staff and the
development community. The latest version of the Manual is dated February 2015.
The standards have been established to set minimum requirements to be met for all public infrastructure
projects in the City with the intent of constructing consistent and compatible infrastructure systems
throughout the community; to clearly communicate with the development community these minimum
expectations and requirements; and to expedite plan design, preparation and City plan review and approvals.
The engineering design standards and guidelines have been established to address the most common project
elements and are to be used in conjunction with the requirements set forth by applicable codes, laws and
ordinances, recognized industry standards, good engineering practice and specific project needs. Omission
of reference in these standards and guidelines does not relieve responsibility for compliance with these
requirements. In addition, the provisions of these standards and guidelines are not intended to prohibit the
use of alternative systems, methods or components. Professional engineering judgement and ingenuity is
encouraged to adapt to specific project needs. However, varying from the standards and guidelines will
only be permitted with the approval of the City Engineer, after performing due diligence to ensure the
design is equivalent or superior to the prescribed elements of the guideline.
ISSUE BEFORE THE COMMISSION: Staff respectfully requests that the Planning Commission review
and recommend approval of the March 2017 revisions to the Engineering Design and Construction
Standards Manual.
PROPOSAL DETAILS/ANALYSIS: The Engineering Design and Construction Standards Manual is a
living document that is reviewed and modified from time to time by the City Engineering team to adapt
pro-actively to changing conditions so as to remain current, address best practices and extract additional
economic value and performance as needed. Changes are often based on recommendations from Planning,
Public Works or other City staff, the development community, and other stakeholders. Changes made by
the City Engineer over time are periodically brought forward as revisions to the Engineering Design and
Construction Standards Manual to formalize the City’s approval.
The Engineering Design and Construction Standards Manual dated March 2017 includes the following
revisions and updates:
Plan Format Requirements.
1. Updated the Plan Format requirements to require electronic plans for a complete submittal.
2. Removed reference to City benchmark system.
3. Added requirement to provide “All proposed lot corner elevations” as part of the grading plans.
4. Revised section IV. F. to clarify NWL and HWL plan requirements and require HWL contours.
5. Updated the Plan Format requirements to clarify record drawing requirements.
o Revised II. A. to remove house pad as-built elevations.
o Deleted II. M. requiring shots sufficient to produce 2 ft. contours.
o Revised II. N. grade tolerance language to indicate areas outside of tolerance “may” be
subject to revisions/re-work.
o Added III.F. “Ties for draintile cleanouts to permanent structures.”
Design Standards.
1. Clarified local street widths for a) parking both sides b) parking one side and c) no parking.
2. Added minimum tangent requirements at local street intersections.
3. Collector street and right-of-way widths were changed to “case by case basis”.
4. Changed drain tile pipe to PVC schedule 40.
5. Sign post standards were changed per direction of Public Works.
6. Clarified the City street light fixture and pole requirements.
7. Revised tracer wire requirements to be 12 AWG and added Drive-in Magnesium Grounding Anode
Rod requirements to assist Public Works with utility locates.
8. Changed the minimum watermain pipe size to 6-inch diameter when allowed by the City Engineer.
9. Maximum length of pipe at dead ends. Changed to 1,000 feet.
10. Added 4-foot Sump Manhole requirement to be consistent with VBWD standards.
11. Stormwater BMPs.
o Changed Pretreatment forebay to no longer be “Required”.
o Added Clay Pond Liner specifications for wet ponds to meet VBWD standards.
o Removed infiltration basin plantings to reference approved Landscape Plan.
o Revised and detailed infiltration basin boring requirements.
12. Updated City Low Impact Development practices language.
13. Removed landscaping details.
14. Update detail plate index.
15. Unresolved items.
o Review/revise turning radius at intersections w/center medians. Snow plow issues.
Standard Details.
1. Revised all Standard Details to “MARCH 2017” and updated the index details to reflect updated
numbering system.
2. 201 – Added hydrant concrete splash pad per Public Works request.
3. 203 – Revised gate valve key requirements per Public Works request.
4. 208 – Added note to reference Landscape Irrigation Standards for work by Private Contractor.
5. Added tracer wire requirements for utility locate assistance. Details provided by Public works.
o 300A – Added tracer wire note.
o 313 – Added access box and grounding rod detail.
o 315 – Added detail for tracer wire plan view.
6. 416 – Revised minimum pond depth to 3-feet to match design standard.
7. 419 – Changed draintile pipe to Schedule 40 PVC.
8. 505 – Updated valley gutter detail to 6 foot width and removed mesh.
9. 507A, 507B, 507C, 507D, and 507E. Added MnDOT Pedestrian ramp standard detials.
10. 509 – Updated standards trail width to 8 feet from 8-1/2 feet.
11. 514 – Added new detail for bituminous saw and seal requirements for residential streets.
12. 600D – Removed comment #5 requiring placement of 2 rows of sod and silt fence.
13. 801 – Updated draintile note to schedule 40 pipe.
14. 804 – Updated draintile note to schedule 40 pipe.
15. 805 – Removed reference for the placement of 2 rows or sod/silt fence.
16. 807A – Added detail for Temporary Cul-De-Sac Type A.
17. 807B – Added detail for Temporary Cul-De-Sac Type B.
18. Removed Section 900 Landscape/Irrigation details to be located in Landscape Standards Manual.
19. Created new Section 900 for Signing/Pavement Markings/Lighting.
20. Added Detail 902 and 903 to detail new street and traffic sign post standards per Public Works.
Standard Specifications.
1. Revised all Standard Specifications to “MARCH 2017”.
2. Section 1450 – Included Modified Penetration Test for Aggregate Base Compaction (industry
standard by Geotech field technicians).
3. Section 3217 – Revised pavement marking materials (Section 4.C.).
4. Removed 3290 (Landscape Plantings). Moved Prairie Style turf to turf establishment section.
5. Section 3307 – Tracer wire changed to 12 gauge per manufacturer’s recommendation.
6. Section 3330 – Added tracer wire requirements per direction of Public Works. Using MWRA
specifications incorporated. Grounding rod/access box at every service.
7. Section 3340 – Revised spec to address new MDH requirement for watertight connection on all
storm sewer structures within 10 feet of watermain.
8. Section 3346 – Revised spec for draintile to be Schedule 40 PVC.
9. Section 3440 – Revised sign posts per Public Works new standards and to match new details.
RECOMMENDATION: Staff is recommending that the Planning Commission recommend approval of
the March 2017 revisions to the Engineering Design and Construction Standards Manual. The
recommended motion for the action is as follows:
“Move to recommend approval of the March 2017 revisions to the
Engineering Design and Construction Standards Manual.”
ATTACHMENTS:
1. Plan Format Requirements – Redlines showing changes from February 2015 to March 2017.
2. Engineering Design Standards – Redlines showing changes from February 2015 to March 2017.
3. Standard Details – New details 201, 208, 315, 514, 807A, 807B, 902, and 903.
*The full Engineering Design and Construction Standards Manual, dated March 2017 is available for
review at City Hall.
City of Lake Elmo Revision Date: March 2017February 2015 Page 1 of 7
Plan Sheet Format Requirements
PLAN SHEET FORMAT REQUIREMENTS
for
CITY OF LAKE ELMO
This document outlines the required plan format and minimum acceptable plan sheet requirements
for each development project within the City of Lake Elmo. The minimum requirements shall be met
for all projects before approval may be granted by the City Engineer.
Plan submittals will not be considered received until all plan formats have been submitted to the City.
All submittals and resubmittals shall include full size plans (22” x 34”), half size plans (11” x 17”) and
electronic plan files in PDF format.
GENERAL REQUIREMENTS:
1. Plan sheet size shall be 22” x 34” and 11” x 17”.
2. All Plans shall be submitted in electronic PDF format.
2.3. All electronic CAD/GIS files, when required, must be accompanied by a “layer description list”
that clearly identifies the elements of each layer or level.
3. Vertical control of Construction Record Drawings must be on the City’s Benchmark System.
CONSTRUCTION PLANS: The following plan sheets shall be bound together in one plan set and
distributed to the City in the number and plan size as required.
I. Title Sheet
A. Location Map with Section, Range and Township provided.
B. Sheet Index.
C. Plan Date with all Revision Dates.
D. Preparer’s Name and Contact Information.
E. Owner’s Name and Contact Information.
II. Legend and Typical Sections
A. Plan Legend for all Applicable Symbols.
B. City of Lake Elmo Typical Sections as Applicable to the Project.
C. Additional Typical Sections as Deemed Appropriate by the Design Engineer.
III. Standard Details and Storm Sewer Construction Chart
A. City of Lake Elmo Standard Details as Applicable to the Project.
B. Additional Standard Details as Deemed Appropriate by the Design Engineer.
C. Storm Sewer Construction Chart.
IV. Grading, Drainage, and Erosion Control Plans
A. North Arrow (Up or to the right on all sheets).
B. Scale: 1”=50’ horizontal.
C. Maximum plan sheet size 22” x 34”.
Formatted: Top: 0.6", Bottom: 0.6", Footer distance from
edge: 0.41"
Formatted: Indent: Left: 0.25"
City of Lake Elmo Revision Date: March 2017February 2015 Page 2 of 7
Plan Sheet Format Requirements
D. Building pads with garage floor elevation, low floor elevation, low opening elevation and
building type.
E. All proposed lot corner elevations.
E.F. Wetland delineations and wetland buffers, creeks, streams, lakes & other water bodies.
G. Existing and proposed normal water level (NWL) and high water level (100‐year HWL) for
all water bodies within and adjacent to the property, including proposed high water level
(100‐year HWL) for infiltration basins.
H. Proposed high water level (100‐year HWL) contour for all storm water ponds and
infiltration basins.
F. Normal water level (NWL) and high water level (100‐year HWL) for all water bodies within
and adjacent to the property.
G.I. All emergency overflow elevations, placed in BOLD on the plans.
H.J. All erosion control measures, permanent and temporary.
I.K. Grading and erosion control City standard plan notes.
J.L. Tree protection fencing.
K.M. Spot elevations for significant trees to be saved.
L.N. Retaining Walls (wall heights and elevations).
M.O. Existing storm sewer, drainage and culvert structures to a distance of 150 feet beyond
plat boundary with pipe material, size and inverts.
N.P. Topographical features to a distance of 150 feet beyond plat boundary (fences, trails,
sidewalks, streets, driveways, etc.)
O.Q. Property, right‐of‐way and easement lines.
P.R. Existing street and driveway widths with type of surface identified.
V. Sanitary Sewer and Watermain Plan Sheets:
A. Plan and Profiles for Sanitary Sewer and Watermain shall be placed on the same sheet(s).
B. The following information shall be shown:
1. North Arrow (Up or to the right on all sheets).
2. Scale: 1”=50’ horizontal and 1”=10’ or 1”=5’ vertical (Maximum sheet size 22” x 34”)
3. Street names & right‐of‐way lines.
4. Lot and block numbers.
5. Location of all existing utilities with pipe material and size.
6. Existing and proposed easements.
7. Size of mains.
8. Material and Class of pipe.
9. Length of mains and each sanitary sewer pipe segment.
10. Size and type of manholes.
11. Proposed grade of each sanitary sewer pipe segment.
12. Elevation of inverts of all sanitary sewer lines, at MH and at stub ends.
13. Arrows indicating the direction of flow on the sanitary sewer plan views.
14. Number each sanitary sewer structure on both plan and profile views.
15. Stationing of sanitary sewer structures on profile view.
16. Proposed main line pipe crossings on the profile views.
17. Proposed storm sewer shown in plan and profile views (background view).
18. Service locations and wye stationing on the plan view (from the main line to
the utility easement line).
City of Lake Elmo Revision Date: March 2017February 2015 Page 3 of 7
Plan Sheet Format Requirements
19. Proposed invert elevations at the utility easement line. Risers must be listed for
each lot if needed.
20. Elevation of the top of the water service stop box at the utility easement line.
21. Hydrant, valve and fitting locations on the plan view (gate valve or butterfly
valve noted as applicable).
22. Proposed and existing pump or lift stations.
23. Proposed and existing Well Pumphouses.
24. Existing grade profile over main line pipe.
25. Finished grade profile over main line pipe.
26. Centerline stationing at 100 foot minimum intervals.
27. Sanitary Sewer City Standard Plan Notes.
28. Watermain City Standard Plan Notes.
VI. Street and Storm Sewer Plan Sheets:
A. Plan and Profile shall be shown on the same sheet.
B. The following information shall be shown:
1. North Arrow (Up or to the right on all sheets).
2. Scale: 1”=50’ horizontal and 1”=10’ or 1”=5’ vertical (Maximum sheet size 22” x 34”)
3. Street names.
4. Lot and block numbers.
5. Existing and proposed easements/right‐of‐ways.
6. Show concrete walks and bituminous paths.
7. Sizes of storm sewer pipe.
8. Material and Class of storm sewer pipe.
9. Length of each storm sewer pipe segment.
10. Proposed grades of each storm sewer pipe segment.
11. Proposed drainage swale locations, elevations, and grades.
12. Elevations on all inverts and castings of all storm sewer structures.
13. Arrows indicating the direction of flow on the storm sewer plan views.
14. Number of each storm sewer structure on both plan and profile views.
15. Proposed watermain and sanitary sewer shown in plan and profile views.
16. Proposed pipe crossings on the storm sewer profile views.
17. Existing grade profile over storm sewer pipe.
18. Finished grade profile over storm sewer pipe.
19. Finished centerline street elevations every 50 feet minimum.
20. Centerline stationing.
21. Street grades on profile.
22. Vertical curve data on profile.
23. Horizontal alignment and curve data on plan view.
24. Top of curb elevations at the beginning, mid‐point and end of all radii and at all
intersections where drainage is a concern, at maximum or at minimum grades.
25. Drainage flow arrows at street intersections.
26. Finished profile for centerline of trails (plan and profiles for trails may be on
separate sheets from street and storm sewer plans).
27. Storm Sewer City Standard Plan Notes.
28. Sidewalk and Trail City Standard Plan Notes.
C. Draintile Information to be Shown:
City of Lake Elmo Revision Date: March 2017February 2015 Page 4 of 7
Plan Sheet Format Requirements
1. Size, type and location of pipe on plan view.
2. Locations of service wyes and clean‐outs.
3. Arrows indicating the direction of flow on the draintile.
VII. Cross Sections
A. Cross sections shall be provided for all street reconstruction work, turn lanes, or when
interfacing new streets along existing streets and roadways.
B. Cross sections shall be provided for all trails, except when the trail is placed in the
boulevard in accordance with a typical standard street section.
C. At a minimum, each cross section shall show the following:
1. Finished ground to the match points of existing grade.
2. Existing ground.
3. Right‐of‐way and easement locations.
4. Centerline of proposed improvement.
5. Full depth proposed section.
6. Label all slopes proposed at maximum grades.
D. When provided, cross sections shall be shown a minimum of every fifty (50) feet, at all low
points, critical drainage locations, driveways, and at intersections.
VIII. Street Signage, Lighting, and Pavement Marking Plan
A. Signing, Pavement Markings, and Lighting City Standard Plan Notes.
IX. Landscape Plan Sheets
A. Irrigation Systems.
B. Include tree removals, planting schedule, and tree replacement plan.
C. Include City Standard Landscaping Plan Notes.
City of Lake Elmo Revision Date: March 2017February 2015 Page 5 of 7
Plan Sheet Format Requirements
RECORD DRAWINGS: Record drawings must be completed and submitted to the City Engineer to
a s s i s t t h e C i t y i n t h e r e v i e w , verification and acceptance of the work completed. The submittal
i n f o r m a t i o n o u t l i n e d b e l o w i s c o n s i d e r e d t h e m i n i m u m d o c u m e n t a tion requirements. The City
Engineer may request additional information specific to the improvements as deemed reasonably
necessary to verify the work conforms to the approved grading and construction plans.
I. Submittal Requirements:
A. As‐built Construction Plans shall be certified by the engineer and prepared in accordance
with the Plan Sheet Format Requirements.
B. All changes from the final construction plans should be indicated on the as‐built
Construction Record Drawings. All changes shall be lined out and corrections shall be
shown in bold italics.
C. Each Record Drawing shall list Contractor’s name, Developer Engineer’s name, City Project
Number, Construction Completion Date, and Record Plan Drawing Number (provided by City).
D. Final record drawings shall be submitted as one (1) set of full size plans (22” x 34”), two
11” x 17” paper copies, and submitted in electronic form (CD) with DWG files and PDF files
that are printable to scale on 11”x17”.
E. As‐built surveyed information shall tie out to benchmarks as indicated on the plans.
F. GIS shape files must be provided to include all as‐built public infrastructure data.
II. Certified Record “As‐built” Grading Plan shall include:
A. Location and as‐built elevations at lot corners and house pads.
B. Location and as‐built elevations along all swales, berms, slopes and ditches.
C. Location and as‐built elevations at all emergency overflow (EOF) points.
D. All finished grades for pond cross sections.
E. Location and as‐built elevations at high water levels (HWL) for ponds and low points.
F. Location and as‐built for all storm sewer structures including inverts and overflows.
G. Location and as‐built elevations at all retaining walls, including top and bottom of wall at
maximum wall height locations.
H. Location and as‐built elevations for any private wells or wastewater systems.
I. Location and as‐built elevations for other features critical to drainage performance.
J. Contours for all HWL, wetland, and other water bodies, buffers and setbacks.
K. Property lines and easements.
L. Location of all existing utilities.
M. Sufficient as‐built elevation shots to substantiate 2‐foot contour lines.
M. As‐built grading plan must conform to the approved final grading plan. As‐built elevation
shots not within +/‐ 0.2 feet of proposed elevations are subject to rejection and re‐work at
the discretion of the City Engineer.
N. As‐built elevation shots must be within +/‐ 0.2 feet of proposed elevations.
O.
III. Certified Record “As‐built” Construction Plans shall include:
A. As‐built surveyed elevations for sanitary and storm sewer manhole and catch basin
casting/inlet tops and inverts, flared end section inverts, and any other structure
elevations shown on the as‐bid drawings. Actual elevations must be recorded to the
nearest 0.01 foot, and the actual pipe grades recorded to the nearest .01%.
B. Sanitary and storm sewer lines field measured from center of casting to center of casting
or from center of casting to end of flared end. Record lengths to nearest 0.5 foot.
Formatted: Indent: Left: 0.5", No bullets or numbering
City of Lake Elmo Revision Date: March 2017February 2015 Page 6 of 7
Plan Sheet Format Requirements
C. All changes from planned pipe, structure, or hydrant locations.
D. Measured distances from center of casting to end of stubs for sanitary and storm sewer.
E. Ties from ends of watermain stubs to permanent structures.
F. Ties for draintile cleanouts to permanent structures.
E.
F.G. Service ties for the curb box for each lot. Including pipe quantity, size and type on
plans.
G.H. All sewer services with stationing from downstream manhole to wye location. Pipe
quantity, type and invert elevation at utility easement line shall be shown on the property
served.
H.I. Location of watermain fittings (i.e. bends, tees, etc.).
I.J. Top nut of hydrant elevations.
J.K. All pipe insulation.
K.L. As‐built surveyed elevations for top of curb in sufficient quantity to verify street grades.
L.M. All lot address numbers shown on both utility and street record plans.
IV. Private Water/Wastewater Facilities: Record drawings shall be provided in the format
consistent with the requirements for public infrastructure as prescribed herein:
A. Tie information for all underground structures.
B. Location and as‐built elevations for any system structures, pipes, pipe slopes, pipe lengths,
valves, clean‐outs, and other facilities.
C. Property lines and easements for the facilities.
D. Detail on the plans any revisions or deviations from the approved design.
E. Operation & Maintenance manual including:
1. Operational performance characteristics for all pumps.
2. All electrical and control information including electrical console schematics.
3. All mechanical information, parts data, and operational instructions.
4. Facility Operation instructions and procedures.
5. Emergency mitigation measures.
6. Chemical treatment schedules.
7. Permit documentation and reporting requirements.
V. Public Infrastructure Inventory Requirements: Final quantity tabulations shall be submitted for
the following information:
A. Sanitary Sewer Pipe, by footage and pipe size.
B. Watermain, by footage and pipe size.
C. Number of Hydrants, Gate and Butterfly Valves, Manholes, Catch Basins, and Lift Stations.
D. Number of Sanitary Sewer Services, by pipe size.
E. Number of Water Services, by pipe size.
F. Number of Drain Tile Services, by pipe size.
G. Storm Sewer Pipe, by footage and pipe size.
H. Number of Pollution Control Structures (Sumps, Grit Chambers, Pond Skimmers), by type.
I. Number of Ponds and Sedimentation Basins, by type. Each listed with water surface area
and volume at NWL and HWL.
J. Number of Storm Sewer Outlet Structures, by size.
K. Number of Alternative Stormwater Drainage Facilities (BMP’s), by type of BMP.
L. Public Streets by lineal footage and square yard.
City of Lake Elmo Revision Date: March 2017February 2015 Page 7 of 7
Plan Sheet Format Requirements
M. Private Streets by lineal footage and square yard.
N. Sidewalks by lineal footage and square yard.
O. Trails by lineal footage and square yard.
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 1 of 9
ENGINEERING DESIGN STANDARDS
for
CITY OF LAKE ELMO
STREET DESIGN AND GEOMETRICS
Geometric Design, Local Residential Street
‐Minimum Street Width, back of curb to back of curb…………………… ………………………..….…28‐feet
‐Minimum Street Width (B‐B), parking one side (when allowed by City)…..……………..….…24‐feet
‐Minimum Street Width (B‐B), no parking (when allowed by City)……….……………………..…22‐feet
‐Minimum Street Width, one‐way lanes with center median…………….…………………………..19‐feet
‐Center Crown……………………………………………………………………………………………………………………2.5%
‐Minimum Longitudinal Grade……………………………………………………………………........................0.5%
‐Maximum Longitudinal Grade……………………………………………………………………………………………..8%
‐Maximum Intersection Approach Grade, First 50‐
feet………………………………………..…………….2.05%
‐Minimum Vertical Curve Length, Crest (including stop conditions).………………………….………K=19
‐Minimum Vertical Curve Length, Sag (including stop conditions)………………………………..……K=37
‐Minimum Horizontal Curve Radius………………………………………………………..………............….90‐feet
‐Intersection Angles………………………………………………………………………………………………...90 degrees
‐Tangent Length at Intersection from Curb Line, Local Streets…………………………………..…..50 feet
‐Tangent Length at Intersection from Curb Line, Higher Class Streets…….......................100 feet
‐Tangent Minimum between curves……………………………………………………………………..……….50 feet
‐Minimum Intersecting Street Offset, from Centerlines……………………………………………….150‐feet
‐Curb Radius, Minimum Local to Local…………………………………………………………………….…….20‐feet
‐Curb Radius, Minimum Local to Collector…………………………………………………………………....25‐feet
‐Minimum Diameter of Cul‐de‐sac……………………………….………………………………………………..90‐feet
‐Minimum Grade around Cul‐de‐sac…………………….............................................................…0.5%
‐Maximum Cul‐de‐sac Street Length (lots less than 2.5 acres)………………………................600‐feet
‐Maximum Cul‐de‐sac Street Length (lots equal or greater than 2.5 acres)……………....1,320‐feet
‐Temporary Cul‐de‐sac at plat line……………………………………………………………………….……..Required
Geometric Design, Collector Street
‐Design Standards………………………………………………Meeting State‐Aid for minimum design speed
‐Minimum Street Width, back of curb to back of curb………………..……..…………Varies (as
determined by City36‐feet min)
‐Maximum Longitudinal Grade…………………………………………………………………………………………..…6%
‐Intersection Angles………………………………………………………………………………………………...90 degrees
‐Tangent Length at Intersection from Curb Line, Local Streets…………………………………..…..50 feet
‐Tangent Length at Intersection from Curb Line………, Higher Class
Streets……………………………..….........................100 feet
‐Tangent Minimum between curves……………………………………………………………………..……….50 feet
‐Minimum Vertical Curve Length, Sag and Crest…….………..Meeting State‐Aid for minimum
design speed
‐Minimum Vertical Curve Length, Sag………………..Meeting State‐Aid for minimum design speed
Formatted: Top: 0.44", Footer distance from edge: 0.2"
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 2 of 9
‐Minimum Horizontal Curve Radius……………………Meeting ……………….State‐Aid for minimum
design speed
‐Minimum Intersecting Street Offset, if allowed, from Centerlines……..……..……………….250‐feet
‐Street/Roadway Access………………………………..Per City Access Management Spacing Guidelines
‐Driveway Access, Residential……………………….…………………………………………….…………...Prohibited
‐Driveway Access, Commercial…………….………..Per City Access Management Spacing Guidelines
‐Curb Radius....………………………………………………………………………………………………………….…..25‐feet
Pavement Section Design (Pavement sections below are minimum allowed. Additional pavement
section may be required based on Geotechnical Report of the subgrade soils).
‐Local Residential Street……………………………………………………………………….Minimum 7‐Ton Design
‐Subbase, Select Granular Borrow (SPEC 3149.2B)…….………………………….……Minimum 12‐inches
‐Subsurface Drainage System…………………………………………………………………………………..….Required
‐Base, Aggregate Base, Cl. 6 100% Crushed Stone Aggregate..……………………..Minimum 6‐inches
Note: Class 6 Recycled Material Substitute by City Engineer Approval
‐Non‐Wearing Course, MnDOT 2360 Type SP 12.5, Mixture 2B….……….…..….…………..2‐inches
‐Wearing Course, MnDOT 2360 Type SP 9.5, Mixture 2B..……………………..………………….1½‐inches
‐Collector Street and Above…………………………………………………………….….Minimum 10‐Ton Design
‐Subbase, Select Granular Borrow (SPEC 3149.2B)…….………………………….……Minimum 12‐inches
‐Subsurface Drainage System…………………………………………………………………………………..….Required
‐Base, Aggregate Base, Cl. 6 100% Crushed Stone Aggregate..……………………..Minimum 8‐inches
Note: Class 6 Recycled Material Substitute by City Engineer Approval
‐Non‐Wearing Course, MnDOT 2360 Type SP 12.5, Mixture 3C….……….…..…………………..2‐inches
‐Wearing Course, MnDOT 2360 Type SP 9.5, Mixture 3C..……………………..…………………….2‐inches
Draintile/Street Subsurface Drainage
‐Type……………………………………………………………………………………………………..…...Sch. 40 Rigid PVC
Perforated
‐Size……………………………………………………………………………………………………………………………..….4‐inch
‐Sock……………………………………………………………………………………………………….……MnDOT SPEC 3733
‐Location…...All Low Points in both directions; at 350 foot intervals, and Project Specific Design
‐Length……………………………Minimum 100‐foot runs; 100 feet in both directions from low points
‐Clean Outs…………………………………………………………………………Every 150 feet and at all dead ends
Curb and Gutter
‐Material, All Purposes………………………………………………………………………………………..………Concrete
‐Strength, Minimum Requirements…………………….……………………………………….…….…….…3,900 PSI
‐Type: New Developments, Single Family Residential……………………………………….…Surmountable
‐Type: Multifamily, Commercial, Collector Roads, Medians, Reconstruction………………….….B618
Utility Conduit
‐Type……………………………………………………………………………………….………………….….PVC Schedule 40
‐Location/Depth……………..Perpendicular to Street and minimum 1‐foot below Street Subgrade
Entrances/Driveways
‐Maximum Driveway Width at Right‐of‐way…………………………………..……Varies by Zoning District
Formatted: Font: 5 pt
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 3 of 9
‐Bituminous Driveway Minimum Thickness, Section…………………………………..…………Match Street
‐Residential Concrete Driveway Minimum Thickness……………………………………………………6‐inches
‐Commercial Concrete Driveway Minimum Thickness………………………………………..………..8‐inches
Signing
‐Design Standards………………………………………………………………………………………………………MMUTCD
‐Sheathing Type……………………………………………………………………….…Type IX Diamond Grade
(DG3)High Intensity Diamond Grade DG3
‐ S i g n P o s t s, green powdered painted galvanized
metal…..……………………..……………..….…………………………………..Pre‐Punched 14 ga. Square Tube3.0 LBS/ft
RIGHT‐OF‐WAY AND BOULEVARD LAYOUT
Right of Way Widths
‐Local Residential Street Minimum Width………………………………………..……………………………60‐feet
‐Cul‐de‐sacs……………….…………………………………………………………………………………..…..60‐foot radius
‐Collector Street Minimum Width………………………….…..…………………..…...Varies (as determined
by City80 feet Minimum))
Boulevard, Local Residential Street
‐
Width……………………………………………………………………………………………………...……………..…..…..……16‐feet
(15‐feet at cul‐de‐sacs)
‐Slope, Typical and Maximum………………………………………………………………..………………..4% and 4:1
‐Topsoil Minimum……………………………………………………………………………………..…………………….6‐inch
‐Turf Treatment…………………………………………………………………………………………………..……..Lawn Sod
‐Tree Location without Sidewalk or Trail……………………….................................8‐feet back of curb
‐Tree Location with Sidewalk or Trail…………………………………………….…..…………5‐feet back of curb
‐Street Light Location……………………………………………………………………………………5‐feet back of curb
‐ S t r e e t L i g h t T y p e/Pole…………………………………..……………………………………………….15‐foot California
Acorn w/Aluminum Pole (All Black)
‐Hydrant Location………………………………………..………………………………………….……..5‐feet back of
curb
Sidewalks
‐Collector Street…………………………….……………………………..………………...……Required on both sides
‐Local Residential Street…………………………….……………………………...……….……Required on one side
‐Cul‐de‐sac Street…………….………….……………………………….………………Required for trail connection
‐Width……………………………………………………………………………………………………...…………………..…6‐feet
‐Sidewalk Maximum Longitudinal Grade……………………………………………………………………………….6%
‐Pavement Section…………..…………………………………..………5‐inch Concrete; 4‐inch Select Granular
Trails
‐Locations…………………………………..……………………………..……....…Per City trail plan and as directed
‐Width, Local Trail……………….………………………………………………………………..………………………...8‐feet
Formatted: Indent: First line: 0.25", Tab stops: Not at 2.62"
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 4 of 9
‐Pavement Section, Local Trail…………..………………2.25‐inch Bituminous; 8‐inch minimum Class 5
‐Maximum Longitudinal Grade……………………………………………………………………………………………..8%
Berm Construction in Boulevard
‐Maximum Side Slope with Maintenance Requirements…………………………………………………......3:1
‐Maximum Side Slope with Natural Vegetation………………........................................................2:1
SANITARY SEWER
Force Main
‐Material……………………………………………………………………………………………………….……...PVC or HDPE
‐PVC, 2‐inch–24‐inch……….……………………………………………………………………………………… C900/C905
‐HDPE Class, 1‐inch…………………………………………………………………….…………………………………….S DR 9
‐HDPE Class, 2‐inch–24‐inch……………………………………………………….……………………………..…..SDR 11
‐Minimum Cover……………………………………………………………………………………………………..………7.58‐
Feet
‐Location of main in Street……………………………………………………………………….……….Project Specific
‐Tracer Wire………………………………………………………………...812 AWG solid, PRO‐TRACE HDD‐CCS
PE45
‐Air Relief Valve and Manhole Locations………………………………………………….………….All High Points
‐Clean Outs………………………………………………………………………………………………………….All Low Points
Gravity main
‐Material……………………………………………………………………………………………………………….…………….PVC
‐Minimum Diameter……………………………………………………………………………………..………………...8‐inch
‐Class, up to 20‐feet in depth………………………………………………………………………..………………..SDR 35
‐Class, 20‐25 feet in depth……………………………………………………………………………………….……..SDR 26
‐Class and Material, over 25 feet in depth………………………………………………………...Project Specific
‐Minimum cover over pipe……………………………………………………………………………………………5.5‐feet
‐Maximum depth of pipe……………………………………………………………………………………………….30‐feet
‐Slope……………………………………………………………………………………………..………..Ten States Standards
‐Tracer Wire…………………………………………………………………12 AWG solid, PRO‐TRACE HF‐CCS PE45
‐Location of main in Street………………………………………………………………………………………..Centerline
Sanitary Sewer Manholes
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 5 of 9
‐Type…………………………………………………………………………………………………………......Precast Concrete
‐Maximum inlet/outlet elevation difference…………………………………………………………………...2‐feet
‐Minimum depth of Manhole…………………………………………………………………….…………………….6‐feet
‐Type of Casting………………………………………………………………………………………………….……….R‐1642‐B
‐Joints and Assembly……………………………………………………………………………….………..Per City Details
‐Location………………………………………………………………………………………………..……….Street Centerline
‐Maximum Spacing………………………………………………………………………………………………..…….400‐feet
‐Flow Line Match Required……………………………………………………………………………………8/10ths Rule
‐Drop Across All Manholes Required………………………………………………………………………..……0.1‐feet
‐Connections to Existing Manholes………………………………………………………….….Core Drill with Boot
‐Outside drop minimum…………………………………………………………………………………………………..2‐feet
‐Outside drop Material….………………………………………………………………………………………..Ductile Iron
Service Pipe
‐Material…………………………………………………………………………………………………………….……………….PVC
‐Minimum Diameter…………………………………………………………………………………………………….....4‐inch
‐Class………………………………………………………………………………………………………………………….…..SCH 40
‐Tracer Wire…………………………………………………………………12 AWG solid, PRO‐TRACE HF‐CCS PE45
‐Drive‐In Magnesium Grounding Anode Rod……………........Copperhead Part # ANO‐1005 (1.5lb)
WATERMAIN
Water Service Pressures
‐Individual Booster Pumps required………………………………………………..……….development specific
Main Pipe
‐Material……………………………………………………………………………………………………….……………………..DIP
‐Class……………………………………………………………………………………………………………….………………CL. 52
‐Minimum Diameter – Mainline………..………………………………………………………….………………...8‐inch
‐Minimum Diameter – As allowed by City EngineerUnlooped Cul‐de‐
sac…..…………..………………….………………………..……….8‐inch
‐Minimum Diameter – Hydrant Lead……………………..……………………..………………………..……….6‐inch
‐Minimum Cover…….…………………………………………………………………………………………..…………7½‐feet
‐Maximum Length of Dead Ends…………………………………………………………………..………………61,000‐
feet ‐Air Release measures…………………………………………………………………………….…………….MH, Hydrant
‐Tracer Wire………………………………………………………………..…..128 AWG solid, PRO‐TRACE HF‐CCS
PE45
‐Location of main in Street……………….……………………………………………………………..….No rth or West
Hydrants
‐Type……………………………………………………………………………………….……...…...Waterous Pacer WB‐67
‐Depth of Bury…………………………...………………………………………………………………………………….8½‐feet
‐Maximum Coverage Radius, Residential..……….……………………………………………………..……500‐feet
‐Maximum Coverage Radius, Commercial…………….………………………………………………..……300‐feet
‐Gate valve on Hydrant
leads…………………………………………………………………………..…………………..Yes‐at Tee
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 6 of 9
‐Hydrant Nozzel………..…………………………………………………4‐inch Storz with Pentagon Nut end cap
‐Temporary dead end lines…………………………………….………Hydrant required (no air bleed valves)
Valves
‐Resilient Seat Gate Valve, for 12‐inch pipe & smaller…..……American Flow Control 2500 Series
‐Butterfly Valve, for pipe over 12‐inch………………………………….…..…………………Mueller Lineseal III
‐Valve Box………………………………………………...........................................................Tyler G‐Box6860
‐Maximum area isolated by valving………………………………………………………………………….20 services
‐Maximum distance between valves on Trunk Mains……………………………………………….….800‐feet
Service Pipe
‐Service Material…………………………………………………………………………….……………….Type “K” copper
‐Corporation Stop…………………………..…………………………………………….……….A.Y. McDonald 74701B
‐Curb Stop ………….…………………………………………………………………………………..A.Y. McDonald 76104
‐Curb Box …………………………………………………………………...A.Y. McDonald 5614 w/rod & Mpls. top
STORM SEWER
Design
‐Design Frequency for Storm Sewer……………………………………………………….…...………………..10‐year
‐Minimum storm sewer design velocity…………………………………………………………….………….……3‐fps
‐Maximum storm sewer design velocity…………………………………………………………………………..15‐fps
‐Maximum storm sewer outlet velocity…………….………………………………………………………….……5‐fps
‐Minimum Outfall Pipe Slope……………….Verify positive grade at completion (no reverse grade)
Main Pipe
‐Storm Sewer Pipe Material…………………………………………………………………………………………….….RCP
‐Minimum Cover Depth…………………………………………………………………………………………………...3‐feet
‐Minimum Pipe Diameter, Main…………………………………………………………………………………....15‐inch
‐Minimum Catch Basin Lead…………………………………………………………………………………………..12‐inch
‐Location of main in Street……………………………………………………………..…………………….South or East
Culvert pipe
‐Culvert Material, urban road or crossing public road……….…………………………………………….….RCP
‐Culvert Material, rural road private driveway….……………….……………………………………………...CMP
‐Minimum Culvert Size……………………………………………………………………………………………….....15‐inch
‐Apron and Trash Guard Required……………………………………………………………………………….……...Yes
Manholes
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 7 of 9
‐Type………………………………………………………………………………………………………………Precast Concrete
‐Sump Depth and
Location…………………..…....………………………………………………………………………………....4‐feet, located at
street prior to discharge pointN/A
‐Minimum Structure Depth………………………………………………………………………………………........4‐feet
‐Casting…………..……………………………………………………………………………………………………..…..R‐1642‐B
‐Minimum Adjustment Rings…………………………………………………………………………………….…………….2
‐Maximum Adjustment Rings…………………………………………………………………………………..……...1‐foot
Catch Basins
‐Type………………………………………………………………………………………………………..…….Precast Concrete
‐Minimum Structure Depth…………………………..…………………………………………….……………........4‐feet
‐Maximum run to Catch Basin………………………………………………………………….…………………..350‐feet
‐Casting, Curb & Gutter, B Style Curb………………….………………………………………………………..R‐3067V
‐Casting, Area Drain……………………………………………………………………..…………………………………R‐4342
STORMWATER MANAGEMENT AND STORMWATER BMPs
Note: Stormwater facilities shall be in accordance with the Requirements listed herein; in accordance with the
Requirements of the applicable watershed district; and in accordance with the Minnesota Pollution Control
Agency NPDES Construction Storm Water Permit. In addition, all “Recommended” and “Highly Recommended”
provisions of the Minnesota Stormwater Manual should be considered requirements by the City of Lake Elmo
unless specifically approved otherwise by the City Engineer.
Site Design
‐Facility locations….……………………………………………………………….……………….Outlots deeded to City
‐Location and Size………………..……………………………………………………………..……above 100‐year HWL
‐Building Lowest Floor above 100‐year HWL…………………………………………………………………….2‐feet
‐Building Lowest Opening above EOF…………………………………………………………………………….…1‐foot
‐Minimum access road width (located in Outlot)…………………………………………………………...20‐feet
‐Maximum grade for maintenance access roads………………………………………………………………...10%
‐Setback from building foundations……………………………………………………………………………….35‐feet
‐Flood Protection…….……………Overland Emergency Overflows Required (No landlocked basins)
Stormwater Ponds (Detention Basins)
‐Design Frequency (DF)………………………….…2, 10, and 100‐year, and 100‐year 10‐day snowmelt
‐Minimum Basin Depth to HWL.……………………………………………………………………………………….3‐feet
‐Maximum Pond Depth to HWL…………………….………………………………………………………..……..10‐feet
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 8 of 9
‐Average Permanent Pool Depth………………………………..........................................4‐feet to 6‐feet
‐Permanent Pool Length‐to‐Width Ratio………………………………………………………….....3:1 or greater
‐Maintenance Bench Maximum side slope, first ten feet above Permanent Pool….………..….10:1
‐Aquatic Bench Maximum side slope, first ten feet into Permanent Pool….…………………...….10:1
‐Maximum side slope, beyond first ten feet…………….…………………………………..………………………3:1
‐Pretreatment Sediment Forebay……………………………………………….………………….…Required 10%
Pond Area
‐Required freeboard……………………………………………………………………………………..2‐feet above HWL
‐Pond Liner…………………………………………………………………………Clay lined per VBWD specifications
Drainage Swales
‐Maximum side slopes on Swales (maximum slopes allowed only when necessary)……….......3:1
‐Maximum side slopes on Right‐of‐Way Swales……………………………………………………….…………..4:1
‐Minimum longitudinal Swale grade…………………………………………………………………………..…........2%
‐Minimum Swale depth within Right‐of‐Way…………………………………………………..………...18‐inches
‐Minimum Bottom Width………………………………………………………………………………………………...4‐feet
Infiltration Facilities (Bioretention Areas and Rain Gardens)
‐Inlet control from Streets………….…Use Neenah R‐3067‐V casting on Catch Basin (no curb cuts)
‐Maintenance Agreement for public right‐of‐way..……………………………………………………..Required
‐Maintenance Access Easement..………………………………………………………………………………..Required
‐Minimum distance from septic system or drainfield………………………………………………….....35‐feet
‐Minimum distance from public or private well.…………………………..…………………………….....50‐feet
‐Maximum Site Slope……………………………………………………………………………………………………………5%
‐Minimum depth to Bedrock………………………………………………………………………………………..….5‐feet
‐Minimum depth to Seasonally High Water Table…………………………………………………………...5‐feet
‐Located in “hotspot” drainage shed (i.e. gas stations)……………………………………………..Prohibited
‐Located in Hydrologic Soil Group D Soils……………………………………..…………………………..Prohibited
‐Underdrain, Group C Soils (filtration)………………..…………………….…………………………………Required
‐Soil infiltration rates……………………………………………………….*By Field Testing at Facility Location
‐Minimum In‐situ Permeability……….………………………………………………………………..1‐inch per hour
‐Maximum side slope….……………………………………………………………………………………………………….4:1
‐Maximum drain dry time………………………………………….………………………………………………..48 hours
‐Soil medium……………………………………….…………………….…MnDOT 3877 E Rooting Topsoil Borrow
‐SeedingPlantings………………………………………….Seed per ....................MnDOT 3876
Specifications with Type 33‐261
‐Plantings………………………………………Planted in conformance with City approved landscape plan
………………………………………………………………….Seed to be enhanced with 1 plug per 4 Square
Feet
…………………………….….Infiltration areas 10,000 sqft or greater requires 3 grass mixes for variety
………………………Native Shrubs to be planted in conformance with City approved landscape plan
* Soil borings are required to verify infiltration rates. Borings must be taken to a depth of 520
feet below proposed infiltration basin elevation.
Minimum 2 borings per facility up to 5,000 SF. of infiltration area.
Minimum 3 borings per facility up to 10,000 SF. of infiltration area.
CITY OF LAKE ELMO, MN | DESIGN STANDARDS MANUAL REVISION DATE: MARCH 2017FEBRUARY 2015
PAGE 9 of 9
Additional boring required for every additional 2,500 SF. of infiltration area.
Other Stormwater BMPs: The City of Lake Elmo has adopted the following additional BMPs and Low
Impact Development practices for the City and promotes their use in accordance with these
Engineering Design Standards and the applicable City Code.
Open Space Developments in applicable Zoning Districts.
Narrow Streets through minimized street width standards.
Stormwater Reuse.
Infiltration/filtration Practices.
Filtration Facilities.
Vegetated Swales (Ribbon Curbs and Curbless Streets in applicable Zoning Districts).
Temporary Erosion and Sedimentation Control using Engineering Standards Manual.
Stormwater Site Design.
‐Conservation of open spaces to protect a site’s natural areas.
‐Impervious lot coverage credits for Stormwater BMPs.
‐Use of Pervious Pavements.
‐Adoption of Minimal Impact Design Standards (MIDS) to mimic predevelopment
hydrology.
‐Reproduce predevelopment hydrology.
‐Incorporation of Landscaping and use of Native Vegetation.
DETAIL PLATE NUMBERS AND PLAN NOTES
Pipe Installation 101,103,105
Watermain 200A,201,203,204,206,207A,207B,208,210,211
Sanitary Sewer 300A,301,302,303,305,306,311,313,314,315
Storm Sewer 400A,402,404,405,406,407,408,409,410,411,
411,412,416,417,419,420,421
Pavements, Curbs, Walks
500A,501,502,504,505,506,507A,507B,507C,508,509
507D,507E,508,509,510,511,512,513,514
Erosion Control 600A,600B,600C,600D,601,603,604,605,606
Miscellaneous 700A,706,712,713
Typical Sections and Right‐of‐Way 801,804,805,806,807A,807B
Signing/Pavement Markings/Lighting Landscaping
900A,901A,901B,902A,902B,,903A,903B,904
208
STANDARD DRAWING NO.
LAKE ELMO
CITY OF LAKE ELMO
MARCH 2017
514
STANDARD DRAWING NO.
LAKE ELMO
CITY OF LAKE ELMO
MARCH 2017
902
STANDARD DRAWING NO.
LAKE ELMO
CITY OF LAKE ELMO
MARCH 2017
903
STANDARD DRAWING NO.
LAKE ELMO
CITY OF LAKE ELMO
MARCH 2017