HomeMy WebLinkAbout04-22-74 PZMVILLAGE OF LAKE ELMO
PLANNING AND ZONING COMMISSION
MINUTES OF THE MEETING APRIL 22, 1974
Meeting called to order at 7:40 p.m.
Members present: Chairman Wm. Lundquist, R. breher, B. Folz, D. Lyons,
J. Sovereign, T. Williams.
Minutes of April 9th corrected as follows:
Page 1, paragraph 5, should read "...questions about subdividing
the N 1/2 of SE 1/4 of Section 3...."
Minutes approved as corrected.
HEARING: LAKE ELMO HEIGHTS PLAT. Neither the people to do the
platting nor any of the neighbors -- except Mrs. Folz were in
attendance.
NOTE: FOR ALL FUTURE PLATTING HEARINGS, PZC RECOMMENDS THAT ALL
ABUTTING PROPERTY OWNERS BE NOTIFIED IN WRITING.
The following observations and recommendations were made:
1. At a previous meeting, PZC had agreed that there should
be on -site precolation tests.
2. An attempt should be made to ascertain that every lot is
buildable but not required that every lot have percolation
tests.
3. Should be a proposed re -subdivision in the event that
public sewer is provided.
4. The 7% park land for this 150 acres should be in the
NW corner.
5. There was a proposed 20' trailway system under the power
line.
6. They should propose the size and location to hold the run-
off from a 100-year flood so that it will not over-
load the existing drainage structure under the highway.
7. They should propose the size of the dike necessary for
that capacity.
8. Detailed grading plan should be provided.
9. Lots 4 and 5 of Block 2 should be combined into one lot
and the pond retained in its natural condition.
10. Lots 4 and 5 of Block 3 should be combined and the pond
retained in its natural condition.
11. Storm drainage ditches and roadway system should be detailed.
For further consideration Bill Schwab's comments are attached.
-2-
Village Engineer has stated that the culvert presently under Trunk
Highway 6 is adequate for this subdivision and will be analyzed
and upgraded at the time County Road 6 is upgraded, if it is deemed
necessary.
Motion by B. Folz, seconded by T. Williams, to recommend preliminary
approval of this plat subject to the conditions listed above, with
the stipulation that if unsatisfactory soil conditions exist, that
this plan be re -submitted and discussed in detail with the
Planning Commission. If percolation tests are satisfactory, the
grading plan, diking plan, and percolation tests are to be submitted to
the Village Engineer for recommendations and approval. Motion
passed unanimously.
HEARING: FRED H. RICHERT, 3870 Jamaca Ave., regarding Special Use
Permit to mine gravel. List attached of those in attendance.
The following problems were cited in regard to the gravel operation:
1. Roads will require calcium chloride treatment.
2. Operating noise.
3. Dust
4. General appearance of the operation.
5. Safety hazards.
6. Loss in value of surrounding homes.
7. Length of operation (years).
No action was taken because of the late hour. However, PZC requests
that a copy of the Barton proposal as contained in their letter of
April 9th and a copy of the mining ordinance be mailed to all those
people attending the hearing.
it was stated that the property owner to the north of Richert's is
interested in joining in the gravel operation; however, this must
be a separate consideration.
HEARING: DONALD OLSON, 2932 Legion Avenue No., regarding Special Use
Permit to install fence on above property. Mr. and Mrs. Olson were
the only attendees. They wish to install a 42" fence; present
ordinance limits fence to 30". Question was raised for reasoning
behind the establishment of the 30" requirement.
Motion by B. Folz, seconded by J. Sovereign, to recommend that a
Special Use Permit be granted for Mr. and Mrs. Olson to install
a 42" chain link fence across the front of their yard on
Government Lot 1 - S24T29R21 being the S 87' on the N 414' of
E 180'.
Howard Springborn, Martin Zabell, appeared regarding recreational
area on Mr. Springborn's property. Mr. Springborn was advised to
apply for a Special Use Permit. A hearing will be set for the
-3-
next PZC meeting.
by mail.
DAVID MORGAN presented the Park Study Committee's
requesting acquisition of 279 acres of parkland.
T. Williams, seconded by J. Sovereign, to endorse
Committee's recommendation dated April 19, 1974.
unanimously.
Meeting adjourned at 12:10 a.m.
All abutting property owners are to be notified
recommendation
Motion by
the Park Study
Motion passed
Respectfully submitted,
Sandy Phernetton
Rec. Secretary
iate,414.;1
e Z--/g/g• p krur
771)6.0-e,D/ADwiZE
)),p j_J-t.u4-)
--)/L1444 ,e3e
/-+tele-e"2:-.(1444.
8 ( iiv,✓) L /i.. f d of 11/
Y2 zq 39't st- ti
2( 33 5 T ti
ya 9'6'`'s 7 ,
/7,
-733 J1144/1e/1- /VE, N0
BPoP 3 t-L-ZIP,
g'g7 iv 3
126 Ofhl
&48 c4L-4_
S. 7 Z. -C1,"11--i;f4P,&
11
/l
it
L1���1z
avia-e-f /-Avt44..
JCS t L -\+rE)127\rJ o. M:•J..
3 �� 45V
g27 SI
ffif 3r
-7-k sTN
3 Y 7/
a q it -A/
Qeo s.e .� ,eitsSe. 'm o14✓A 44 4 !1%J 44.46,e
").
FWashington
CountyPLANNING DEPARTMENT
r
WILLIAM A. SCHWAB
COUNTY PLANNING COORDINATOR
WASHINGTON COUNTY OFFICE BUILDING • STILLWATER, MINNESOTA 55082
TO: CITY OF LAKE ELMO COUNCIL AND PLANNING COMMISSION
SUBJECT: REVIEW OF PROPOSED SUBDIVISION - LAKE ELMO HEIGHTS
DATE: APRIL 1, 1974
A copy of the Lake Elmo Heights proposed subdivision was sent to me for re-
view in accordance with the standard subdivision procedures. We have prepared
a detailed staff review of the major problems which confront this subdivision.
The staff report is divided into three parts:
1.) A survey of the soil conditions and the potential for single family
septic systems on these soils. (In accordance with the Minnesota
Department of Health Regulations.)
2.) A review of the road grades and general grading plans.
3,) A review of the lot sizes and the potential for re -subdivisions of
these same Tots if, and when, a central sewer system is built in
the area.
As is the case in most subdivisions without central sewer, the promary concern
is the soil suitability for single family septic systems. We are all well aware
of the consequences of inadequately planned septic systems. If such systems
fail, they endanger the health and wealth of the community. Inadequate and
failing septic systems have lead to the introduction of very expensive, indepen-
dent central sewer processing plants many years ahead of schedule in areas like
Lino Lakes, Prior Lake, and Lakeville. Proper planning of lot sizes, sod and
septic system location, and review of construction standards can help forestall
and/or eliminate the need for these expensive processing systems.
Before approving the preliminary plat I would recommend that the Planning Com-
mission request further information on the soil depths and capacity for septic
systems. In addition, the staff report recommends requesting grading and re -
subdivision plans from the developer.
WHERE MINNESOTA WAS BORN
City of Lake Elmo Council and Planning • Commission
April 1, 1974
Paget
We would assist the developer, if so desired, in making specific recommendations
as to location and type of soil information he should provide. We could then
review this information and have specific recommendations for you to consider.
We would also be available to review the grading or re -subdivision plan. I hope
this review and the recommendations will be of some benefit to the City Council
and the Planning Commission. If I can be of any further assistance please do
not hesitate to contact me.
Sincerely
William A Schwab
County Planning Coordinator
WAS/mlp
)1"
93Was hi n gt on
4 County
WILLIAM A. SCHWAB
COUNT ✓ PLANNING COORDINATOR
PLANNING DEPARTMENT
WASHINGTON COUNTY OFFICE BUILDING • STILLWATER, MINNESOTA 55082
TO: CITY OF LAKE ELMO COUNCIL AND PLANNING COMMISSION
SUBJECT: STAFF REVIEW OF PROPOSED SUBDIVISION -
LAKE ELMO HEIGHTS
DATE: APRIL 1, 1974
A copy of the proposed subdivision plat has been forwarded to us by your City
Clerk. It has been reviewed in a manner similar to Ruth's First Addition which
we did a few weeks ago. We evaluated soil conditions for on -site sewer dis-
posal using the Minnesota State Standards as our guide. We also reviewed the
street grading plan, keeping in mind the driveway and housing elevations at the
setback lines and the existing slopes on the land. Finally, we looked at the
lot layout and the subdivision, Plat 1, as only a portion of the entire 145 acre
parcel.
Soil Conditions:
The majority of the site is covered by a shallow silt loam with some pockets of
fine sandy loam. The slopes are moderate to severe and the water table may
fluctuate seasonally to within 2 - 3 feet of the surface. Most importantly, the
percolation rates for single family septic systems in these soils are very poor
when based on the U S Department of Agriculture Soil Conservation Service.
If municipal sewer were available, there would be no problem in approving the
site for single family residences, but since the central sewer system may be at
least 8 to 10 years away, we do not feel single family housing can be constructed
on all of these proposed lots.
Because of the "patchiness" of the soils we would recommend that the Planning
Commission request soil borings and percolation tests on all lots prior to approval
of the preliminary plat. This information would help determine the number and
size of lots that could legitimately be placed on the acreage. Upon receipt of
the information, the developer may want to resubmit a preliminary plat which
would better align his lots with the areas suitable for subdivision.
WHERE MINNESOTA WAS BORN
City. of Lake Elmo Council and Planning Commission
April 1, 1974
Page 2
Street and Grading Plan
Generally the slopes on the site range from 8 to 13N and are much more severe
in isolated areas; up to 2070 along a number of north facing slopes. At present,
with the preliminary plan, we cannot ascertain the lot grading.
Assuming little lot grading would be done several areas of concern exits:
1. Ironwood Tr N: (Plat 1, Blk 1, Lot 9) has a road cut of 9 feet with an
extremely steep slope into the lot. The driveway on such a lot may
become a hazzard for both entering and parking.
2. Inter Avenue N: (Plat 1, Blk 1, Lot 2, 7, 8) has a road cut of 8 feet,
again with a steep slope into the lot.
3. Ironwood Trail N: (Plat 1, Blk 2, Lot 2, 3) has a road cut of 10 - 12
feet on the south side which again would produce steep driveways
and lots.
4. 27th Street N: (Plat 1, Blk 2, Lot 12, 13, 14) have lot grades below
the road grade which may present overland drainage problems for
both house and septic system.
5. Ideal Avenue N: Depending upon the esthetic value to the Commission,
perhaps the tree line along the fence row and directly in line with the
placement of Ideal Avenue N should be maintained.
Severe cut and fill areas can have an effect on more than steep slopes. Place
ment of septic systems should be kept away from these disturbed areas. Footings
for housing units should not be placed on the uncompacted fill. Altered drainage
patterns and erosion of these disturbed soils can cause tremendous soil and
structural drainages. The City Council and Planning Commission in reviewing
these items should request the developer to prepare: 1) preliminary grading plans
or profiles indicating the quantity and location of the cut and fill and 2) provide
a preliminary soil erosion control plan for the existing fields, ponds and stream.
Re -Subdivisions
Because of the nature of the soils in this area and the cost of municipal sewer,
some thought should be given to providing a re -subdivision plan along with the
preliminary plat. This re -subdivision plan would give lot owners with large (over
160') frontage the option to subdivide their lots when a municipal sewer is in-
stalled. Most subdivided Tots would be approximately 2 acre in size. The tre-
mendous cost of sewer installation could then be shared by two lot owners instead
of one.
City of Lake Elmo Council and Planning Commission
April 1, 1974
Page 3
Within Plat 1, 39 lots have been proposed. Eleven of these lots (287.) have
sufficient frontage along the dedicated public road to legitimately qualify for re -
subdivision when central sewer is installed. Most of the Tots vary in frontage
from 125 to 160 feet. The normal minimum side yard setbact is 10 feet.
These lots could not be subdivided for a typical rambler of 72 - 80 feet in
length including a double garage.
In reviewing the preliminary Plat 1:
a.) Blk 1; Lots 1, 2, 3, 8, and 13 have enough frontage along the
residential road.
b.) Blk 2; Lots 6, 7, 8, and 9 have enough frontage along the
residential road.
c.) Blk 3; Lot 6 has enough frontage along the residential road.
d.) Blk 4; Lot 1 has enough frontage along the residential road.
Conclusions
The City Council and Planning Commission should require additional information
from the developer. On -site soil borings and septic system percolation tests
should be completed and documented for the City prior to approval of the pre-
liminary plat. In addition a preliminary grading plan showing cut, fill and ero-
sion control provisions should be requested from the developer. Finally, for the
protection of the lot owner and the developer, a realignment of the plat and an
additional re -subdivision plan, consistent with soils and grades, should be sub-
mitted.