Laserfiche WebLink
ATTACHMENT A <br /> 411 <br /> DESIGN STANDARDS <br /> GARBAGE ENCLOSURES <br /> The following standards will serve as the official design <br /> specifications for the construction of all garbage dumpster <br /> enclosures within the City of Mounds View as required by Chapter <br /> 104 of the Municipal Code: <br /> LOCATION: <br /> 1 . All enclosures shall be placed so as to be completely and <br /> fully located on the subjact property. <br /> 2 . No enclosure shall be located less than 30 '-0 " from. -the <br /> front property line nor less than 1'0" from all sides or <br /> rear property lines . <br /> 3 . All enclosures shall. be constructed on an impervious <br /> surface (i.e. , concrete, asphalt pad) . <br /> 4 . Any enclosure attached to a building must meet all <br /> applicable building and fire codes . <br /> DIMENSIONS : • <br /> 1 . All enclosures shall be constructed of a size sufficient <br /> enough to provide for a minimum of 2 '-0 " of clearance on <br /> all sides of the garbage dumpster. <br /> 2 . All enclosures shall be a minimum of 6 '-0 " in height. <br /> 3 . All enclosures shall be equipped with a latching gate or <br /> doors . <br /> APPEARANCE : <br /> 1. All enclosures shall be constructed of materials providing • <br /> for sufficient screening with a minimum of_ gaps and open <br /> areas . <br /> 2 . All enclosures shall be maintained in a state of good repair <br /> at ail times. _ <br /> 3 . No chain link fencing will be acceptable. <br />