My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Agenda Packets - 1991/08/12
MoundsView
>
Commissions
>
City Council
>
Agenda Packets
>
1990-1999
>
1991
>
Agenda Packets - 1991/08/12
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2025 4:49:31 PM
Creation date
7/18/2018 6:33:46 AM
Metadata
Fields
Template:
MV Commission Documents
Commission Name
City Council
Commission Doc Type
Agenda Packets
MEETINGDATE
8/12/1991
Supplemental fields
City Council Document Type
City Council Packets
Date
8/12/1991
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
I <br /> PROJECT APPROACH <br /> I <br /> SCOPE OF SERVICES <br /> This project involves providing engineering services to the City of Mounds View for an <br /> analysis of the water storage needs for the City. The study will use the existing <br /> 111 calibrated Ky Pipe computer model for evaluating the possibilities of: <br /> A. Elimination of tower no. 2 from the system. <br /> 11 B. Replacement of tower no. 2 with a smaller tower. <br /> C. Elimination of tower no. 2 from the system and replacement of tower no. 1 <br /> I (and sizing this tower). <br /> D. Elimination of tower no. 1 (and/or tower no. 2) and adding a new tower in <br /> the northeast part of the City (and sizing this new tower). <br /> The City of Mounds View has a calibrated Ky Pipe computer model which has peak <br /> demands at all the nodes. This model will be used for the analysis. <br /> 1111 <br /> During the study a complete understanding of the operation of the water system will be <br /> required to interpret the computer output. Consequently, several meetings will be held <br /> U during the course of the study with the operating and engineering staff of the City. At <br /> the conclusion of the study a report will be written which will include recommendations <br /> for a course of action regarding the water storage needs, location and sizes. <br /> Mounds View Water System <br /> The City of Mounds View is presently served with 6 wells, 2 elevated storage <br /> reservoirs and one 2 million gallon ground storage reservoir, and a distribution system <br /> consisting of 4-inch watermains and larger. Well no. 4 presently is the only well that <br /> does not have treatment. This well is used infrequently and is a candidate for <br /> replacement/abandonment. The City is presently constructing a water treatment plant <br /> near the City Hall which will treat water from well nos. 1, 2 and 3. <br /> Tower- no. 1 presently- has --severe structuraldamageand is in need of extensive <br /> structural repairs. <br /> Tower no. 2, located in the southeast corner of the city, is also in need of minor <br /> structural repairs. Tower no. 2 has consistently maintained higher water elevation than <br /> tower no. 1 because of lower demands in the vicinity of the tower. Both towers have <br /> lead based paint which is very expensive to remove and repaint. The study now being <br /> II proposed will evaluate the adequacy of storage provided by towers 1 and 2 and the <br /> -need for retaining, increasing and/or abandoning the-existing elevated storage,-and-the <br /> need for a new storage facility in the northeast corner of the city. <br /> I <br /> I <br /> PCE <br />
The URL can be used to link to this page
Your browser does not support the video tag.