My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Agenda Packets - 1990/05/21
MoundsView
>
Commissions
>
City Council
>
Agenda Packets
>
1990-1999
>
1990
>
Agenda Packets - 1990/05/21
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2025 4:48:02 PM
Creation date
7/25/2018 6:15:31 AM
Metadata
Fields
Template:
MV Commission Documents
Commission Name
City Council
Commission Doc Type
Agenda Packets
MEETINGDATE
5/21/1990
Supplemental fields
City Council Document Type
City Council Packets
Date
5/21/1990
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
• Staff Report March 21, 1990 <br /> Multi-Tech Systems, Inc. Page 2 <br /> Stalls <br /> Existing parking stalls 265 <br /> Parking loss due to new construction —142. <br /> Total 123 <br /> Proposed parking ramp 363 <br /> Handicapped stalls + 7 <br /> Total 370 <br /> TOTAL STALLS EXISTING AND PROPOSED 493 <br /> The new addition totals 50,884 square feet. Using the most restrictive parking <br /> requirements (office), Multi-Tech would be required to provide for the new space <br /> one parking stall per 175 square feet of floor area which equals 262 parking stalls. <br /> The existing facility is required to provide 210 parking spaces based on the known <br /> division between the warehouse and office uses. The existing facility and the new <br /> facility would require a maximum of 471 parking spaces. The proposed site plan <br /> shows 493 parking stalls which is more than required by the City parking <br /> ordinance. <br /> SETBACKS <br /> The proposed addition is situated 30 feet from the property line which is the <br /> minimum allowed per Fire Code standards based on the interior sprinkling system. <br /> LANDSCAPING <br /> City Forester Wriskey will review the landscaping plan. To date, a landscaping <br /> plan has not been submitted. It is expected that something would be available for <br /> your meeting Wednesday evening for your review. <br /> GRADING. DRAINAGE AND UTILITIES <br /> Please refer to City Engineer Ric Minetor's memorandum dated March 15, 1990, <br /> which is attached to this report. The Engineer's report also raises the unresolved <br /> • issue regarding the possible driveway to the Waste property. The applicant will be <br /> prepared to address the issue at the meeting. <br />
The URL can be used to link to this page
Your browser does not support the video tag.