Laserfiche WebLink
Planning Commission <br /> Planning Case No.464-96: 2375 Highway 10 • <br /> October 9, 1996 <br /> Page 12 <br /> (8) Adequate utilities,access roads,drainage and necessary facilities have been or will be <br /> provided. <br /> The proposal will use a previously developed site which is served by existing utilities and <br /> roads. There is an existing drainage ditch along Highway 10. Staff will be referring the <br /> proposal to MnDOT and the Rice Creek Watershed District to determine if there are any <br /> concerns with the site drainage-continuing as it has in the past. <br /> Staff Recommendation: Our preliminary response to the proposal is very favorable. <br /> There are two key issues which need to be addressed which arise from the adoption of <br /> new criteria for conditional use permits for auto sales in 1996. These are the amount of <br /> landscaping required and the comparison between the enclosed building square footage <br /> and square footage in outdoor storage of inventory. We would be concerned if the new <br /> criteria meant that the proposal could not go forward. The criteria may have been meant <br /> for smaller sites, and represent a hardship on a site of this size. Also it is our impression <br /> that the ratio between square footage in building and in outdoor storage was to prevent <br /> the use of small kiosk type buildings for sales offices. The Saturn dealership is proposing <br /> a substantial building of 11,600 square feet, housing both the sales office and service bays. <br /> • <br /> Staff would recommend that the following additional information from the applicant or <br /> referral agencies is needed prior to the next Planning Commission meeting. <br /> 1. Planning application and fees <br /> 2. Proof of ownership and letter from owner of Citgo parcel giving permission for <br /> application to be filed on this parcel <br /> 3. Photometrics for light standards <br /> 4. Comments from the City Engineer and Rice Creek Watershed District (staff to do <br /> referral) <br /> 5. Provide copy of map dated 2/19/92 showing test drive routes. <br /> Staff would recommend that the following requirements or changes in the plans be made: <br /> 1. Bring forward contingencies from Resolution 4195 and 4611, if appropriate. <br /> 2. Same lighting standards be used on both sites. <br /> 3. Eliminate the request for second monument sign, unless variance in number of <br /> pylon signs allowed is approved. <br /> 4. Show three handicapped parking spaces, and convert two inventory spaces to <br /> customer spaces, to comply with parking requirements. <br /> 5. Add note to plans that customer and employee parking will be clearly marked and <br /> kept free of use for inventory. • <br />