Laserfiche WebLink
L <br /> i <br /> Planning Commission Report <br /> Bridges Technology Park Phase II <br /> Planning Case 514-98 <br /> March 27, 1998 <br /> Page 2 <br /> Discussion: <br /> Previously: <br /> This request was discussed at the Planning commission's last meeting on April 1, 1998. <br /> According to the site plan dated 3/6/98, all of the dimensional requirements for this development <br /> would be met with the exception of the parking requirements, which will be discussed further <br /> below. One of the primary issues that was raised at the last meeting concerned how close the <br /> paved area was to the delineated wetland. It was requested that the distance between the wetland <br /> and pavement be increased to a minimum of ten feet. The revised plan(date-stamped 4/8/98) <br /> submitted by the applicant shows a setback of ten feet while maintaining a minimum 26-foot <br /> drive-aisle behind the building, as recommended by the Fire Marshal. <br /> Drainage. Wetland Considerations and Wetland Alteration Permit: <br /> As discussed at the last meeting, because work is being done within 100 feet of the wetland, the <br /> applicant will need to have a wetland buffer permit approved by the City. From the revised site <br /> plans, the new parking area and drive-aisles will be a minimum of ten feet from the delineated <br /> edge of the wetland. The revised site plan shows the 100-foot wetland buffer, the edge of the <br /> easement area, and statistics regarding the area of the buffer and the percent of which is covered • <br /> in pervious and impervious surface. <br /> Parking: <br /> The applicant has provided a master site plan for both lots 2 and 3 showing the parking for the <br /> existing and proposed buildings. Altogether, a total of 200 spaces would be required for both <br /> buildings, with a total of only 162 stalls being provided. The remaining 38 stalls are indicated as <br /> "proof of parking" on the master site plan. The proof of parking can be allowed one of two ways. <br /> For the ncighboring ZEP manufacturing, the pro: - .•. - _ • • •. - • • • • - • - Sig <br /> and warehouse parking ratios on the condition that the spaces be constructed if needed in the <br /> future. The Code, in Section 1121.14, requires that a conditional use permit be obtained for any <br /> reduction in parking space requirements. Obviously, a variance to the parking ratios would be the <br /> more expedient solution, if that choice is still an option considering the what the Code requires. <br /> If a variance to the parking requirements were considered, the following amended ratios would <br /> closely match with the number of stalls being provided: <br /> Office: 3 spaces plus 1 per 200 square feet of floor area=3 + 84 = 87 <br /> Warehouse: 8 spaces plus 1 per 750 square feet of floor area= 8 + 65 = <br /> .160 • <br /> The difference between the number of stalls provided (162) and the number required (200)would <br /> need to be shown as future parking(38). <br />