Current Mounds View City Code for Solar Energy and Wind Generator Systems <br /> <br /> <br />1103.04: SOLAR ENERGY SYSTEMS AND STRUCTURES: <br /> <br />Subd. 1. Qualification: To qualify as a solar energy system, the system must be permanently located for not <br />less than ninety (90) days in any calendar year beginning with the first calendar year after completion of <br />construction. Passive solar energy systems are included but not to the extent that they fulfill only <br />recreational uses. <br /> <br />Subd. 2. Conditional Use: Solar energy systems and solar structures shall be permitted by conditional use in <br />all districts; provided, that the system and/or structure is in compliance with minimum lot requirements <br />and setbacks and meets the requirements of subdivision 1125.01(3) of this Title, but in no event shall a <br />conditional use permit be granted for a solar energy system or structure which, when installed, would <br />prevent abutting properties from being developed in conformance with all applicable codes or <br />regulations. <br /> <br />Subd. 3. Casting of Shadows: No owner, occupier or person in control of property shall allow vegetation or <br />structures to be placed so as to cast a shadow on a solar energy system which is greater than the shadow <br />cast by a hypothetical wall ten feet (10') high located along the boundary of said property between the <br />hours of nine thirty o'clock (9:30) A.M. and two thirty o'clock (2:30) P.M. Central Standard Time on <br />December 21; provided, however, this standard shall not apply to vegetation or structures which cast a <br />shadow upon the solar energy system at the time of installation of said solar energy system or to <br />vegetation existing at the time of installation of said solar energy system. <br /> <br />Subd. 4. Violation Declared Nuisance: Violation of this standard shall constitute a private nuisance, and any <br />owner or occupant whose solar energy system is shaded because of such violation so that performance <br />of the system is impaired may have in tort for the damages sustained thereby and may have such <br />nuisance abated. (1988 Code §40.04) <br /> <br />1103.05: WIND GENERATOR SYSTEMS: <br /> <br />Subd. 1. Height: The height of a wind generator system shall not exceed thirty feet (30') above the height of <br />the principal structure. <br /> <br />Subd. 2. Anchorage: Anchorage of the system's tower shall not be located within ten feet (10') of the <br />property line. <br /> <br />Subd. 3. Protection from Climbing: The tower or support for the system shall be of climbproof design or <br />protected by fencing. <br /> <br />Subd. 4. Compliance with Other Laws: Location and height must be in accordance with all other governing <br />jurisdictions and laws as they exist and are amended. <br /> <br />Subd. 5. Noise: The system shall have a silent operation and be subject to the requirements of Chapter 604, <br />Nuisances, of this Code. <br /> <br />Subd. 6. Plans and Specifications: All systems will require plans, specifications and a site plan approved by a <br />registered engineer or architect if deemed necessary by the City. (1988 Code §40.04) <br /> <br />