Laserfiche WebLink
907.04 <br />Subd. 3. Construction Specifications: <br />907.04 <br />a. Materials: All pipe shall be cast iron soil pipe conforming to A.S.T.M. <br />Standard Specification A-74-80, vitrified glazed clay sewer pipe conforming to A.S.T.M. <br />Standard Specification C-700-78A, asbestos cement sewer pipe, conforming to A.S.T.M. <br />Standard Specifications C-428-80 or PVC plastic sewer pipe, conforming to A.S.T.M. Standard <br />Specification D-3033 or D-3034. All pipe used shall be a four inch (4") diameter pipe; except, <br />that when vitrified glazed clay sewer pipe is used, it shall be at least six inch (6") diameter pipe. <br />b. State Plumbing Code Incorporated by Reference: There is hereby adopted and <br />incorporated by reference, the "State Plumbing Code"', as amended. All sanitary sewer <br />construction and material shall be in accordance with the provisions of said Code. <br />C. Joints and Connections: <br />(1) Cast Iron Soil Pipe: Hub and spigot shall have a compression type gasket, or hubless <br />joints will be made with fittings conforming to C.I.S.P.I. Standard 301-72. <br />(2) Vitrified Glazed Clay Sewer Pipe: Compression joints for vitrified glazed clay pipe <br />will conform to A.S.T.M. Standard Specification C425-77, relating to rubber ring -sealing <br />elements, rubber for other than ring -sealing elements, plastic components or metallic <br />components. <br />(3) Asbestos Cement Sewer Pipe: Joints for asbestos cement sewer pipe shall be made by <br />use of the manufacturer's joint, which shall include an asbestos cement sleeve, together <br />with rubber rings which shall form a tight and flexible joint. <br />d. Grades: Unless otherwise authorized, all house sewers shall have a grade of not less than <br />one -eighth inch per foot (1/8" = 1'). A grade of one-fourth inch per foot (1/4" = 1') should be <br />used wherever practical. The person to whom the permit is issued shall check grades before <br />construction proceeds. Wherever possible, the connecting sewer shall join the building at an <br />elevation which is below the basement floor of such building. <br />e. Alignment: No connecting sewer shall contain bends or a combination of bends which, at <br />any point, shall be greater than forty five degrees (45°), except where cleanouts are constructed at <br />such points and in a manner as directed by the Building Inspector. No connecting sewer shall be <br />laid parallel to any bearing wall or footing unless farther than three feet (3') from any such <br />bearing wall or footing. No connecting sewer shall be laid within twenty feet (20') of any <br />existing well, except in a manner specifically approved by the Building Inspector. <br />' See Section 1004.01 of this Code. <br />City of Mounds View <br />