G. Doors serving toilet rooms or stalls shall be <br /> capable of being unlocked from either side. <br /> • Subp. 7. Stair tread nosing. Riser sn.all be slanted to <br /> meet the tread nosing edge, or where the tread extends beyond <br /> vertical risers, nosing shall be rounded and not project beyond <br /> the riser more than one inch. <br /> Subp. 8. Aisles and lanes. Where pedestrian aisles or <br /> lanes are defined with directional barriers, rails, benches, <br /> merchandise, tables, seats, or fences, at least one shall have <br /> not less than 31 inches clear width for use of the handicapped <br /> and shall be identified for such use. <br /> MS s 16B.59 to 16B.73 <br /> 9 SR 1557; 11 SR 1405 <br /> 1340.0400 SANITATION FACILITIES. <br /> Subpart 1. Definitions. Sanitation facilities may include <br /> toilets (water closets) , urinals, lavatories, bathtubs, showers, <br /> sinks, and similar plumbing fixtures. <br /> Subp. 2. Requirement for multiple dwellings. Group R <br /> Division 1 occupancies having more than seven dwelling units or <br /> guest rooms in a single building must be provided with <br /> sanitation facilities in accordance with part 1340.9100. In a <br /> multiple-building development, the dwelling units or guest rooms <br /> / containing sanitation facilities must not be located solely in <br /> one building. <br /> Subp. 3. Requirement for other buildings. In other <br /> buildings regulated by parts 1340.0200 to 1340.0900 and <br /> 1340.9000 to 1340.9900, at least one required toilet room for <br /> each sex or a separate facility usable by either sex must have <br /> not less than one toilet and lavatory complying with this part <br /> and part 1340.0500, and where urinals are provided, not less <br /> • <br /> than one urinal complying with this part and part 1340.0500. In <br /> buildings having more than one toilet room for each sex, not <br /> less than two required toilet rooms for each sex or two separate <br /> facilities usable by either sex must comply with this part and <br /> part 1340.0500. Toilet rooms havingplumbing P 9 fixtures required <br /> by this part and part 1340.0500 must be identified for use by <br /> the handicapped. Buildings having a posted room directory must <br /> list the location of those toilet rooms in the directory. <br /> Subp. 4. Location other than Group R-1 apartment <br /> occupancies. In buildings with an elevator or ramp, the <br /> sanitation facilities may be located at any level served by <br /> elevator or ramp. Where sanitation facilities are required in <br /> buildings without an elevator or ramp, the sanitation facilities <br /> shall be conveniently located at the required entrance level, <br /> accessible without leaving or reentering the building. <br /> MS s 16B.59 to 16B.73 <br /> 9 SR 1557; 11 SR 1405 <br /> 1340.0500 SIZES AND CLEARANCES FOR SANITATION FACILITIES. <br /> Subpart 1. Toilets. Toilet rooms or compartments shall <br /> have not less than 36 inches--clear space at the front__of the <br /> toilet and not less than 36 inches clear width between walls, <br /> free of door swing and other obstructions. Toilet seats shall <br /> be not less than 17 inches nor more than 20 inches above the <br /> floor. Grab bars shall be-provided at both sides or one side <br /> and rear of the toilet. Such grab bars shall be securely <br /> fastened to support a load of not less than 250 pounds. They <br /> 168 <br /> 111 <br />