My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2023-01-18 PC Packet
MoundsView
>
Commissions
>
Planning & Zoning Commission
>
Agenda Packets
>
2020-2029
>
2023
>
2023-01-18 PC Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2024 11:59:33 AM
Creation date
10/5/2023 2:56:09 PM
Metadata
Fields
Template:
MV Planning Commission
DOC TYPE
PACKETS
Rectangle
ID:
1
Creator:
METRO-INET\JENNIFER.NELSON
Created:
10/5/2023 2:56 PM
Modified:
10/5/2023 2:56 PM
ID:
2
Creator:
METRO-INET\JENNIFER.NELSON
Created:
10/5/2023 2:56 PM
Modified:
10/5/2023 2:56 PM
ID:
3
Creator:
METRO-INET\JENNIFER.NELSON
Created:
10/5/2023 2:56 PM
Modified:
10/5/2023 2:56 PM
ID:
4
Creator:
METRO-INET\JENNIFER.NELSON
Created:
10/5/2023 2:56 PM
Modified:
10/5/2023 2:56 PM
ID:
5
Creator:
METRO-INET\JENNIFER.NELSON
Created:
10/5/2023 2:56 PM
Modified:
10/5/2023 2:56 PM
ID:
6
Creator:
METRO-INET\JENNIFER.NELSON
Created:
10/5/2023 2:56 PM
Modified:
10/5/2023 2:56 PM
ID:
7
Creator:
METRO-INET\JENNIFER.NELSON
Created:
10/5/2023 2:56 PM
Modified:
10/5/2023 2:56 PM
ID:
8
Creator:
METRO-INET\JENNIFER.NELSON
Created:
10/5/2023 2:56 PM
Modified:
10/5/2023 2:56 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXISTING BUILDING <br />I EXISTING BUILDING / MB <br />LMI <br />w <br />IO <br />GM <br />449 ., �. LL— <br />#46 s4 <br />#27 #31 11 TYP <br />11 TYP <br />Y <br />0 F#26 <br />4116 <br />g #33 #45 #55 (}' <br />#25 • <br />X I �#3 #34 #54 -' — <br />2 •!:•,. <br />#23 9 #61 v <br />0 #43,`F <br />#24 #56 ..• 7 <br />#210 <br />#62 <br />#19 #63 #57 <br />#20 #18 #35 � #42 #59 <br />0 #37 — <br />LLJ <br />p #38 #36 CAZEBD O I <br />X 8 4 #41 #64 <br />O#40 r/ #58 <br />OE OE OE <br />OF 8 11 TYP <br />X I #17 � <br />gb <br />4 X 4 <br />11 0 <br />TYP X X—� 69" <br />X w0 X X '`F #39 10 <br />#16 F <br />X O X 1 X O O #75 #67 #66 <br />X NNEL <br />X I �� rx X �O <br />#13 X X ��S170" <br />J#12 EXISTING BUILDING O <br />)( #1 1 X •� #3 cnBncE0 O w01 <br />m <br />#10 <br />I IT415 <br />X <br />X <br />X ' )(—A '71'X' <br />I I 11 TYP <br />_I O <br />—r—>>— <br />LIJ <br />12"CIP <br />#5 <br />#7 #1 <br />60" WATERMAIN <br />#6 � #4 <br />60" WATERMAIN <br />15"RCP <br />P:\Projects\Projects - 2022\12226046 - Mounds View Residential\C. Design\Drawing Files\12226046 C100.dwg <br />v <br />%N M H 0 <br />M=910.0 <br />V=890.9 <br />W <br />i <br />V <br />Z <br />O <br />J <br />rs rf ;y,•`�:i:�:.:�'�: ;. 11 TYP I <br />..#74.rl •. <br />t. .M• ...... .... ..... ......... <br />.. <br />�• r '� l ^`i t 1 � <br />• 4' L— <br />.�.�A,r, •.•C,,�h � � � � � a !.� 't,•: •l jtpl •*w�. '� '�' j% •� ..it <br />CB <br />. i ! . t <br />12 <br />':' , '•'•' #81 RIM=910.8 <br />•" , INV=907.1 <br />.� : •• .NCB <br />�; :t•%„' 1 ':', I I I g I 60" WATERMAIN IM=911.8 U <br />INV=906.6 <br />•t •7•�r , �•s;r ��� 15"RCP <br />U <br />� � <br />60" WATERMAIN <br />STS MH <br />COUNTY RD. I RIM=912.6 <br />INV-905.55 <br />S> >> >>— <br />> ' <br />SAN MH <br />RIM=911.8 <br />INV=887.7 <br />SAN H <br />RIM=912.3 <br />INV=889.3 N <br />INV=? E-N/ <br />OE <br />SYMBOL LEGEND <br />,, <br />REMOVE AND DISPOSE OF EXISTING <br />•'. •'•'•'. •'•'•'. •'•'• <br />BITUMINOUS PAVEMENT SECTION <br />�' , ;,, :' •; <br />REMOVE AND DISPOSE OF EXISTING <br />CONCRETE PAVEMENT SECTION <br />t., t • •'• <br />REMOVE AND DISPOSE OF EXISTING GRAVEL <br />KEY NOTES <br />O1 REMOVE AND DISPOSE OF EXISTING BUILDING AND ANY <br />FOOTINGS ASSOCCIATED WITH BUILDING. <br />O2 SAWCUT, REMOVE, AND DISPOSE OF EXISTING CONCRETE CURB <br />AND GUTTER. <br />0 REMOVE AND DISPOSE OF EXISTING GRAVEL. <br />® REMOVE AND DISPOSE OF EXISTING FENCE FABRIC, POSTS, <br />AND FOOTINGS. <br />O5 REMOVE AND DISPOSE OF EXISTING ELECTRIC METER. <br />COORDINATE WITH ELECTRICAL. <br />© REMOVE AND DISPOSE OF EXISTING POWER POLE, GUY WIRES <br />AND FOOTINGS. COORDINATE WITH ELECTRICAL. <br />l`7 REMOVE AND DISPOSE OF EXISTING LIGHT POLE AND <br />FOOTING/BASE. COORDINATE WITH ELECTRICAL. <br />z <br />® REMOVE AND DISPOSE OF EXISTING OVERHEAD POWER LINES. <br />O <br />COORDINATE WITH ELECTRICAL. <br />_ <br />Og REMOVE AND DISPOSE OF EXISTING GAS METER. COORDINATE <br />U <br />WITH GAS COMPANY. <br />10 REMOVE AND DISPOSE OF EXISTING GAS LINE. COORDINATE <br />n/ <br />WITH GAS COMPANY. <br />11 REMOVE AND DISPOSE OF EXISTING TREE, STUMP, AND ROOTS <br />(74 TOTAL). <br />z <br />12 PROTECT "RAW WATER CONDUIT". <br />O <br />U <br />0. <br />O <br />DEMOLITION NOTES <br />LL <br />1. Verify all existing utility locations. <br />O <br />2. It is the responsibility of the Contractor to perform or coordinate all <br />necessary utility demolitions and relocations from existing utility locations <br />z <br />to all onsite amenities and buildings. These connections include, but are <br />not limited to, water, sanitary sewer, cable tv, telephone, gas, electric, <br />site lighting, etc. <br />0. <br />3. Prior to beginning work, contact Gopher State Onecall (651-454-0002) to <br />Q <br />locate utilities throughout the area under construction. The Contractor <br />z <br />shall retain the services of a private utility locator to locate the private <br />— <br />utilities. <br />5 <br />GJ <br />4. Prior to beginning work, the contractor shall submit a Traffic Control Plan <br />to the City according to the Manual on Uniform Traffic Control Devises <br />W <br />(MUTCD). <br />N <br />5. Sawcut along edges of pavements, sidewalks, and curbs to remain. <br />6. All construction shall be performed in accordance with state and local <br />standard specifications for construction. <br />7. Prior to beginning work, contact St. Paul Regional Water Services: <br />Mike Knutson at 651.775.6192 48 hours in advance. <br />NORTH <br />0 10 20 40 <br />o <br />0� <br />r <br />_ <br />LID o <br />LO <br />ai <br />z ,- <br />E <br />- (L.00 <br />o <br />Q <br />OIL <br />OY�L <br />c <br />J N <br />of <br />i <br />0M <br />a) <br />0 <br />U <br />J 0p <br />� <br />W <br />N <br />o <br />W <br />-E <br />LO <br />N <br />cy�co <br />J <br />N <br />N <br />O <br />N <br />O <br />�W <br />ZLU <br />DN <br />z <br />w�, <br />;,- <br />Q <br />L0 <br />LL <br />O <br />J <br />W <br />O <br />CC <br />— <br />UWaw <br />Y <br />G <br />Lu <br />U) <br />> <br />(.0 <br />Q <br />W <br />M <br />W <br />V ) <br />Z <br />W <br />Q <br />00. <br />U <br />Z <br />2 <br />W <br />O <br />i� <br />W <br />QUU) <br />J <br />z <br />D <br />V <br />0 <br />Z <br />O� <br />J <br />z <br />F- <br />O <br />0 <br />U <br />a <br />I hereby certify that this plan, <br />specifications or report was prepared <br />by me or under my direct supervision <br />and that I am a duly licensed <br />Professional Engineer under the laws <br />of the state of Minnesota. <br />Thomas J. Herkenhoff, P.E. <br />Date: 11.14.22 Lic. No.: 25520 <br />Rev. Date <br />Description <br />Project #: 12226046 <br />Drawn By: KBK <br />Checked By: TJH <br />Issue Date: 11.14.22 <br />Sheet Title: <br />DEMOLITION PLAN <br />Sheet: <br />
The URL can be used to link to this page
Your browser does not support the video tag.