My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Minutes - 2005/10/10
MoundsView
>
Commissions
>
City Council
>
Minutes
>
2000-2009
>
2005
>
Minutes - 2005/10/10
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/5/2025 4:20:52 PM
Creation date
3/5/2025 4:20:52 PM
Metadata
Fields
Template:
MV Commission Documents
Commission Name
City Council
Commission Doc Type
Minutes
MEETINGDATE
10/10/2005
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Mounds View City Council October 10, 2005 <br />Regular Meeting Page 5 <br />• Approving the Medtronic Development Stage PUD Plans <br />Mayor Marty opened the public heazing at 7:28 p.m. <br />Community Development Director Ericson stated they would not be discussing the wetland <br />alteration and calling of bonds at tonight's meeting. He suggested all four items 8.A.1 through <br />8.A.4. be presented as one public hearing. <br />Director Ericson stated on June 27, 2005, the Mounds View City Council and Economic <br />Development Authority authorized an agreement with Medtronic Inc. to redevelop the Bridges of <br />Mounds View golf course. The approved development was amulti-phased project with the first <br />phase encompassing 820,000 squaze feet of office space and related ancillary uses. On July 11, <br />2005, the City Council adopted Ordinance 760, an ordinance approving the transfer of land from <br />the City of Mounds View to the Mounds View EDA and then subsequently to Medtronic. On <br />August 22, 2005, the City Council approved Resolution 6581, which further authorized the sale <br />of the Bridges site to the EDA for resale to Medtronic. At the same meeting, the City Council <br />reviewed and approved the Medtronic Cardiac Rhythm Management (CRM) general concept <br />plans without conditions. <br />Director Ericson noted Opus Architects & Engineers have submitted the detailed site plans, <br />surveys and preliminary plat for this second stage of the PUD process. <br />. Director Ericson stated the PUD has been revised from the general concept plans reviewed on <br />August 22. The concept plan identified four distinct buildings in a pin-wheel orientation tied <br />together by a two-story atrium-like commons area. While there remain four distinct eight-story <br />buildings, these are now all oriented in an east-west fashion to enhance environmental <br />sustainability. The first two phases would be linked together by stacking corridors and meeting <br />rooms 60 feet wide except at the main level where the connective space is 180 feet wide. The <br />first phase would be connected to the parking ramp north of the buildings at the ground level, <br />where the daycare and service areas would be located. The parking plan remains the same, in <br />that Phase 1 would include athree-story structure ramp to the north and the 900 surface stalls <br />near the building entrance. <br />Director Ericson stated the buildings are set back a minimum of 40-feet from the periphery lot <br />line, which is consistent with the minimum requirements within the PUD. The buildings will be <br />no closer than 80 feet to Highway 10 and 60 feet to Coral Sea Street and 82nd Lane NE. The <br />Phase 1 parking ramp will be set back 100 feet from Coral Sea Street to preserve an existing <br />stand of mature Scarlet Oak trees. The parking lot/ramp along 82 Lane NE will be set back 40 <br />feet. <br />He indicated the building will be constructed of precast concrete wall panels with horizontal and <br />vertical reveals. The base of the buildings will have a decorative or specialty stone base. The <br />rooftop utilities will be hidden from view by metal panel screens to match the color scheme of <br />• the building. These rooftop mechanical aprons and elevator penthouses will be inwazdly set back <br />from the edge of the building by as much as thirty feet to reduce their visibility. The facade will <br />
The URL can be used to link to this page
Your browser does not support the video tag.