HomeMy WebLinkAboutResolution 7553RESOLUTION 7553 CITY OF MOUNDS VIEW COUNTY OF RAMSEY STATE OF MINNESOTA RESOLUTION APPROVING THE CITY POLICY FOR NON-REQUIRED RESIDENTIAL FIRE SPRINKLER PERMITS WHEREAS, the City of Mounds View recognizes the importance, value and life saving abilities of fire sprinkler systems; and WHEREAS, Mounds View wants to encourage property owners to install fire sprinkler systems whenever possible; and WHEREAS, the City Council discussed a City staff proposal to revise the City policies about the permits and permit fees for those who install voluntarily such systems at the January 4, 2010, City Council Work Session; and WHEREAS, it was the consensus of the City Council at the January 2010 Work Session to amend the City policies about the permit fees for the voluntary installation of such systems to waive the City fees for the permits for the installation of such systems. NOW, THEREFORE BE IT RESOLVED that the Mounds View City Council does hereby approve the attached City policy about Non-required fire sprinkler system permits. Adopted this 11th day of January, 2010. e , ATTEST: James Ericson, Clerk-Administrator (seal) MOUNDS V~~V City of Mounds View Fire Inspections 2401 Highway 10 Mounds View, 55112 Business Phone 763-717-4024 Fax 763-784-3462 Non-required fire sprinkler system permits for single-family homes. Definition: From the Minnesota State Residential Building Code Single-family: Any building that contains one dwelling unit used, intended, or designed to be built, used, rented, leased, let or hired out to be occupied, or occupied for living purposes. Application and Submittal A completed and signed permit application must be included with. the submittal otherwise the submittal will be returned to the contractor. 2. Submit a minimum of two (2) sets of complete plans, specifications, and hydraulic calculations for review to Fire Inspections. 3. The minimum drawing size scale is 1/8t" inch =one foot. Details shall be a minimum 1/4t" inch =one foot or large enough to be legible if not to scale. 4. All submittals shall be in compliance with the requirements of the 2007 Minnesota State Fire Code and the 2002 NFPA 13D. Adequate, concise, and sufficient information shall be clearly indicated on the plans to review the system design. 5. The newest edition of NFPA 13D may be used if it is clearly designated on the plans and calculations, and must be utilized in its entirety. 6. Any material/installation deviation from approved plans will require permission from the Fire Department. All changes shall be followed up in writing on company letterhead. Issuance of Permit After the plans are reviewed and approved, the City will issue the permit. You will receive one (1) copy of the approved plans to be placed on the job site. 2. No work shall be started without a permit and an approved set of plans on the job site. The Inspection card shall be posted in a conspicuous place on the job site. Fees There will be no fee for a permit issued under this policy. This policy allows for one (1) plan review and up to three (3) site inspections. If additional plan review is required to approve the plans and more than three (3) site inspections are made to ensure code compliance, a fee of $47.00 per hour will be charged to the contractor. All fees, if applicable, must be received prior to scheduling the final inspection. Inspection and Testing Call Community Development at 763-717-4020, if no answer; leave voicemail. A 24- hour notification is required so your date and time can best be accommodated. Same day inspections are generally not available. 1. Hydrostatic tests. The fire sprinkler system components must remain visible and/or be accessible without the use of ladders or lifts during a hydrostatic test. A. When a fire department connection is not provided, the system shall be hydrostatically tested for leakage at normal system operating pressure. B. When a fire department connection is provided, the system shall be hydrostatically tested at 200 psi for 2 hours with no loss of pressure or visible leakage. C. Piping shall remain accessible and exposed during hydrostatic testing. 2. Final inspection and testing of the system. A. Where water flow alarms are provided, inspector's test connections shall be installed at locations that allow flow testing of water supplies, connections and alarm mechanisms. General Requirements 1. Dry fire sprinkler systems are not allowed to be designed or installed under this policy. 2. A minimum of a ten (10) psi safety margin is required. 3. The installing contractor shall provide to the owner/ occupant instructions on inspecting, testing and maintaining the system Mailing Address: City of Mounds View 2401 Highway 10 Mounds View, MN 55112 Office Phone: 763-717-4000 FAX: 763-717-4019