HomeMy WebLinkAboutGroveland Park Shelter email
-----Original Message-----
From: Steve Dazenski
Sent: Tuesday, February 22, 2005 7:52 AM
To: Jim Hess
Subject: FW: Mounds View - Groveland Park Shelter
-----Original Message-----
From: Richard L. Gray [mailto:gray.rl@tkda.com]
Sent: Friday, February 18, 2005 4:06 PM
To: Steve Dazenski
Cc: Kathryn E. Poore-Larson
Subject: Mounds View - Groveland Park Shelter
Steve,
We have plotted the survey for Groveland Park and are working on
placement of the building on the site. I have attached a drawing showing
a proposed location and orientation for the new park shelter (Scale:
1"=30'). The existing park shelter is also shown on the drawing for
reference. We tried to save as many trees as possible while also placing
the building so that it would relate appropriately to the rest of the
park. Key elements of this layout include the following:
1. One 12" ash will have to be removed. All other trees can be
saved.
2. The floor plan is a mirror image of the concept architectural
layout that we sent you before. This layout places the mechanical room
of the new building approximately where the existing water service is
located. This mirror image floor plan also places the exterior doors to
the rest rooms towards other park activity areas versus away from them.
Can you confirm from City record drawings that this is the correct water
service location? We were making an educated guess based on the
locations of the hydrant, valve and drinking fountain identified on the
survey. Can you also verify from your record drawings the location of
the existing sanitary service? The end in the existing building is based
on survey notes, however the alignment towards the sewer line in the
street was our best guess based on gaps between the existing trees.
3. Placement of the new building in approximately the same location
as the existing building takes advantage of a slightly elevated piece of
ground so that drainage can easily be directed away from the building.
It also allows use of the existing water and sanitary service lines with
minimal additional work.
4. The floor elevation of the new building is proposed to be
approximately one foot below the elevation of the existing building.
This will allow easier access to the building but will still be high
enough to provide good drainage out from the building. We may propose
insulation over the existing sanitary line right by the building for
frost protection.
Please review the proposed building location, orientation, and mirror
image floor plan. If this is acceptable, we will proceed with
construction documents. Please let me know if you want us to proceed
with this layout or if you want to make any changes. Thanks,
Rich
The attached files are transmitted for your convenience and are the sole
property of TKDA. By accepting delivery the recipient agrees to
indemnify and hold TKDA harmless from any liability arising from the use
of this data. By acceptance of this data, the user agrees not to
transmit this data or provide access to it or any part of it to another
party. This electronic data is subject to change and updates are the
responsibility of the recipient. TKDA is not responsible for updating
the files or for compatibility with recipient's hardware and/or
software. Please check these files for virus contamination prior to use.
Richard L. Gray, ASLA
Landscape Architect
TKDA
651/292-4420 (phone)
651/292-0083 (fax)
gray.rl@tkda.com
444 Cedar Street, Suite 1500
St. Paul, MN 55101-2140
on survey notes, however the alignment towards the sewer line in the
street was our best guess based on gaps between the existing trees.
3. Placement of the new building in approximately the same location
as the existing building takes advantage of a slightly elevated piece of
ground so that drainage can easily be directed away from the building.
It also allows use of the existing water and sanitary service lines with
minimal additional work.
4. The floor elevation of the new building is proposed to be
approximately one foot below the elevation of the existing building.
This will allow easier access to the building but will still be high
enough to provide good drainage out from the building. We may propose
insulation over the existing sanitary line right by the building for
frost protection.
Please review the proposed building location, orientation, and mirror
image floor plan. If this is acceptable, we will proceed with
construction documents. Please let me know if you want us to proceed
with this layout or if you want to make any changes. Thanks,
Rich
The attached files are transmitted for your convenience and are the sole
property of TKDA. By accepting delivery the recipient agrees to
indemnify and hold TKDA harmless from any liability arising from the use
of this data. By acceptance of this data, the user agrees not to
transmit this data or provide access to it or any part of it to another
party. This electronic data is subject to change and updates are the
responsibility of the recipient. TKDA is not responsible for updating
the files or for compatibility with recipient's hardware and/or
software. Please check these files for virus contamination prior to use.
Richard L. Gray, ASLA
Landscape Architect
TKDA
651/292-4420 (phone)
651/292-0083 (fax)
gray.rl@tkda.com
444 Cedar Street, Suite 1500
St. Paul, MN 55101-2140
2