Laserfiche WebLink
City of Saint Anthony Housing Maintenance Ordinance • <br /> Draft Number 5 -- September 2, 1992 <br /> Page Number 10 <br /> 1 (b) Dwelling Unit Door Locks. Every door that is designed to provide ingress or <br /> 2 egress for a dwelling unit within a multiple family building shall be equipped <br /> 3 with an approved lock that has a dead-locking bolt that cannot be retracted <br /> 4 by end pressure, however, that such door shall be openable from the inside <br /> 5 without the use of a key or any special knowledge or effect. <br /> 6 <br /> 7 SUMP PUMP WELLS. At the point of sale of a dwelling unit, sump pumps and drain tile <br /> 8 must be inspected visually and/or by smoking to ensure that they are not connected in any <br /> 9 manner to the sanitary sewer system. If the Compliance Officer determines the sump pump <br /> 10 or drain tile is connected to the sanitary sewer system, the situation must be corrected before <br /> 11 the dwelling unit is considered in compliance to be sold. <br /> 12 <br /> 13 MANUAL AND AUTOMATIC CHECK VALVES. At the point of sale of a dwelling unit, <br /> 14 a homes sanitary sewer line to the main street line must be inspected for manual and <br /> 15 automatic check valves. If the Compliance Officer determines that both manual and <br /> 16 automatic check valves are necessary to prevent backflow, the situation must be corrected <br /> 17 before the dwelling unit is considered in compliance to be sold. <br /> 18 <br /> 19 MULTIPLE DWELLING OUTDOOR WATER SERVICE METERING. Each multiple • <br /> 20 dwelling shall have a meter measuring the amount of water used for such outdoor activities <br /> 21 as lawn maintenance, gardening, parking lot cleaning. <br /> 22 <br /> 23 FIRE SAFETY EQUIPMENT. Every dwelling and dwelling unit shall have necessary fire <br /> 24 safety equipment, such as fire extinguishers and smoke alarms and other equipment as <br /> 25 required by State Fire Code. <br /> 26 <br /> 27 MINIMUM STANDARDS FOR LIGHT AND VENTILATION. No person shall occupy <br /> 28 as owner, occupant or let to another for occupancy any dwelling or dwelling unit, for the <br /> 29 purpose of living therein, which does not comply with the following requirements: <br /> 30 <br /> 31 HABITABLE ROOM VENTILATION. Except where there is supplied some other device <br /> 32 affording adequate ventilation and approved by the Compliance Official, every habitable <br /> 33 room shall have at least one window facing directly outdoors which can be opened easily. <br /> 34 The minimum total of openable window area in every habitable room shall be in compliance <br /> 35 with minimum standards in the Minnesota Uniform Building Code. <br /> 36 <br /> 37 NONHABITABLE ROOM VENTILATION. - Every bathroom and water closet <br /> 38 compartment, and every laundry and utility room shall contain at least 50% of the ventilation <br /> 39 requirement for habitable rooms contained in Section #####,except that no windows shall <br /> 40 be required if such rooms are equipped with a ventilation system which is approved by the <br /> 41 Compliance Official. • <br /> 42 <br />