TYPICAL CROSS SECTION OIL LOCAL STREET <br /> Source: U.S. Department of Transportation, FHA Highway/Utility Guide, June 199-1. <br /> 3 <br /> x a <br /> 10' thin. 12'-16' (E) 12' - 16'(E) 10' min. <br /> Utility Easement . Utility Easement <br /> (Front and/or (Front and/or <br /> rear yard) rear yard) <br /> 6' 6• 6'min.(D) <br /> 3' <br /> 'min.(D) <br /> 1.5'Zone(C) Pavement Width 1.5'Zone(C)- _15� 4' l' <br /> �--� 26' -53' Back To Back <br /> o 0 S' S' <br /> S' 5' t a4 I I 6' <br /> I g I I <br /> T ra f c S ' ° (F)Tcic/S rn <br /> (F,G) (F)Tele/ ----- - — —__ CATV 3' <br /> M (F.C) <br /> Storm sewer±4' — Gas 3' Elec.4 <br /> Elec. CATV 3' I ^— Footing main- — ——— — — — u Fo ►n8 stn O O <br /> 3'i4' i 3' _ —_ _ _ _I II Scrvtce Line * Service Line 3' 4' 3' <br /> Min. ----- <br /> Gas 3'(Alt.)--� I I Storm Sewer(Alt.) Watermain 5' <br /> I I Strut Light Cablc/Elcctric Note:Alternatives used when <br /> 5.1 Al , utility easements do not exist. <br /> Service ire r �crvi cZinc <br /> c <br /> 1 — Sanitary Sewer 8' <br /> GENERAL NOTES: <br /> (A)ROW width varies(see Design Standards). eliminate the coupling between the anchoring too and valve. For maintenance purposes, <br /> (B)Unless otherwise approved,the following apply to utilities in the ROW: the min.distance between centerline of valve box to face of hydrant must be 15'. Stop <br /> 1. Utilities arc normally buried. When overhead utilities arc allowed and cross the boxes should be located V from ROW tine in area without sidewalks. <br /> roadway,the minimum vertical clearance for main cable is 20 foci and service cable (E)Puking Area Widths. Varies by roadway classification(see Design Standards). <br /> is 18 feet. Jurisdiction may require wider parking area for future widening. <br /> 2. Telephone,cable TV and water are on cast and south side of road (F)Utility Easements-Telephone,Fiber Optics,Cable T.V.,Electric and Gas Lines: <br /> 3. Gas,electric and sanitary sewer are on west and north side of road Located in front or rear yard easements on local and minor collector routes. For major <br /> (C)Storm Sewers: Normal clearance for intake is 1.5'from back of curb. When collectors and arterials,they may be placed in ROW upon approval of the Jurisdiction. <br /> combination manholes and intakes are used,clearance increases to 5'. Normally,telephone and cable T.V.lines arc placed in tear yards;fiber optics,electrical <br /> (D)Watermains,Valves and Hydrants. Normal watermain location is 4'back of curb. For lines and gas lines in front yards. Placement of electric lines in rear yards depends <br />on <br /> combination manholes and intakes,this distance wiU increase to a minimum of 6'. For transformer locations and requires approval of the electric company and Jurisdiction. <br /> local streets and minor collectors with limited ROW,use a 6'900 anchoring elbow o (G)Electric Recommended bury for electric cable is 4'. Minimum bury for electric fines is <br /> per the National Electric Safety Code. <br /> Note: 1 m=3.28 ft <br />