Laserfiche WebLink
1 1+18 8" x 4" WYE 1/8 BEND <br /> UVll.sasA-EDITS CONNE EX 1T WM 54LF 4" SERVICE 4" PLUG °---°----------- <br /> 17' G & OX 959.09 z1''RCP ,0'vvc I I STUB IE 95260 <br /> 12" 9 BIND 8 52.35 1 1 ' ' 1 12-RCP <br /> 1 1 RE 957.72 1 1 1 1 1 "RCP E 955.83 11 <br /> IE 952.85 ; 1 8" % 6" TEE 1 RE 955.7 <br /> z 1 1 E 95220 <br /> 64LF-S" WM- i I E 952.72 I I <br /> 2+58 B" x WYE 1/8 BEND ' I i i 8 PWC7 BOX x :91 s II R 90.03 <br /> 56LF SERVICE 4" PLUG -;i F <br /> STUB IE 9526Q - 1 iI STUB IE 95240 s SAN.1 SEWER"-W4 RISER TO 5' <br /> _1 <br /> I 1 ' RE 957.85 1 12" 67 1/Z•BEND i 11 BEND AT ELEV. 948.00 4" SERVICE ° <br /> 36' 1 R 954.,, 10" x 6" TEE �'5 1 STUB IE. 950.00 4" PLUG <br /> 952.00 S�RCP 1 6" 11 1/8'BEND i I 12" x 6" TEE I ' <br /> I I------- 10"PVC 180LF-6" WM. ' 20LF-6" WM. <br /> 12" 6" TEE, RE 959.0. 6" 90'BEND i 1 6" GV&BOX 1 76LF-12" WM. <br /> 1E 952.04 36' 1 <br /> 20LF 6" WM. 1E 952.21 24" 2-6" GV&BOXS HYDRANT FFE = 960. RE 956,.2 <br /> 6" G &BOX HYDRANT 49LF-12" WM. IE 950.87 CONNECT TO <br /> R:951.6 II EX. 10" WM <br /> HYD T 1 _ ' 1 CONNECT TO ' ii 10" GV&BOX < <br /> 1 10' x 8 ' ' 10" 22 1/2•BEND <br /> �� I. 8" x 4" WYE 1/8 BEND EX 12" WM ° <br /> 1 8" G &BOX I B IE 952.19 46LF 4" SERVICE 4" PLUG 12' GV&BOX B" " REBUILD EX. <br /> SR1L3 IE 95260 12' 90'BEND 955.6. ySANITARY MH �? <br /> us E 952 s §TO RE 957.00 <br /> STUB 954.50 - - - - 961 <br /> 1 -- ------- 1 ADD STEP a F n <br /> 211LF- 2" WM. � • 3. 1 <br /> 48LF-8° WM. 36LF-8" WM. 1' 0 " u J'AS REQUIRED <br /> I , I IE 947.09 S RE 961.]- - <br /> < „ - - ANITARr ' j ri <br /> 1Q" x TEE I BART RE 95].J6 2�A RE 956.28 ° a <br /> 19LF- " WM I P IE 929.96 - <br /> 6° G &BOX I O , [S= [� STUB]EH53.1 - - ' R 9 212 e"aANIT 1 m m <br /> HYDR T i - ------ ----0 <br /> ARr <br /> 17' 22 1/2'BEN _ FF 96210 ; FFE = 962TE -- ------ --- �\ a <br /> i 1 10" x 8° TEE w�. -_ 1 c ,E , <br /> 4 12" WM. 13LF-6" WM. / <br /> all Gv <br /> 10" x 12" TEE I HYD &BOX \ i 295LF 0" WM. iii r <br /> 12" GV&BOX _ _ 1 ' --- 11 g <br /> 10" x 8" TEE i - - ' �1u�� <br /> ♦y 'y 1 RE 957 431 ff s <br /> 8 V&BOX \ �2, x `1 1�ssz ss 11 3 W <br /> Ep, yL7 11 �{ <br /> 260 -10" 1 L I - I > °� 95809 I--1 11 ' Of S ` <br /> I \a R:r ; 165LF-6" WM. I 11 Ipsit <br /> 6" 22 1/2'BEND_ LLJ 8gj <br /> I r 1 I II Y � g <br /> 1 - - - <br /> GOLF-0, WM. 1 11 Q <br /> CONNECT TO \ 2 - _ J s S <br /> EX. 10" WM --- I SEWER O 0.4 RE 961.50 FFE = 962 a m <br /> _ _ 1 1 n <br /> 10" 22 1/2'BEND _ ------ - _ - - - - WM• IE 948.08 E�yJ <br /> 10" GV&BOX j-_ ,I. V BOX FFE--961110 SAN MH 3 119LF 8° SAN ' B 90• D - <br /> RE 961 SEWER O 0.4 <br /> 39TH AVENUE NORi-H p 6" GV OX I <br /> aF ---- p -10" WM. , YDRANT 9.w Z 960.191 <br /> T-IK RE 960. AE B54.],1I <br /> �` Q lIF 8° SAN 1 '� •j(cv e°°a <br /> I 1 <br /> SAN M 5 B" SAN SEWER O .4 1 7 - RE 959.75 <br /> 1 RE 60.1 O 1E 954.77 <br /> IE 90.20 33 B" GV$BOX i -_1`1 11---_ I <br /> 1 1 <br /> ' --------------- 129LF B" SAN T I 1 1 1 <br /> SEWER O 0.4R o +57 8" x 4" WYE 1/8 BEN I i 1 CONSTRUCT DROP M I ii <br /> dI SAN MH 4 ° - 411E 4" SERVICE 4° PLUG OX <br /> d1 RE 961.33 ° _ SAN MH 7 STUB IE 95260 g• PLUG <br /> IE 949.68 RE 96050 <br /> 1 B . 1 n <br /> i 1 u IE 951.00 SAN MH B a l <br /> 1 1921E-8" WM. a 1 <br /> 6 x 6" TEE ° tOSIF 8" SAN IE 949.50 1 G i IE 9 068"69 NOR i ii 3 <br /> 6" GV&BOX " - SEWER O 0.45 B 95260 111 <br /> -------l.�o-___-_*- ------------- 421F-6" WM i <br /> -------= - <br /> - 0 d I n <br /> --�a HYDRANT 0 - SAN MH 8 <br /> o@ 8" 22 1/2'BEND a - RE 961.50 1 x 8" REDUCER <br /> IE 951.40 1 <br /> 198LF-8" WM. P FFE = 962.10 - 1 i i i x <br /> RE, r li 1 80LF-4" SERVICE 4" PLUG j CONNECT TO EX. 10" WM <br /> z IE 2 1E= 1 STUB IE 953.00 1 1 1 0 <br /> ' > ® ' \ i I 8" x 8° TEE ' 9 <br /> ji <br /> 1 ! <br /> • <br /> - II"WA -- - - 1 > ' RE 965.8° <br /> }90 Y RCP a IE 934.]5 N.5 <br /> 7- 't13 I 296 IE 935.50 w <br /> 1 ---- ----------- <br /> 3 V 1; _ 151E-8" WM. IE 83,z" ,� m <br /> _-- _______= i' V. PLUG I 8 1 <br /> 0 <br /> ------------- <br /> STUB IE 954.50 ® ® L ''I r --- - RE 96].27 <br /> rn h 1 uoNlTamNC I 1 1a 10" x 8" REDUCERI \5= \ iE 962.54,s' <br /> n ------------ _____ __ _______ ' 2-8" 45•BENDS 1 50LF-8" I 11 <br /> % 1 ------____T_- A� 1) ®- 1 i I a 1 1 RE 967.24 <br /> 1°ti--------------------------------T a B" x 6" TEE 1 r 8" 45•BEND , ,I IE 963.] } <br /> � ' J Ilk, tr-, ii 10LF-6" WM. 2 -8" WM.� i 1 I 1 ; I } <br /> r 1 1 <br /> o i ii 6" GV&BOX i 1 , 1111 Q Z € <br /> xi 1 11 HYDRANT Z <br /> < �q°' F z <br /> ' 11 315LF-8" WM. i i i ��-- --- 1 11 i d L Z <br /> ^I u # 08LF-8" WM.a 1 S ^ -' <br /> II <br /> 1 u <br /> r3 i' - ii y - '-'- -°_uc ��� d a US ns <br /> o 1 1� II "i ' <br /> 1 1 _--___ <br /> o a p 9 RIm 8" 90'BEND ---- Q <br /> 1.1 <br /> a \ <br /> II UNDER®T. uJ a S <br /> E i ` \ II 8" 90°BEND - <br /> R 1_ 5 P O, ui aJ <br /> p.w <br /> r-w W s � <br /> z ' - - - P oN�Pa TEE <br /> NOTE Z <br /> z ` <br /> 0 <br /> N I RE 956.21 a ' i ? x 6" T r W <br /> ri 1 IE 952.58 ' t'°� 13F-6" WM. WATERMAIN 4" TO 17' SHALL BE PVC PIPE MEETING AWWA C909 Q <br /> 0 1 RE 9 21 �ar�-q � 493LF-8' WM. B" GV&BOX PRESSURE BASS 150 OR DIP WATERMAIN CLASS 52, DI FITTINGS. 3 <br /> 1E s ------ b HYDRANT PRESSURE RATING TO 350 PSI. MINIMUM COVER 7 117 g <br /> ° ---- �r-nr�- 8•• x 8" 71� <br /> -i „r 28LF-6" WM. <br /> 6' GV&BOX <br /> ST. MARIE RAILROAD SANITARY SEWER d6 DEEP SHALL BE PVC �R 3s, <br /> SAULT HYDRANT 16'-2Y DEEP PVC SDR 26 OR > 22' DEEP DIP CLASS 52 o ao so 120 r� <br /> MINNEAPOLIS & MINIMUM COVER 7 112' SCA-E IN FMr �] <br /> a <br />