Laserfiche WebLink
CONFINED SPACE CLASSIFICATION TABLE <br /> Parameters Class I Class II Class III <br /> Characteristics potential hazard-requires dangerous, but not immediately immediately dangerous to life- <br /> no modification of work life .threatening-rescue pro- rescue procedures require the <br /> procedures-standard rescue cedures require the entry--of . entry of more than one individual <br /> procedures-direct communi- no more than one individual fully equipped with life support <br /> cation with workers, from fully equipped with life sup- -`.,equipment-maintenance of__com- <br /> outside the confined space. port :equipment-Yndirect visual'-' munication req_uires. an additional <br /> o:r,._audito'ry ;comnmun c'atiori .with standby person stationed within <br /> workers. the confined space. <br /> Oxygen 19.57 - 21.47 - 16.17 to 19.49 167 or less <br /> *(148. -_,163. mm-Hg) *(122 - 147 mm Hg) *022 mm Hg) or <br /> or 21.57 to 259 greater than 259 <br /> (163 - 190 mm Hg) *090 mm Hg) <br /> Flammability 109 LFL or less 109 - 199 LFL 207 or greater -of LFL <br /> Characteristics <br /> Toxicity less than contamination greater than contamination **IDLH <br /> level referenced in 29 CFR level, referenced in 29 CFR <br /> Part 1910 Sub Part Z Part 1910 Sub Part Z - less <br /> than **IDLH <br /> *Based upon a total atmospheric pressure of 760 mm Hg (sea level) <br /> **Immediately Dangerous to Life or Health - as referenced in NIOSH Registry of Toxic <br /> and Chemical Substances, Manufacturing Chemists data sheets, industrial hygiene <br /> guides or other recognized authorities. <br />