LIGHT,VENTILATION AND OCCUPANCY LIMITATIONS <br /> than 3 feet(914 mm) between- counterfronts and appliances or the code official, endanger the life, health, safety or welfare of <br /> counterfronts..and walls. the occupants., <br /> 404.3 Minimum- ceiling heights. Habitable spaces., hallways, 404.6 Efficiency unit. Nothing in this section_shalL prohibit an <br /> corridors,, laundry,areas, bathrooms, toilet rooms and habitable- efficiency living unit from meeting the follpwing require- <br /> basement areas shall have a clear ceiling height of not less than ments: <br /> 7 feet (21.34 mm):, 1. A unit occupied by not more than,two occupants shall <br /> Exceptions: .: have a clear floor area of not less.than-220, square feet <br /> (20-4 m2) A unit occupied by three,occupants- shall have <br /> 1. In one- and two-family dwellings. beams or girders a clear,floor area of not less than 320 square feet (29.7 <br /> spaced not less than 4 feet (1219mm) on center and m2) These required areas,shall be exclusive of the areas <br /> projecting not more than,6 inches (152 mm) below the required by Items,2 and 3. <br /> required ceilipg height_. <br /> 2. The unit shall be provided with akitcheA sink, cooking <br /> 2. Basement_rooms- in one- and two-family dwellings appliance and refrigeration facilities,.-each-having a clear <br /> occupied,,exclusively for laundry; study or recreation working space of not less,than 30 inohes.(762 mm) in <br /> purposes,, having a ceiling height of not less than 6 front..Light and ventiJation confoui&g to this.code shal-L <br /> feet 8 inches (2033 mm) with not less than 6 feet 4 be provided. <br /> inches (1932 mm),of clear,height under beams, gird- <br /> ers. ducts,and similar_obstructions. 3. The unit shall-be provided with a separate, bathroom con- <br /> taining a water closet, lavatory and bathtub or shower.. <br /> 3. Rooms, occupied exclusively for sleeping, study or 4. The maximum number of occupants shall be three. <br /> similar-purposes and having a sloped ceiling over,all <br /> or part of the room, with a clear'ceiling height of at 404.7 Food preparation. All spaces to be occupied for food <br /> least 7 feet (2134, mm) over not less,than one-third of preparation purposes, shall contain suitable- space and equip- <br /> the required', a-jWmam- floor area. In calculatbV the merit to store, prepare and, serve foods in a sanitary, manner. <br /> floor area of such rooms, only those portions of the There shall be adequate facilities and services for the sanitary <br /> floor area,with,a clear ceiling height of 5 feet (1524 disposal ottood wastes and refuse, including facilities for tem- <br /> mm) or more shall be included., porary storage. <br /> 404.4 Bedroom and living room- requirements. Every bed- <br /> room and living room shall comply with the requirements of <br /> Sections,404..4.1 through 404A.5. <br /> 404:4.1 Room area Every living room shall contaim at <br /> least 120 square feet(1 11 m'-> and every bedroom shall con- <br /> taint at least 70 square feet (6.5 m2) <br /> 404A 2 Access, from bedrooms. : Bedrooms shall not con- <br /> stitute the only means of access to other bedrooms or habit- <br /> able spaces and shall not serve as the only means of egress <br /> from other habitable spaces. <br /> Exception: Units that contain fewer than two bedrooms. <br /> 404:43- Water closet accessibility. Every bedroom shall <br /> have access to at least one water closet and one lavatory <br /> without passing through another bedroom., Eveq bedroom <br /> in a dwelling unit shall have access to at least one water <br /> closet and lavatory located in the same story as the bedroom <br /> or an adjacent story:. <br /> 404.4.4 Prohibited, occupancy. Kitchens and nonhabitable <br /> spaces shall not be used for sleeping purposes. <br /> 404.A.5�Other requirements. Bedrooms shaLL comply with <br /> the applicable-provisions of this code including, but not lint, <br /> ited to, the light, ventilation, room area, ceiling height and <br /> room width, requirements of this chapter: the plumbing <br /> facilities•and water-heatig facilities.requirements of Chap- <br /> ter 5;the heatiug,facilities,and electrical receptacle- require- <br /> ments,of Chapter'6;and the smoke detector and emergency <br /> escape requirements of Chapter 7. <br /> 1 404.5 Overcrowding., . The number of persons occupying a <br /> dwelling unit shall-not create conditions that, in the opinion of <br /> 14 2006 INTERNATIONAL PROPERTY MAINTENANCE CODE® <br />