CHAPTER 7 <br /> FIRE SAFETY REQUIREMENTS <br /> SECTION 701 Fire doors and smoke barrier doors shall not be blocked or <br /> GENERAL obstructed or otherwise made inoperable. <br /> 701.1 Scope.The provisions of this chapter shall govern the <br /> minimum conditions and standards for fire safety relating to [F]SECTION 704 <br /> structures and exterior premises,including fire safety facilities FIRE PROTECTION SYSTEMS <br /> and equipment to be provided. <br /> 704.1 General.All systems,devices and equipment to detect a <br /> 701.2 Responsibility.The owner of the premises shall provide fire,actuate an alarm,or suppress or control a fire or any com- <br /> and maintain such fire safety facilities and equipment in com- bination thereof shall be maintained in an operable condition at <br /> pliance with these requirements.A person shall not occupy as all times in accordance with the International Fire Code. <br /> owner-occupant or permit another person to occupy any pre- <br /> mises that do not comply with the requirements of this chapter. 704.2 Smoke alarms.Single or multiple-station smoke alarms <br /> shall be installed and maintained in Groups R-2,R-3,R-4 and <br /> in dwellings not regulated in Group R occupancies,regardless <br /> [F]SECTION 702 of occupant load at all of the following locations: <br /> MEANS OF EGRESS 1. On the ceiling or wall outside of each separate sleeping <br /> 702.1 General.A safe,continuous and unobstructed path of area in the immediate vicinity of bedrooms. <br /> travel shall be provided from any point in a building or structure 2. In each room used for sleeping purposes. <br /> to the public way.Means of egress shall comply with the Inter- 3. In each story within a dwelling unit,including basements <br /> national Fire Code. and cellars but not including crawl spaces and uninhabit- <br /> 702.2 Aisles.The required width of aisles in accordance with able attics.In dwellings or dwelling units with split lev- <br /> the International Fire Code shall be unobstructed. els and without an intervening door between the adjacent <br /> 702.3 Locked doors.All means of egress doors shall be readily levels, a smoke alarm installed on the upper level shall <br /> o enable from the side from which egress is to be made without ffi <br /> suce for the adjacent lower level provided that the <br /> op <br /> enable <br /> the need for keys,special knowledge or effort,except where the lower level is less than one full story below the upper <br /> level. <br /> door hardware conforms to that permitted by the International <br /> Building Code. Single or multiple-station smoke alarms shall be installed in <br /> 702.4 Emergency escape openings. Required emergency other groups in accordance with the International Fire Code. <br /> escape openings shall be maintained in accordance with the 704.3 Power source.In Group R occupancies and in dwellings <br /> code in effect at the time of construction, and the following. not regulated as Group R occupancies, single-station smoke <br /> Required emergency escape and rescue openings shall be oper- alarms shall receive their primary power from the building wir- <br /> ational from the inside of the room without the use of keys or ing provided that such wiring is served from a commercial <br /> tools.Bars,grilles,grates or similar devices are permitted to be source and shall be equipped with a battery backup. Smoke <br /> placed over emergency escape and rescue openings provided alarms shall emit a signal when the batteries are low.Wiring <br /> the minimum net clear opening size complies with the code that shall be permanent and without a disconnecting switch other <br /> was in effect at the time of construction and such devices shall than as required for overcurrent protection. <br /> be releasable or removable from the inside without the use of a Exception:Smoke alarms are permitted to be solely battery <br /> key,tool or force greater than that which is required for normal operated in buildings where no construction is taking place, <br /> operation of the escape and rescue opening. buildings that are not served from a commercial power <br /> source and in existing areas of buildings undergoing alter- <br /> [F]SECTION 703 ations or repairs that do not result in the removal of interior <br /> FIRE-RESISTANCE RATINGS wall or ceiling finishes exposing the structure,unless there <br /> is an attic,crawl space or basement available which could <br /> 703.1 Fire-resistance-rated assemblies. The required fire- provide access for building wiring without the removal of <br /> resistance rating of fire-resistance-rated walls,fire stops,shaft interior finishes. <br /> enclosures,partitions and floors shall be maintained. 704.4 Interconnection.Where more than one smoke alarm is <br /> 703.2 Opening protectives. Required opening protectives required to be installed within an individual dwelling unit in <br /> shall be maintained in an operative condition. All fire and Group R-2,R-3,R-4 and in dwellings not regulated as Group R <br /> smokestop doors shall be maintained in operable condition. occupancies,the smoke alarms shall be interconnected in such <br /> 2006 INTERNATIONAL PROPERTY MAINTENANCE CODE® 19 <br />
The URL can be used to link to this page
Your browser does not support the video tag.