Laserfiche WebLink
CHAPTER <br />MECHANICAL AND ELECTRICAL REQUIREMENTS <br />SECTION 601 <br />GENERAL <br />601.1 Scope. The provisions of this chapter shall govem the <br />minimum mechanical and electrical facilities and equipment to <br />be provided. <br />601.2 Responsibility. The owner of the structure shall provide <br />and maintain mechanical and electrical facilities and equip- <br />ment in compliance with these requirements. A person shall <br />not occupy as owner - occupant or permit another person to <br />occupy any premises which does not comply with the require- <br />ments of this chapter. <br />SECTION 602 <br />HEATING FACILITIES <br />602.1 Facilities required. Heating facilities shall be provided <br />in structures as required by this section. <br />602.2 Residential occupancies. Dwellings shall be provided <br />with heating facilities capable of maintaining a room tempera- <br />ture of 68 °F (20 °C) in all habitable rooms, bathrooms and toilet <br />rooms based on the winter outdoor design temperature for the <br />locality indicated in Appendix D of the International Plumbing <br />Code. Cooling appliances shall not be used to provide space <br />heating to meet the requirements of this section. <br />Exception: In areas where the average monthly tempera- <br />ture is above 30 °F ( -1 °C), a minimum temperature of 65 °F <br />(18 °C) shall be maintained. <br />602.3 Heat supply. Every owner and operator of any building <br />who rents, leases or lets one or more dwelling units or sleeping <br />units on terms, either expressed or implied, to furnish heat to <br />the occupants thereof shall supply heat during the period from <br />[DATE] to [DATE] to maintain a temperature of not less than 68 °F <br />(20 °C) in all habitable rooms, bathrooms, and toilet rooms. <br />Exceptions: <br />1. When the outdoor temperature is below the winter <br />outdoor design temperature for the locality, mainte- <br />nance of the minimum room temperature shall not be <br />required provided that the heating system is operating <br />at its full design capacity. Ibe winter outdoor design <br />temperature for the locality shall be as indicated in <br />Appendix D of the International Plumbing Cade. <br />2. In areas where the average monthly temperature is <br />above 30 °F ( -1 °C) a minimum temperature of 65 °F <br />(18 °C) shall be maintained. <br />602.4 Occupiable work spaces. Indoor occupiable work <br />spaces shall be supplied with heat during the period from <br />[DATE] to [DATE] to maintain a temperature of not less than 65 °F <br />(18 °C) during the period the spaces are occupied. <br />Exceptions: <br />1. Processing, storage and operation areas that require <br />cooling or special temperature conditions. <br />2. Areas in which persons are primarily engaged in vig- <br />orous physical activities. <br />602.5 Room temperature measurement. The required room <br />temperatures shall be measured 3 feet (914 mm) above the <br />floor near the center of the room and 2 feet (610 mm) inward <br />from the center of each exterior wall. <br />SECTION 603 <br />MECHANICAL EQUIPMENT <br />603.1 Mechanical appliances. All mechanical appliances, <br />fireplaces, solid fuel - burning appliances, cooking appliances <br />and water heating appliances shall be properly installed and <br />maintained in a safe working condition, and shall be capable of <br />performing the intended function. <br />603.2 Removal of combustion products. All fuel - burning <br />equipment and appliances shall be connected to an approved <br />chimney or vent. <br />Exception: Fuel - burning equipment and appliances which <br />are labeled for unvented operation. <br />603.3 Clearances. All required clearances to combustible <br />materials shall be maintained. <br />603.4 Safety controls. Ali safety controls for fuel- burning <br />equipment shall be maintained in effective operation. <br />603.5 Combustion air. A supply of air for complete combus- <br />tion of the fuel and for ventilation of the space containing the <br />fuel- burning equipment shall be provided for the fuel - burning <br />equipment. <br />603.6 Energy conservation devices. Devices intended to <br />reduce fuel consumption by attachment to afuel - burning appli- <br />ance, to the fuel supply line thereto, or to the vent outlet or vent <br />piping therefrom, shall not be installed unless labeled for such <br />purpose and the installation is specifically approved. <br />SECTION 604 <br />ELECTRICAL FACILITIES <br />604.1 Facilities required. Every occupied building shall be <br />provided with an electrical system in compliance with the <br />requirements of this section and Section 605. <br />604.2 Service. The size and usage of appliances and equipment <br />shall serve as a basis for determining the need for additional <br />facilities in accordance with the ICC Electrical Code. Dwelling <br />units shall be served by a three -wire, 120/240 volt, single- <br />2006 INTERNATIONAL PROPERTY MAINTENANCE CODE" 17 <br />