Laserfiche WebLink
January 19, 2021 <br />Page 6 <br /> <br />would be approximately 135 feet to the south edge of the garages adjoining the alley, and <br />approximately 240 feet or more to the nearest wall of the residential structures themselves. <br /> <br />The applicants have proposed a grass-pave emergency drive access along the north front of the <br />building to a point adjoining the alley and the rear parking area, an employee parking lot of 20 <br />spaces. The employee lot accesses the shared drive, and would utilize the Kenzie Terrace access <br />point to the south. No traffic is able to use the alley, with exception of emergency vehicle use <br />which would need to navigate a gated access restriction, again via grass pave surface. <br /> <br />Site Access. Front door access the property is planned for the existing curb cut from Stinson <br />Boulevard. The driveway serves a covered front entry canopy area, with guest parking arrayed <br />around the recessed area. <br /> <br />This drive then also accesses a parking area of 16 spaces in front of the south wing, then <br />provides access to the underground parking garage. From this point, the driveway continues to <br />the east to join the shared driveway leading to Kenzie Terrace. <br /> <br />From the rear shared private road, access is available to the northerly employee parking area, <br />as well as the loading location for food service deliveries. The applicants have indicated that <br />trash handling equipment will be located in the underground garage, with access to the <br />equipment a part of the design of the garage entry. <br /> <br />Access-related issues should be subject to further comment and recommendation by the City <br />Engineer. <br /> <br />Setbacks. The PUD zoning district does not impose specific structure setback requirements. <br />For reference purposes however, the following table illustrates setback requirements imposed <br />in the City’s R-4 Multiple Family Residential zoning district (commonly applied to high density <br />residential housing projects) and setbacks proposed by the applicant: <br /> <br /> <br /> R-4 District Setback Proposed Setback <br />Front Yard 30 feet 90 feet <br />Side Yard 15 feet 110 feet (north) <br />110 feet (south) <br />Rear Yard 40 feet or 20 % of the lot <br />depth, whichever is <br />greater <br />55 feet+ <br /> <br />As shown above, the proposed structure setbacks meet or exceed the requirements imposed in <br />the City’s R-4 District. Recognizing that the site is bordered on the north and west by single <br />family, and to the south by commercial uses, shadows cast on adjacent properties (from the <br />five story buildings) are not expected to have impacts on those properties. For these reasons, it <br />is the opinion of staff that the proposed structure setbacks are acceptable. Existing and <br />proposed tree height will already create greater shadow impacts than the building at these <br />setbacks. <br />38