Laserfiche WebLink
<br />Saint Anthony Village Lowry Grove Redevelopment TIF District Building Report <br />LHB Project No. 170752 Page 2 of 2 Parcel B Building 3, Duplex <br />4. Layout and Condition of Interior Partitions/Materials <br />a. Interior walls and ceilings should be repainted. <br />b. Interior carpeting is stained and damaged and should be replaced. <br />c. Kitchen cabinets should be repainted. <br />d. Floor to ceiling height in basement does not comply with code. <br />e. Wood trim is missing around windows. <br /> <br />5. Exterior Construction <br />a. There is excessive vegetation growth around the building, which is contrary to city code. <br />b. The concrete steps leading into both sides of the duplex are damaged and should be <br />repaired. <br />c. Wood trim around front door is missing. <br />d. Roofing material is not properly installed per code. <br />e. Basement windows are boarded up. <br />f. Vinyl siding is damaged allowing for water intrusion, contrary to code. <br />g. Exterior basement door is missing hardware. <br />h. Exposed wood trim should be repainted. <br />i. Chimney brick is damaged and should be repaired to prevent water intrusion per code. <br /> <br /> <br />Description of Code Deficiencies <br /> <br />1. Foundation block walls should be repaired to prevent water intrusion per code. <br />2. All electrical wiring should be properly protected per code. <br />3. HVAC system should be replaced to comply with code. <br />4. All electrical wiring should be replaced to comply with code. <br />5. Basement stairs rise, and run should be modified to comply with code. <br />6. Basement stairway width should be modified to comply with code. <br />7. Code required smoke detectors should be installed. <br />8. Code required carbon monoxide detectors should be installed. <br />9. Arc Fault Circuit Interrupters should be installed to comply with code. <br />10. Electrical outlets should be properly spaced per code. <br />11. Basement floor to ceiling height should be modified to comply with code. <br />12. Excessive vegetative material should be removed to comply with city code. <br />13. Roofing material should be replaced to comply with code. <br />14. Vinyl siding should be repaired to prevent water intrusion per code. <br />15. Chimney brick should be repaired to prevent water intrusion per code. <br /> <br /> <br />Overview of Deficiencies <br />This residential duplex has been vacant for some time and there is excessive vegetative growth surrounding <br />the building. The exterior foundation block is cracked and should be repaired and repainted. Interior surface <br />material should be repaired, repainted and or replaced. Access to the basement is not code compliant and the <br />basement floor to ceiling height does not comply with code. Electrical and HVAC systems should also be <br />replaced to comply with code. <br /> <br /> <br /> <br /> <br />O:\17Proj\170752\400 Design\406 Reports\Building Reports\2551-2553 NE Stinson Parkway - Duplex\170752 2551-2553 Stinson Blvd Duplex <br />Building Report.docx <br />45