Laserfiche WebLink
September 14, 2021 <br />Page 7 <br /> <br />As noted previously, the applicant suggests that the nature of the Bremer Bank business plan is <br />less on retail banking and more on commercial banking, making the drive-through stacking less <br />of an issue for the long-term success of the facility. It should be noted that additional stacking <br />beyond that supplied in the proposal would primary impact the parking usage of the Bank, and <br />would not likely impact the public street. <br /> <br />Building Materials. Building Materials area combination of primarily brick and glass, with fiber <br />cement and metal panel accents. The building itself would be as high as 23 feet to the top of <br />the highest parapet, well under the maximum 35 foot building height. <br /> <br />Signage. A monument sign is proposed near the Kenzie Terrace entry is shown on the site plans <br />without specific dimensions. This sign would need to meet the requirements of the city’s sign <br />regulations. One note relates to the required setback, which is no closer than 15 feet to the <br />curb line of the adjoining street. <br /> <br />Landscaping. The landscaping plan illustrates a fairly well landscaped site. The primary <br />comment in this regard would be the existing line of evergreens along Kenzie Terrace. They are <br />proposed to be removed. It would appear that some of these could be retained, although there <br />is no code requirement to do so. The applicant has indicated that they will examine the ability <br />to preserve healthy specimens that do not interfere with the access driveway. <br /> <br />Trash Enclosure. The site plan also includes a detached trash enclosure facility facing the alley. <br />It would be recommended that the trash enclosure, if detached, gain its service access from the <br />interior of the property, rather than the public alleyway. In this regard, staff would encourage <br />an interior trash room within or adjoining the bank building itself, an element staff has seen to <br />be common in other financial institutions due to security. This recommendation has been <br />incorporated into the revised plans. <br /> <br />Lighting. Finally, the applicant has provided a lighting plan that envisions a series of pole- <br />mounted LED downcast lights around the site. The only issue raised in this regard would be the <br />light intensity along the southwest property line, the common boundary with the senior <br />housing building. The photometric plan shows foot-candle estimates ranging up to 3.2 along <br />this boundary. Staff would recommend that modifications to the fixtures be made to limit this <br />to zero at the property lines, given the adjoining residential use. <br /> <br />Multi Family Apartment Building – 2401 Lowry Ave NE <br /> <br />The building is proposed to be a four-story facility. The first level would be a parking level at <br />grade and the upper three floors a mix of one bedroom (30), one bedroom/alcove (17), two <br />bedroom (26), and three bedroom (3) units. <br /> <br />Site Access and Parking. Front door access the property is planned from the existing curb cut <br />along Kenzie Terrace. The applicants would close the westerly curb cut nearest the <br />intersection. As with the new Bremer Bank location, the applicants will need to coordinate <br />access approvals for this project through Hennepin County. The driveway 60 spaces of surface <br />parking arrayed around the site. <br />39