Case Narrative <br />Client: WSB & Associates, Inc Job ID: 310-229849-1 <br />Project/Site: Kenzie Terrace <br />Job ID: 310-229849-1 <br />Laboratory: Eurofins Cedar Falls <br />Narrative <br />Job Narrative <br />310-229849-1 <br />Comments <br />No additional comments. <br />Receipt <br />The samples were received on 4/23/2022 10:30 AM. Unless otherwise noted below, the samples arrived in good condition, and where <br />required, properly preserved and on ice. The temperatures of the 2 coolers at receipt time were 1.4º C and 2.2º C. <br />GC/MS VOA <br />Method 8260D: The following samples were collected in a properly preserved vial; however, the pH was outside the required criteria when <br />verified by the laboratory. The samples were analyzed within the 7-day holding time specified for unpreserved samples: GW-1 <br />(310-229849-1) and GW-4 (310-229849-2). <br />Method 8260D: The continuing calibration verification (CCV) associated with batch 310-351296 recovered above the upper control limit for <br />2-Chlorotoluene(21.1%D), 1,2,3-Trichloropropane(29.4%D), cis-1,3-Dichloropropene(21.1%D), trans-1,3-Dichloropropene(20.2%D), <br />1,1,2,2-Tetrachloroethane(26.9%D), 1,3-Dichloropropane(23.3%D), 4-Chlorotoluene(20.5%D), 4-Methyl-2-pentanone(25.8%D), and <br />1,1,1,2-Tetrachloroethane(20.4%D). The samples associated with this CCV were non-detects for the affected analytes; therefore, the data <br />have been reported. The associated sample is impacted: (CCV 310-351296/3). <br />Method 8260D: The method blank for preparation batch 310-351186 contained 1,2,4-Trimethylbenzene above the reporting limit (RL). <br />None of the samples associated with this method blank contained the target compound; therefore, re-extraction and/or re-analysis of <br />samples were not performed. <br />No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br />GC VOA <br />Method WI-GRO: The following samples were collected in properly preserved vials; however, the pH was outside the required criteria <br />when verified by the laboratory. The sample was analyzed within the 7-day holding time specified for unpreserved samples: GW-1 <br />(310-229849-1). <br />Method WI-GRO: The following sample was collected in a properly preserved vial; however, the pH was outside the required criteria when <br />verified by the laboratory. The sample was analyzed outside the 7-day holding time specified for unpreserved samples but within the <br />14-day holding time specified for preserved samples: GW-4 (310-229849-2). <br />Method WI-GRO: Significant peaks, readily distinguished from background, were detected in the following sample before the analytical <br />window defined by the first component eluting in the Gasoline Range Organics (GRO) mix (i.e., Methyl tert-butyl ether): GW-4 <br />(310-229849-2). <br />Method WI-GRO: Significant peaks, readily distinguished from background, were detected in the following samples within five minutes <br />after the end of the analytical window defined by the last component eluting in the Gasoline Range Organics (GRO) mix (i.e., <br />Naphthalene): B-4 (10-12) (310-229849-9) and B-4 (14-16) (310-229849-10). <br />No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. <br />GC Semi VOA <br />No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br />Metals <br />No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br />General Chemistry <br />No analytical or quality issues were noted, other than those described in the Definitions/Glossary page. <br />Eurofins Cedar Falls <br />Page 3 of 90 5/17/2022 <br />1 <br />2 <br />3 <br />4 <br />5 <br />6 <br />7 <br />8 <br />9 <br />10 <br />11 <br />12 <br />13 <br />14 <br />15