Laserfiche WebLink
PROPOSED <br />FFE=968.1 <br />3,308 S.F. <br />7 <br />13 <br />11 <br />T COSS-2 <br />RE:963.63 <br />IE:958.11 S <br />IE:955.08 W <br />29 LF - 4" PVC <br />@ 17.57% <br />19 LF - 4" PVC <br />@ 2.00% <br />SS-1 <br />IE:958.50 N <br />SS-5 <br />(CONNECT TO EXISTING MH) <br />RE:963.36 <br />IE:949.29 N <br />IE:949.89 S <br />IE:950.00 E <br />IE:948.59 W <br />PROPOSED WATER METER <br />REMOTE READ LOCATION <br />(SEE ARCH PLANS) <br />PROPOSED ELECTRICAL METER <br />PANEL LOCATION <br />(SEE ARCH PLANS) <br />PROPOSED GAS METER <br />PANEL LOCATION <br />(SEE ARCH PLANS) <br />CONNECT TO EXISTING <br />WATER MAIN <br />CONTRACTOR TO COORDINATE <br />WITH ELECTRIC PROVIDER FOR <br />CONNECTION <br />PROPOSED TRANSFORMER <br />LOCATION <br />CONTRACTOR TO COORDINATE <br />WITH GAS PROVIDER FOR <br />CONNECTION <br />CONTRACTOR TO COORDINATE <br />WITH TELECOM PROVIDER FOR <br />CONNECTION <br />This document, together with the concepts and designs presented herein, as an instrument of service, is intended only for the specific purpose and client for which it was prepared. Reuse of and improper reliance on this document without written authorization and adaptation by Kimley-Horn and Associates, Inc. shall be without liability to Kimley-Horn and Associates, Inc.SHEET NUMBER 2022 KIMLEY-HORN AND ASSOCIATES, INC.767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114PHONE: 651-645-4197WWW.KIMLEY-HORN.COMK:\TWC_LDEV\the architects partnership\st. anthony, mn - chase bank\3 Design\CAD\plansheets\C6-UTILITY PLAN.dwg May 13, 2022 - 12:52pmBYREVISIONSNo.DATEPRELIMINARY - NOT FOR CONSTRUCTIONPREPARED FORUTILITY PLANC600CHASE BANK - SILVERLAKE RD & 39TH AVETHE ARCHITECTSPARTNERSHIPST. ANTHONYMNDATE:I HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION OR REPORT WAS PREPARED BYME OR UNDER MY DIRECT SUPERVISION ANDTHAT I AM A DULY LICENSED PROFESSIONALENGINEER UNDER THE LAWS OF THE STATE OFMINNESOTA.MNLIC. NO.BRIAN M. WURDEMAN, P.E.05/02/202253113DATECHECKED BYSCALEDESIGNED BYDRAWN BYKHA PROJECT16009402905/02/2022AS SHOWNSJSSJSBMWUTILITY PLAN NOTES <br />1.ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF <br />PROPOSED UTILITIES. <br />2.SANITARY SEWER PIPE SHALL BE AS FOLLOWS: <br />8" PVC SDR35 PER ASTM D-3034, FOR PIPES LESS THAN 12' DEEP <br /> 8" PVC SDR26 PER ASTM D-3034, FOR PIPES MORE THAN 12' DEEP <br />6" PVC SCHEDULE 40 PER ASTM D-1785 <br />DUCTILE IRON PIPE PER AWWA C150 <br />3.WATER LINES SHALL BE AS FOLLOWS: <br />6" AND LARGER, PVC C-900 PER ASTM D 2241 <br />CLASS 200 UNDER COUNTY ROADS, OTHERWISE CLASS 150 <br />4" AND LARGER DUCTILE IRON PIPE PER AWWA C150 <br />SMALLER THAN 3" PIPING SHALL BE COPPER TUBE TYPE "K" PER <br />ANSI 816.22 OR PVC, 200 P.S.I., PER ASTM D1784 AND D2241. <br />4.MINIMUM TRENCH WIDTH SHALL BE 2 FEET. <br />5.ALL WATER JOINTS ARE TO BE MECHANICAL JOINTS WITH RESTRAINTS SUCH AS THRUST <br />BLOCKING, WITH STAINLESS STEEL OR COBALT BLUE BOLTS, OR AS INDICATED IN THE <br />CITY SPECIFICATIONS AND PROJECT DOCUMENTS. <br />6.ALL UTILITIES SHOULD BE KEPT TEN (10') APART (PARALLEL) OR WHEN CROSSING 18" <br />VERTICAL CLEARANCE (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE OR <br />STRUCTURE). <br />7.CONTRACTOR SHALL MAINTAIN A MINIMUM OF 7'-5" COVER ON ALL WATERLINES. <br />8.IN THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, <br />STORM LINES AND GAS LINES, OR ANY OBSTRUCTION (EXISTING AND PROPOSED), THE <br />SANITARY LINE SHALL BE SCH. 40 OR C900 WITH MECHANICAL JOINTS AT LEAST 10 FEET <br />ON EITHER SIDE OF THE CENTER LINE OF THE CROSSING. THE WATER LINE SHALL HAVE <br />MECHANICAL JOINTS WITH APPROPRIATE FASTENERS AS REQUIRED TO PROVIDE A <br />MINIMUM OF 18" VERTICAL SEPARATION. MEETING REQUIREMENTS OF ANSI A21.10 OR <br />ANSI 21.11 (AWWA C-151) (CLASS 50). <br />9.LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE <br />BACKFILLING. <br />10.TOPS OF MANHOLES SHALL BE RAISED AS NECESSARY TO BE FLUSH WITH PROPOSED <br />PAVEMENT ELEVATIONS, AND TO BE ONE FOOT ABOVE FINISHED GROUND ELEVATIONS, IN <br />GREEN AREAS, WITH WATERTIGHT LIDS. <br />11.ALL CONCRETE FOR ENCASEMENTS SHALL HAVE A MINIMUM 28 DAY COMPRESSION <br />STRENGTH AT 3000 P.S.I. <br />12.EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW <br />LINES. <br />13.REFER TO INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL UTILITIES. <br />14.CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE CITY <br />OF ST. ANTHONY AND/OR STATE OF MN WITH REGARDS TO MATERIALS AND INSTALLATION <br />OF THE WATER AND SEWER LINES. <br />15.THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION <br />OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE <br />VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE <br />FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE <br />CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS <br />BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL <br />BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES <br />WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. <br />16.CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY INSPECTIONS AND/OR <br />CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES. <br />17.CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION <br />REQUIREMENTS AND SPECIFICATIONS. <br />18.CONTRACTOR SHALL REFERENCE ARCH / MEP PLANS FOR SITE LIGHTING AND <br />ELECTRICAL PLAN. <br />19.BACKFLOW DEVICES (DDCV AND PRZ ASSEMBLIES) AND METERS ARE LOCATED IN THE <br />INTERIOR OF THE BUILDING. REF. ARCH / MEP PLANS. <br />20.ALL ONSITE WATERMAINS AND SANITARY SEWERS SHALL BE PRIVATELY OWNED AND <br />MAINTAINED. <br />21.ALL WATERMAIN STUBOUTS SHALL BE MECHANICALLY RESTRAINED WITH REACTION <br />BLOCKING. <br />NORTH <br />SANITARY SEWER MANHOLE <br />STORM SEWER <br />SANITARY SEWER <br />WATERMAIN <br />GATE VALVE <br />HYDRANT <br />TEE <br />REDUCER <br />UNDERGROUND ELECTRIC <br />TELEPHONE <br />GAS MAIN <br />STORM SEWER <br />LEGEND <br />CO SANITARY CLEANOUTCO <br />EXISTING PROPOSED