Laserfiche WebLink
UP <br />UP <br />HPHP <br />1. DO NOT SCALE DRAWINGS. <br />2. REPORT ANY DISCREPANCIES TO DESIGNER/BUILDER OWNER. <br />3. ALL WORK TO CONFORM TO STATE & LOCAL CODES. <br />4. ALL WORK TO BE PERFORMED TO INDUSTRY STANDARDS. <br />5. NO SUBSTITUTIONS WITHOUT ARCHITECTS/DESIGNERS APPROVAL. <br />6. ALL EXPOSED SURFACES TO BE PREPARED TO RECEIVE NEW FINISHES. <br />7. SUB-CONTRACTORS ARE RESPONSIBLE TO REVIEW ALL CONSTRUCTION <br />DRAWINGS, ELEVATIONS, & DETAILS. <br />8. PATCH TO MATCH ADJACENT SURFACES WHERE DEMOLITION OCCURS. <br />9. PROVIDE & INSTALL FIRE RETARDANT BLOCKING IN WALLS AS REQUIRED <br />AT ALL AREAS WITH BUILT-IN COUNTERS, SHELVING, CABINETS, ETC. <br />10. BEFORE STARTING ANY WORK EACH CONTRACTOR SHALL EXAMINE WORK <br />PERFORMED BY OTHERS TO WHICH HIS WORK ADJOINS OR IS APPLIED. <br />REPORT TO THE DESIGNER ANY CONDITIONS THAT WILL PREVENT <br />SATISFACTORY COMPLETION OF WORK. <br />11. THE CONTRACTOR SHALL GIVE TO THE PROPER AUTHORITIES ALL NOTICES <br />AS REQUIRED BY LAW & OBTAIN ALL OFFICIAL BUILDING PERMITS. <br />12. UPON COMPLETION OF WORK, THE TENANT SPACE PREMISES, & ADJOINING <br />AREAS SHALL BE MADE NEAT, CLEAN, WHOLE, TIGHT & FIT FOR IMMEDIATE <br />OCCUPANCY. EACH INDIVIDUAL CONTRACTOR IS RESPONSIBLE TO CLEAN <br />UP & MAKE AREAS NEAT THAT WERE AFFECTED BY THEIR WORK. <br />13. ANY PENETRATIONS THROUGH NEW OR EXISTING (1) HOUR FIRE RATED <br />WALLS ARE TO BE SEALED WITH FIRESTOP CAULK AS REQUIRED BY CODE <br />TO MAINTAIN (1) HOUR FIRE RATED SEPARATION. ALL SUB-CONTRACTORS <br />RESPONSIBLE. <br />14. CONTRACTOR TO PROVIDE & INSTALL FIRE EXTINGUISHERS AS REQUIRED <br />BY FIRE MARSHAL ALL OFFICE EXTINGUISHERS TO BE SEMI-RECESSED. ALL <br />WAREHOUSE EXTINGUISHERS TO BE WALL MOUNTED. <br />15. PHONE BOARD TO BE FIRE RETARDANT, INTERIOR SOUND GRADE (2) -B-D <br />INT APA-UTILITY PANEL WITH ONE SOLID SIDE FOR A SMOOTH PAINTED <br />SURFACE. <br />16. ALL PARTITIONS IN EXCESS OF 30' LENGTHS SHALL HAVE FULL HEIGHT <br />CONTROL JOINTS INSTALLED WITH 30' MAXIMUM SPACING. <br />17. ALL RATED DOORS ARE TO BE LABELED AS A SMOKE & DRAFT CONTROL <br />DOOR MEETING THE REQUIRED UL1784 DOOR TESTED USING NFPA 252. <br />18. ALL RATED SIDELIGHTS REQUIRED TO MEET NFPA 257 TESTING. <br />FLOOR PLAN GENERAL NOTES <br />5/8" GYP. BD. <br />3 5/8" STEEL STUD <br />5/8" GYP. BD. <br />WALL TYPES/ LEGEND <br />P5 <br />SYMBOL <br />DESIGNATION <br />P3 <br />DS1HR <br />3'-4" <br />A <br />E = EXISTING WALL <br />X = EXTERIOR WALL <br />P = PARTITION <br />C = COOLER/ FREEZER - <br />PROVIDED BY OTHERS <br />R = RATED WALL <br />3 = SEE WALL TYPES <br />TO THE RIGHT FOR <br />CONSTRUCTION <br />TYPE <br />P = WALL TO PLENUM 6" <br />MIN. ABOVE CEILING <br />D = WALL TO DECK <br />S = SOUND <br />INSULATION <br />C = TERMINATE WALL <br />AT CEILING <br />F = FURRING <br />WALL RATING <br />WALL HEIGHT <br />A = SOUND BLANKET <br />ABOVE CEILINGV = ONE-SIDED FINISH WALL <br />A. PARTITIONS ARE DIMENSIONED IN <br />PLAN FINISH FACE TO FINISH FACE. <br />B. PARTITION SYMBOL MAY BE USED <br />IN CONJUNCTION WITH NOTES TO <br />MODIFY CONSTRUCTION FOR <br />UNIQUE CONDITIONS. <br />C. STUDS ARE 16" O.C. MAXIMUM <br />UNLESS OTHERWISE NOTED. <br />D. GYP. BD. IS TO BE 5/8" UNLESS <br />NOTED OTHERWISE. <br />E. GYP. BD. IS TO BE MOISTURE <br />RESISTANT AT ALL WET WALLS TO <br />48" A.F.F. MINIMUM. <br />F. ALL FULL HEIGHT WALLS ARE TO <br />BE CONSTRUCTED WITH A <br />MOVEMENT HEAD TRACK <br />PROVIDING A MINIMUM OF 2" <br />MOVEMENT. DO NOT ANCHOR GYP. <br />BD. TO HEAD. <br />U = SOUND RATED WALL <br />L = LEAD-LINED WALL <br />D = DOUBLE STUD WALL <br />GB/PL1/W1 = GYPSUM BD. <br />PLASTIC LAMINATE OR <br />WOOD CAPPED WALL <br />T = EXISTING WALL <br />EXTENDED TO DECK <br />S = SOFFIT <br />5/8" GYP. BD. <br />3 5/8" STEEL STUD 6" STEEL STUD <br />5/8" GYP. BD. <br />F4 F6 <br />P1 <br />P2 <br />A401 <br />1 <br />Walk-In <br />Freezer <br />118 <br />Walk-In <br />Freezer <br />117 <br />Kitchen <br />114 <br />Laundry <br />113Mech <br />112 <br />Women <br />111 <br />Men <br />110 <br />IT/ Server <br />109 <br />Open <br />Office <br />107 <br />Office <br />106 <br />Office <br />105 <br />Office <br />104 <br />Employee <br />Entry <br />103 <br />Sprinkler <br />102 <br />Production <br />101 <br />Vestibule <br />1004 7/8"11' - 10"13' - 4" +/-4 7/8"13' - 4" +/-4 7/8"22' - 4 1/8" +/-4 7/8"16' - 9 1/2"4 7/8"7' - 2"14' - 8"4 7/8"6 5/8"25' - 4 5/8"Walk-In <br />Cooler <br />116 <br />Warehouse <br />115 <br />P5DSP5P5P5 <br />DS <br />P5P5P5 <br />DS <br />P5P5 F4F4F4P5DSP5P5P5DSP5P5EX <br />EXEX <br />EXEX EXEXEXEX <br />5' - 0"14' - 2" <br />4 7/8"62' - 3 5/8"6 5/8" <br />5' - 3" <br />4 7/8" <br />8' - 10 5/8"4 7/8"P5DSP5P54' - 0"113111110109104105106Break <br />108 F6SF6F6F6 <br />S <br />F6F6 <br />F6SF6F6P5P5P5 <br />P1 <br />P2 <br />P3 <br />A401 <br />10 <br />A600 <br />3 <br />Sim <br />A600 <br />3 <br />Sim <br />1 <br />A600 <br />2 <br />A600 <br />102 <br />NO. Print History Date <br />Signature : <br />Name : <br />Registration : <br />Project <br />Checked <br />Drawn <br />Project Contact : <br />Phone Number :952-541-9969 <br />P R E L I M I N A R Y <br />N O T F O R <br />C O N S T R U C T I O N <br />C1 <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />PERMIT 12-07-22 <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />- <br />RYAN SCHROEDER <br />22166 <br />JCP <br />RAS <br />ASIAN MILL <br />Minneapolis, MN <br />FLOOR PLAN <br />A101 <br />ASIAN MILL <br />3601 29th AVENUE NE <br />MINNEAPOLIS, MN <br />55418 <br />N <br />1/8" = 1'-0"1 FLOOR PLAN - 01 <br /><PLAN NOTES> <br />NO.DESCRIPTION <br />P1 ALIGN FINISH FACE OF WALL WITH FINISH FACE OF EXISTING OPENING/ WALL. <br />P2 TRENCH DRAIN <br />P3 NEW WATER HEATER, SEE MECHANICAL. <br />NO <br />.Description Date