Laserfiche WebLink
September 18, 2024 <br />City Council – City of St. Anthony Village <br />Page 2 of 4 <br />Reference: Environmental Conditions Summary – Proposed Tibyan Community Center, 2401 Lowry Avenue NE, St. Anthony, <br />Minnesota (the Site) <br /> <br />In February and March 2018, a paired sub-slab soil vapor and indoor/outdoor air sampling event was <br />performed in support of a completed pathway evaluation, which was an acceptable soil vapor risk assessment <br />strategy at that time. Five sub-slab soil vapor samples and five paired indoor air samples were collected from <br />within the building footprint, five external soil vapor samples were collected from locations within the parking <br />lot, and an ambient air sample was collected from outside of the building. Soil vapor beneath the parking lot <br />was impacted by numerous VOCs, including PCE and TCE at concentrations greater than 33X the MPCA’s <br />industrial EISV. Sub-slab soil vapor collected from within the building footprint had TCE at concentrations <br />greater than 33X the MPCA’s industrial ISV. Soil vapor was also impacted by elevated levels of <br />dichlorodifluoromethane and cis-1,2-DCE, however an ISV had not been established for <br />dichlorodifluoromethane or cis-1,2-DCE at the time. Indoor air samples contained contaminants of concern in <br />concentrations below the MPCA’s industrial ISVs. <br />In April 2018, November 2018, May 2019, and June 2020 subsequent seasonal sampling events were <br />performed in support of the completed pathway evaluation. For each sampling event, five sub-slab soil vapor <br />samples and five paired indoor air samples were collected from within the building footprint and an ambient <br />air sample was collected from outside of the building. Sub-slab soil vapor was impacted by TCE at <br />concentrations greater than 33X the industrial ISV and PCE was detected in sub-slab soil vapor at <br />concentrations less than 33X the industrial ISV but greater than 33X the residential ISV. Sub-slab soil vapor <br />was also impacted by trans-1,2-DCE at concentrations less than the industrial ISV and by cis-1,2-DCE. Indoor <br />air concentrations were again less than the MPCA’s industrial ISV. As a result of the completed pathway <br />evaluation, an active vapor mitigation system was recommended to be installed in any future occupied Site <br />building. <br />Subsequent investigations were completed at the Site in June 2023 to further delineate soil and groundwater <br />impacts around the Site. Soil investigation activities included the advancement of nine push-probe borings for <br />the collection of 11 soil samples and four groundwater samples. Soil analytical testing detected RCRA metal <br />and PAH impacts that did not exceed their respective SRVs and SLVs. DRO was detected below the <br />unregulated fill criteria. VOC analysis detected concentrations of PCE and TCE above its SLV in samples <br />collected from the northern half of the Site. Groundwater analytical results from temporary wells identified the <br />presence of PCE, TCE, and cis-1,2-DCE above their respective HRLs or Health Based Values (HBVs) in <br />borings collected from the north and east portions of the Site. <br />Copies of the investigation reports detailed above can be made available upon request. <br />2024 Indoor Air Sampling Event <br />On behalf of Tibyan Community Center, Stantec completed indoor air sampling in August 2024 to assess <br />indoor air conditions at the Site building following a period of vacancy. The indoor air sampling event <br />consisted of the placement of three laboratory-provided summa canisters equipped with a 24-hour flow <br />controller. The three samples were placed in the basement in the east and west mechanical rooms, both <br />located in the southwest portion of the Site building, and the main lobby area located in the northeast portion <br />of the building. Sample results identified PCE in a concentration exceeding its MPCA industrial ISV in the <br />main lobby area. PCE was also detected in concentrations exceeding its MPCA residential ISV in the other <br />two samples, and TCE was detected in a concentration exceeding its MPCA residential ISV in the main lobby. <br />Indoor air sample locations are shown on Figure 3, and a summary table is included as Table 1. A vapor <br />intrusion building survey form is included as Attachment A. The full laboratory report can be made available <br />upon request. <br /> <br />73