Laserfiche WebLink
OHPOHPOHPOHPOHPOHPOHPOHPOHP <br />SNSNSNSNSNSNSNSNSNSNIIIIIIIIIISNSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTST <br />S <br />T <br />S <br />T <br />S <br />T <br />S <br />T <br />ST ST <br />STSTSTSTSTSTCURB & GUTTER <br />CURB & GUTTERCURB & GUTTERVALLEY GUTTERVALLEY GUTTERCURB & GUTTERGARAGE <br />BUILDING <br />FLOOR ELEV.=946.15 <br />SITE BENCHMARK <br />TOP HUT HYDRANT <br />ELEV.=953.00 <br />ST <br />ST <br />SN <br />GARAGE <br />RIM=944.55 <br />INV(S)=938.25 <br />INV(E)=938.15 <br />RIM=938.94 <br />INV(E)=931.74 <br />INV(W)=933.04 <br />RIM=944.28 <br />INV=940.06 <br />RIM=945.85 <br />INV(E)=935.02 <br />INV(N)=935.39 <br />INV(W)=936.80 <br />RIM=940.38 <br />INV=937.55 <br />RIM=925.31 <br />INV=921.76 <br />RIM=931.32 <br />INV=925.92 <br />RIM=943.47 <br />INV=930.83 <br />RIM=948.09 <br />INV=932.62 SN 400C <br />RETAINING WALL <br />N 89°25'03" E 298.82 <br />S 00°10'57" E 124.63S 89°24'24" W 298.51N 00°19'27" W 124.68(PLATTED AS OAKWOOD DRIVE)STSTSTSTSTSTST93 <br />9 <br />94 <br />0 <br />941 <br />942 <br />943 <br />944 <br />945 <br />946 <br />947 <br />948 <br />949 <br />945 <br />946 <br />947 <br />948 <br />949 <br />950 <br />951 <br />952 <br />941 <br />942 <br />943944 <br />945944 <br />947 <br />948 <br />949945 <br />946 <br />947948949950941 <br />940 <br />945 <br />946 <br />939 <br />93 <br />4 <br />93 <br />5 <br />93 <br />6 <br />937 <br />93 <br />8 93393 <br />2931 <br />OHPOHPOHPOHPOHPOHPOHPOHPOHP951950 <br />0 20 40 <br />SCHULTZ ENG. PROJECT NO.: 25005 <br />DRAWN BY: NES <br />REVIEWED BY: BJS <br />© SCHULTZ ENGINEERING & SITE <br />DESIGN, PLLC 2025 <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED ENGINEER UNDER THE LAWS <br />OF THE STATE OF MINNESOTA <br />18 SOUTH RIVERSIDE AVENUE, SUITE 230 <br />SARTELL, MINNESOTA 56377 <br />PH: (320) 339-0669 <br />FX: (866) 633-1830 <br />schultzeng@live.com <br />www.schultzengdesign.com <br />FOSS ROAD <br />ST. ANTHONY VILLAGE, MN <br />C4 <br />SCALE: 1"=20' <br />N <br />GRADING PLAN <br />ABLE VIEW <br />ASSISTED LIVING <br />DATENO. <br />1 <br />2 <br />ISSUE DATE: 03/31/2025 <br />xx/xx/2025 <br />xx/xx/2025 <br />REVISIONS <br />SCHULTZ ENGINEERING& SITE DESIGN <br />DESCRIPTION <br />3 xx/xx/2025 <br />4 xx/xx/2025 <br />CIVIL SHEET INDEX <br />C1 - STANDARD NOTES & SPECIFICATIONS <br />C2 - STANDARD DETAILS <br />C3 - DEMOLITION & REMOVALS PLAN <br />C4 - GRADING PLAN <br />C5 - SWPPP - STANDARD NOTES <br />C6 - SWPPP - PLAN VIEW <br />C7 - UTILITY & PAVING PLAN <br />EX-FL <br />HP <br />EX EX EX EX <br />HP <br />EX-FL <br />EX-FL <br />GRADING NOTES: <br />3. EXISTING TOPOGRAPHICAL INFORMATION WAS OBTAINED FROM A TOPOGRAPHICAL SURVEY <br />COMPLETED BY O'MALLEY & KRON LAND SURVEYORS, COLD SPRING, MN. (320) 685-5905 <br />4. BENCHMARK: TOP NUT OF HYDRANT LOCATED APPROX. 12-FT NORTHWEST OF SOUTHWEST <br />PROPERTY CORNER, ON THE EAST SIDE OF FOSS ROAD (SEE PLAN) - ELEV = 953.00. <br />2. NOTIFY ENGINEER IMMEDIATELY IF ANY INCONSISTENCIES ARE DISCOVERED BETWEEN ACTUAL <br />SITE CONDITIONS AND WHAT IS SHOWN ON THE PLANS, WHICH ARE SIGNIFICANT ENOUGH TO <br />ALTER THE INTENT OF THE DRAWINGS. <br />5. CONTRACTOR SHALL CONTACT GOPHER ONE CALL AT (800) 252-1166 FOR A UTILITY LOCATE <br />PRIOR TO THE START OF CONSTRUCTION AND VERIFY LOCATIONS OF EXISTING UTILITIES BEFORE <br />BEGINNING WORK. <br />6. SEE SHEET C2 FOR STANDARD DETAILS. <br />14. ALL SPOT ELEVATIONS AND CONTOURS INDICATED ON THIS PLAN ARE INTENDED TO PROVIDE <br />ADEQUATE POSITIVE DRAINAGE TOWARDS CATCH BASINS, CURB CUTS, PONDS, BASINS AND/OR <br />OTHER OUTLETS. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT SPECIFIED SURFACE <br />INFRASTRUCTURE TO ELEVATIONS AND GRADES INDICATED ON THIS PLAN, AS WELL AS ENSURE <br />THAT ADEQUATE POSITIVE DRAINAGE IS CONSTRUCTED AND MAINTAINED THROUGHOUT THE <br />ENTIRE SITE AND/OR CONSTRUCTION AREA. <br />1. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING SITE CONDITIONS INCLUDING, BUT NOT LIMITED <br />TO, THE FOLLOWING: <br />* LOCATIONS, DEPTHS, SIZES, AND MATERIAL TYPES OF EXISTING SANITARY, WATER, AND <br />STORM SEWER UTILITIES, INCLUDING EXISTING STUBS <br />* RIM AND INVERT ELEVATIONS OF EXISTING SANITARY AND STORM SEWER UTILITIES, <br />INCLUDING EXISTING STUBS <br />* LOCATIONS AND DEPTHS OF EXISTING NON-SEWER AND NON-WATER UTILITIES (IE: GAS, <br />ELECTRIC, COMMUNICATIONS, ETC.) <br />* EXISTING ABOVE-GROUND INFRASTRUCTURE AND SITE FEATURES <br />12. SPOT ELEVATIONS INDICATED ON THIS PLAN REPRESENT FINISHED SURFACE ELEVATIONS, <br />UNLESS NOTED OTHERWISE. <br />SPOT ELEVATIONS LOCATED ALONG CURB & GUTTER OR THICKENED EDGE SIDEWALK REPRESENT <br />FLOWLINE ELEVATIONS OF GUTTER SECTION OR ADJACENT PAVEMENT. TOP-OF-CURB OR <br />TOP-OF-THICKENED EDGE SIDEWALK SURFACE ELEVATIONS ARE 6" ABOVE THE FLOW LINE SPOT <br />ELEVATION SHOWN ON THE PLANS, UNLESS NOTED OTHERWISE. <br />11. CONTRACTOR SHALL PERFORM ALL NECESSARY CALCULATIONS TO VERIFY EARTHWORK <br />QUANTITIES. CONTRACTOR'S BID RELATED TO EARTHWORK, CUTTING, FILLING, GRADING , ETC. <br />SHALL BE BASED ON EARTHWORK CALCULATIONS COMPLETED BY THE CONTRACTOR. <br />16. CONTRACTOR SHALL CONTRACT WITH A LICENSED STRUCTURAL ENGINEER FOR DESIGN OF <br />ANY RETAINING WALLS SHOWN ON THIS PLAN. <br />17. LINEAL FOOTAGE AND HEIGHTS OF ANY RETAINING WALLS SHOWN ON THIS PLAN ARE <br />ESTIMATED, BASED ON THE TOPOGRAPHIC SURVEY BACKGROUND, AND SHALL BE VERIFIED BY <br />THE CONTRACTOR IN THE FIELD. <br />NOTE: CADD FILES FOR ESTIMATING EARTHWORK QUANTITIES ARE AVAILABLE TO CONTRACTORS <br />FOR PREPARING BIDS. IN ORDER TO RECEIVE THE CADD FILES, THE CONTRACTOR WILL NEED TO <br />SIGN A HOLD-HARMLESS AGREEMENT PROVIDED BY SCHULTZ ENGINEERING & SITE DESIGN, AND <br />AGREE TO PAY A $50 PROCESSING FEE. THE CADD FILES WILL BE RELEASED UPON RECEIPT OF <br />THE CHECK <br />7. ALL LENGTHS OF STORM SEWER OR CULVERT PIPE SPECIFIED ON THIS PLAN INCLUDE THE <br />LENGTHS OF ANY ASSOCIATED FLARED END SECTIONS. <br />10. FINISHED ELEVATIONS OF LANDSCAPED AREAS IMMEDIATELY ADJACENT TO BUILDINGS SHALL <br />BE A MINIMUM OF 6" BELOW FINISHED FLOOR OR TOP-OF-BLOCK ELEVATION, UNLESS NOTED <br />OTHERWISE ON THE PLAN. <br />8. TRASH GUARDS SHALL BE INSTALLED ON ALL STORM SEWER END SECTIONS. <br />IF REQUIRED BY THE MN DEPT. OF LABOR AND INDUSTRY (MNDLI), OWNER AND/OR CONTRACTOR <br />SHALL SUBMIT FOR STATE PLUMBING REVIEW, AND OBTAIN AN APPROVED PLUMBING REVIEW <br />REPORT FROM MNDLI, PRIOR TO THE INSTALLATION OF ANY STORM SEWER UTILITIES. <br />CONSTRUCTION OF STORM SEWER UTILITIES SHALL NOT COMMENCE UNTIL AFTER THE APPROVED <br />PLUMBING REVIEW REPORT HAS BEEN OBTAINED, AND ANY AND ALL PERTINENT COMMENTS <br />HAVE BEEN ADDRESSED ON THE PLANS AND IN THE PROJECT SPECIFICATIONS. CONTRACTOR IS <br />ADVISED TO ORDER STORM SEWER UTILITY MATERIALS AFTER APPROVED PLUMBING REVIEW <br />REPORT HAS BEEN OBTAINED FROM MNDLI <br />13. SPOT ELEVATION DESIGNATIONS: <br />* "EX" DENOTES EXISTING SPOT ELEVATION <br />* "HP" DENOTES HIGH POINT <br />* "FL" DENOTES FLOWLINE <br />* "BC" DENOTES BACK OF CURB <br />* "EC" DENOTES EDGE OF CONCRETE <br />* "EP" DENOTES EDGE OF PAVEMENT <br />* "BD" DENOTES GRADE AT BUILDING BELOW DECK <br />18. CONTRACTOR SHALL PROVIDE RAILING ALONG RETAINING WALL AS REQUIRED BY CODE. <br />9. STORM SEWER STRUCTURE DESIGNATIONS: <br />* "CB" DENOTES PRECAST CONCRETE CATCH BASIN <br />* "NP" DENOTES NYLOPLAST CATCH BASIN <br />* "STMH" DENOTES PRECAST CONCRETE STORM SEWER MANHOLE <br />* "STCO" DENOTES STORM SEWER CLEANOUT <br />* "("XX" ID)" DENOTES INTERIOR DIAMETER OF STRUCTURE <br />15. CONTRACTOR SHALL HIRE A LICENSED SURVEYOR TO PROVIDE STAKING FOR THE <br />CONSTRUCTION OF THE FILTRATION BASIN. THE CONTRACTOR IS RESPONSIBLE TO CONSTRUCT THE <br />FILTRATION BASIN TO THE SIZE AND ELEVATIONS INDICATED ON THE PLAN, SUCH THAT IT CONTAINS <br />THE STORAGE VOLUME(S) ASSUMED IN IT'S DESIGN. <br />FILTRATION BASIN (FB1)1 <br />HAALA PS48-58S CASTING W/ WEDGE <br />ANCHORS, OR APPROVED EQUIVALENT <br />(INSTALL PER MANUFACTURER'S <br />REQUIREMENTS AND SPECIFICATIONS <br />EX-FL <br />EX-FL BD <br />BD <br />BD <br />DATE: 03/31/2025 <br />944 <br />942 <br />940 <br />936940938942946946 <br />948950 <br />93 <br />8 <br />9 <br />3 <br />6 940940 <br />9409429369389 <br />4 <br />6 <br />944946 <br />94 <br />4 944PROPOSED BUILDING <br />FFE = 948.25 <br />RETAINING WALL #1 <br />HEIGHT = 0 TO 5.0-FT <br />LENGTH = 200-FT <br />CB1 (27" ID) <br />RIM = 945.60 <br />INV = 942.60 <br />CB2 (48" ID) <br />RIM = 943.00 <br />INV = 939.50 <br />SUMP = 935.50 <br />174 LF <br />12" HDPE <br />@ 1.78% <br />42 LF <br />12" HDPE <br />@ 1.67% <br />CLEANOUT (CO1) <br />RIM = 947.05 <br />INV = 943.58 <br />CLEANOUT (CO2) <br />RIM = 946.75 <br />INV = 941.98 <br />CLEANOUT (CO3) <br />RIM = 943.65 <br />INV = 940.38 <br />CLEANOUT (CO5) <br />RIM = 949.90 <br />INV W = 944.85 <br />INV E = 943.55 <br />CLEANOUT (CO4) <br />RIM = 950.85 <br />INV = 946.85 <br />100 LF <br />4" SCH 40 PVC <br />@ 2.00%100 LF <br />6" SCH 40 PVC <br />@ 2.00% <br />12" FLARED <br />END SECTION <br />INV = 938.80 <br />12" FLARED <br />END SECTION <br />INV = 938.80 <br />44 LF <br />6" PVC <br />@ 2.00% <br />80 LF <br />6" PVC <br />@ 2.00% <br />80 LF <br />4" PVC <br />@ 2.00%FILTRATION BASIN (FB1) <br />(SEE 1/C3) <br />BOTTOM OF BASIN = 935.80 <br />BASIN OUTLET = 938.80 <br />TOP OF BASIN = 941.00 <br />WATER QUALITY LEVEL = 937.80 <br />100-YR PEAK HWL = 940.02 <br />BASIN EMERGENCY OVERFLOW = 940.10 <br />TOP OF BERM <br />ELEV = 945.00 (TYP) <br />TOP OF BERM <br />ELEV = 941.00 (TYP) <br />NOTE: BUILDING DOWNSPOUTS TO BE CONNECTED TO <br />ADJACENT STORM SEWER "MAIN" VIA 4" PVC LATERALS <br />WITH ALL NECESSARY FITTINGS, BENDS, AND WYES. <br />VERIFY DOWNSPOUT LOCATIONS WITH ARCHITECTURAL. <br />STMH2 (48" ID) <br />RIM = 945.25 <br />INV W = 941.55 <br />INV NE, NW = 939.24 <br />SUMP = 935.24 <br />4" SCH 40 PVC <br />@ 2.00% <br />(TYP) <br />4" SCH 40 PVC <br />@ 2.00% <br />(TYP) <br />4" SCH 40 PVC <br />@ 2.00% <br />(TYP) <br />4" SCH 40 PVC <br />@ 2.00% (TYP) <br />14 LF <br />12" HDPE <br />@ 2.00% <br />10 LF <br />12" HDPE <br />@ FLAT <br />OUTLET CONTROL <br />STRUCTURE (OCS1) <br />(SEE 1/C3) <br />BASIN EMERGENCY OVERFLOW <br />ELEV = 940.10 (TYP) <br />CONNECT TO EXISTING <br />18" RCP STORM SEWER <br />W/ NEW MANHOLE <br />INV = 928.19 <br />(FIELD VERIFY) <br />STMH3 (48" ID) <br />RIM = 937.90 <br />INV S = 933.52 <br />INV E/W = 928.19 <br />DEMOLITION LIMITS (TYP) <br />(AT PROPERTY LINE) <br />NOTE: BUILDING DOWNSPOUTS TO BE CONNECTED TO <br />ADJACENT STORM SEWER "MAIN" VIA 4" PVC LATERALS <br />WITH ALL NECESSARY FITTINGS, BENDS, AND WYES. <br />VERIFY DOWNSPOUT LOCATIONS WITH ARCHITECTURAL. <br />3: <br />1 <br />3:118" SOIL MEDIUM: <br />70% CLEAN SAND & 30% <br />COMPOST MIX (MN STORM <br />WATER MANUAL MIX "B") <br />LENGTH VARIES <br />INVERT <br />BOTTOM <br />BASINBOTTOM <br />SAND-MEDIUM <br />BASIN OUTLET <br />12" HDPE <br />(SEE PLAN) <br />PERFORATED DRAINTILE <br />SURROUNDED BY 1"-2" <br />WASHED CRUSHED ROCK <br />(4" DRAINTILE UNLESS <br />NOTED OTHERWISE) <br />NON-PERFORATED DRAINTILE <br />OUTSIDE OF BASIN SECTION <br />(4" DRAINTILE UNLESS NOTED <br />OTHERWISE) <br />MNDOT 3733 TYPE 1 FILTER <br />FABRIC OVERLYING <br />CRUSHED ROCK / DRAINTILE <br />FILTRATION BASIN ELEVATIONS <br />FILTRATION <br />BASIN <br />FB1 <br />DRAINTILE <br />INVERT <br />933.80 <br />SAND <br />BOTTOM <br />934.30 <br />BASIN <br />BOTTOM <br />935.80 <br />BASIN <br />OUTLET <br />938.80 <br />12" HDPE <br />(SEE PLAN) <br />OVERFLOW <br />GRATE <br />TOP OF <br />BERM <br />941.00 <br />TOP OF <br />BERM <br />OVERFLOW <br />GRATE <br />941.00 <br />12" FES (SEE PLAN) <br />NOTE: BOTTOM OF BASIN TO <br />BE PROVIDED WITH NATIVE <br />PLANTINGS AND/OR PLUGS <br />UPSTREAM CLEANOUT <br />4" SCH 40 PVC <br />NON-PERFORATED <br />WATERTIGHT <br />CAP <br />DOWNSTREAM <br />CLEANOUT <br />4" SCH 40 PVC <br />NON-PERFORATED <br />WATER- <br />TIGHT <br />CAP <br />100-YEAR <br />PEAK <br />940.02 <br />BOTTOM AND SIDES OF SOIL MEDIUM <br />& CRUSHED ROCK TO BE WRAPPED IN <br />60-MIL HDPE LINER (TOP OF SOIL <br />MEDIUM TO BE EXPOSED TO <br />FACILITATE PLANT GROWTH <br />4" PERFORATED DRAIN <br />TILE (TYP - SEE 1/C3) <br />4" PERFORATED DRAIN <br />TILE (TYP - SEE 1/C3) <br />CLEANOUT W/ <br />WATERTIGHT CAP <br />(TYP - SEE 1/C3) <br />DEMOLITION <br />LIMITS (TYP) <br />DEMOLITION <br />LIMITS (TYP) <br />NOTE: REMOVE EXISTING BITUMINOUS <br />PAVEMENT, CURB & GUTTER, AND <br />VALLEY GUTTER AS NECESSARY FOR <br />NEW UTILITY CONNECTIONS (SEE C3). <br />REPLACE BITUMINOUS PAVEMENT, <br />CURB & GUTTER, AND VALLEY GUTTER <br />PER CITY REQUIREMENTS (SEE C7). <br />22 LF <br />12" HDPE <br />@ 2.00% <br />TOP OF BERM <br />ELEV = 941.00 (TYP) <br />CLEANOUT W/ <br />WATERTIGHT CAP <br />(TYP - SEE 1/C3) <br />CLEANOUT W/ <br />WATERTIGHT CAP <br />(TYP - SEE 1/C3) <br />NOTE: CONTRACTOR SHALL OBTAIN <br />ALL NECESSARY PERMITS AND <br />APPROVALS FOR WORK WITHIN THE <br />PUBLIC RIGHT OF WAY. <br />DEMOLITION LIMITS (TYP) <br />(AT PROPERTY LINE)DEMOLITION LIMITS (TYP) <br />(AT PROPERTY LINE) <br />12" SCH 40 PVC <br />@ 1.00% <br />(TYP) <br />4" SCH 40 PVC <br />@ 1.00% <br />(TYP) <br />CLEANOUT (CO6) <br />RIM = 942.65 <br />INV = 938.92 <br />9 <br />4 <br />0 <br />1. TRAFFIC FROM CONSTRUCTION EQUIPMENT SHALL BE LIMITED AS MUCH AS POSSIBLE <br />ACROSS FILTRATION BASIN AREAS, AND BE ONLY LOW IMPACT TRACK EQUIPMENT. <br />BASIN AREAS SHALL BE EXCAVATED WITH A BACKHOE STATIONED OUTSIDE OF THE AREA <br />AS MUCH AS POSSIBLE. <br />2. DURING CONSTRUCTION OF THE ADJACENT PARKING LOT AND BUILDING, THE <br />FILTRATION BASIN AREA SHALL BE PROTECTED FROM TRAFFIC AND SEDIMENT WITH SILT <br />FENCE. SEE SHEET C6. <br />3. FILTRATION SOIL MEDIA SHALL CONSIST OF MN STORM WATER MANUAL MIX "B". THE <br />CONTRACTOR SHALL NOT INSTALL FILTER MEDIA UNTIL THE CONTRACTOR CONSTRUCTS <br />AND FULLY STABILIZES THE CONTRIBUTING DRAINAGE AREA UNLESS THEY PROVIDE <br />RIGOROUS EROSION PREVENTION AND SEDIMENT CONTROLS (E.G., DIVERSION BERMS) <br />TO KEEP SEDIMENT AND RUNOFF COMPLETELY AWAY FROM THE FILTRATION AREA. <br />4. ONCE THE FILTRATION BASIN HAS BEEN EXCAVATED AND BACKFILLED WITH SOIL MEDIA, <br />THE CONTRACTOR SHALL ARRANGE AND PAY FOR TESTING THE INFILTRATION RATES OF <br />THE SOIL MEDIA. THE TEST RESULTS SHALL BE SUBMITTED TO THE WATERSHED DISTRICT <br />AND THE ENGINEER. <br />5. IN ORDER TO PASS, INFILTRATION TESTING RESULTS SHALL BE IN A SATURATED STATE AND <br />MUST BE NO LESS THAN DOUBLE THE DESIGN RATE. FOR THIS PROJECT, THE DESIGN <br />INFILTRATION RATE FOR THE FILTRATION BASIN IS 0.8-IN/HR, THUS INFILTRATION TEST <br />RESULTS MUST BE NO LESS THAN 1.6-IN/HR. <br />6. ONCE EXCAVATED TO FINAL GRADE FILTRATION BASIN AREAS SHALL BE INSPECTED TO ENSURE <br />THAT NO SEDIMENT FROM ONGOING CONSTRUCTION ACTIVITY IS REACHING THE BASIN AREAS. <br />ALL FILTRATION BASIN AREAS SHALL BE INSPECTED TO ENSURE THAT UNAUTHORIZED EQUIPMENT <br />IS NOT BEING DRIVEN ACROSS THE BASIN AREAS, AS WELL. <br />7. FINAL STABILIZATION OF THE FILTRATION BASINS SHALL NOT BE COMPLETED UNTIL THE <br />UPSTREAM DRAINAGE AREAS HAVE BEEN STABILIZED. <br />FILTRATION BASIN NOTES: <br />LICENSE NO.: 63480 <br />NORMAN E. STATZ, PE <br />50