Loading...
HomeMy WebLinkAboutPL PACKET 01192021If you would like to request special accommodations or alternative formats, please contact the City Clerk at 612-782-3313 or email city@savmn.com. People who are deaf or hard of hearing can contact us by using 711 Relay. Our Mission is to be a progressive and livable community, a walkable village, which is sustainable, safe and secure. The meeting can be viewed live via cable channel 16 in the North Suburbs or the web broadcast at https://webstreaming.ctv15.org/regionview.php?regionid=64. Due to health concerns and limited seating, we encourage use of virtual option by using this link https://www.savmn.com/Calendar.aspx?EID=1220 There is also a dial-in option available. Members of the public who wish to attend the meeting may do so in person. For those not in attendance, If you wish to submit a comment or question, electronically submit your comments at https://www.savmn.com/FormCenter/Public-Comments-for-City-Meetings-conduc-20/Public- Comments-for-Planning-Commission--95 no later than 5:30 pm on the day of the Planning Commission meeting. Following guidance from state health officials, some commissioners may choose to participate in upcoming meetings electronically pursuant to MN Stat. §13D.021. Call to Order. Pledge of Allegiance. Roll Call. Consideration, discussion, and possible action on all of the following items: I.Approval of the January 19, 2021 Planning Commission Meeting Agenda. (action requested) II.Approval of the December 15, 2020 Regular Planning Commission Meeting Minutes. (action requested) III.Public Hearing. A.Consider a request for a Conditional Use Permit by Culvers restaurant, to allow for a Dynamic Display Electronic Sign at 4004 Silver Lake Road. (pp.13-31) B.Consider a request for a Preliminary Plan stage PUD by Development 65, for construction of a 135 unit full service senior living building on a 4.35 acre site along the eastern edge of Stinson Parkway, between Lowry Avenue and 27th Avenue at 2501 Lowry Avenue. (pp.33-93) IV.Staff Reports. CITY OF SAINT ANTHONY VILLAGE PLANNING COMMISSION MEETING AGENDA JANUARY 19, 2021 COUNCIL CHAMBERS 7:00 PM If you would like to request special accommodations or alternative formats, please contact the City Clerk at 612-782-3313 or email city@savmn.com. People who are deaf or hard of hearing can contact us by using 711 Relay. Our Mission is to be a progressive and livable community, a walkable village, which is sustainable, safe and secure. V. Other Business. A. Motion clarification regarding request for Conditional Use Permit for a car wash facility for Boulevard Autoworks 2701 Kenzie Terrace. (pp.95-167) B. Ordinance amendment discussion of Accessory Building regulations in Zoning Ordinance. (pp.169- 176) VI. Community Forum. Individuals may address the Planning Commission about any City business item not included on the regular agenda. Speakers are requested to come to the podium, sign their name and address on the form at the podium, state their name and address for the Clerk’s record, and limit their remarks to five minutes. Generally, the Planning Commission will not take official action on items discussed at this time, but may typically refer the matter to staff for a future report or direct the matter to be scheduled on an upcoming agenda. VII. Information and Announcements. VIII. Adjournment. CITY OF ST. ANTHONY 1 PLANNING COMMISSION MEETING 2 3 DECEMBER 15, 2020 4 7:00 p.m. 5 6 CALL TO ORDER. 7 8 Chairperson Westrick called the meeting to order at 7:00 p.m. 9 10 PLEDGE OF ALLEGIANCE. 11 12 Chairperson Westrick invited the Commission and the audience to join her in the Pledge of 13 Allegiance. 14 15 ROLL CALL. 16 17 Commissioners Present: Chair Westrick, Commissioners Socha, Neumann, Payne, Rude, 18 Erickson, and Morita. 19 20 Absent: None. 21 22 Also Present: City Planner Stephen Grittman 23 24 I.APPROVAL OF THE DECEMBER 15, 2020, PLANNING COMMISSION MEETING 25 AGENDA. 26 27 Motion by Commissioner Neumann, seconded by Commissioner Payne, to approve the 28 December 15, 2020, Planning Commission agenda. 29 30 Motion carried 7-0. 31 32 II.APPROVAL OF THE SEPTEMBER 15, 2020, REGULAR PLANNING COMMISSION 33 MEETING MINUTES. 34 35 Commissioner Payne indicated he was not present at the September 15, 2020 meeting. 36 37 Motion by Commissioner Neumann, seconded by Commissioner Erickson, to approve the 38 September 15, 2020, Regular Planning Commission Meeting Minutes as corrected. 39 40 Motion carried 7-0. 41 42 III. PUBLIC HEARING.43 44 A.Consider a request for a Conditional Use Permit to construct a single pull-45 through car wash with twelve parking stalls with vacuum stations at the property46 located at 2701 Kenzie Terrace.47 48 1 Planning Commission Regular Meeting Minutes December 15, 2020 Page 2 Chair Westrick reviewed how the public hearing will proceed this evening. This item will 1 come before Council on January 12, 2021. 2 3 Chairperson Westrick opened the public hearing at 7:05 p.m. 4 5 City Planner Grittman reviewed the request for Conditional Use Permit for a car wash located 6 at 2701 Kenzie Terrace. 7 8 Mr. Tom Archambault, owner of Boulevard Auto Works, 2801 Kenzie Terrace, addressed the 9 Commission. 10 11 Mr. John Grotkin, RJ Ryan Construction was at the meeting to answer questions. 12 13 Commissioner Neumann asked if this is the site where there used to be a pig farm with some 14 concerns of toxicity being in the ground. She wondered why the business owner being born 15 and raised in St. Anthony and St. Anthony being so wonderful chose to move his family out 16 and live somewhere else but does business in the City. 17 18 Mr. Tom Archambault explained as it pertains to a pig farm being on that location, they would 19 have to look into site records and history. He noted a Phase One Environmental Investigation 20 has been done and is complete. Boring of the soil with samples taken has been done as well. 21 To his knowledge there are no contaminates there and there does not appear to be any history. 22 He stated to answer the second question, the most honest answer is that in 2015, right after he 23 bought the business, his wife was expecting their second child. They were residents of 24 Columbia Heights because that was an area they could afford to live for the previous ten 25 years. His wife was also born and raised in St. Anthony. When looking to move into a larger 26 home, they looked at houses in St. Anthony but were not able to find any that they could 27 afford. They ended up moving to the neighboring community of Shoreview and have found a 28 nice neighborhood there, similar to what can be found in St. Anthony, to raise their family. 29 He stated the people of St. Anthony have done a wonderful job of creating a great place to live 30 that is very desirable, but his family was not able to afford it. 31 32 Commissioner Socha explained her question had to do with the City Planner’s 33 recommendation for a canopy. She did not love that recommendation because it seems like it 34 will add more visual to look at but aesthetically, sometimes less is more. She asked how 35 noisy are the vacuum stalls that are planned to be installed and what are the owner’s thoughts 36 on a canopy. She thought maybe there could be a requirement added to the number of 37 maximum decibels for noise and the canopy requirement could then be dropped. 38 39 Mr. Tom Archambault explained he did not have the exact decibel rating for the vacuum 40 cleaners themselves. There are decibel ratings available for the blowers that would be used 41 for drying the vehicles and those ratings are at: 10 feet away from the blowers is 90 decibel, 42 20 feet away it goes down to 86 decibels, 50 feet away the decibel is 79 and at 100 feet away 43 the decibel rating is 75. By comparison, if they were to look at what 75 decibel is equivalent 44 to, 75 decibels is equivalent to a vacuum cleaner. He would suspect that 75 decibels would be 45 the proper range, but he could get further information from their equipment provider. 46 2 Planning Commission Regular Meeting Minutes December 15, 2020 Page 3 1 Mr. Tom Archambault stated in regard to the canopy, he agreed with Commissioner Socha 2 that aesthetically less may be more but listening to some of the residents of The Kenzington, 3 owners of the condos, noise is the largest concern and the reason whey they decided to put the 4 entrance of the car wash closest to their building. Then the area where vehicles are dried and 5 exit the building will be the farthest distance between the blowers and their building to 6 mitigate the noise and lower it as much as possible. With staff recommendation of a canopy, 7 he thought it is a very good consideration to act in good faith as a good neighbor. 8 9 Chairperson Westrick asked if there was anyone in the public who would like to address the 10 Commission. 11 12 Mr. Grittman indicated there was no one in the chamber but there where some written 13 submissions from the following public: 14 15 • Ms. Jeanette Fleming, owner at #410, The Kenzington 16 • Mr. Lee John Kurtz, 2601 Kenzie Terrace, Apt. 109, The Kenzington 17 • Mr. Dave Hess, owner at #409, The Kenzington 18 19 Mr. Grittman read the emails into the record. 20 21 Mr. Dave Hess addressed the Commission and indicated he was against the car wash being 22 built. 23 24 Mr. Dave Colling, 2708 27th Avenue, addressed the Commission with concerns about the 25 noise, not necessarily with the car wash itself but from radios playing, people talking, etc. He 26 would also love to see a study done with similar facilities in a residential area and how they 27 have impacted those spaces. 28 29 Ms. Jeanette Fleming addressed the Commission and indicated she was against the car wash 30 being built. Her main concern is going back to the Code Mr. Grittman was quoting in the 31 beginning, Section 152.243c. There was one requirement that is not included in the ten 32 conditions that staff was giving to the Commission to consider, which is Subsection 3. One of 33 the requirements for a Conditional Use Permit; “The use will not be detrimental to the health, 34 safety, or general welfare of persons residing or working in the vicinity or to the values of 35 property in the vicinity.” That particular Subsection was not dealt with at all in the ten 36 conditions and she asked that somehow that be taken into consideration before the CUP is 37 approved. She thought this was an incompatible use for the land. 38 39 Councilmember Walker asked why the owner did not, as a precondition, talk to the residents 40 before even approaching the City to request to install the car washing units because from what 41 he is hearing from the residents, they have a good relationship with the owner. He was 42 thinking from the context of making things simpler, to have a conversation with the residents 43 before it even becomes formal with the City itself. He wondered if this occurred or not. 44 45 3 Planning Commission Regular Meeting Minutes December 15, 2020 Page 4 Mr. Tom Archambault explained they did not have a conversation, when it comes to 1 construction and planning and things of that nature, there are a lot of moving parts and they 2 had to start in one area which was finding out where the property lines were. In that same 3 fashion, they wanted to do soil sampling and a Phase One Environmental Study for the shear 4 fact that if they found things within those reports that deemed the property unbuildable, it 5 would be a moot point and they would not need to have conversation with anybody until they 6 would figure out how to mitigate those issues. Also, for budgetary purposes, if a plan were 7 put together that was unaffordable then they would not need to discuss it. It is not a matter of 8 avoiding the residents there, but they had to start someplace. He explained he does have a 9 good relationship with the residents with The Kensington and many have supported his 10 business for years. He noted they will continue to be a good neighbor and look at the 11 concerns those residents have. 12 13 Ms. Cary Zahrbock, addressed the Commission and shared her concerns about the noise and 14 exhaust. She asked what the hours of operation would be. 15 16 Mr. Tom Archambault explained currently they are looking to have lower hours of operation 17 Monday through Friday, 8am to 5pm. Saturday and Sunday hours would tentatively be the 18 same as Monday through Friday. 19 20 Ms. Fleming asked for confirmation that the car wash would be open seven days for nine 21 hours a day. 22 23 Mr. Tom Archambault indicated that was correct. 24 25 Mr. Steve Baylor indicated he lived at The Kensington and was on the Board of Directors. He 26 asked if there was anything else considered for that piece of property similar to a small 27 grocery store or convenience store rather than a noisy, fumy car wash. 28 29 Mr. Tom Archambault indicated Mr. Baylor and he have had that conversation in the past 30 with his background in the grocery business. But his background is in automotive and he does 31 not know anything about a grocery business. He has heard that residents would like to see a 32 grocery or convenience store there or it turned into a park, but he needed to do what he knew 33 in order to find the most success which is why he looked at a car wash. 34 35 Chairperson Westrick closed the public hearing at 7:52 p.m. 36 37 Commissioner Neumann stated she noticed that the landowner seems to have a very good 38 relationship and a good understanding of what the individuals living in that area are like. 39 Also, to the point of if he owns already an automotive business, it makes sense that he would 40 conveniently put in a car wash nearby. She thought it seemed smart and makes sense. It also 41 would seem there would already be noise from the auto shop along with fumes and gas. She 42 noted regarding noise, lawnmower are louder than what was indicated for vacuums. She 43 noted the first letter that was written and put in the packet, stated this is a community where 44 people are older and those things. She wondered if the writer was talking just about the area 45 where they were living or if they are talking about St. Anthony Village as a whole because she 46 4 Planning Commission Regular Meeting Minutes December 15, 2020 Page 5 has lived in the City since 2006 in various capacities, is in her forties, a person of color, and a 1 black woman of African descent. There are not many of them here, but she thought there has 2 been in increase with a Mosque coming in so more Africans who are new Americans, like 3 herself, have entered the City and are coming in more and more. The point she wanted to 4 make is there was a whole space at Walmart vacated that ended up being leveled for building 5 housing for seniors and there are other places that have car washes that are local around here. 6 However, it seems to her that this gentleman, from the way he is speaking, it does not sound 7 like he is going to be bringing a jenky enterprise in to build something that is going to have all 8 of this noise. 9 10 Commissioner Neumann noted another speaker, Mr. Hess, indicated they have a right to enjoy 11 their property, which she does not disagree. She lives on the Ramsey County side and there is 12 not one day that goes by where she is not getting harassed in her own home. She understands 13 that there are things that happen right where they live that they cannot always have it be 14 exactly how you want, but to block something that might potentially benefit the community as 15 a whole and also serve Northeast Minneapolis, because she owned a house on Lincoln Street, 16 it just seems to be the modus operandi of individuals living in St. Anthony who are coddled, 17 nurtured, sheltered, and for whom the decisions are made to benefit them. Commissioner 18 Neumann stated in her opinion there is just a lot of whining that she did not think was 19 necessary. She noted this is her last meeting. She wanted to thank everyone for these last 20 three years, to speak her peace, and represent individuals who are told they do not live here. 21 22 Commissioner Erickson stated his observation that he could not think of a car wash on a 23 development like this with a car wash building and room for two traffic lanes and several 24 parking spots and vacuum stalls. He asked if they were sure this will all fit on a parcel that is 25 less than an acre. The way he sees the diagram, it looks like the cars that go behind the 26 building and are cued up to enter the car wash, if that line got to be long enough, it may block 27 cars exiting the car wash. He asked if that has been considered as well. 28 29 Mr. Grittman indicated staff was comfortable with what the applicants have shown will fit on 30 the site. He thought the stacking was unique and unusual because normally you would not see 31 stacking like this. In this case, it would be unlikely that the stacking lane would back up into 32 the exit and interfere with that because there are so many available stacking spots. 33 34 Commissioner Payne indicated the car wash he frequents the most in St. Anthony is on the 35 block of 38th and Stinson and it appears that the entrance of that car wash is approximately 36 fifty to one hundred feet from the balconies of The Landings multi-family units in that part of 37 town. He wondered if there has been any type of feedback to the City or the car wash owner 38 about issues with noise because it seems that the two businesses would be similar. 39 40 Mr. Grittman indicated he was not aware of anything from the Code Enforcement 41 Department. 42 43 Commissioner Socha indicated she was quite interested in Ms. Flemings comment about the 44 criteria she quoted and finds it unlikely that property values would drop in half. But the 45 concerns being expressed seemed valid about fumes and radio noises and that would have 46 5 Planning Commission Regular Meeting Minutes December 15, 2020 Page 6 some effect on property value. She noted she looked and confirmed that St. Anthony Code 1 does state “detrimental” and not “unreasonably detrimental” or not “extremely detrimental” so 2 she wondered if there was any further clarification about what “detrimental” means on 3 purposes of when the City Council is supposed to grant a Conditional Use Permit because the 4 if the criteria is just not detrimental at all and detrimental does not have to rise to a certain 5 level, she had a hard time seeing how it would not be detrimental to some effect, to some 6 point on neighboring property values. She was not so sure about health and safety but general 7 use of it, which does affect the property value. 8 9 Mr. Grittman explained the citation referred to means the use will not be detrimental to the 10 health, safety or general welfare of persons residing or working in the vicinity or to the values 11 of property in the vicinity. This is a standard action that is mirroring the State Law related to 12 Zoning in general. It is the standard of review that cities put any zoning question to and 13 typically where a value in property has been an issue there has been a requirement to show 14 actual evidence rather than a concern. It is something the City takes into consideration the 15 best they can, but they would want to have some hard evidence before they would deny an 16 application on that basis. 17 18 Commissioner Socha asked whose burden is it to provide the hard evidence. Mr. Grittman 19 explained the burden would be on the people making the claim of detrimental value. 20 Commissioner Socha asked how burdensome it would be for the City to initiate a study on 21 that. 22 23 Commissioner Neumann expressed that she did not want her property dollars going towards a 24 study on this. Mr. Grittman explained he was not aware of any situation where the City has 25 undertaken, not just St. Anthony, but the City generally has undertaken that kind of a study on 26 its own. He thought it would be somewhat unprecedented in his experience. 27 28 Commissioner Rude stated his take on what Commissioners Socha and Neumann have just 29 commented on, in his read of the materials sent to him, he interpreted it to say that there is a 30 presumption that the use is allowed on properly zoned land. In other words, this is 31 commercially zoned property so the presumption is that a commercial business can be built 32 there. In reading that, it almost seems like their hands are tied and if they can put reasonable 33 limits on it, the City cannot stop them from a commercial building on commercial property. 34 The City can only try to seek some mitigating factors to limit it. He stated this is commercial 35 property and he hated to admit it but if they could build a residential property next to a 36 commercial property there needs to be some expectation of this at some point. 37 38 Commissioner Rude stated in regard to noise and hours of activity, he understood that trucks 39 and moving and garbage trucks are not supposed to be on the roads before 7:00 am. He 40 wondered if there was some limit on sound such as between 7:00 am and 10:00 pm., that 41 would affect the hours of this business to make sure they are at least contained within those 42 time frames. Mr. Grittman believed there are limits to construction traffic and to other types 43 of service traffic. On public roadways there would not be that kind of limitation but on 44 private property, occasionally there are some limitations. He noted he was not able to site 45 those at this time, but it would be his impression that the applicants proposed hours of 46 6 Planning Commission Regular Meeting Minutes December 15, 2020 Page 7 operation would be easily within that limitation, but he would have to check on that specific 1 timing. 2 3 Commissioner Rude asked if there were some sort of Conditional Use Permit issue that could 4 be limiting the hours to certain time periods. He thought that might be a practical solution to 5 the sound issue. 6 7 Commissioner Rude also asked what a permanent canopy is. Mr. Grittman explained that 8 would be something staff would need to resolve with the applicant and would need to meet 9 the City’s typical building standards. Staff’s intent with the language is that it would be 10 constructed in a way that would have the affect of blocking light and mitigating noise out of 11 the site to the west and north. Commissioner Rude suggested making it much like a garbage 12 enclosure and would have to be made out of similar material as the main building. 13 14 Commissioner Rude asked if the applicant would be willing to do all of the recommendations 15 made by City Staff and move the project forward as proposed. 16 17 Mr. Tom Archambault indicated as he looked at the ten criteria from staff, there is not one that 18 seemed to be out of the realm of possibility. The largest change to the design would be the 19 canopy and canopies come for the vacuum stations in many different shapes, forms, and 20 materials. He thought even with that being sort of a larger hurdle, it is not insurmountable, 21 and they would be willing to proceed with the criteria laid out to get this approved. 22 23 Commissioner Rude proposed the Commission add something about the hours of operation 24 and the materials of the canopy if this will be recommended to the City Council. 25 26 Commissioner Morita noted regarding the land use itself, it sounded like this land is approved 27 for a car wash, the car wash itself is not a blocked business and the goal of this 28 recommendation by staff is to help mitigate any of the risks that could impact the homeowners 29 next door. He wondered if that was correct. Mr. Grittman stated he would generally agree 30 with Commissioner Rude’s formulation and although it is not impossible or required to 31 approve it, there is a very high burden on the City where if a CUP is denied the burden is that 32 the City needs to find that the impacts of the use are not mitigatable. This is an eligible use on 33 the site with an understanding that the Commission has the authority and probably the 34 requirement to impose conditions that make it no worse than what a permitted use might be 35 eligible to do on that property. 36 37 Chairperson Westrick indicated Mr. Tom Archambault cited that he is working with his 38 vendor and the vendor makes vacuums at lower decibels. She wondered if this is something 39 being investigated as part of working with his vendor on this. Mr. Tom Archambault 40 indicated it was and as previously stated, they are looking at noise mitigation as it pertains to 41 the blowers and also at it pertains to the vacuum cleaners and will likely select the lowest 42 volume vacuum that they can get. 43 44 Commissioner Socha asked if Mr. Tom Archambault would be objectionable to the 45 Commission adding criteria that limits hours to a specific time of 7:00 am to 10:00 pm, which 46 7 Planning Commission Regular Meeting Minutes December 15, 2020 Page 8 was proposed. She also wondered if there was any objection of the Commission putting in 1 criteria that none of the decibel levels would be over a certain point for any individual item, 2 such as one hundred decibels. Mr. Tom Archambault did not deem it necessary for there to be 3 an addition to hours of operation, considering all of the other commercial businesses within 4 the area operate in longer hours, including his own. If the Commission wanted to put a 5 stipulation on it, he asked that it be longer than what he has already proposed in all fairness, 6 but he was not of the mindset that a Planning Commission or Government body should have 7 to set that standard for them. He stated the second question as it pertained to adding a 8 condition of one hundred decibels per each individual item, if that is added he would like the 9 Commission to provide some research to show that they are not being too stringent and setting 10 a standard that is not obtainable. He noted he could also do that and have his vendor do that 11 as well. 12 13 Commissioner Neumann stated she agreed with Mr. Tom Archambault and thought 14 Commissioner Socha likes to get overly involved with things that have nothing to do with 15 what the Commission is supposed to do here as a Planning Commission from asking about 16 decibels. She asked Commissioner Socha to put herself in her shoes. She stated it is no 17 wonder that nobody wants to come to the City because they get picked at over things that do 18 not really matter and are not really relevant. She indicated Commissioner Socha is a lawyer 19 but did not know how she then becomes an aviation specialist, a builder, etc. This is the stuff 20 that makes these meetings go for longer than they have to. Commissioner Neumann indicated 21 this is her last meeting and she wanted to make sure that everyone hears what she has to say 22 because she is not going to be on the Commission next year to make these comments. She 23 thought it was really unreasonable, a lot of things that Commissioner Socha asks for. She 24 explained Commissioner Socha argues about two inches, three inches, etc. and it is not backed 25 up by anything and now she wants the City to pay for a study because one building is 26 complaining and does not make sense. She stated they need to let this man live. 27 28 Commissioner Socha explained she understood the vacuum cleaners were going to be 75 29 decibels, so she thought imposing the restriction of 100 decibels was proper. She was getting 30 that information from materials that had been presented. This was to clarify where she came 31 up with the suggestion of 100 decibels. 32 33 Commissioner Neumann stated that is not any of the Commission’s business. She asked if 34 Commissioner Socha thought the applicant was really going to put up something that is illegal 35 when he is using a company that does this for a living. She explained she did not understand 36 these questions that get asked that make no darn sense. He is hiring an individual that does 37 this, who has done this at multiple spots, and cares about the people in that building. She 38 asked why did Commissioner Socha want, as a Planning Commission, put all of this stuff in 39 there that limits and restricts the applicant unnecessarily. She indicated she did not 40 understand why Commissioner Socha was asking for a condition with restricted hours unless 41 every other business had that same condition. 42 43 Commissioner Socha explained she was trying to explore different options to mitigate, which 44 is what she understands is what the Commission is tasked with. She stated she was not going 45 to have any more response to her position. 46 8 Planning Commission Regular Meeting Minutes December 15, 2020 Page 9 1 Commissioner Rude stated since he was the one who proposed the sound hours he will speak. 2 The City does limit, for example, commercial traffic, construction work and things like that by 3 hours so they do have that in the City. He was suggesting it be kept the same hours, 7:00 am 4 to 10:00 pm. He noted sound pollution is something that would be a mitigating factor. He 5 also wanted to point out that Ms. Fleming who spoke out, he read her emails and appreciated 6 those as well. He thought one of her comments was there are limits to drive-throughs and the 7 City has denied them in places in the City based on where they would be located but he did 8 not think a car wash would have a speaker that would be disturbing and did not having a 9 bearing on this item, but he wanted to point that out for Ms. Fleming. 10 11 Commissioner Neumann stated the other piece on the Ramsey County side, not only is there a 12 car wash but there is also The Unofficial and there are all sorts of residential properties around 13 there. She did not understand why this particular item is being singled out when the exact 14 same thing exists already in the City over on the Ramsey County side by the St. Anthony 15 Business Center. 16 17 Motion by Commissioner Neumann, seconded by Commissioner Rude, to recommend that the 18 City Council approve a Conditional Use Permit for a car wash facility at 2701 Kenzie Terrace, 19 with the conditions as detailed in the staff report. 20 21 Commissioner Rude indicated he would like to amend the motion to add the hours of 22 operation to be 7:00 am – 10:00 pm and that the canopy match the colors of the building. 23 24 Commissioner Neumann stated a wall or window air conditioner is approximately 85 decibels 25 and each unit at that property has one of these on their balcony. The applicant has already 26 stated he would install a canopy, so she was confused as to why the Commission is asking it 27 to be the color they want. She understood it would have to match the building because it is in 28 the City Code. The area is zoned for commercial and she did not understand why they are 29 discussing other types of businesses when that is not what is being proposed. A City study on 30 behalf of a citizen’s complaint about a hypothetical issue is going to be an undue burden to the 31 other taxpayers. She stated the responsibility for conducting that type of study is on the 32 people complaining and she did not believe it would be an appropriate action for the City to 33 undertake. 34 35 Commissioner Socha stated in response to the current motion which is to approve with the 36 two conditions that Commissioner Rude set forth, she did not support requiring the canopy to 37 match and did not think that was necessary to get that detailed. She also was just exploring 38 the option before of the decibel levels and based on the conversation that has happened and 39 the reassurances from the property owner, she did not think that was necessary. She would 40 support the motion if amended another time to just include the hour limits of 7:00 am to 10:00 41 pm, which is substantially more than what the property owner has proposed he intends to do 42 but provides some assurance that this will not be a 24-hour car wash. She would not support 43 the motion as it stands with the two amendments but would support it with the hour 44 amendment. 45 46 9 Planning Commission Regular Meeting Minutes December 15, 2020 Page 10 Chairperson Westrick reviewed the motion but did not think there was an approval of that 1 amendment made by Commission Rude and would have to be voted on. 2 3 Commissioner Rude withdrew the amendment condition regarding the canopy. 4 5 Commissioner Rude made an amended motion to recommend that the City Council approve a 6 Conditional Use Permit for a car wash facility at 2701 Kenzie Terrace, with the conditions as 7 detailed in the staff report and adding a condition of restricting car wash hours from 7:00 am 8 to 10:00 pm. 9 10 Commissioner Neumann indicated because Commission Rude already seconded her motion 11 he cannot make an amended motion until the first motion is voted on. 12 13 Mr. Grittman stated procedurally there is a motion on the floor that has been seconded. Under 14 the rules somebody could move to amend that motion and that amendment would have to pass 15 or fail and then the Commission could return to the original motion if it fails. 16 17 Substitute motion by Commissioner Rude, seconded by Commissioner Socha, to recommend 18 that the City Council approve a Conditional Use Permit for a car wash facility at 2701 Kenzie 19 Terrace, with the conditions as detailed in the staff report and adding a condition of restricting 20 car wash hours from 7:00 am to 10:00 pm. 21 22 Motion carried 7-0. 23 24 IV. STAFF REPORTS – NONE. 25 26 V. OTHER BUSINESS. 27 28 A. 2021 Planning Commission Work Plan. 29 30 City Planner Steve Grittman reviewed the 2021 Planning Commission Work Plan with the 31 Commission. 32 33 Commissioner Neumann indicated she was abstaining because she will not be on the 34 Commission in 2021. 35 36 Chairperson Westrick thought the lighting and sign discussion should be added. 37 Commissioner Rude agreed. 38 39 The Commission indicated the work plan looked good so consensus was to move forward 40 with the work plan with adding lighting and sign discussion. 41 42 VI. COMMUNITY FORUM – NONE. 43 44 VII. INFORMATION AND ANNOUNCEMENTS – NONE. 45 46 10 Planning Commission Regular Meeting Minutes December 15, 2020 Page 11 Chairperson Westrick thanked Commission Neumann for her service over the last three years. 1 She also believed Commission Payne will no longer be on the Commission as well and she 2 thanked him for his time on the Commission. 3 4 Commissioner Payne indicated this has been a good experience and was leaving because his 5 family is moving to Stillwater. He appreciated the opportunity to be of service to the City and 6 will miss it. 7 8 Commissioner Neumann thanked everyone and stated when she came on the Commission 9 three years ago, it was on the heels of the active fight that was going on with residents being 10 upset about what was going on at Lawry Grove. During that time, she had seen proposals 11 come through, for example, a mural honoring Philando Casteel who was murdered by the St. 12 Anthony Police Department in 2016, and she has seen things that do not look right, fair, or 13 ethical. She has also seen some good things come out of it. 14 15 Commissioner Neumann stated she is not leaving because she is disgruntled, her term is 16 ending and she was not provided with how to renew a term. But she understood why because 17 she does not keep quiet about things such as environmental justice and what is happening in 18 the City because she lives here and cares a lot about the community and there is a large 19 segment of the community that gets ignored, even in these meetings. What she is always 20 hearing and who is being catered to is the “silent majority.” To her, that is a dog a whistle, but 21 a lot people think that is normal language in the City who have a voice. She hoped in these 22 three years she has given voice to the issues that a lot of the residents face communicatively, 23 and she hoped that other people watching this who have views like hers will at least try to 24 apply even if individuals like Mayor Stille will not necessarily want a vote to have them be on 25 the Planning Commission. She thought it was still very important to hear voices that may not 26 agree with what your beliefs are because this is not a ‘Stepford’ community. We are diverse, 27 there are a lot of different people here, and everyone respects a voice unless it is hate speech. 28 29 VIII. ADJOURNMENT. 30 31 Chairperson Westrick adjourned the meeting at 9:00 p.m. 32 33 Respectfully submitted, 34 Sue Osbeck 35 TimeSaver Off Site Secretarial, Inc. 36 11 THIS PAGE LEFT INTENTIONALLY BLANK 12 MEMORANDUM To: St. Anthony Village Planning Commission From: Stephen Grittman, City Planner Date: Planning Commission Regular Meeting for January 19, 2020 NAC File No: 323.01 – 21.01 Request: Request for a Conditional Use Permit for an electronic (digital display) sign for Culver’s at 4004 Silver Lake Road NE. BACKGROUND AND STAFF RECOMMENDATION The applicant is proposing to upgrade an existing ground sign identifying its business location at 4004 Silver Lake Road. The ground sign would be located along the northeast side of the building, adjacent to Silver Lake Rd NE. Because a portion of the sign will include an electronic digital display, the sign requires a Conditional Use Permit pursuant to Section 155.29 of the City’s Sign Ordinance. Based on a review of the proposed sign and the applicable regulations, Planning Staff recommends approval of the CUP request, with conditions related to compliance with code requirements applicable to dynamic display signs. GENERAL INFORMATION Applicant: Springfield Sign Owner: Sweet Cream Prop St Anthony (Steve Sparks) Location: 4004 Silver Lake Road NE Existing Land Use / Retail and Other Commercial / Zoned: C- Commercial District Zoning: Surrounding Land North: Retail and other Commercial / Zoned: C- Commercial District Use / Zoning: East: Single Family Attached / Zoned: R3- Townhomes District South: Retail and other Commercial / Zoned: Planned Unit Development West: Multifamily / Zoned: R4-Multiple Dwellings District Deadline for Agency Complete Application Date: 12-18-20 Action: 60 Days: 02-16-21 Letter Sent: No 120 Days: 04-17-21 13 January 11, 2021 Page 2 ANALYSIS 1. Background The applicant proposes to upgrade ground sign at the subject property along Silver Lake Road NE. The new sign would be located approximately 5 feet 2 inches from the property line along Silver Lake Rd NE, and 2 feet five inches from the property to the north. The plans show an overall sign height of 8 feet, 2 inches. The permanent sign display area is 16.78 square feet, and the proposed electronic message board sign area is proposed to be 11.5 square feet – a total sign area of 28.28 square feet. For ground signs in the C, Commercial District, the relevant requirements are as follows: Maximum Height: 8 feet Setback: 15 feet from street curb Sign Area: 34 square feet per surface (up to 2 surfaces totaling 68 square feet) For Dynamic Displays in the C District, these additional requirements are imposed: Percentage of total sign display area: 35% Minimum duration of continuous image: 5 minutes Transitions: Image changes must be instantaneous, without special effects or gradual transitions Messages: Must be complete with each image, not continuing in context or intent to the next images Color: Must be monochromatic against a solid black background Sign Construction and Maintenance. All permanent freestanding ground signs shall have self- supporting structures erected on and permanently attached to concrete foundations. The base of Dynamic Display signs must maximize the use of natural materials, such as stone, brick, rock 14 January 11, 2021 Page 3 or similar decorative material, in construction and should conform to the material design of the principal structure. In addition to these requirements, there are several operational requirements which are designed to prohibit the impression of video, movement, flashing, scrolling, or similar perceptions of motion. The image must be static for the full 5 minutes (or more). The applicants and owner should be sure to familiarize themselves with the operational requirements, as compliance with these requirements will be a component of the Conditional Use Permit. The proposed sign slightly exceeds the dimensional requirements of code, being 2 inches above the maximum higher of 8 feet. It appears that the height may be an existing condition, and would be presumably legally non-conforming. If this is the case, the applicant should verify that they are not adding to the height of the existing sign. The digital display area, at 11.5 square feet, is 33.8% of the maximum allowable sign area. While the overall sign display area on this site is less than the maximum, the digital portion is compliant with the potential display. As such, staff finds that the proposed digital sign complies with the intent of the code. The locational requirements of the code are met. The sign may be allowed under the CUP, if the applicant reduces the height and the size of the dynamic sign. In summary, the proposed sign does not meet the requirements of the relevant Zoning and Sign Ordinance requirements. 2. Applicable Code Sections. Title XV Land Usage, Chapter 152 Zoning Code, Section 152.253 establishes the process and findings required for consideration of Conditional Use Permits. Title XV Land Usage, Chapter 155 Sign Code, Section §152.29 Dynamic Displays regulates the construction and use of electronic dynamic display signs by Conditional Use Permit, and sets the various performance standards applicable to such signs. CONCLUSION AND RECOMMENDATION Staff recommends approval of the requested Conditional Use Permit for an electronic dynamic display sign at 4004 Silver Lake Road NE with the following conditions: 1. Applicant will submit plans either showing a height of 8 feet, or verifying the existing height of the sign as it currently exists as a “grandfathered” condition. 2. Applicant will submit plans verifying that the dynamic sign accounts for a maximum of no more than 35% of the maximum allowable sign area. 3. Compliance with the operational standards of the code in Section 155.29, notably the requirements for a static, monochrome message of at least 5 minutes duration, and other related requirements. As such, planning staff recommends the following motion: 1. Motion to recommend approval of the Conditional Use Permit application for a dynamic display sign, pursuant to findings related to compliance with the applicable city regulations, conditioned on modifications to the sign, along with ongoing operational practices, that meet the requirements of the sign ordinance. ALTERNATIVE PLANNING COMMISSION ACTION 15 January 11, 2021 Page 4 2. Motion to recommend denial of the CUP. In the event of a recommendation for denial, the Planning Commission must state its findings related to denial on the record. 3. Request Additional Information and Table Action. A motion to table should be accompanied by the specific information requested of staff or the developer necessary to make a recommendation. ATTACHMENTS Exhibit A: Application and Supporting Material 16 Saint Anthony Village Planning Commission 3301 Silver Lake Road Saint Anthony Village, Mn. 55418 Conditional Use Permit Request: An Electronic Message Sign (EMS) Culver’s of Saint Anthony Village 4004 Silver Lake Road Saint Anthony Village, Mn. 55421 Lots 1 & 2, Block 1, Apache Plaza We are requesting a conditional use permit to make an upgrade of signage from a Manual Reader Board (MRB) to an Electronic Message Sign (EMS). We feel the new upgrade will give us a more aesthetical appeal, as well as a more clear and legible message of our services and goods to the public. Our message will also be more legible at a distance to help improve traffic safety. Our sign will also conform to all the regulations set forth in the City Code of Ordinances Title XV,155.29 Dynamic Displays. We are respectfully asking for you to review our requests, see our need, and approve our request. Sincerely, Chris Hampton Springfield Sign 4825 E. Kearney St., Springfield, Mo. 65803, chrish@springfieldsign.com 417-862-2454 17 18 19 20 5'-312" 2'-612"2'-5" LOCATION:NSILVER LAKE ROADCUB FOODS SERVICE ROAD PROPOSED MONUMENT SIGN TO BE UPDATED SCALE 1" = 30'Client: Culver Franchising System, Inc. 540 Water Street Prairie du Sac, WI 53578 p (608) 643-7980Sheet Number:1 OF 1 Project Number: Drawn By: Reviewed By: Date: CLH MW SPRINGFIELD SIGN 4825 E. Kearney St. Springfield, MO 65803 (417) 862-2454 11-18-20 27794 ST. ANTHONY, MN. NEW CULVER'S-SIGNAGE 4004 SILVER LAKE ROAD ST. ANTHONY, MN. 55421 SIGN PLACEMENT PLAN CULVER FRANCHISING SYSTEM, INC. 21 SIGN PACKAGE PROPOSAL Culver’s of St. Anthony, MN RE-IMAGE PRESENTED TO: 10/14/20 - Preliminary 10/20/20 - Revision - EMC change 10/23/20 - Revision - Size Change to Monument 10/26/20 - Revision - Dimension Change 11/02/20 - Revision - Cap removal 11/13/20 - Revision - Monument change to ME-27 12/21/20 - Revision - Change EMC to Amber Monochromatic 12/21/20 - Revision - EMC Size change DATE PREPARED: 2019 Springfield Sign & Graphics Inc., Springfield Sign 22 NOTES SITE SURVEY INFO MONUMENT MONUMENT RE-IMAGE ST. ANTHONY, MN *SCALE AND COLORS NOT REPRESENTATIVE FROM EMAIL ATTACHMENTS *ALL MEASUREMENTS ARE APPROXIMATE SCALE: 3/8” = 1’ Culver’s sign cabinet of aluminum construction and internally illuminated with LED’s Watchfire RGB full color Electronic Message Center (EMC) with RF wireless communication Amber EMC option available Culver’s Oval is 3M Panaflex faces with 3M HP vinyl decoration UL marked product Broadband communication option available NOTES OVAL: 60.00” X 99.00” = 32.40 SF (MATH.) EMC: 29.00” X 75.00” = 15.10 SF PATTERN EXISTING:YES SITE SURVEY RECEIVED: Proposed Signage EXISTING SCALE: N.T.S. NO SCOPE OF WORK: SITE SURVEY INFO FIELD VERIFIED SURVEY EXISTING: - REFACE EXISTING UPPER CULVER’S OVAL CABINET NO DATE SURVEY RECEIVED: SALES PERSON: MARK WESSELL AO: 27794 DESIGNED BY: J KROEGER T:\o27794 - Culver_s of St. Anthony_ MN _214 (1558)\Art T h i s i s a n a r t i s t i c r e n d i t i o n a n d f i n a l c o l o r s / s i z e s m a y v a r y f r o m t h a t d e p i c t e d h e r e i n . This drawing is Copyrighted material, it remains the property of Springfield Sign & Graphics Inc. unless otherwise agreed upon in writing. It is unlawful to use this drawing for bidding purposes, nor can it be reproduces, copied or used in the production of a sign without written permission from Springfield Sign. 2019 Springfield Sign & Graphics Inc., Springfield Sign SIZING IS APPROXIMATE SITE SURVEY REQUIRED - REPLACE EXISTING MRB WITH EMC NIGHT VIEW SCALE: N.T.S.29”7’-0.5” OVAL 6’-0” EMC 8’ 2” O.A.H. APPROX.SUNDAES -MONUMENT CANNOT EXCEED EXISTING HEIGHT. -LETTER HEIGHT MUST BE AT LEAST 9” TALL. -EMC SQUARE FOOTAGE: 2’x5’-9”=11.5 SF. -OVAL SQUARE FOOTAGE IS 16.78 SF. -AMBER COLOR. -CHANGE WILL BE INSTANTANEOUS. -BRIGHTNESS SHALL NOT EXCEED A MAX ILLUM. OF 4,500 NITS DURING DAYLIGHT HOURS. MAX 450 NITS BETWEEN DUSK/DAWN, AS MEASURED FROM THE SIGNS FACE AT MAX BRIGHTNESS. DATE CREATED / REVISION HISTORY 10/14/20 - NEW 10/20/20 - REV1-EMC Change 10/23/20 - REV2 - Size Change 10/26/20 - REV3- Dimension edit 11/2/20 - REV4- Cap removal 11/13/20 - REV5 - Monument change 12/21/20-REV6-Change to Amber EMC 12/21/20 - REV7 - EMC size change SUNDAES -MUST BE EQUIPPED WITH A DIMMER CONTROL OR MECHANISM TO AUTO CONTROL THE SIGNS BRIGHTNESS TO COMPLY WITH REQUIREMENTS. -HOLD TIME IS 5 MINUTES. 23 THIS PAGE LEFT INTENTIONALLY BLANK 24 PLANNING COMMISSION JANUARY 19, 2021 4004 Silver Lake Road NE Culvers: Dynamic Display Sign Conditional Use Permit DYNAMIC DISPLAY CUP -SITE LOCATION 25 DYNAMIC DISPLAY CUP –AERIAL PHOTO DYNAMIC DISPLAY CUP –SIGN ILLUSTRATION 26 DYNAMIC DISPLAY CUP –REVIEW SUMMARY DYNAMIC DISPLAY CUP –PLANNING COMMISSION ACTION Motion to recommend approval of the request for CUP at 4004 Silver Lake Road N, with the following conditions: 1.Applicant will submit plans either showing a height of 8 feet, or verifying the existing height of the sign as it currently exists as a “grandfathered” condition. 2.Applicant will verify that the dynamic sign accounts for a maximum of no more than 35% of the maximum allowable sign area. 3.Compliance with the operational standards of the code in Section 155.29, notably the requirements for a static, monochrome message of at least 5 minutes duration, and other related requirements. 27 THIS PAGE LEFT INTENTIONALLY BLANK 28 CITY OF SAINT ANTHONY VILLAGE HENNEPIN COUNTY, MINNESOTA RESOLUTION NO. _____________ A RESOLUTION APPROVING A REQUEST FOR A CONDITIONAL USE PERMIT FOR AN ELECTRONIC DYNAMIC DISPLAY SIGN AT 4004 SILVER LAKE ROAD IN THE “C”, COMMERCIAL ZONING DISTRICT WHEREAS, the City of St. Anthony Village received a request from Springfield Sign on behalf of Culver’s for a ground sign with an electronic dynamic display at 4004 Silver Lake Road; and WHEREAS, the property consists of approximately .92 acres and is located in the “C”, Commercial Zoning District; and WHEREAS, the subject parcel is currently developed with a restaurant building; and WHEREAS, such electronic digital display signs are allowed by Conditional Use Permit in the Commercial District; and WHEREAS, subject to verification, the proposed sign is consistent with the requirements of the Sign Ordinance with regard to size, setback and other standards, or will be made so pursuant to City approval; and WHEREAS, the sign can be constructed to be consistent with the materials standards required by the Sign Ordinance related to such signs; and WHEREAS, the Planning Commission has considered all of the comments and the staff report, which are incorporated by reference into the resolution; and WHEREAS, the Planning Commission held a public hearing on January 19, 2021 on the application and the applicant and members of the public were provided the opportunity to present information to the Planning Commission; and WHEREAS, the Planning Commission recommended approval of the Conditional Use Permit with the conditions noted in the Staff report, and as listed below; and WHEREAS, the City Council makes the following findings of fact in support of the resolution for approval: 1. The property is located in an area of commercial land use on a collector roadway. 2. The proposed sign is reasonably consistent with the character of the neighborhood in which it is located. 3. The dimensional requirements of the City’s Sign Ordinance can be met by the proposed application as modified. 4. With the modification or verification of the size under conditions as recommended by the Planning Commission, the proposed improvements constitute a reasonable use of the property. 5. The operational aspects of the City’s Sign Ordinance can be met on an ongoing basis by the owner/operator of the sign. 29 6. The proposed sign, constructed and operated within the requirements of the Code, will not adversely impact surrounding property or public areas. NOW THEREFORE MAY IT BE RESOVLED, that the City Council of the City of St. Anthony Village accepts the findings and recommendations documented in the staff report and approves Conditional Use Permit for a dynamic display sign as shown on the plans submitted on or before December 18, 2021, at 4004 Silver Lake Road, with the following conditions: 1. Applicant will submit plans either showing a height of 8 feet, or verifying the existing height of the sign as it currently exists as a “grandfathered” condition. 2. Applicant will submit plans verifying that the dynamic sign accounts for a maximum of no more than 35% of the total sign area. 3. Compliance with the operational standards of the code in Section 155.29, notably the requirements for a static, monochrome message of at least 5 minutes duration, and other related requirements. Passed in regular session of the City Council on the ___ day of _________, 2021. ____________________________________ Randy Stille, Mayor ATTEST:____________________________ Nicole Miller, City Clerk Review for Administration: ____________________________________ Charlie Yunker, Interim City Manager 30 Name Address Address NOTICE OF A PUBLIC HEARING January 19, 2021, 7:00 p.m. City Hall, 3301 Silver Lake Road, St. Anthony, MN 55418 Notice is hereby given that the City of Saint Anthony Village Planning Commission will hold a public hearing to solicit public response to a proposed Conditional Use Permit by Culvers restaurant, to allow for a Dynamic Display Electronic Sign at the property located at 4004 Silver Lake Road. The Planning Commission agenda and packet item relating to this application will be made available prior to the meeting online at www.savmn.com. Ways to Comment: Online Those persons having an interest are encouraged to attend via Zoom. The link to participate via Zoom can be found at http://www.savmn.com/Calendar.aspx?EID=1220 In Person The public is welcome to attend in person at the City of Saint Anthony Community Center, 3301 Silver Lake Road, in the Council Chambers at 7:00 p.m. Please note seating is limited due to the pandemic. Written Written comments may be taken at the St. Anthony Village City Hall, 3301 Silver Lake Road, St. Anthony Village, Minnesota 55418 until the date of the public hearing. Comments can also be conveyed via email, to planner@savmn.com until the date of the public hearing. Questions? Questions may be directed to the City Planner at 763-957-1100. The Planning Commission will make a recommendation regarding the proposed request to the City Council for their meeting to be held on February 9, 2021 at 7:00 p.m. at City Hall. Steve Grittman City Planner 31 THIS PAGE LEFT INTENTIONALLY BLANK 32 MEMORANDUM To: St. Anthony Village Planning Commission From: Stephen Grittman, City Planner Date: Planning Commission Meeting – January 19, 2021 NAC Project No. 323.01 – 20.19 Request: Request for a Preliminary Plan Planned Unit Development for a Senior Housing Project Property Address: 2501 Lowry Avenue NE Property PID: 07-029-23-23-0001 (part) STAFF RECOMMENDATION Staff has reviewed the project for land use compliance with the intent and policies of the City’s Comprehensive Plan, and for zoning consistency with the R-4, Multiple Family Residential District as a baseline. In summary, the Comprehensive Plan promotes use of the subject property for high density multiple family residential uses of up to 40 units per acre as allowable in this area. The applicant is seeking the PUD, consisting of up to 155 units of “aging-in-place” senior housing on 4.25 acres, a density of 36.24 units per acre. The site plan also relies on a shared driveway with the Urban Grove Manufacture Home Park, extending from the east side of the building to Kenzie Terrace on the south. That shared driveway (approximately .5 acres in area), would have the effect of reducing overall density to approximately 32 units per acre if including in the subject property total. The proposed PUD meets the requirements of the Zoning Ordinance for the majority of the baseline standards. The principal areas of flexibility under the PUD include: (1) Building height (code is 35 feet/3 stories); applicant proposes approximately 56 feet to top of parapet and 4 stories. (2) Lot coverage/impervious surface (R-4 code limits this to 50%); applicant’s proposal is approximately 50.5%. (3) Density (R-4 code limits this to approximately 24 units per acre, Comprehensive Plan calls for 20-40 units per acre); applicant is proposing approximately 32 - 36 units per acre. 33 January 19, 2021 Page 2 Staff believes that the flexibility requested under the PUD is appropriate, given the objectives of the Comprehensive Plan and the related improvements and amenities proposed as part of the project. Staff is recommending approval of the Preliminary Plan stage of the PUD Amendment for St. Anthony Village Senior Housing at 2501 Lowry Avenue NE, with a series of conditions as noted in the summary section below. GENERAL INFORMATION Applicant: Robert Wall – Development 65, LLC Owner: The Village, LLC Location: 2501 Lowry Avenue NE Existing Land Use Vacant (former manufactured home park) Zoning: R-1, Single Family Residential Surrounding Land North: R-1, Single Family Residential Use / Zoning: East: R-1, Manufactured Home Park (under development) South: C, Commercial (Bank/Office Building) West: Mixed Residential (City of Minneapolis) Deadline for Agency Application Complete Date: December 17, 2020 Action: 60 Days: February 15, 2021 Letter Sent: NA 120 Days: April 16, 2021 1. Background The applicant is proposing to redevelop a 4.25 acre portion of the former Urban Grove manufactured home park property with a senior-living multiple family residential project of up to 155 dwelling units. The property was recently approved by City Council for subdivision from the larger Urban Grove property. The development parcels in question are shown on the zoning map below. The unit count is variably identified as 153, 154, or 155 units in the submittals – the applicant should finalize the unit count as a part of the public hearing process. The project is proposed to be developed in a single phase. The project had undergone a Concept PUD review with the City Council and Planning Commission in January of 2020, at the time, a 125 unit project. Upon the withdrawal of the developer from the potential housing project on the Bremer Bank site to the south, the applicant has redesigned the proposal to add nearly 30 additional units, but on essentially the same property. The facility is proposed to include, initially, 89 independent living units, 42 assisted living units, and 24 memory care units – as shown on the floor-by-floor plans submitted with the application, a total of 155 units. As noted, other narrative material refers to 153 or 154 units. In staff’s experience, it is not uncommon that these facilities shift between assisted and independent living status, based on the needs of the individual tenants. 34 January 19, 2021 Page 3 Within the apartment building, a range of unit types are to be provided. The independent living units are broken down into the following unit sizes: • 11 studio units, from 434 to 804 square feet, • 38 one-bedroom units from 651 to 754 square feet, • 22 one-bedroom plus den units 942 square feet, and • 18 two-bedroom units from 1,127 to 1,226 square feet. The site is currently zoned R-1, Single Family Residential, as noted previously. The consideration of a Planned Unit Development for this project would include a rezoning to PUD zoning district, and adoption of a PUD ordinance limiting the use of the property to the approved site plan, building plan, density, and related facilities. 2. Analysis Planned Unit Development Purpose. The applicant wishes to establish a PUD, Planned Unit Development zoning district to accommodate the proposed apartment project. For PUD applications, it is important that the purpose of planned unit development be considered and that a determination is made that this purpose will be fulfilled. Generally speaking, planned unit development is intended to allow a mixture of uses and/or flexibility from the strict terms of the Zoning Ordinance in return for higher site and building design standards than what would otherwise be allowed or required. 35 January 19, 2021 Page 4 Section 152.202 of the Zoning Ordinance specifically states that planned unit development may allow the following: (A) Variety. Within a comprehensive site design concept, a mixture of land uses, housing types and densities; (B) Sensitivity. Through the departure from the strict application of required setbacks, yard areas, lot sizes, minimum house sizes, minimum requirements, and other performance standards associated with traditional zoning, a PUD can maximize the development potential of land while remaining sensitive to its unique and valuable natural characteristics; (C) Efficiency. The consolidation of areas for recreation and reductions in street lengths and other utility-related expenses; (D) Density transfer. The project density may be clustered, basing density on a number of units per acre in place of specific lot dimensions; and (E) District integration. The combination of uses which are allowed in separate zoning districts such as: 1. Mixed residential uses to allow both densities and unit types to be varied within the project; 2. Mixed residential uses with increased density based upon the greater sensitivity of PUD projects to regulation; and 3. Mixed land uses with the integration of compatible land uses within the project. Processing. To accommodate the requested PUD amendment, a two-stage review process will take place. In this regard, the application under consideration is the Preliminary PUD Plan stage. Generally speaking, Preliminary Plan approval is similar to a basic rezoning in that it establishes that the proposed use is appropriate for the subject site. Also, as part of Preliminary Plan review, various conditions of approval are typically imposed. The Preliminary Plan will be subject to a public hearing, review and recommendation by the Planning Commission and consideration of approval by the City Council. The second stage is the Final PUD Plan which basically serves to implement the various conditions of Preliminary Plan approval and ensure that such conditions have been satisfied. The Final Plan is reviewed by the City Council for adoption as an ordinance. No public hearing is required for Final Plan. Comprehensive Plan. The City’s 2040 Comprehensive was adopted last year. The Metropolitan Council has classified St. Anthony Village as an “urban community.” “Urban communities” are expected to plan for forecasted population and household growth at average densities of at least 10 units per acre for new development and redevelopment. In addition, “urban communities” are expected to target opportunities for intensive development near regional transit investments. The City’s 2040 Comprehensive Plan identifies the subject property as an important redevelopment opportunity. Recognizing that the City is expected to accommodate an increase in population and that little to no vacant land presently exists, redevelopment of previously 36 January 19, 2021 Page 5 developed sites is considered the primary means of achieving the City’s residential density objectives. The Land Use Plan included in the 2040 Comprehensive Plan high density development on the subject property. The 2040 Comprehensive Plan also establishes a desired density range of 20 to 40 units per acre for high density residential development. The applicant has proposed a residential density of 32 - 36 units per acre (154 dwelling units/4.25 acres) which is within the density range directed by the draft 2040 Plan. With the preceding in mind, the proposed redevelopment project is considered consistent with the City’s 2040 Comprehensive Plan. With regard to planned housing and affordability, the Metropolitan Council assigned (as a part of the 2040 Plan Update process) an allocation for 152 additional “affordable” units to St. Anthony for the 2021-2030 decade. The Plan accommodates this allocation with land designated for residential development that could support “affordable” housing of more than 460 units. This measurement accounts for land that is available for development at densities of more than 8 units per acre, according to Metropolitan Council definition. Planning staff would note that while rent ranges for the proposed project are not considered in this calculation, not every project will meet every goal of the Comprehensive Plan. The primary goals met by this project would include compatible redevelopment of the subject property, and attention to supporting park-like development along the Stinson Parkway frontage in the City. Land Use Compatibility. In consideration of the proposed apartment building project, a determination should be made that the proposed use is compatible with surrounding uses. Land uses which surround the subject site include the Urban Grove manufactured home park (along Kenzie Terrace NE), single family residential neighborhoods to the north, office- commercial to the south, and mixed single family residential in Minneapolis to the west (homestead and non-homestead). Just east of the manufactured home park is additional senior housing and other multiple family on either side of Kenzie Terrace. The primary potential conflicts raised by this type of housing would relate to building massing in the areas adjoining the lower density small-structure neighborhoods. The applicants have addressed this issue by setting the building back from Stinson Parkway nearly 90 feet, and minimizing the paved parking areas from the front yard space. The face of the building is approximately 220 feet from the faces of the residential buildings line the west side of Stinson Parkway. The nearest parking/drive aisle is approximately 25 feet from the front property line, 35 feet from the public sidewalk, and 60 feet from the nearest drive lane of Stinson Parkway. Typical front setbacks in the R-4 District would be 30 feet at minimum. To the north (also single family), the building setback is approximately 110 feet from the north property line, which is the south boundary of the alley serving those properties. The building 37 January 19, 2021 Page 6 would be approximately 135 feet to the south edge of the garages adjoining the alley, and approximately 240 feet or more to the nearest wall of the residential structures themselves. The applicants have proposed a grass-pave emergency drive access along the north front of the building to a point adjoining the alley and the rear parking area, an employee parking lot of 20 spaces. The employee lot accesses the shared drive, and would utilize the Kenzie Terrace access point to the south. No traffic is able to use the alley, with exception of emergency vehicle use which would need to navigate a gated access restriction, again via grass pave surface. Site Access. Front door access the property is planned for the existing curb cut from Stinson Boulevard. The driveway serves a covered front entry canopy area, with guest parking arrayed around the recessed area. This drive then also accesses a parking area of 16 spaces in front of the south wing, then provides access to the underground parking garage. From this point, the driveway continues to the east to join the shared driveway leading to Kenzie Terrace. From the rear shared private road, access is available to the northerly employee parking area, as well as the loading location for food service deliveries. The applicants have indicated that trash handling equipment will be located in the underground garage, with access to the equipment a part of the design of the garage entry. Access-related issues should be subject to further comment and recommendation by the City Engineer. Setbacks. The PUD zoning district does not impose specific structure setback requirements. For reference purposes however, the following table illustrates setback requirements imposed in the City’s R-4 Multiple Family Residential zoning district (commonly applied to high density residential housing projects) and setbacks proposed by the applicant: R-4 District Setback Proposed Setback Front Yard 30 feet 90 feet Side Yard 15 feet 110 feet (north) 110 feet (south) Rear Yard 40 feet or 20 % of the lot depth, whichever is greater 55 feet+ As shown above, the proposed structure setbacks meet or exceed the requirements imposed in the City’s R-4 District. Recognizing that the site is bordered on the north and west by single family, and to the south by commercial uses, shadows cast on adjacent properties (from the five story buildings) are not expected to have impacts on those properties. For these reasons, it is the opinion of staff that the proposed structure setbacks are acceptable. Existing and proposed tree height will already create greater shadow impacts than the building at these setbacks. 38 January 19, 2021 Page 7 Off-Street Parking Supply. According to the Zoning Ordinance, apartments must provide one off-street space per three units. For the 155 units, the minimum requirement would be 52 spaces. The applicants have provided this count as surface parking, and provided an additional 99 spaces underground. For senior facilities, a large number of the tenants will not drive or have automobiles. None of the memory care tenants will have cars, and typically, fewer than 20% of the assisted living tenants will keep automobiles – even though fewer than this number will drive in any case. For independent living tenants, a maximum automobile count of one space per unit is more than enough, according to most data. As such, we would expect a tenant utilization of parking of about 100 parking spaces, with another 30 spaces needed for maximum shift staff. The proposed plan exceeds this count, at 151 spaces total. The applicants have also provided a “proof of parking” area in the front of the north wing with an additional 20 parking spaces if needed. Presuming that these spaces are not needed, the area is covered with grass pave to maintain a green and pervious appearance in lieu of unused pavement. If this area is needed for some reason, the City or the applicant could initiate an amendment to add this parking to the supply. Building Height. The structure consists of a below-ground level parking garage and four floors above the garage. The building is four stories in height (46 feet to the top of the parapet). The only garage exposure is at the entrance, which is graded to a point below ground, and not visible from surrounding public or residential areas. While the PUD zoning district does not impose a specific height requirement and can provide for “flexibility” in this regard, it is important to note that the City’ R-4, Multiple Family Residential District imposes a maximum height requirement of 3 stories or 35 feet. As a condition of Preliminary PUD approval, findings should be made by City Officials that the proposed four-story building height is acceptable as component of a project which meets the intent of the City’s PUD requirements in consideration of other aspects of the project. Emergency Vehicle Access. As a part of the review process, emergency services (fire and police) have reviewed the project and made a finding that proper emergency vehicle access and hydrant availability is provided. Building plans will be evaluated when submitted. In similar applications, staff will take considerations of such items as key box locations, address markings, and fire lane designations, among other items, at that time. As a part of Final PUD approval, the submitted development plans should be subject to review and comment by the Fire Chief. Building Materials. According to the submitted building elevations, the apartment buildings are to be finished in a variety of materials including the following: • Tan brick encompassing ground level, and portions of the second level • Grey shake siding 39 January 19, 2021 Page 8 • Medium grey and beige cement board siding • Glass Balconies appear to be constructed of metal railing materials. The applicant suggests that the materials are intended to reflect colors found in the area, including the St. Charles Borromeo Church, one block to the north. Landscaping. The applicant has provided a landscaping plan that emphasizes tree plantings in perimeter site locations, with shrub planting areas around the building in rock mulch planting areas. Tree planting along Stinson Parkway includes a variety of (mostly) deciduous over- and under-story tree planting in the front yard space between the parking areas and the property line. Existing tree planting in the boulevard space between the sidewalk and the travel lanes is a part of the Parkway improvements, as well as significant tree planting in the median. One addition to the landscaping plan should be large evergreen plantings at the north end of the shared driveway to screen headlight glare from north-bound employee traffic from affecting the residential area to the north. Because these facilities have staff changes around the clock, this glare could have an impact at certain times. Sidewalks, Parks, and Open Space. The submitted site plan illustrates concrete sidewalks along the south, east and west sides of the site. Sidewalks are also illustrated within the interior court area. The City Engineer has noted that those sidewalks should be shown as 6 feet in width to match existing improvements in the area. The site establishes an impervious surface coverage of 50.05% of the development property. The resulting impervious only slightly exceeds the R-4 standard. The applicant has provided a stormwater management plan which has been reviewed by the City Engineer to ensure appropriate drainage control to meet the City’s objectives of flood management in this area. The facility will be subject to a park dedication requirement which will be detailed as a part of the development agreement.. Lighting. The applicants have submitted a lighting plan that shows a series of 25 foot poles with down-cast fixtures along the front area of the building, and other limited illumination of the site. Footcandle readings at the perimeter are typically less than 0.5 footcandles, and 0.1 at the alley. Signage. The Preliminary PUD application does not appear to include any information related to signage. As a condition of Final PUD approval, a sign plan must be submitted which demonstrates compliance with applicable City sign requirements. Trash Handling. As noted above, trash equipment will be located within the garage level. 40 January 19, 2021 Page 9 Grading, Drainage, and Utilities. Issues related to grading, drainage and utilities should be subject to comment and recommendation by the City Engineer. The City Engineer has reviewed the project at Preliminary Plan stage, and has identified review comments related to civil plans will require technical comment and attention, but none that appear to impact the Preliminary Plan documents or the general site planning. PUD Agreement. As a condition of Final PUD approval, the applicant will be required to enter into a PUD agreement with the City and post all the necessary securities required by it. 3. Criteria for and Consistency with Criteria for PUD Approval. Title XV Land Usage, Chapter 152 Zoning Code, Section §152.209. SUMMARY AND STAFF/PLANNING COMMISSION RECOMMENDATIONS Preliminary Plan PUD - Staff recommends approval with the following conditions: 1. An access easement shall be in place to accommodate the easterly shared access road with the Urban Grove development site to Kenzie Terrace. Proof of such access easement shall be provided to the City as a part of the final PUD documentation. 2. Access-related issues shall be subject to comment and recommendation by the City Engineer. 3. The City finds that the proposed parking supply is adequate to serve the facility. 4. Final PUD Plans demonstrate compliance with ADA parking supply requirements (for disabled persons). 5. City Officials find the proposed four-story apartment building heights to be acceptable (within the context of the PUD). 6. As a part of the Final Plan submission, the submitted landscape plan be amended to add evergreen plantings along the north edge of the shared driveway. 7. As part of the Final PUD Plan submission, a signage plan be submitted for review which demonstrates compliance with City requirements. 8. Issues related to grading, drainage and utilities shall be subject to comment and recommendation by the City Engineer. 9. The applicant enter into a PUD agreement with the City and post all the necessary securities required by it. 41 January 19, 2021 Page 10 10. Consideration of comments of other City Staff. This recommendation is based on a finding that the proposal, with the conditions cited, is consistent with the requirements for PUD consideration, with the long-term objectives of the recommendations and policies of the St. Anthony Comprehensive Plan. ATTACHMENTS Exhibit A: Location map Exhibit B: Application and Supporting Material Exhibit C: Draft resolution 42 kaas wilson architects St Anthony Village - Senior Cover Page ST ANTHONY VILLAGE SENIOR LIVING Parking Schedule Type Count Level -1 91 91 Level 1 51 51 142 Total Gross Area Level Area Level 4 34,793 ft² Level 3 34,756 ft² Level 2 33,961 ft² Level 1 38,760 ft² Level -1 39,304 ft² Grand total 181,574 ft² MEMORY CARE • 24 UNITS • (24) Studios ASSISTED LIVING • 28 UNITS • (15) Studios • (13) 1 Bedroom INDEPENDENT LIVING • 83 UNITS • (37) 1 Bedroom • (34) 1+Den • (12) 2 Bedroom Residential Unit Mix Name Count Unit Gross Area ADA Type AL Unit 0-0 6 434 ft²AL Studio AL Unit 0-1 9 508 ft²AL Studio AL Unit 1-0 3 696 ft²AL 1BR AL Unit 1-1 4 651 ft²AL 1BR AL Unit 1-2 3 694 ft²AL 1BR AL Unit 1-3 3 726 ft²AL 1BR IL Unit 1-0 11 726 ft²1BR IL Unit 1-1 5 687 ft²1BR IL Unit 1-2 10 651 ft²1BR IL Unit 1-5 3 763 ft²1BR IL Unit 1-6 2 640 ft²1BR IL Unit 1-8 6 719 ft²1BR IL Unit 2-0 22 943 ft²1BR+D IL Unit 2-1 3 1,071 ft²1BR +D IL Unit 2-2 4 915 ft²1BR+D IL Unit 2-3 2 865 ft²1BR+D IL Unit 2-4 3 857 ft²1BR+D IL Unit 3-1 4 1,212 ft²2BR IL Unit 3-2 8 1,177 ft²2BR MC Unit 0-1 10 429 ft²MC Studio MC Unit 0-2 11 508 ft²MC Studio MC Unit 0-3 1 477 ft²MC Studio MC Unit 1-1 2 599 ft²MC Studio Grand total: 135 135 43 N 0°06'35" W 311.63N 0°06'35" W 225.45L = 3 0 9 .8 9 R =8 5 1 .7 3 =2 0 °5 0 '4 7 "5101 05510S A N IT A R Y S E W E R E A S E M E N T P E R D O C . N O . 2 7 9 4 3 3 5 C E N T E R L I N E O F S T A T E H I G H W A Y N O . 6 3 A N D S T . A N T H O N Y A N D T A Y L O R S F A L L S R O A D N O R T HE R LY LI N E O F S T A T E H I GH W A Y N O . 6 3 P E R F I N A L C E R T I F I C A T E N O . 1 6 5 2 5 0 0 (F O R ME R L Y K N O WN A S S T A T E H I G H W A Y N O . 6 3 A N D S T . A N T H O N Y A N D T A Y L O R F A L L S R O A D )4' WOOD FENCESTINSON PKWY.K E N Z I E T E R R A CE (C O . R D . N O . 1 5 3 ) 24" 15" 7" 10" 15" 16" 16" 16" 16" 16" 2-8" 28" 14" 14" 2-10" 14" 12" 14" 18" 7" RIM=929.61 INV W=922.5 VERIFY SIZE AND LOCATION 8" STEEL GUYSEMIPHORE SIGN 0.90BENCHMARK: TOP NUT OF HYDRANT ELEV.= 935.34 FEET ST BENCH PK F L A G P O L E SS H H H WV WV WV WV WV S S ST ST ST ST ST ST ST ST ST ST GV ST WV S DYH16'GATED FIRE DEPT ACCESS FROM ALLEY ONLY BIKE RACK PROOF OF PARKING (20 STALLS)122'-0" TRANSFORMER 4-STORY SENIOR LIVING BUILDINGSTINSON BLVDSTINSON BLVDMC GARDEN DINING PATIO52 SURFACE STALLS92 UNDERGROUND STALLSSTORMWATER POND STORMWATER POND RETAINING WALL490'-0"62'-0" kaas wilson architects St Anthony Village - Senior Site Plan 1" = 60'-0"1 Site Plan URBAN GROUP COMMUNITY BUILDING N Parking Schedule Type Count Level -1 91 91 Level 1 51 51 142 44 REF. .. .. SD_1275 SD_126 6 SD_126 7 SD_126 4 SD_1273 SD_127 2 SD_1271 SD_126 2 SD_126 1 MAU 674 ft² Staff 351 ft² Mechanical Room 1 2 23 15 14 13 80 76 75 73 29 30 33 35 27 88 87 86 85 5 6 7 89 12 11 10 72 70 69 68 67 65 64 39 40 41 42 43 44 45 46 50 51 52 37 38 9 84 66 54 55 56 57 63 62 36 1,883 ft² Resident STO EXHAUST STAIR 8 81 34 Bike Storage SD_126 5 SD_127 4 Restroom SD_126 3 18 19 20 21 22 53 47 48 49 59 60 61 79 83 26 90 91 3 4 92 71 74 STAIR 32 54 LOCKERS @ 4'x5' (~42 @ 5'x5') 362 ft² Building Sto 554 ft² Maintenace RM 16 17 24 25 31 58 77 78 82 STAIRELEV LOBBY TRASH ELEV LOBBY TRASH490'-0"71'-4" 146'-8" Schema 1 Legend 1BR 1BR+D 2BR Circulation Commons Core MC Studio 972 ft² Lobby 1,018 ft² AL Dining 2,164 ft² Kitchen 3,116 ft² IL Dining 1,290 ft² Mail Cafe 1,196 ft² MC Lounge 437 ft² Bistro 1,131 ft² MC Dining FIRE WALL OUTDOOR PATIO MEMORY CARE GARDEN 347 ft² Pvt. Dining PARCEL RRNURSE SUITECLUB ROOM TRASH IT OFFICE OFFICE OFFICE OFFICE WORK RM CONF. OFFICE RECEPTION ELEV. LOBBY Elec/LV JAN. CLOSET LAUNDRY STAIR STAIR STAIR kaas wilson architects St Anthony Village - Senior Level -1 & Level 1 1/32" = 1'-0"1 Level -1 1/32" = 1'-0"2 Level 1 Unit Mix by Floor Name Unit Type Count Area Level Total Area Level 1 IL Unit 1-0 1BR 1 726 ft² Level 1 726 ft² IL Unit 1-5 1BR 1 763 ft² Level 1 763 ft² IL Unit 2-0 1BR+D 1 943 ft² Level 1 943 ft² IL Unit 2-2 1BR+D 1 915 ft² Level 1 915 ft² IL Unit 3-1 2BR 1 1,212 ft² Level 1 1,212 ft² IL Unit 3-2 2BR 2 1,177 ft² Level 1 2,354 ft² MC Unit 0-1 MC Studio 10 429 ft² Level 1 4,288 ft² MC Unit 0-2 MC Studio 11 508 ft² Level 1 5,593 ft² MC Unit 0-3 MC Studio 1 477 ft² Level 1 477 ft² MC Unit 1-1 MC Studio 2 599 ft² Level 1 1,198 ft² 31 18,467 ft² Level 2 AL Unit 0-0 AL Studio 2 434 ft² Level 2 868 ft² AL Unit 0-1 AL Studio 3 508 ft² Level 2 1,525 ft² AL Unit 1-0 AL 1BR 1 696 ft² Level 2 696 ft² AL Unit 1-2 AL 1BR 1 694 ft² Level 2 694 ft² AL Unit 1-3 AL 1BR 1 726 ft² Level 2 726 ft² IL Unit 1-0 1BR 3 726 ft² Level 2 2,179 ft² IL Unit 1-1 1BR 1 687 ft² Level 2 687 ft² IL Unit 1-5 1BR 1 763 ft² Level 2 763 ft² IL Unit 1-8 1BR 2 719 ft² Level 2 1,439 ft² IL Unit 2-0 1BR+D 7 943 ft² Level 2 6,598 ft² IL Unit 2-1 1BR+D 1 1,071 ft² Level 2 1,071 ft² IL Unit 2-2 1BR+D 1 915 ft² Level 2 915 ft² IL Unit 2-4 1BR+D 1 857 ft² Level 2 857 ft² IL Unit 3-1 2BR 1 1,212 ft² Level 2 1,212 ft² IL Unit 3-2 2BR 2 1,177 ft² Level 2 2,354 ft² 28 22,583 ft² Level 3 AL Unit 0-0 AL Studio 2 434 ft² Level 3 868 ft² AL Unit 0-1 AL Studio 3 508 ft² Level 3 1,525 ft² AL Unit 1-0 AL 1BR 1 696 ft² Level 3 696 ft² AL Unit 1-1 AL Studio 2 651 ft² Level 3 1,302 ft² AL Unit 1-2 AL 1BR 1 694 ft² Level 3 694 ft² AL Unit 1-3 AL 1BR 1 726 ft² Level 3 726 ft² IL Unit 1-0 1BR 4 726 ft² Level 3 2,905 ft² IL Unit 1-1 1BR 2 687 ft² Level 3 1,374 ft² IL Unit 1-2 1BR 5 651 ft² Level 3 3,254 ft² IL Unit 1-6 1BR 1 640 ft² Level 3 640 ft² IL Unit 1-8 1BR 2 719 ft² Level 3 1,439 ft² IL Unit 2-0 1BR+D 7 943 ft² Level 3 6,598 ft² IL Unit 2-1 1BR+D 1 1,071 ft² Level 3 1,071 ft² IL Unit 2-2 1BR+D 1 915 ft² Level 3 915 ft² IL Unit 2-3 1BR+D 1 865 ft² Level 3 865 ft² IL Unit 2-4 1BR+D 1 857 ft² Level 3 857 ft² IL Unit 3-1 2BR 1 1,212 ft² Level 3 1,212 ft² IL Unit 3-2 2BR 2 1,177 ft² Level 3 2,354 ft² 38 29,294 ft² Level 4 AL Unit 0-0 AL Studio 2 434 ft² Level 4 868 ft² AL Unit 0-1 AL Studio 3 508 ft² Level 4 1,525 ft² AL Unit 1-0 AL 1BR 1 696 ft² Level 4 696 ft² AL Unit 1-1 AL Studio 2 651 ft² Level 4 1,302 ft² AL Unit 1-2 AL 1BR 1 694 ft² Level 4 694 ft² AL Unit 1-3 AL 1BR 1 726 ft² Level 4 726 ft² IL Unit 1-0 1BR 3 726 ft² Level 4 2,179 ft² IL Unit 1-1 1BR 2 687 ft² Level 4 1,374 ft² IL Unit 1-2 1BR 5 651 ft² Level 4 3,254 ft² IL Unit 1-5 1BR 1 763 ft² Level 4 763 ft² IL Unit 1-6 1BR 1 640 ft² Level 4 640 ft² IL Unit 1-8 1BR 2 719 ft² Level 4 1,439 ft² IL Unit 2-0 1BR+D 7 943 ft² Level 4 6,598 ft² IL Unit 2-1 1BR+D 1 1,071 ft² Level 4 1,071 ft² IL Unit 2-2 1BR+D 1 915 ft² Level 4 915 ft² IL Unit 2-3 1BR+D 1 865 ft² Level 4 865 ft² IL Unit 2-4 1BR+D 1 857 ft² Level 4 857 ft² IL Unit 3-1 2BR 1 1,212 ft² Level 4 1,212 ft² IL Unit 3-2 2BR 2 1,177 ft² Level 4 2,354 ft² 38 29,330 ft² Grand total: 135 135 99,675 ft² Total Gross Area Level Area Level 4 34,793 ft² Level 3 34,756 ft² Level 2 33,961 ft² Level 1 38,760 ft² Level -1 39,304 ft² Grand total 181,574 ft² Parking Schedule Type Count Level -1 91 91 Level 1 51 51 142 N Residential Unit Mix Name Count Unit Gross Area ADA Type AL Unit 0-0 6 434 ft²AL Studio AL Unit 0-1 9 508 ft²AL Studio AL Unit 1-0 3 696 ft²AL 1BR AL Unit 1-1 4 651 ft²AL 1BR AL Unit 1-2 3 694 ft²AL 1BR AL Unit 1-3 3 726 ft²AL 1BR IL Unit 1-0 11 726 ft²1BR IL Unit 1-1 5 687 ft²1BR IL Unit 1-2 10 651 ft²1BR IL Unit 1-5 3 763 ft²1BR IL Unit 1-6 2 640 ft²1BR IL Unit 1-8 6 719 ft²1BR IL Unit 2-0 22 943 ft²1BR+D IL Unit 2-1 3 1,071 ft²1BR +D IL Unit 2-2 4 915 ft²1BR+D IL Unit 2-3 2 865 ft²1BR+D IL Unit 2-4 3 857 ft²1BR+D IL Unit 3-1 4 1,212 ft²2BR IL Unit 3-2 8 1,177 ft²2BR MC Unit 0-1 10 429 ft²MC Studio MC Unit 0-2 11 508 ft²MC Studio MC Unit 0-3 1 477 ft²MC Studio MC Unit 1-1 2 599 ft²MC Studio Grand total: 135 135 45 ....Schema 1 Legend 1BR 1BR+D 2BR AL 1BR AL Studio Circulation Commons Core SD_1275 SD_126 6 SD_126 7 SD_126 4 SD_1273 SD_127 2 SD_1271 SD_126 2 SD_126 1 FIRE WALL SD_126 5 SD_127 4 SD_126 3 1,826 ft²Community Rm467 ft² Family Room 434 ft² Lib. 2 Story 487 ft² Activity 871 ft² Fitness 420 ft² TUB 759 ft² Theater Rooftop Deck -Verify w/ StructuralTRASH ELEC/LV. ELEV. LOBBY 542 ft² Salon Elec/LV OFFICELAUNDRY RRACTIVITY DIR. OFFICEFR SD_1275 SD_126 6 SD_126 7 SD_126 4 SD_1273 SD_127 2 SD_1271 SD_126 2 SD_126 1 SD_126 5 SD_127 4 SD_126 3 207 ft² Lounge Schema 1 Legend 1BR 1BR+D 2BR AL 1BR AL Studio Circulation Commons Core TRASH ELEC/LV. ELEV. LOBBY Elec/LV OFFICELAUNDRY SD_1275 SD_126 6 SD_126 7 SD_126 4 SD_1273 SD_127 2 SD_1271 SD_126 2 SD_126 1 SD_126 5 SD_127 4 SD_126 3 Schema 1 Legend 1BR 1BR+D 2BR AL 1BR AL Studio Circulation Core TRASH ELEC/LV. ELEV. LOBBY Elec/LV OFFICELAUNDRY kaas wilson architects St Anthony Village - Senior Level 2-4 1/32" = 1'-0"1 Level 2 1/32" = 1'-0"2 Level 3 1/32" = 1'-0"3 Level 4 N 46 MAU674 ft² Staff 351 ft² Mechanical Room 12 23 15 14 13 80 76 75 74 73 29 30 3335 27 88 87 86 85 5 6 7 89 12 11 10 72 71 706968676564 39404142434445465051 52 3738 9 84 66545556576362 36 1,883 ft² Resident STO EXHAUSTSTAIRSTAIR8 TRASH81 34 Bike StorageNRR554 ft² Maintenace RM 616059 50 49 48 53 79 83 1820192221 STAIR34 90 91 92 26 25 24 17 16 58 kaas wilson architects St Anthony Village - Senior Garage - Overall 1/16" = 1'-0"1 Garage Level Plan GARAGE LEVEL • 92 Underground Parking Stalls • Bike Parking • Maintenance Shop • Resident Storage Lockers • Staff Lounge 47 REF... .. 972 ft² Lobby 1,018 ft² AL Dining 2,164 ft² Kitchen 3,116 ft² IL Dining 1,290 ft² Mail Cafe 1,073 ft² Club RmTRASH 1,196 ft² MC Lounge 1,405 ft² Offices 437 ft² Bistro Nurse's Suite1,131 ft² MC Dining FIRE WALL OUTDOOR PATIO MEMORY CARE GARDEN 347 ft² Pvt. Dining M/E508 ft² MC Unit 0-2 429 ft² MC Unit 0-1 429 ft² MC Unit 0-1 508 ft² MC Unit 0-2 NRRRRRRSkills StationPARCELIT429 ft² MC Unit 0-1 915 ft² IL Unit 2-2 1,177 ft² IL Unit 3-2 429 ft² MC Unit 0-1 477 ft² MC Unit 0-3 1,212 ft² IL Unit 3-1 1,177 ft² IL Unit 3-2 943 ft² IL Unit 2-0 429 ft² MC Unit 0-1 599 ft² MC Unit 1-1 599 ft² MC Unit 1-1 508 ft² MC Unit 0-2 429 ft² MC Unit 0-1 508 ft² MC Unit 0-2 429 ft² MC Unit 0-1 508 ft² MC Unit 0-2 508 ft² MC Unit 0-2 429 ft² MC Unit 0-1 429 ft² MC Unit 0-1 508 ft² MC Unit 0-2 429 ft² MC Unit 0-1 508 ft² MC Unit 0-2 763 ft² IL Unit 1-5 726 ft² IL Unit 1-0 508 ft² MC Unit 0-2 508 ft² MC Unit 0-2 508 ft² MC Unit 0-2 STAIRSTAIRkaas wilson architects St Anthony Village - Senior Level 1 - Overall 1/16" = 1'-0"1 Level 1 Plan LEVEL 1 • 2-Story Lobby • 2 Full Service Dining Rooms • Commercial Kitchen • Staff Offices and Concierge • Club Room • Outdoor Patio • Memory Care Lounge and Dining • Memory Care Garden 48 434 ft² Lib. 2 Story 1,826 ft² Community Rm 487 ft² Activity 542 ft² Salon 434 ft² AL Unit 0-0 508 ft² AL Unit 0-1 508 ft² AL Unit 0-1 508 ft² AL Unit 0-1 696 ft² AL Unit 1-0 467 ft² Family Room 759 ft² Theater 420 ft² TUB FIRE WALL M/E/TRM/E871 ft² Fitness 943 ft² IL Unit 2-0 687 ft² IL Unit 1-1 NRRACTIVITY OFFICESTORR719 ft² IL Unit 1-8 1,071 ft² IL Unit 2-1 915 ft² IL Unit 2-2 1,212 ft² IL Unit 3-1 1,177 ft² IL Unit 3-2 1,177 ft² IL Unit 3-2 943 ft² IL Unit 2-0 726 ft² IL Unit 1-0 943 ft² IL Unit 2-0 749 sf Rooftop Deck VISITG PHY.434 ft² AL Unit 0-0 694 ft² AL Unit 1-2726 ft² AL Unit 1-3 943 ft² IL Unit 2-0 943 ft² IL Unit 2-0 943 ft² IL Unit 2-0 726 ft² IL Unit 1-0 943 ft² IL Unit 2-0 857 ft² IL Unit 2-4 726 ft² IL Unit 1-0 763 ft² IL Unit 1-5 STAIRSTAIRkaas wilson architects St Anthony Village - Senior Level 2 - Overall 1/16" = 1'-0"1 Level 2 Plan LEVEL 2 • Lobby Overlook • Theatre • Salon and Spa • Fitness Room • Community Room • Rooftop Deck • Family Room • Activity Room • Library • Medical Charting Area • Community Laundry 49 865 ft² IL Unit 2-3 687 ft² IL Unit 1-1 508 ft² AL Unit 0-1 508 ft² AL Unit 0-1 508 ft² AL Unit 0-1 696 ft² AL Unit 1-0 M/E/TRM/E651 ft² IL Unit 1-2 651 ft² IL Unit 1-2 N1,071 ft² IL Unit 2-1 1,212 ft² IL Unit 3-1 1,177 ft² IL Unit 3-2 1,177 ft² IL Unit 3-2 915 ft² IL Unit 2-2 434 ft² AL Unit 0-0 687 ft² IL Unit 1-1 943 ft² IL Unit 2-0 943 ft² IL Unit 2-0 640 ft² IL Unit 1-6 726 ft² IL Unit 1-0 943 ft² IL Unit 2-0 943 ft² IL Unit 2-0 943 ft² IL Unit 2-0 943 ft² IL Unit 2-0 943 ft² IL Unit 2-0 726 ft² IL Unit 1-0 726 ft² AL Unit 1-3 651 ft² AL Unit 1-1 651 ft² AL Unit 1-1 651 ft² IL Unit 1-2 651 ft² IL Unit 1-2 651 ft² IL Unit 1-2 857 ft² IL Unit 2-4 726 ft² IL Unit 1-0 434 ft² AL Unit 0-0 694 ft² AL Unit 1-2 763 ft² IL Unit 1-5 STAIR STAIR kaas wilson architects St Anthony Village - Senior Level 3-4 - Overall 1/16" = 1'-0"1 Level 3 and 4 Plan LEVEL 3 & 4 • Medical Charting Area • Community Laundry • Resident Lounge 50 SD_127 5 SD_126 6 SD_126 7 SD_126 4 SD_127 3 SD_127 2 SD_127 1 SD_126 2 SD_1261 SD_126 5 SD_127 4 SD_126 3 RWLODRWLODRWLODRWLODRWL OD RWLODRWLODRWLODRWLODRTURTURTU RTU FLAT ROOF MEMBRANE, TYP. FLAT ROOF -1-STORY FLAT ROOF MEMBRANE, TYP.NFLAT ROOF MEMBRANE, TYP. FLAT ROOF MEMBRANE, TYP. FLAT ROOF MEMBRANE, TYP.PORTE COCHERE - FLAT ROOF RWL OD RWL OD kaas wilson architects St Anthony Village - Senior Roof Plan 1/16" = 1'-0"1 Roof Plan 51 Exterior Material Tag Key 4.1 BRICK MASONRY 5.1 BALCONY - ALUMINUM RAIL - COLOR: CHAMPAGNE 7.1 CFB SHAKE SIDING - COLOR: B.MOORE - POLO BLUE 8.1 MAGIC PAK GRILL - COLOR: CUSTOM PAINTED TO MATCH SURROUNDING FIELD COLOR 7.4 CFB TRIM - COLOR: SW7636 ORIGAMI WHITE 7.3 CFB PANEL SIDING - COLOR: SW7636 ORIGAMI WHITE 7.2 CFB LAP SIDING - COLOR: SW7641 COLLONADE GRAY 4.2 SPLIT FACE BLOCK MASONRY 4.1 5.1 8.17.47.3 7.27.4 7.1 49'-9"4.1 5.1 7.1 7.37.2 7.4 47'-6 3/4"7.4 Level 1 100'-0" Level 2 111'-1 7/8" Level -1 88'-8" Level 3 122'-3 3/4" Level 4 133'-5 5/8" Truss Brg. 142'-6 3/4" 4.15.1 7.1 7.47.3 7.2 7.47.4 4.2 52'-3 1/8"Level 1 100'-0" Level 2 111'-1 7/8" Level 3 122'-3 3/4" Level 4 133'-5 5/8" Truss Brg. 142'-6 3/4" 4.1 5.1 7.17.47.3 7.27.4 47'-6 3/4"45'-6 3/4"4.15.1 7.1 7.47.3 7.27.4 4.1 5.1 7.17.47.3 7.27.4 45'-6 3/4"47'-6 3/4"4.1 5.1 7.17.47.3 7.27.4 45'-6 3/4"kaas wilson architects St Anthony Village - Senior Exterior Elevations 3/32" = 1'-0"4 West Elevation 3 3/32" = 1'-0"2 West Elevation 1 3/32" = 1'-0"1 South Elevation 3/32" = 1'-0"6 West Elevation 5 3/32" = 1'-0"7 North Elevation 3/32" = 1'-0"3 West Elevation 2 3/32" = 1'-0"5 West Elevation 4 52 Exterior Material Tag Key 4.1 BRICK MASONRY 5.1 BALCONY - ALUMINUM RAIL - COLOR: CHAMPAGNE 7.1 CFB SHAKE SIDING - COLOR: B.MOORE - POLO BLUE 8.1 MAGIC PAK GRILL - COLOR: CUSTOM PAINTED TO MATCH SURROUNDING FIELD COLOR 7.4 CFB TRIM - COLOR: SW7636 ORIGAMI WHITE 7.3 CFB PANEL SIDING - COLOR: SW7636 ORIGAMI WHITE 7.2 CFB LAP SIDING - COLOR: SW7641 COLLONADE GRAY 4.2 SPLIT FACE BLOCK MASONRY Level 1 100'-0" Level 2 111'-1 7/8" Level 3 122'-3 3/4" Level 4 133'-5 5/8" Truss Brg. 142'-6 3/4" 4.1 5.1 7.1 7.47.37.2 7.4 47'-6 3/4"4.1 5.1 7.17.47.27.4 45'-6 3/4"45'-6 3/4"4.1 5.1 7.17.47.27.4 Level 1 100'-0" Level 2 111'-1 7/8" Level 3 122'-3 3/4" Level 4 133'-5 5/8" Truss Brg. 142'-6 3/4" 4.1 5.1 7.17.47.3 7.27.44.2 45'-6 3/4"4.15.1 7.17.47.3 7.24.1 51'-7 1/8"kaas wilson architects St Anthony Village - Senior Exterior Elevations 3/32" = 1'-0"1 East Elevation 1 3/32" = 1'-0"2 East Elevation 2 3/32" = 1'-0"3 East Elevation 3 3/32" = 1'-0"4 East Elevation 4 3/32" = 1'-0"5 East Elevation 5 53 kaas wilson architects St Anthony Village - Senior Exterior Rendering 54 kaas wilson architects St Anthony Village - Senior Exterior Rendering 55 kaas wilson architects St Anthony Village - Senior Exterior Rendering 56 kaas wilson architects St Anthony Village - Senior Exterior Rendering 57 N E W B R I G H T O N B L V D .NE LOWRY AVENE STINSON AVE SILVER LAKE ROAD NE29TH AVE NEAPPROXIMATEPROJECTLOCATIONARCHITECTKAAS WILSON ARCHITECTS1301 AMERICAN BLVD E.BLOOMINGTON, MN 55425(P) - (612)-332-5420CONTACT: LINK WILSON, AIAENGINEERWENCK ASSOCIATES, INC.7500 OLSON MEMORIAL HWYGOLDEN VALLEY, MN 55427(P) - (763)-252-6886CONTACT: DAN LAVENDER, P.E.VICINITY MAPNOT TO SCALEPRELIMINARY CIVIL SITE CONSTRUCTIONPLANSFORINDEPENDENT SENIOR LIVINGST. ANTHONY, MINNESOTA 55418DECEMBER 2020PROJECT LOCATIONCITY: ST. ANTHONYCOUNTY: HENNEPINDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-001 COVER SHEET 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:47:50 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 C-001COVER SHEETSHEET INDEXSHEET NUMBERSHEET TITLEC-001COVER SHEETC-003EXISTING CONDITIONSC-004 REMOVALS AND PRE-CONSTRUCTION EROSION CONTROL PLANC-101OVERALL SITE PLANC-102ENLARGED SITE PLANC-201POST-CONSTRUCTION STABILIZATION PLANC-301GRADING PLANC-401UTILITY PLANC-501OVERALL STORM SEWER PLANC-502ENLARGED STORM SEWER PLANC-801DETAILSC-802DETAILSC-803DETAILSC-804DETAILSC-805DETAILSL-101LANDSCAPE PLANL-102NOTES & DETAILS58 SINGLE TRA I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRA I L E R DOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE T R A I L E R SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R 2261011031051071 09 1111 13 1 15 1 17 119121123120118116114112110108106104102201203205207209211213202204206208210212214216218220228230SINGLE T R A I L E R 224DOUBLE TRAILER DOUBLE TRAILER SINGLE TRAILER SINGLE TRA I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRA I L E R DOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE T R A I L E R SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R 2261011031051071 09 1111 13 1 15 1 17 119121123120118116114112110108106104102201203205207209211213202204206208210212214216218220228230SINGLE T R A I L E R 224DOUBLE TRAILER DOUBLE TRAILER SINGLE TRAILEROAK STIRONWOOD STLOCUST STJUNIPER STELM ST WELM STHEMLOCK STASH STPINE STASH STELM STMAIN STMAIN ST CEDAR STGUM STPINE STKENZIE TERRACENE STINSON PKWYALLEY915 915915 915915 915915915915915915915915 920920920920920920 920920920 920925925925925925925 925 925 925925 925 925925925 925 925925925925925925925925925925925925925930930930 911911 912912 912 9 1 2 913913913 913913913913 913913 914 914914914 914914914914 9149 1 4914 916 9169 1 6 916 916916916916916916 916916 916 917917 917 917917917917917 917917 917 917 918918918918918 91 8 91891 8 918 918918918918919919919919919919 9 1 9919 919919 919921921921921 921921921921921921921921921922922922922922922922922922 922 922923923923923923923923923923923923923923923923923923 923 923924924924 924924 924 924 924 924924924924 924 924926 926 926926926926926926926926926926926927927927927927927927927927927927927928928928928928928928928928928928928929929929929929929 9 2 9 929PROPERTY BOUNDARYPROPERTY BOUNDARYPROPERTY BOUNDARYPROPOSED PROPERTY LINEPROPERTY BOUNDARYURBAN GROVE MANUFACTUREDHOMES COMMUNITYDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-003 EXISTING CONDITIONS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:48:21 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 ( IN FEET )GRAPHIC SCALE01 inch = 60 ft.6012060XXLOT LINEEASEMENT LINESETBACK LINEEXISTING FENCE LINEEXISTING STORM SEWEREXISTING SANITARY SEWERFMFMEXISTING FORCEMAINEXISTING WATERMAINF/OF/OEXISTING UNDERGROUND FIBER OPTIC LINEOUEXISTING OVERHEAD UTILITY LINEEXISTING TREE LINEEXISTING CONCRETE SURFACEEXISTING ASPHALT SURFACEEXISTING BUILDINGEXISTING MINOR CONTOUREXISTING MAJOR CONTOURRIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARYEXISTING CURB AND GUTTEREXISTING SANITARY MANHOLEEXISTING CLEANOUTEXISTING STORM SEWER MANHOLEEXISTING STORM SEWER INLETEXISTING STORM SEWER INLETEXISTING FLARED END SECTIONEXISTING CURB STOPEXISTING HYDRANTEXISTING WATER WELLEXISTING WATER VALVETPWVWDYHEXISTING COMMUNICATIONS PEDESTALEXISTING ELECTRIC METEREXISTING SIGNEXISTING UTILITY POLEEXISTING ANCHOR CABLEEXISTING LIGHT POLEEXISTING STUMPEXISTING DECIDUOUS TREEEXISTING CONIFEROUS TREELEGENDC-003EXISTING CONDITIONS1. SEE SHEET C-002 FOR ADDITIONAL PROJECT NOTES.2. PROPOSED URBAN GROVE MANUFACTURED HOMES ARESHOWN ON PLANS AND ARE CURRENTLY UNDERCONSTRUCTION. VERIFY CONDITIONS IN THE FIELD PRIOR TOCONSTRUCTION.NOTES59 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 105 104 102 201 203 202 204 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 105 104 102 201 203 202 204 LOCUST ST JUNIPER ST ELM ST W ASH ST PINE STELM STMAIN STMAIN STCEDAR ST GUM ST NE STINSON PKWYALLEY 920920920 9209259259 2 5 92 5925925925925925925925925925925925930930 916917917918918918918918919919921921921921921921921 921922922922922922922922922922 922923923923923923923923 923923923 924924924 9249249249249249249249249249269269269269269269269269269269269269269269 2 692692 6 9 2 6 926926926 926926 92 7927927927927927927927927 927927928928928 928928928928 929 929929929929929929 11122222222222233333333333233344444444444444456666666677788899999999999101010101010101010101111111011121213151515151515417162221518181818181419191919222020202020212121212188832323DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-004 REMOVALS AND PRE-CONSTRUCTION EROSION CONTROL PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:48:52 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 ( IN FEET )GRAPHIC SCALE01 inch = 30 ft.3060301. SEE SHEET C-002 FOR ADDITIONAL PROJECT NOTES.2. CONSTRUCTION SITE SHALL HAVE A STABILIZED EXIT AT ALLTIMES THROUGHOUT THE DURATION OF THE PROJECT.CONTRACTOR IS ULTIMATELY RESPONSIBLE TO PROTECTDOWNSTREAM WATERS FROM CONSTRUCTION RUNOFF.3. CONSTRUCTION LIMITS AND SILT FENCE ARE SHOWN OFFSETFOR CLARITY, WHERE APPLICABLE.4. CLEAR AND GRUB AS NEEDED FOR CONSTRUCTION WITHIN THELIMITS OF DISTURBANCE.5. REMOVE ALL UTILITY SERVICES AND STRUCTURES WITHINAREAS OF IMPROVEMENTS, UNLESS OTHERWISE NOTED.COORDINATE WITH UTILITY COMPANIES AS NECESSARY FORREMOVAL OR RELOCATION.NOTESLEGENDLOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARYXXREMOVE FENCEREMOVE STORM SEWERREMOVE SANITARY SEWERFMFMREMOVE FORCEMAINREMOVE WATERMAINCOMREMOVE UNDERGROUND COMMUNICATION LINEOUREMOVE OVERHEAD UTILITY LINEREMOVE SANITARY MANHOLEREMOVE CLEANOUTREMOVE HYDRANTTPDYH REMOVE COMMUNICATIONS PEDESTALREMOVE ELECTRIC METERREMOVE BOLLARD/POSTREMOVE UTILITY POLEREMOVE ANCHOR CABLEREMOVE LIGHT POLEREMOVE STUMPREMOVE BITUMINOUS PAVEMENTREMOVE CONCRETE PAVEMENTSAWCUT PAVEMENTREMOVE BUILDINGREMOVE TREEC-004REMOVALS ANDPRE-CONSTRUCTIONEROSION CONTROL PLAN1. REMOVE BUILDING2. REMOVE BITUMINOUS SURFACE3. REMOVE CONCRETE SURFACE4. REMOVE TREE (TYP.)5. REMOVE BOLLARD6. REMOVE UTILITY POLE (TYP.)7. REMOVE LIGHT POLE (TYP.)8. REMOVE WATERMAIN9. REMOVE SANITARY CLEANOUT (TYP.)10. REMOVE SANITARY SEWER (TYP.)11. REMOVE SANITARY MANHOLE12. PROTECT EXISTING TORNADO SHELTER13. SALVAGE EXISTING FIRE HYDRANT14. REMOVE EXISTING LIFT STATION15. INSTALL TREE PROTECTION (TYP.)16. INSTALL INLET PROTECTION17. INSTALL ROCK CONSTRUCTION ENTRANCE18. INSTALL SILT FENCE19. REMOVE EXISTING FENCE20. REMOVE COMMUNICATIONS PEDESTAL (TYP.)21. REMOVE ELECTRIC METER (TYP.)22. ABANDON EXISTING WATER WELL23. REMOVE EXISTING STEPS AND RETAINING WALLKEYNOTES#ROCK CONSTRUCTION ENTRANCESILT FENCEINLET PROTECTIONTEMPORARY DIVERSION DITCHCULVERT PROTECTIONTREE PROTECTIONTEMPORARY SEDIMENT TRAP DISCHARGE60 SINGLE TRA I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRA I L E R DOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R 2261011031 05 1 07 1091 11 1 13 1 15 1 17 1 19 1 21 1231201181 16 1 14 1 12110108106104102 201203205207209211213202204206208210212214216218220228230SINGLE T R A I L E R 224DOUBLE TRAILER DOUBLE TRAILER SINGLE TRAILER SINGLE TRA I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRA I L E R DOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R 2261011031 05 1 07 1091 11 1 13 1 15 1 17 1 19 1 21 1231201181 16 1 14 1 12110108106104102 201203205207209211213202204206208210212214216218220228230SINGLE T R A I L E R 224DOUBLE TRAILER DOUBLE TRAILER SINGLE TRAILERKENZIE TERRACENE STINSON PKWYALLEYURBAN GROVE MANUFACTUREDHOMES COMMUNITYSENIOR LIVING4 STORIES135 UNITSSTORMWATERPONDSTORMWATERPONDGRASSED FIRE LANECONCRETE PAVEMENTGRAVEL SURFACINGRETAINING WALL (BY OTHERS)C-101OVERALL SITE PLANDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-101 SITE PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:49:26 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 1. SEE SHEET C-002 FOR ADDITIONAL PROJECT NOTES.2. PROPOSED URBAN GROVE MANUFACTURED HOMES ARESHOWN ON PLANS AND ARE CURRENTLY UNDERCONSTRUCTION. VERIFY CONDITIONS IN THE FIELD PRIOR TOCONSTRUCTION.NOTESPROPERTY BOUNDARYCURB AND GUTTERROAD CENTERLINE#BITUMINOUS PAVEMENT( IN FEET )GRAPHIC SCALE01 inch = 60 ft.6012060LEGENDLOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEPROPERTY BOUNDARYCURB AND GUTTERROAD CENTERLINE#PROPOSED PARKING COUNTBITUMINOUS PAVEMENTSEE SHEET C-102EXISTING PROPERTY LINE61 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 202 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 202 NE STINSON PKWYALLEY 71253333333321921991010101010101488881222211151516161810161624'24'24'9'TYP.19'TYP.19'TYP.9'TYP.9'TYP.19'TYP.19'TYP.9'TYP.24'24'24'9'TYP.19' TYP.24'24' 24' 24'5'5'5'5'5'24'R5'R5'R30'R30'R20'R5'R5'R5'R1 6 'R16'R 2 'R2'R20' R20' R5 'R5'R5'R3.7'R3.7' R10' R10'R5'R3.7'R3.7'R3.7'R3 . 7 ' R 5 ' R1 0 ' R10'10106226161924' 22' 22'2292.6'112.2'21'114.1'322252525232323R78' R75' R75'26102727183224'R1 5 'R15'101024'633R15'R16'22R15'R39'1111111111R34'8'5'R3'SENIOR LIVING4 STORIES135 UNITSSTORMWATERPONDSTORMWATERPONDR3'R10'R5'R5'R15'R53' R15'R25'R5'24'R15'5'1202411DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-101 SITE PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:49:37 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 1. SEE SHEET C-002 FOR ADDITIONAL PROJECT NOTES.NOTES1. MATCH EXISTING2. BITUMINOUS PAVEMENT3. CONCRETE SIDEWALK4. CONCRETE PAVEMENT5. MEMORY CARE GARDEN- SEE ARCHITECTURAL/ STRUCTURALPLANS6. OUTDOOR PATIO - SEE ARCHITECTURAL/ STRUCTURAL PLANS7. TRENCH DRAIN8. GRASSPAVE FIRE LANE9. PAVEMENT STRIPE (TYP.)10. B612 CONCRETE CURB AND GUTTER (TYP.)11. RETAINING WALL (DESIGN BY OTHERS)12. UNDERGROUND PARKING ENTRANCE13. STORMWATER POND14. OVERHANGING BUILDING ENTRANCE - SEE ARCHITECTURAL/STRUCTURAL PLANS15. PROTECT EXISTING TORNADO SHELTER16. SURMOUNTABLE CURB AND GUTTER17. NOT USED18. 5' CURB TRANSITION TO SURMOUNTABLE CURB AND GUTTER19. STRUCTURAL COLUMN (TYP.) - SEE ARCHITECTURAL/STRUCTURAL PLANS20. NOT USED21. ADA ACCESSIBLE PARKING STALL W/ ACCESS AISLE22. PROPOSED ACCESS ROAD FROM KENZIE TERRACE WITHVEGETATED BUFFER STRIP ON EAST SIDE OF ROAD23. UNDERGROUND STORMWATER CHAMBER SYSTEM24. CONCRETE STAIRS - SEE ARCHITECTURAL/ STRUCTURAL PLANS25. PROPOSED LANDSCAPING EASEMENT26. 5' WIDE CONCRETE DRAINAGE SWALE27. 3' CURB TRANSITION TO ZERO HEIGHTKEYNOTESGRASSED FIRE LANECONCRETE PAVEMENTGRAVEL SURFACINGRETAINING WALL (BY OTHERS)C-102ENLARGED SITE PLAN#PROPERTY BOUNDARYCURB AND GUTTERROAD CENTERLINE#BITUMINOUS PAVEMENT( IN FEET )GRAPHIC SCALE01 inch = 30 ft.306030LEGENDLOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARYCURB AND GUTTERROAD CENTERLINE#PROPOSED PARKING COUNTBITUMINOUS PAVEMENT62 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 105 107 106 104 102 201 203 205 202 204 206 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 105 107 106 104 102 201 203 205 202 204 206 NE STINSON PKWYALLEY 920920920920920920920 92092092092 0 925925 925925925925925 925925925 925 9 2 59259259259 2 5 925925925925925925925925925 925925925925925925 925 930930930 918918919919919919 921921921 921921921921 92192192 1 921 921922922922922922922 922 922 922922922922 922 92292392392392392392392392392392392392392 3 923923923923923 923 924 9 2 4 9249249 2 4 924 924924 924924 9249 2 4 924924924 924924924924924924924924924 926926926926926926926926 9269 2 6 926926926926926 926 926926 926926926 9 2 7 9 2 7 927927927927927 927927927927 927 9 2 7 927927927928928928928928928928928 928928 928928 929 929 929929929929 929 9299299294-STORYSENIOR LIVING BUILDINGFFE=926.00LLE=915.00IIIIIIIIIIIIII I I I I I I I I ►►►►►►►►►►►►►►►►►►►►►► ►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►► ►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►IIIIIIIIIIIIIIIIIII I I I IIIIIIIIIIIIIIIIIIIIIIIII►►►►►►►►►►►►►►►►IIII I I I I I I I IIIIIIIIIIIIIIIIIIIII►►►►►►11122222222244435555566777528.7% 16.7%7.3%4.2%5.2%5.0%8.5%24.6%1.7%2.4%4:1 4:1 3 . 9%4.9%6.2%4:14:14:1 4:110:13:1 3:1 10:110:1 4:124.3% 1.3% 3.2%1.0%5.2%5.9%1.3%10.6%14.7%25.0%3:14:1 5.1% 6.3%11.8%2.5%2.0%2. 8%4.7%3.1%►►►►►►►►►►►►►►►►►►10:14:13:110:14:15925924926925925923924924 924924925925923924924922922922 9229239232.1%1.7%2.2%8.2%9259259239 2 3 92492 4926 915 920 916 917 918 919 921 922 9.3%4.9% 2. 4 % 2. 3 % 2.0%1.5%2.6 % 1.6 % 2.0% 2.7 %925924926927925923924926923 925926DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-201 POST-CONSTRUCTION STABILIZATION PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:50:22 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 21. SEE SHEET C-002 FOR ADDITIONAL PROJECT NOTES.NOTES1. SILT FENCE - SEE DETAIL2. EROSION CONTROL BLANKET - SEE DETAIL3. ROCK CONSTRUCTION ENTRANCE - SEE DETAIL4. TREE PROTECTION (TYP.) - SEE DETAIL5. INLET PROTECTION - SEE DETAIL6. CULVERT END PROTECTION - SEE DETAIL7. RIPRAP - SEE DETAILKEYNOTES#ROCK CONSTRUCTION EXITSILT FENCEINLET PROTECTIONEROSION CONTROL BLANKETRIPRAPCULVERT PROTECTIONTREE PROTECTIONEXISTING MINOR CONTOUREXISTING MAJOR CONTOURPROPOSED MINOR CONTOUR901PROPOSED MAJOR CONTOUR900CONSTRUCTION LIMITSSTORM MANHOLESTORM CATCH BASINFLARED END SECTION►►SANITARY SEWERIIWATERMAINSANITARY MANHOLEHYDRANTGATE VALVE►►►►STORM SEWERC-201POST-CONSTRUCTIONSTABILIZATION PLAN( IN FEET )GRAPHIC SCALE01 inch = 30 ft.306030LOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARYLEGEND63 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 105 107 106 104 102 201 203 205 202 204 206 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 105 107 106 104 102 201 203 205 202 204 206 NE STINSON PKWYALLEY ►►►►►►►►►►►►►►►►►►►►►► ►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►► ►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►IIIIIIIIIIIIII I I I I I I I IIIIIII IIIIIIIIIIIII I I I IIIIIIIIIIIIIIIIIIIIIIIII9209209209 2 0 920920 925925 92 5 925925925 925925925925 925925930930930 917917918918918 9189199199199 1 9 921921921921921 921921 921922922922 922 922 922922922922 922923923923923923 923 923923 9239249 2 4 92492 4 924924 924924924924924 926926926926926926926926926926 9269 2 6 926926 926927927927927927927 927 927 928928928928928928 928 928929929929929929929925925925 923924 926925926925925923924 920 918919921922922922923923 920 916 917 918 919 921 922 9 2 3 923 2.7%1.9%2.0%2.6%3.2%2.9%5.3%5.7%3.7%3.4%1.9%2.6 % 5.8% 1.1% 1.8 % 0.7% 1.0% 2.3% 0.3% 1.0%5.8%4.5% 2.0% 2. 3 % 3.1% 2.9% 2. 4 %1.6%11.8%5.0%4:110:14:13:13:14:14:13:110:13:1 10:17.4%1.7%4.3%4.2%2.6%5.0%24.6%7.3%16.7% 8.2%8.7%4:14:1 4:1 4.9%6.2%4:1 3:1 3:110:14:110:14:110:110:1 2.4%6.0% 5.1%1.0%3.1 % 24.9% 1.0%4.2%9.3%2.0%3.4%3.1%3.7%4-STORYSENIOR LIVING BUILDINGFFE=926.00LLE=915.00STORMWATER PONDNWL=919.00HWL=920.76STORMWATER PONDNWL=917.00HWL=921.754:13:1RETAININGWALLRETAINING WALLIIII I I I I I I I IIIIIIIIIIIIIIIII►►►►►►►►►►►►►►►►EOF:22.00EOF:22.00IIIIRETAININGWALLRETAINING WALL5.6%►►►►►►►►►►►►►►►►►►►►►►►►9159139149162.1%3.7% 2.6%92592 4926926 925923924915 920 916 917 918 919 921 922 923 92492091791891992192292091791891992192291591491692292292292392592492592592492592492492492592592392492492091992192292091992192291591491691791891591691791810:14:1 925925923924924RETAINING WALLSTAIRSBW:27.17TW:27.17TW:28.10TW:29.59TW:27.49TW:26.22BW:23.65BW:26.19BW:24.67BW:26.48BW:26.22TW:28.91TW:22.60TW:22.50TW:21.84TW:21.00BW:21.00BW:15.00BW:17.45BW:22.60TW:26.00BW:22.50TW:26.00TW:26.00TW:26.00BW:22.50BW:24.50BW:24.50BW:23.12TW:23.129229239259242.4% 2. 8%2.2%TW:22.00BW:22.00TW:22.00BW:22.00TW:23.00TW:24.50BW:22.00BW:22.00BW:22.00TW:23.00920 925921 922 923 924920920918919921920917918919921925926923 9249209259199219229239249199229239249209 2 1 9 2 2925924926927925924 925926926 DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-301 GRADING PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:51:09 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 LOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARYPROPOSED MINOR CONTOUR901PROPOSED MAJOR CONTOUR900EXISTING MINOR CONTOUREXISTING MAJOR CONTOURC-301GRADING PLAN( IN FEET )GRAPHIC SCALE01 inch = 30 ft.306030LEGEND64 SINGLE TRA I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRA I L E R DOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R 2261011031051071 09 1111 13 1 15 1 17 119121123120118116114112110108106104102201203205207209211213202204206208210212214216218220228230SINGLE T R A I L E R 224DOUBLE TRAILER DOUBLE TRAILER SINGLE TRAILER SINGLE TRA I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRA I L E R DOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R 2261011031051071 09 1111 13 1 15 1 17 119121123120118116114112110108106104102201203205207209211213202204206208210212214216218220228230SINGLE T R A I L E R 224DOUBLE TRAILER DOUBLE TRAILER SINGLE TRAILERKENZIE TERRACENE STINSON PKWYALLEY►►►►►►IIII I I IIII920925918918918919919919924 926927 927925925 925 925925930925925915915920920925920920920920925925925925 925925925925925925 915915920920915 912 9 1 2 913913914916 917 918 919 91592091 1911 912 913914 916917918919921915 915 914914 916916 917917 918919915915913913 914914916917918920 925925925 ►►►►►►►►►►►►8" GV8" DIP►►►►►►►►►► ►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►6" GV6" HYDRANT6" GVFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMFMIIIIIIIIIIIIIIIIIIIII8" DIP8" DIP8" DIP6" DIP6" HYDRANT4" DIP4" DIP8" DIP8" DIP8" DIP8" DIP 8" DIPI IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII6" DIP6" HYDRANT6" HYDRANT6" DIP 6" DIP6" DIP6" DIP6" DIP6" HYDRANT►►►►►►►►►►►►II4" DOMESTIC WATER SERVICEVERIFY INVERT, MATERIAL,LOCATION WITH MEP PLANS4" FIRE SERVICEVERIFY INVERT, MATERIAL,LOCATION WITH MEP PLANS8" SANITARY SERVICEPROPOSED INV. = 908.89VERIFY LOCATION,MATERIAL, AND INVERTWITH MEP PLANS.LS-1RIM=915.358" INV IN=902.00 (S)8" INV IN=902.00 (SW)8" INV IN=902.00 (E)6" INV OUT=902.00 (NE)SSMH-04SSMH-03SSMH-02RIM=906.888" INV IN=903.42 (S)8" INV IN=903.42 (W)8" INV IN=903.42 (E)8" INV OUT=903.32 (N)SSMH-08RIM=923.328" INV IN=908.10 (SW)8" INV OUT=908.00 (NE)SSMH-07SSMH-06SSMH-12RIM=909.828" INV IN=906.36 (SW)8" INV OUT=906.26 (E)SSMH-11SSMH-10SSMH-09SSMH-14SSMH-13SSMH-058" PVC8" PVC 132 LF OF 8" PVC @ 1.00%164 LF OF 8" PVC @ 1.00%8" PVC8" PVC284 LF OF 8" PVC @ 1.00%8" PVC 8" PVC8" PVC8" PVC8" PVC8" PVC40 LF OF 8" PVC @ 2.00%CONNECT TO EXISTING LIFT STATION.EXISTING LIFT STATION TO BECONVERTED TO REGULAR MANHOLE.VERIFY LOCATION AND INVERT.CONNECT TO EXISTING8" WATERMAIN6" PVCEXMH-15RIM=917.206" INV IN=904.10 (W)CORE DRILL AND CONNECT TOEXISTING MANHOLERELOCATE HYDRANT AND CONNECTTO EXISTING WATERMAIN. VERIFYLOCATION AND INVERT.STORMWATERPONDSTORMWATERPOND8"X6" TEE8" 90° BEND8"X4" TEE8"X4" TEE8"X6" REDUCER8" 90° BEND8"X8" TEE6" 90° BEND8" 11.25° BEND8" 22.5° BEND8" 11.25° BEND8"X6" TEE8" 11.25° BEND8" DIP CONNECT TO EXISTING8" WATERMAINAIR RELEASE MH►►4-STORYSENIOR LIVINGBUILDINGFFE=926.00LLE=915.00►►►►►►8" DIPDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-401 UTILITY PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:51:53 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 EXISTING MINOR CONTOUREXISTING MAJOR CONTOUREXISTING SANITARY MANHOLEEXISTING STORM SEWER INLETEXISTING STORM SEWEREXISTING SANITARY SEWEREXISTING WATERMAIN►►►►STORM SEWER►►SANITARY SEWERIIWATERMAINSTORM MANHOLESTORM CATCH BASINSANITARY MANHOLEHYDRANTFMFMSANITARY FORCEMAINGATE VALVEFLARED END SECTIONPROPOSED MINOR CONTOUR901PROPOSED MAJOR CONTOUR900C-401UTILITY PLANLOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARY( IN FEET )GRAPHIC SCALE01 inch = 60 ft.6012060LEGEND914.0065 SINGLE TRA I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRA I L E R DOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R 2261011031051071 09 1111 13 1 15 1 17 119121123120118116114112110108106104102201203205207209211213202204206208210212214216218220228230SINGLE T R A I L E R 224DOUBLE TRAILER DOUBLE TRAILER SINGLE TRAILER SINGLE TRA I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRA I L E R DOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERDOUBLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER SINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE T R A I L E R SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TR A I L E R 2261011031051071 09 1111 13 1 15 1 17 119121123120118116114112110108106104102201203205207209211213202204206208210212214216218220228230SINGLE T R A I L E R 224DOUBLE TRAILER DOUBLE TRAILER SINGLE TRAILERKENZIE TERRACENE STINSON PKWYALLEYIIII I I IIII►►►►►►►►►► ►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►IIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII925 925924924 925 923924 920919921922916917918915914920919921925923924 922925925924915913913914920917918919921922923920917917918919921921921922922 921923925 926 927924925926926925925925 923924920917918919921922923923 915915 920 920913913 914 914916916 917917918 918919 919921922923924915 915 920 920 912 9 1 2 913913 914914 916916 917 917 918 918 919 9199159129139149 1 6 9 1 7 289 LF OF 12" RCP @ 0.42%FES-112" INV=912.30►►►►►►►►►►►►922 922923 923IIFES-612" INV=913.0026 LF OF 12" RCP @ 0.35%STMH-2RIM=915.3012" INV IN=912.91 (W)12" INV IN=912.91 (N)12" INV OUT=912.91 (SE)186 LF OF 12" RCP @ 0.33%4-STORYSENIOR LIVINGBUILDINGFFE=926.00LLE=915.00STORMWATER PONDNWL=919.00HWL=920.76STORMWATER PONDNWL=917.00HWL=921.75920916917918919921922923924►►►►►►►►925926925925923924 920917918919921922915920916917918919921922923924120'40'920917918919921920 918 919921925924920919921920 925921922923924924 926927920921922922923 DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-501 STORM SEWER PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:52:46 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 C-501OVERALL STORMSEWER PLAN( IN FEET )GRAPHIC SCALE01 inch = 60 ft.6012060LEGENDLOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARYSEE SHEET C-502EXISTING MINOR CONTOUREXISTING MAJOR CONTOUR►►►►STORM SEWER►►SANITARY SEWERIIWATERMAINSTORM MANHOLESTORM CATCH BASINSANITARY MANHOLEHYDRANTGATE VALVEFLARED END SECTIONEXISTING STORM SEWERPROPOSED MINOR CONTOUR901PROPOSED MAJOR CONTOUR90066 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 105 107 106 104 102 201 203 205 202 204 206 SINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILERSINGLE TRAILER101 103 105 107 106 104 102 201 203 205 202 204 206 NE STINSON PKWYALLEY IIIIIIIIIIIIII I I I I I I I I ►►►►►►►►►►►►►►►►►►►►►► ►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►► ►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►IIIIIIIIIIIIIIIIIII I I I IIIIIIIIIIIIIIIIIIIIIIIIIIIII I I I I I I I IIIIIIIIIIIIIIIII4-STORYSENIOR LIVING BUILDINGFFE=926.00LLE=915.00STORMWATER PONDNWL=919.00HWL=920.76STORMWATER PONDNWL=917.00HWL=921.75CBMH-19RIM=923.0312" INV IN=919.74 (N)15" INV OUT=919.74 (S)161 LF OF 15" RCP @ 0.50%CBMH-18RIM=923.6115" INV IN=918.94 (N)15" INV OUT=918.94 (S)56 LF OF 15" RCP @ 0.50%OCS-16RIM=925.0315" INV IN=917.85 (W)15" INV OUT=917.85 (E)27 LF OF 15" RCP @ 2.15%FES-1415" INV=917.00925925924924925923924920 919921922 916917918915914920919921925 923924922925 925924915913913914920917918919921922923920917 917918919921921 921922922921923925926927 924925926926925925925 923924 920 918919921922923923920916917918919 91592091691791891962 LF OF 10" PVC @ 2.00%55 LF OF 10" PVC @ 2.00%10" PVC STORM SERVICEINV=922.50SEE PLUMBING PLANS FOR CONTINUATIONVERIFY LOCATION AND ELEVATION10" PVC STORM SERVICEINV=922.50SEE PLUMBING PLANS FOR CONTINUATIONVERIFY LOCATION AND ELEVATIONFES-1318" INV=919.0089 LF OF 18" RCP @ 0.35%FES-915" INV=919.0013 LF OF 15" RCP @ 0.00%OCS-8RIM=921.9715" INV IN=919.00 (W)12" INV OUT=919.00 (SE)90 LF OF 12" RCP @ 0.35%CBMH-12RIM=921.5612" INV IN=919.31 (S)18" INV OUT=919.31 (NW)FES-515" INV=917.0032 LF OF 15" RCP @ 0.00%OCS-4RIM=922.0015" INV IN=917.00 (SW)12" INV OUT=917.00 (N)191 LF OF 12" RCP @ 0.30%104 LF OF 12" RCP @ 0.48%STMH-3RIM=922.4412" INV IN=914.13 (S)12" INV OUT=914.13 (E)289 LF OF 12" RCP @ 0.42%FES-712" INV=916.53INLINE FILTER SYSTEM►►►►►►►►►►►►►►►►CB-10RIM=922.8712" INV OUT=919.79 (N)34 LF OF 12" RCP @ 0.35%CBMH-11RIM=922.8712" INV IN=919.67 (S)12" INV OUT=919.67 (N)104 LF OF 12" RCP @ 0.35%INLINE FILTER SYSTEM922922 923923 IIIITRENCH DRAINRIM=914.90920 916 917 918 919 921 922 923 92 4 ►►►►►►CBMH-15RIM=921.9860 LF OF 15" RCP @ 0.45%23 LF OF 15" RCP @ 2.81%UNDERGROUND STORMWATERCHAMBER SYSTEMINV=918.00HWL=921.75►►►►►►►►►►►►►►►►►►STMH-20RIM=924.7710" INV IN=921.27 (E)12" INV OUT=920.54 (S)161 LF OF 12" RCP @ 0.50%32 LF OF 15" RCP @ 0.50%INV=918.50INV=918.50925926925925923924920917918919921922915 920 916 917 918919 921 922923924120'40' 920 917918919921920918919921925924920919921920 92 5 921 922 923 924924926 927 9209 2 1 9 2 2922923 DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-501 STORM SEWER PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:53:35 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 1. SEE SHEET C-002 FOR ADDITIONAL PROJECT NOTES.2. UNDERGROUND STORMWATER CHAMBER SYSTEM DETAILS:2.1. ADS STORMTECH SC-740 OR APPROVED EQUAL2.2. 30" TALL CHAMBERS2.3. 120'X40' FOOTPRINT (INCLUDING STONE EMBEDMENT)2.4. BOTTOM OF FOUNDATION STONE=918.002.5. CHAMBER INVERT=918.502.6. TOP OF CHAMBER=921.002.7. TOP OF EMBEDMENT STONE=921.50NOTESC-502ENLARGEDSTORM SEWERPLAN( IN FEET )GRAPHIC SCALE01 inch = 30 ft.306030LEGENDLOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARYEXISTING MINOR CONTOUREXISTING MAJOR CONTOUR►►►►STORM SEWER►►SANITARY SEWERIIWATERMAINSTORM MANHOLESTORM CATCH BASINSANITARY MANHOLEHYDRANTGATE VALVEFLARED END SECTIONEXISTING STORM SEWERPROPOSED MINOR CONTOUR901PROPOSED MAJOR CONTOUR90067 1C-801SILT FENCE MACHINE SLICEDNOT TO SCALE2C-801EROSION CONTROL BLANKET INSTALLATIONNOT TO SCALE4C-801INLET PROTECTION CATCH BASIN INSERTNOT TO SCALE3C-801STABILIZED CONSTRUCTION EXITNOT TO SCALE5C-801SLOPE TRACKING NOT TO SCALEDIRECTION OFSURFACE FLOWANCHOR TRENCH INSTALLATION:1. DIG 6" X 6" TRENCH2. LAY BLANKET IN TRENCH3. STAPLE AT 1.5' INTERVALS4. BACKFILL WITH NATURAL SOIL ANDCOMPACTOVERLAP END JOINTS MINIMUMOF 6" AND STAPLE OVERLAPAT 18" INTERVALSOVERLAP LONGITUDINALJOINTS MINIMUM OF 6"STAPLE DENSITY SHALL BE AMINIMUM OF 3 U-SHAPED 8",11 GAUGE METAL STAPLES PERSQUARE YARD (THIS MAY VARY ASDIRECTED BY THE CITY)ANCHOR TRENCH (SEE DETAILAND NOTES BELOW)ISOMETRICSEE GENERAL NOTESFOR BLANKET TYPESTAPLEBACKFILLEROSIONCONTROLBLANKETANCHOR TRENCH DETAIL6"6"12" TO 36"DIRECTION OF RUNOFFSTEEL FENCE (T-POST) MINIMUM 5'LONG, MAX6' SPACINGATTACH FABRIC TO POST WITH MINIMUM 3 ZIP TIES (50 LB TENSILE) PER POST IN TOP 8" OF FABRICGEOTEXTILE FABRIC OVERLAP FABRIC 6" ANDFASTEN AT 2' INTERVALSLAY FABRIC IN TRENCHFABRIC ANCHORAGE TRENCH BACKFILLTRENCH WITH TAMPED NATURAL SOILSUPPORT POST ANCHORAGE WITHTAMPED NATURAL SOILSECTION6"MIN.24" MIN.POSTEMBEDMENT8"MIN.NOTES:1.FILTER FABRIC SHALL BE PLACED UNDER ROCK TO STOP MUD MIGRATIONTHROUGH ROCK.2.ENTRANCE MUST BE MAINTAINED TO PREVENT SEDIMENTATION ON PUBLICROADWAYS.3.FUGITIVE ROCKS SHALL BE REMOVED FROM ADJACENT ROADWAYS DAILY ORMORE FREQUENTLY AS NECESSARY.ROAD1" - 2" WASHED ROCK18" MIN. CUT OFF BERM TOMINIMIZE RUNOFF FROM SITEISOMETRICISOMETRICCURB AND GUTTEROVERFLOW IS 1/2 OF THECURB BOX HEIGHTDEFLECTOR PLATEOVERFLOW IS 1/2 OF THECURB BOX HEIGHTOVERFLOW AT THE TOP OF THEFILTER ASSEMBLYCURB10" FILTER ASSEMBLYHIGH-FLOW FABRICWIMCO ROAD DRAIN CG-3067 HIGH FLOWINLET PROTECTION CURB AND GUTTERMODEL OR APPROVED EQUAL.NOTES:1.ALL SLOPES WITH A GRADE EQUAL TO OR STEEPER THAN 3:1 REQUIRE SLOPETRACKING.2.SLOPES WITH A GRADE MORE GRADUAL THAN 3:1 REQUIRE SLOPE TRACKING IF THESTABILIZATION METHOD IS EROSION CONTROL BLANKET OR HYDROMULCH.UNDISTURBED VEGITATIONSLOPETRACKED EQUIPMENT TREADSCREATE GROOVES PERPENDICULARTO SLOPE DIRECTIONISOMETRIC6C-801BEDDING METHODS FOR PVC AND HDPENOT TO SCALE7C-801BEDDING METHODS FOR RCP, CMP & DIPNOT TO SCALEPIPE FOUNDATION & BEDDING IN GOOD SOILSPIPE FOUNDATION & BEDDING IN POOR SOILSNOTE:1."D" DENOTES OUTSIDE DIAMETER OF PIPED+12" MIN.6"12"DGRANULAR FILL.MNDOT SPEC. 3149.2.F(MODIFIED - 100%PASSING 3/4 INCHSIEVE)COMPACTED BACKFILLCOARSE FILTER AGGREGATEMNDOT SPEC 3149.2HCOMPACTED BACKFILLDD+12" MIN.12"6"NOTE:1."D" DENOTES OUTSIDE DIAMETER OF PIPE2000# CONCRETECOMPACTED BACKFILLCOARSE FILTER AGGREGATEMNDOT SPEC. 3149.2HCOMPACTED BACKFILLCLASS A (LOAD FACTOR 2.3)CLASS B (LOAD FACTOR 1.9)CLASS C-1 (LOAD FACTOR 1.5)CLASS C-2 (LOAD FACTOR 1.5)COMPACTED BACKFILLCOARSE FILTER AGGREGATEMNDOT SPEC. 3149.2HCOMPACTED BACKFILLDD+12" MIN.D/2D/2 D/2 D/4 BUT NOT LESS THAN 6"D+12" MIN.D+12" MIN.D/2DDDD+12" MIN.D/2D/4 BUT NOT LESS THAN 6"8C-801SANITARY SEWER MANHOLENOT TO SCALEMANHOLE STEPS SHALL BE PLACED SO THATOFFSET VERTICAL PORTION OF CONE ISFACING DOWNSTREAMNEENAH R-1642 FRAME AND COVER OR EQUAL,LETTERED "SANITARY SEWER" WITH 2CONCEALED PICK HOLES AND SELF SEALING LID.27"7"GROUT BOTTOM OF MANHOLE TO 1/2 DIAMETER AT PIPEAND SLOPE GROUT 2" TOWARD INVERT. MORTAR SHALLBE AIR ENTRAINED UNDERGROUND UTILITY MORTARWHICH MEETS OR EXCEEDS ASTM C270 AND ASTM 387.36" - 48"5" MIN.12"VARIES VARIES48" TYP.6"MINIMUM OF 2, MAXIMUM OF 5 CONCRETE ADJUSTMENTRINGS WITH FULL BED OF MORTAR BETWEEN EACH RING. 1RING WITH MORTAR = 0.2'. INTERIOR I&I BARRIER (EULL'SOR APPROVED EQUAL) SHALL BE INSTALLED INSIDE THECASTING AND ALL ADJUSTMENT RINGS. ALTERNATEINFILTRATION BARRIER SYSTEMS MUST BE APPROVED BYENGINEER. ONLY PLASTIC SHIMS SHALL BE ALLOWED IFNEEDED. ALL INFILTRATION AREAS SHALL BE REPAIREDUNTIL MANHOLE IS WATER TIGHT.MANHOLE STEPS, COPOLYMER POLYPROPYLENE PLASTIC, WITH1/2" GRADE 60 STEEL REINFORCEMENT OR EQUAL, 16" O.C.ALL JOINTS IN MANHOLE TO HAVE PROFILE GASKETS PERASTM C443PROVIDE EXTERNAL NEOPRENE SEAL ON ALL JOINTS(GATOR WRAP OR APPROVED EQUAL)PIPE SHALL BE CUT 2" FROM INSIDE FACE OF WALLKOR-N-SEAL MANHOLE CONNECTOR OR APPROVEDEQUAL. ALL DOG HOUSES SHALL BE GROUTED ONINSIDE AND OUTSIDE.MINIMUM THICKNESS OF PRECAST BASE IS 6" FORSTRUCTURES 14" DEEP OR LESS, AND INCREASES 1" INTHICKNESS FOR EVERY 4' OF DEPTH GREATER THAN14'. REINFORCE IN ACCORDANCE WITH MNDOTSTANDARD PLATE 4011E.PLANSECTIONPRECASTREINFORCEDMANHOLEDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:54:07 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:54:07 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2 C-801DETAILS68 6C-802STORM SEWER MANHOLENOT TO SCALE7C-802CATCH BASIN MANHOLENOT TO SCALE8C-80224"X36" CATCH BASINNOT TO SCALE7"VARIES 12"36" - 48"5" MIN.27"VARIES48" TYP.3"AC2VARIES48" TYP.5" MIN.3"VARIES 12"PIPEDIA.B A3"24" 12" 6"24" X 36"5" MIN.6" MIN.36" MIN.BACK OF CURBGROUT BOTTOM OF MANHOLE TO A MINIMUM OF 1/2DIAMETER AT PIPE AND SLOPE GROUT 2" TOWARD INVERT.MANHOLE STEPS SHALL BE PLACED SO THATOFFSET VERTICAL PORTION OF CONE IS FACINGDOWNSTREAM FOR ALL PIPES UP TO 24''. PLACESTEPS ON RIGHT HAND SIDE WHEN FACING DOWNSTREAM FOR ALL PIPES 24'' AND OVERNEENAH R1642 FRAME AND COVER OR EQUALLETTERED, "STORM SEWER", WITH 2 CONCEALEDPICK HOLESMINIMUM OF 2 MAXIMUM OF 5 CONCRETEADJUSTMENT RINGS WITH FULL BED OF MORTARBETWEEN EACH RING. 1 RING WITH MORTAR = 0.2'.INSTALL INTERNAL I&I BARRIER EULL'S ORAPPROVED EQUAL. ONLY PLASTIC SHIMS SHALL BEALLOWED IF NEEDED. MORTAR SHALL BE AIRENTRAINED UNDERGROUND UTILITY MORTARWHICH MEETS OR EXCEEDS ASTM C270 AND ASTMC387.MANHOLE STEPS, COPOLYMER POLYPROPYLENEPLASTIC, WITH 1/2" GRADE 60 STEELREINFORCEMENT OR EQUAL, 16" ON CENTER. (NOSTEPS ALLOWED IN UPPER 27" BARREL.)ALL JOINTS IN MANHOLE TO HAVE PROFILEGASKETS PER ASTM C443PIPE SHALL BE CUT OUT 2" FROM INSIDE FACE OFWALL.MINIMUM SLAB THICKNESS 6" FOR STRUCTURES 14'IN DEPTH OR LESS. INCREASE THICKNESS 1" FOREACH ADDITIONAL 4' OF DEPTH, AND REINFORCE INACCORDANCE OF MNDOT STANDARD PLATE 4011E.MINIMUM OF 2 MAXIMUM OF 5 CONCRETEADJUSTMENT RINGS WITH FULL BED OF MORTARBETWEEN EACH RING. 1 RING WITH MORTAR = 0.2'.INSTALL INTERNAL I&I BARRIER EULL'S ORAPPROVED EQUAL. ONLY PLASTIC SHIMS SHALL BEALLOWED IF NEEDED. MORTAR SHALL BE AIRENTRAINED UNDERGROUND UTILITY MORTARWHICH MEETS OR EXCEEDS ASTM C270 AND ASTMC387.6" MIN. PRECAST REINFORCED CONCRETE MANHOLESLAB, REINFORCED IN ACCORDANCE WITH MNDOTPLATE 4020.TOP OF BARREL SECTION UNDER TOP SLAB TOHAVE FLAT TOP EDGE SEALED WITH 2 BEADS OFRAMNEK OR APPROVED EQUAL. EXTERNAL WRAP(GATOR WRAP OR APPROVED EQUAL) REQUIREDALL JOINTS IN MANHOLE TO HAVE PROFILEGASKETS PER ASTM C4434" PVC DRAINTILE CONNECTION (IF IDENTIFIEDON THE PLANS). PIPE SHALL BE CUT OFF 2"FROM INSIDE FACE OF WALL.MINIMUM SLAB THICKNESS 6" FOR STRUCTURES 14' INDEPTH OR LESS. INCREASE THICKNESS 1" FOR EACHADDITIONAL 4' OF DEPTH, AND REINFORCE INACCORDANCE OF MNDOT STANDARD PLATE 4011E.GROUTCATCHBASIN CASTING NEENAHR3067-V-VB OR EQUALFACE OF CURBMINIMUM OF 2 MAXIMUM OF 5 CONCRETEADJUSTMENT RINGS WITH FULL BED OF MORTARBETWEEN EACH RING. 1 RING WITH MORTAR = 0.2'.INSTALL EXTERIOR INFI-SHIELD OR APPROVEDEQUAL.ONLY PLASTIC SHIMS SHALL BE ALLOWED IFNEEDED. MORTAR SHALL BE AIR ENTRAINEDUNDERGROUND UTILITY MORTAR WHICH MEETS OREXCEEDS ASTM C270 AND ASTM C387.4'' PVC DRAINTILE CONNECTION (IFINCLUDED ON PLANS)GROUT TO HALF DIA. OF PIPE4" PVC DRAINTILE CONNECTION (IFIDENTIFIED ON PLANS). NO BENDSGREATER THAN 45° SHALL BE ALLOWEDDOG HOUSES MUST BE GROUTED BOTH INSIDE ANDOUTSIDE OF STRUCTURE. WASTERSTOP GROUTRING (RCP) OR WATERTIGHT BOOT (PVC) REQUIREDGROUTDOG HOUSES MUST BE GROUTED BOTH INSIDE ANDOUTSIDE OF STRUCTURE. WASTERSTOP GROUTRING (RCP) OR WATERTIGHT BOOT (PVC) REQUIRED4" PVC DRAINTILE (IF IDENTIFIED ON THE PLANS). NOBENDS GREATER THAN 45° SHALL BE ALLOWEDDOG HOUSES MUST BE GROUTED BOTH INSIDE ANDOUTSIDE OF STRUCTURE. WASTERSTOP GROUTRING (RCP) OR WATERTIGHT BOOT (PVC) REQUIREDORIENT GRATEWITH DIRECTION OFFLOWEDGE OF GUTTERFLOWPLANSECTIONPLANSECTIONCLPLANSECTIONNOTES:1.22" BREAKOFF SECTION2.LEFT HAND OPERATING NUT (1 1/2"POINT TO FLAT)3.PAINT BARREL SECTION RED TOGRADE4.PLUG DRAIN HOLES ONLY IFDIRECTED BY CITY ENGINEER5.SEE DETAIL WAT-01 FORINSTALLATION DETAILSNOZZLE ARRANGEMENT(THREE TOTAL)·(2) 2 1/2" NOZZLES, PLUS·(1) 5" STORZ PUMPER NOZZLENORMAL GROUND LINENOTE:HYDRANT SHALL BE PACER MODEL WB67-2503'STAINLESS STEEL BRACKET TOPERMANENTLY SECURE ACCESSBOX TO GRADE FLANGE1.ABOVE GROUND TEST STATIONSHALL BE COBRA T3 (T2-R75) ORAPPROVED EQUAL. OUTDOORRATED PVC CONDUIT SHALL BEINSTALLED FROM BOTTOM OFTEST STATION TO 2' BELOWFINISH GRADE.2.INSTALL TRACER WIRE TOMIDDLE TERMINAL3.INSTALL GROUNDING ANODEWIRE TO BOTTOM TERMINAL4.CONNECT JUMPER BETWEENMIDDLE AND BOTTOM TERMINAL3.0'3'5'#12 AWG COPPER CLAD STEELCORE WIRE WITHMIN. BREAK LOAD OF 270 LBSFOR OPEN CUT INSTALLRATED FOR 30 VOLTS.45 MIL HMWPE JACKET.NOTES:1.FACTORY INSTALLED PLUGS REQUIRED WHENEVER HYDRANTS ARE INSTALLED IN AREAS WITH HIGHGROUNDWATER LEVEL, AS DETERMINED BY DEWATERING REQUIREMENTS AND THE CITY ENGINEER.THE MAIN NOZZLE SHALL BE PAINTED BLUE FOR ALL HYDRANTS WITH PLUGGED DRAIN HOLES.2.ALL DUCTILE IRON WATERMAIN FITTINGS SHALL BE FUSION BONDED EPOXY COATED.3.HYDRANTS SHALL BE MARKED WITH STAINLESS STEEL TAG FROM FACTORY.4.CONTRACTOR SHALL SUPPLY TWO HYDRANT FLAGS, ONE TO BE INSTALLED ON THE HYDRANT ANDTHE SECOND DELIVERED TO CORCORAN PUBLIC WORKS.5.ALL HYDRANT LEADS ARE TO BE CONSTRUCTED WITH POLYWRAPPED DIP, CLASS 52.6.PROVIDE POLYWRAP UP THE HYDRANT BARREL TO THE BREAK OFF FLANGE.7.ALL WATERMAIN BOLTS SHALL BE COR-BLUE OR APPROVED EQUAL.8.HYDRANTS SHALL BE PAINTED IN ACCORDANCE WITH THE FOLLOWING SCHEDULE: FLOW RATE OF1,000 GPM OR MORE - GREEN; FLOW RATE BETWEEN 500 GPM AND 1,000 GPM - YELLOW; FLOW RATEOF 500 GPM OR LESS - RED.9.ABOVE GROUND TEST STATION SHALL BE COBRA T3 (T2-R75) OR APPROVED EQUAL. OUTDOORRATED PVC CONDUIT SHALL BE INSTALLED FROM BOTTOM OF TEST STATION TO 2' BELOW FINISHGRADE. SEE DETAIL WAT-11 FOR CONNECTION DETAILS.10.MIN 1 LB. DRIVE IN ANODE WITH MIN. 20' WIRE LEAD.11.CONNECTORS SHALL BE DRY CONN DIRECT BURY LUG AQUA, PRO-TRACE DB OR APPROVED EQUAL12.CONTRACTOR SHALL SUPPLY 1 HYDRANT WRENCH FOR EVERY PHASE OR EVERY 5 HYDRANTSINSTALLED, WHICHEVER IS GREATER.7.5' MIN.TOP1'CONNECTTRACER WIRETO MAINTRACER WIREGROUNDING ANODE(MIN 3' BURY)ABOVE GROUND TESTSTATION.GATE VALVEEXTENSION RODVERIFY THREAD TYPEWITH FIRE DEPT.WATEROUS PACERMODEL WB-67-250 HYDRANTHYDRA-FINDER TYPEHYDRANT FLAG1.5 CUBIC YARDS GRAVELOR CRUSHED ROCK.COVER WITH POLYETHYLENEWRAP8" CONCRETE BLOCKTIE ALL FITTINGS WITH MIN. OF TWO, 3/4" DIAMETER RODS(STAINLESS STEEL OR EPOXY COATED), OR WITH MEGALUGSWATER7.5' MINIMUM COVER REQUIRED OVERTOP OF WATER MAIN.DROP LIDTYLERMUELLERBIBBY-STE-CROIXNo. 6860 No.H-10361 No.B-5160ADJUST TOP TO 1/2" BELOW GRADE. BOX TOBE SET TO PROVIDE 12" OF ADJUSTMENT.GRADEGATE VALVE BOX·SCREW TYPE,·3 PIECE,·5 1/4" SHAFT,·SIZE G BOX,·7'-6" EXTENDED,·#6 ROUND BASETYLER NO. 6860MUELLER NO. H-10357BIBBY-STE-CROIX B-5001ALL VALVE BOX COMPONENTSSHALL BE MANUFACTURED IN THEU.S. OR CANADA, OR AS APPROVEDBY THE CITY ENGINEER.RESILIANT WEDGE VALVECONFORMING AWWA C-509-80STANDARDS INSTALLED WITH A VALVEBOX ADAPTER TYPE II.8" CONCRETE BLOCKNOTE:ALL WATERMAIN BOLTS ARE TO BE COR-BLUE OR AN APPROVED EQUALTOPTYLERMUELLERBIBBY-STE-CROIXNo. 6860H-10361VB50226"26"27"MUELLERTYLERNo. 58No. 59No. 60No. 58No. 5914"18"24"14"20"BIBBY-STE-CROIXVB520VB521VB522VB523No. 57No. 58No. 59No. 609"14"20"26"BOTTOMTYLERMUELLERBIBBY-STE-CROIXNo. 6860H-10361VB51665"65"60"ADAPTOR REQUIRED ON ALL GATEVALVESEXTENSIONS REQUIRED ON ALLGATE VALVESEXTENSION SHALL BE WITHIN 1-2'OF FINISHED GRADECOPPER TRACER WIREINSTALLED ON ALL PVCWATER MAINMEGALUGS (TYP)GATE VALVE ADAPTOR 1/4" STEELWITH PROTECTIVE COATINGBASEEXTENSION1/2" RUBBER GASKET INSTALLEDBETWEEN THE GATE VALVE ANDGATE VALVE ADAPTORNUT CAPWITHCHAIN5" PUMPER CONNECTION (STORZ NOZZLE)2 1/2" HOSE CONNECTION(THREAD SIZE 3.062" O.D., 7 1/2 TPI)NOZZLE SECTIONHYDRANT LOCATORSUPPLIED W/EACH HYDRANT3322112'-0"1'-6"D2'-8"2'-1"B90° BEND1'-6"1'-5"D2'-1"1'-5"B45° BEND1'-5"1'-5"D1'-5"1'-5"B22 1/2° BENDBUTTRESS DIMENSIONS8"6"SIZEPIPEB1B23SECTION A-AAAAAAAAAAB90°6"16"20"24"3'-0"3'-6"4'-4"2'-0"2'-8"3'-0"3'-10"5'-6"6'-10"3'-0"3'-4"3'-10"6'-2"8'-4"9'-8"3'-6"4'-0"5'-0"2'-6"4'-9"2'-0"3'-4"1'-10"1'-10"12"6'-0"17'-0"6'-0"9'-3"--30"321C1,C2,C3NOTE: ALL WATERMAIN BOLTS SHALL BE COR-BLUE OR APPROVED EQUALNOTES:1.SHAPE OF BACK OF BUTTRESSMAY VERY AS LONG AS POUREDAGAINST FIRM UNDISTURBEDEARTH.2.DIMENSION C1, C2, C3 SHOULDBE LARGE ENOUGH TO MAKEANGLE Ø EQUAL TO OR LARGERTHAN 90°.3.DIMENSION A1, A2, A3 SHOULDBE AS LARGE AS POSSIBLEWITHOUT INTERFERING WITH MJBOLTS.4.ANGLE SHALL BE 45° MINIMUM.5.PLACE POLYETHYLENEBETWEEN CONCRETE & PIPE.6.MEGALUGS SHALL BE INSTALLEDON ALL BENDS.APLAN 3 WAY TEES4 x DIAD1,D2,D3 3'Min.VARIABLECONCRETEUNDISTURBED EARTHBEDDING MATERIALCONCRETE SHALL BE IN CONTACTWITH THIS QUADRANT OF PIPE∠=(SEE NOTE 4)PLAN 22 1/2° BENDSPLAN 45° BENDSPLAN 90° BENDS∠=(SEE NOTE 4)∠=(SEE NOTE 4)∠=(SEE NOTE 4)NOTE:1.ALL FITTINGS SHALL BE FUSION BONDED EPOXY COATED DUCTILE IRON TO MEET OREXCEED ANSI/AWWA C550 AND C116/A21.116 REQUIREMENTS.2.MEGALUGS, IF USED SHALL BE SNUG FIT ON CIP WATER MAIN AND SHALL BOLTS SHALLNOT BE "SNAPPED" TIGHT.3.SELECT GRANULAR WILL BE REQUIRED BETWEEN INSULATION, WATER MAIN, ANDOBSTRUCTION.4.ALL BENDS SHALL HAVE MEGALUGS OR TIE RODS WITH BLOCKING.5.COPPER TRACER WIRE SHALL BE USED ON PVC WATERMAIN.6.ALL WATERMAIN BOLTS SHALL BE COR-BLUE OR APPROVED EQUAL.MIN. 2'-0' MIN 7.5' SEE PLAN GRADE45° BENDMINIMUM 4" INSULATIONOBSTRUCTIONMECH.COMPACTEDSELECT GRANULARVARIABLE PVCWATER MAIN3/4" STAINLESS OR EPOXYCOATED TIE RODS, ORMEGALUGSSELECT GRANULAR3/4" STAINLESS OR EPOXYCOATED TIE RODS, ORMEGALUGS.45° BEND3/4" STAINLESS OREPOXY COATED TIERODS, ORMEGALUGS.6"CL3C-802TYPICAL HYDRANT INSTALLATIONNOT TO SCALE5C-802HYDRANTNOT TO SCALE2C-802GATE VALVE AND BOX INSTALLATIONNOT TO SCALE1C-802CONCRETE THRUST BLOCKINGNOT TO SCALE4C-802WATER MAIN OFFSETNOT TO SCALEDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:54:34 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:54:34 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2 C-802DETAILS69 1C-80327" Ø CATCH BASINNOT TO SCALE2C-803RCP FLARED END SECTION AND TRASH GUARDNOT TO SCALE3C-803RIPRAP AT OUTLETSNOT TO SCALE5C-803CONCRETE TRENCH DRAINNOT TO SCALE5" MIN.27" DIA.3"VARIES 5DDH6"24" MAX.36" MIN.TIE LAST 3 PIPE JOINTS. USE 2 TIE BOLT FASTENERSPER JOINT. INSTALL AT 60° FROM TOP OR BOTTOMOF PIPE. FOR PIPES SEGMENTS WITH FES ON BOTHENDS, ALL PIPE SEGMENTS SHALL BE TIEDPROVIDE 3 ANCHOR CLIPS TO FASTEN TRASHGUARD TO FLARED END SECTION. HOT DIPGALVANIZE AFTER FABRICATION.RIPRAP (PERTABLE BELOW)RIPRAPRIPRAPGEOTEXTILE FILTER-TYPE IVGEOTEXTILE FILTER-TYPE IVPRECAST REINFORCEDCONCRETE STRUCTUREMINIMUM SLAB THICKNESS6" FOR STRUCTURES 14' INDEPTH OR LESS. INCREASETHICKNESS 1" FOR EACHADDITIONAL 4' OF DEPTH,AND REINFORCE INACCORDANCE OF MNDOTSTANDARD PLATE 4011E.MINIMUM OF 2 MAXIMUM OF 5CONCRETE ADJUSTMENTRINGS WITH FULL BED OFMORTAR BETWEEN EACHRING. 1 RING WITH MORTAR =0.2'. INSTALL INTERNAL I&IBARRIER EULL'S ORAPPROVED EQUAL. ONLYPLASTIC SHIMS SHALL BEALLOWED IF NEEDED.MORTAR SHALL BE AIRENTRAINED UNDERGROUNDUTILITY MORTAR WHICHMEETS OR EXCEEDS ASTMC270 AND ASTM C387.6" MNDOT CLASS 5AGGREGATE BASE, 100% CRUSHEDSUBGRADE PREPARATIONNEENAH R-4990-CX TRENCHDRAIN W/ TYPE P GRATE#4 EPOXY COATED DEFORMED BARPROVIDE 3" CLEAR COVERCONCRETE TRENCHGROUT. SLOPE IN ONEDIRECTION TOWARD PIPERIPRAP TO EXTEND 2FEET AWAY FROM ANDBACKWARD 2 FEET FROMLIP OF FES (TYP.)BBAA4114ISOMETRICPLAN(ONE CUBIC YARD IS APPROX. 2,800 LBS)SECTION A-ASECTION B-BSLOPE BOTTOM OF TRENCH TOWARDDISCHARGE POINT AT 1% (TYP.)FLOWFLOWSLOPE 1%SECTIONPROFILEDRAIN45° PVC BENDOUTFLOW6C-806CURB TRANSITION AT CATCH BASINNOT TO SCALE7C-803ACCESSIBILITY SYMBOLNOT TO SCALEVARIES 1 0 ' M IN IMUM TRANS IT IONFLOW(TYP.)FLOW 1 0 ' M IN IMUM TRANS IT IONEXPANSION JOINTAASECTION A-ATOP OF CURB10' MIN TRANSITION2"EXPANSION JOINT NO SCALE10' MIN TRANSITIONEXPANSION JOINTNOTES:1.AFTER INSTALLATION OF CURB &GUTTER, ENSURE EROSIONCONTROL MEASURES AREPROPERLY ESTABLISHED.2.TRANSITION SURMOUNTABLECURB & GUTTER INTO B618 TYPECURB & GUTTER AS ITAPPROACHES CATCH BASIN.3.DEPRESS CATCH BASIN 2" BELOWGUTTER LINE DESIGN GRADE.SURMOUNTABLE CURB(SEE STANDARD PLATESTREET 5 FOR DETAIL)CATCH BASIN FRAME & GRATENEENAH R-3067 V OR APPROVEDEQUALUSE BI-DIRECTIONAL CASTINGS ATLOW POINTS AND UNI-DIRECTIONALCASTINGS AT OTHER LOCATIONS2 #4-120"REBARS (TYP)GUTTER LINE DESIGN GRADEFRAME & CASTING2 #4-120" REBARS (TYP)ISOMETRIC11" 5 "R13"R1 8 " R 24"24"18"10"5" (TYP)20"9.0°12"1' 6 3/4"26"4"4"6"BLUE HIGHWAY PAINTBACKGROUND 2 COATS (TYPICAL)INTERNATIONAL SYMBOL OFACCESSIBILITYAPPLIED TO THE CENTER OF EACHREQUIREDACCESSIBLE SPACE WITH BLUE PAINTBACKGROUNDAND WHITE PAINT FOR SYMBOL ANDPERIMETER EDGE5" WIDE WHITE STRIPING2 COATS (TYPICAL)FILL POST WITH CONCRETEMOUND SMOOTHLY AT TOP6" SCH. 40 STEEL PIPE FILLED W/ CONCRETEPROVIDE YELLOW IDEAL-SHIELD SLEEVEOVER PIPESLOPE TOP OF CONCRETESET POST IN CONCRETE36"24"6"12"4C-803BOLLARDNOT TO SCALEDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:54:47 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:54:47 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2 C-803DETAILS70 11C-804TYPICAL POND SECTIONNOT TO SCALE10'10H:1V SAFETY BENCHAREA TO BE SEEDED WITH BWSR W4MIX AND COVERED WITH CAT 1S ECB.NO POLY NET ALLOWEDBOTTOM:NORTH POND=914.00SOUTH POND=913.003H:1V4H:1V 14"7"136"6"1312"6.25% SLOPETOP OF BITUMINOUS MATERIAL3" R12 " R12" R12"18" B61812" B61224" B6246" CLASS 5AGGREGATE BASE(100% CRUSHED)8"3C-804CONCRETE CURB AND GUTTERNOT TO SCALE7C-804CONCRETE CURB AND GUTTER - TIP OUTNOT TO SCALE9C-804MEDIUM DUTY BITUMINOUS PAVEMENTNOT TO SCALE8C-804CONCRETE SIDEWALKNOT TO SCALE6C-804CONCRETE DRIVEWAY APRONNOT TO SCALE5C-804SIGN POSTNOT TO SCALE4C-804STANDARD PARKING LOT SIGNSNOT TO SCALE2C-804TYPICAL PAVEMENT MARKINGSNOT TO SCALE1C-804ACCESSIBILITY STRIPINGNOT TO SCALETOP OF BITUMINOUSMATERIAL12" R3" R136"12 " R6"1212"6" CLASS 5 AGGREGATEBASE (100% CRUSHED)MATCHROAD SLOPE12"8"7"18" B61812" B61224" B624COMPACTED SUBGRADE4" CONCRETE PAVEMENT (TYPE 3F52A)4" MNDOT CLASS 5 AGGREGATE BASE(100% CRUSHED)COMPACTED SUBGRADE2" BITUMINOUS WEAR COURSE(SPWEA340B) PER MNDOT 23608" MNDOT CLASS 5 AGGREGATEBASE (100% CRUSHED)BITUMINOUS TACK COATPER MNDOT 23572" BITUMINOUS NON-WEAR COURSE(SPNWA340B) PER MNDOT 2360SECTION A-AAPLANW18"VARIES - SEE PLANA6.25% GRADE6" X 6" #6 WELDED WIREMESH6" CLASS 5 BASE6" CONCRETEPAVEMENTCONTROL JOINTSMAX SPACING 8'EXPANSION JOINT (TYPICAL)NO SCALENO SCALE3"MIN 1% GRADEVARIES - SEE PLAN18"NOTES:1.CONTROL JOINT SPACING SHALL BE A MAXIMUM OF 12 FEET.ASPECT RATIO BETWEEN L AND W SHALL NOT EXCEED 1.5:1.B618 CURBANDGUTTERR25'R 2 5 'POUR CURB INTEGRALWITH CONCRETE SLABPOUR CURB INTEGRAL WITHCONCRETE SLAB20"-0"OR AS REQUIRED4"15"2'-8"2'-8"9"15"4"4"15"28"8"TYPICALPAVEMENT STRIPINGTRAFFIC ARROWTYPICAL LETTERNOTES:1.PAINT SHALL BE APPLIED AT A THICKNESS OF 22 WET MILS AND 15 DRY MILS.2.PAINT SHALL BE NON-REFLECTIVE WHITE PAINT FOR ALL TYPICAL PAVEMENTMARKINGSTYPICALCROSSWALK PANEL5'2'STOPDO NOTENTERPARKINGVEHICLE IDREQUIREDUP TO $200 FINE FORVIOLATIONVANACCESSIBLER5-130"X30"W11A-224"X24"R1-130"X30"ACCESSIBLE PARKING - 12"x18"VAN ACCESSIBLE - 12"x6"ORR1-5C18"X24"3/8" DIA. HEX HEAD BOLTW/ HEX NUT AND WASHERS2 1/4" 12 GA.1' - 6"5' - 6"6"2 1/2" 12 GA.FINISHEDGRADEVANACCESSIBLERESERVEDPARKINGSIGNAGE OTHERTHAN ACCESSIBLE(PED XING, STOP, ETC.)GALVANIZEDSQUARE TUBEUSE 6" SCH. 40 STEEL PIPEFILLED W/ CONCRETE WITHTOP ROUNDED BLUE IDEALSHIELD ONLY WHEN SIGN IS INPAVED AREA OR SIDEWALK.SLOPE TOP OFCONCRETESEE BREAK AWAY TUBEPOST WHEN PIPE BOLLARDIS NOT REQUIRED3500 P.S.I. P.C.CONCRETE1'-6"BACK OF CURB OR EDGE OF SIDEWALK 1'-0"4'-0"3" MIN.4'-0"5'-0" (MIN) 5'-6" (MAX)NOTES:1.ALL SIGNS SHALL COMPLY WITH U.S.DEPARTMENT OF TRANSPORTATION,FEDERAL HIGHWAY ADMINISTRATION'S"MANUAL OF UNIFORM TRAFFICCONTROL DEVICES", LOCAL CODES ANDAS SPECIFIED. MOUNT SIGNS TO POST INACCORDANCE WITH MANUFACTURER'SINSTRUCTIONS.2.GALVANIZED SQUARE TUBE SHALL BE2"x2"X3/16" 14GA. POST TUBE SHALLMEET ASTM A1011 GRADE 50. POST TUBEGALVANIZED PER ASTM A653 GRADE 90.HEAVY DUTY ANCHOR TUBE SHALL BE2-1/4"x2"-1/4"x3/16" 14GA. ANCHOR TUBESHALL MEET ASTM A500 GRADE B.STRUCTURAL TUBE AND STEEL SHALL BEHOT DIP GALVANIZED PER ASTM A1233.THE UPPER SIGN POST SHALLTELESCOPE INSIDE THE ANCHOR TUBE AMINIMUM OF 12". THE ANCHOR TUBESHALL BE A MINIMUM OF 38" DEEP WITH3" MIN. 4" MAX EXPOSED ABOVE FINISHGRADE.BREAK AWAY TUBE POST2'4"ACCESSIBILITYSYMBOL, SEE DETAILNO PARKINGNOTES:1.STRIPING ADJACENT TO HANDICAP PARKING SHALL BE BLUE.2.DIMENSION HANDICAP SYMBOLS PER INTERNATIONAL SYMBOL OF ACCESSIBILITY DETAIL.3.SEE PLAN FOR STALL DIMENSIONS.4.DIMENSION "NO PARKING" TO BE 1' TALL.5.SIGNAGE AND MARKINGS TO BE IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS.SIDEWALKSEE SITE PLAN ANDGRADING PLANSIGN POST 1' OFF BACK OF CURB OR SIDEWALKEDGE. SEE SITE PLAN FOR PLACEMENT1'1'SEE PLANINV: SEE PLANINV: SEE PLANCONCRETE WEIRPROFILE VIEWMONOLITHICALLYPOURED BOTTOMPLAN VIEWRIM ELEV: SEE PLANWEIRINLET P IPE OUTLE T PIPENOTES:1.MANHOLE SHOULD BE CONSTRUCTED AND INSTALLED IN ACCORDANCEWITH STORM MANHOLE STRUCTURE DETAIL 6/C-802OUTLET PIPEINLET PIPE4"10C-804OUTLET CONTROL STRUCTURE (OCS)NOT TO SCALEORIFICE3" INV=917.00 (OCS-4)3" INV=919.00 (OCS-8)6" INV=918.00 (OCS-16)NWL:NORTH POND=919.00, SOUTH POND=917.00HWL:NORTH POND=920.76, SOUTH POND=921.75TOP OF WEIREL=921.70 (OCS-4)EL=920.80 (OCS-8)EL=920.00 (OCS-16)DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:55:01 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:55:01 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2 C-804DETAILS71 918.00921.00918.50921.50NATIVE SUBGRADEADS STORMTECH SC-740 CHAMBER SYSTEM8 ROWS WIDE X 16 CHAMBERS LONG6"30"6"VARIES (~924-926)BITUMINOUS PAVEMENT SECTIONEMBEDMENT STONE120' X 40' FOOTPRINT40'1C-805UNDERGROUND STORMWATER CHAMBER SYSTEMNOT TO SCALEDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:55:11 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2DWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\C-801 DETAILS 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:55:12 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1 12/16/2020 CITY SUBMITTAL 2 C-805DETAILS72 NE STINSON PKWYALLEY 4-STORYSENIOR LIVING BUILDINGFFE=926.00LLE=915.00►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►►IIIIIIIIIIIIII I I I I I I I IIIIIII IIIIIIIIIIIII I I I IIIIIIIIIIIIIIIIIIIIIIIIIIIII►►►►►►►►►►►►►►►►►►(1) SR(2) SR(2) SR(1) SR(1) SR(1) SR(1) SR(2) OV(1) OV(1) OV(1) CO(2) TA(3) PF(2) PF(2) PS(1) AC(1) AC(9) PM(5) HA(5) HA(4) HA(5) HA(5) HA(4) HA(2) HA(2) HA(9) HA(6) SJ(3) SJ(3) SJ(3) AM(3) AM(9) AM(1) TA(1) TA(1) TA(1) TA(1) PS(1) OV(2) OV(1) OV(2) AC(2) AC(1) AC(1) AC(2) PF(2) PF(2) PF(1) PF(1) MS(2) MS(1) MS(1) MS(1) MS(1) MS(2) MS(2) MS(1) TA(1) TA(2) TA(1) TA(1) TA(2) OV(1) OV(1) OV(1) CO(3) PF(2) PF(3) PF(3) HA(3) HA(7) NF(7) NF(15) NF(11) NF(37) NF(23) NF(4) ET(4) ET(8) RB(14) RB(8) RB(26) RBCONCRETE PATIOMEMORY GARDENRETAINING WALL,REFER TO CIVIL SHEETS(1) OV(2) HA(1) HA(4) HA(3) HA(3) HA(9) HA(3) SJ(3) AM(3) SJ(2) HA(2) PF(2) MSDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\L-101 LANDSCAPE PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:56:31 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 1. SEE SHEET C-002 FOR ADDITIONAL PROJECT NOTES.NOTESL-101LANDSCAPE PLAN( IN FEET )GRAPHIC SCALE01 inch = 30 ft.306030LOT LINEEASEMENT LINESETBACK LINERIGHT OF WAY LINESECTION LINEQUARTER LINEEXISTING EASEMENT LINEEXISTING PROPERTY LINEPROPERTY BOUNDARYLEGENDDECIDUOUS TREECONIFEROUS TREEORNAMENTALTREESHRUB/PERENNIAL PLANTTURF SEED MIXROCK MULCHTURF PAVERSWETLAND SEED MIX73 L-102NOTES & DETAILSDWN BY:ISSUE DATE:PROJECT NO.:M:\2112 - Kaas Wilson\20-500 St. Anthony Independent Senior Living\DESIGN\CAD\PLANSHEETS\L-101 LANDSCAPE PLAN 2112-20-500.dwg 12/17/2020 ROSHAAN A. GRIEME DESCRIPTION:DATE:ISSUE NO.:ISSUE NO.:SHEET NO.:SHEET TITLE:12/17/2020 10:56:38 AM SUB CONSULTANT:CLIENT:PROJECT TITLE:CHK'D BY: APP'D BY:CERTIFICATION:N O T F O R C O N S T R U C T I O N 7500 OLSON MEMORIAL HWYSUITE 300GOLDEN VALLEY, MN 55427PHONE: 763-252-6800FAX: 952-831-1268WWW.WENCK.COMKAAS WILSONARCHITECTSST. ANTHONY INDEPENDENT SENIOR LIVING 2501 LOWRY AVE ST. ANTHONY, MINNESOTA 554182112-20-500MDH RAG DML12/16/2020211/17/2020 CITY SUBMITTAL 1WARNING:THE CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING FOR LOCATIONS OF ALL EXISTING UTILITIES. THEY SHALLCOOPERATE WITH ALL UTILITY COMPANIES IN MAINTAINING THEIR SERVICE AND/OR RELOCATION OF LINES.THE CONTRACTOR SHALL CONTACT GOPHER STATE ONE CALL AT 651-454-0002 AT LEAST 48 HOURS IN ADVANCE FORTHE LOCATIONS OF ALL UNDERGROUND WIRES, CABLES, CONDUITS, PIPES, MANHOLES, VALVES OR OTHER BURIEDSTRUCTURES BEFORE DIGGING. THE CONTRACTOR SHALL REPAIR OR REPLACE THE ABOVE WHEN DAMAGED DURINGCONSTRUCTION AT NO COST TO THE OWNER.GOPHER STATE ONE CALLTWIN CITY AREA: 651-454-0002TOLL FREE 1-800-252-1166CALL BEFORE YOU DIG12/16/2020 CITY SUBMITTAL 2 1. TREES AND SHRUBS SHALL BE PROVIDED IN THE QUANTITY, SIZE, GENUS, SPECIES, AND VARIETY ASCHOSEN BY THE OWNER/OWNER AS LISTED ON THE LANDSCAPE PLAN L 101.2. TREES AND SHRUBS SHALL BE HEALTHY, VIGOROUS STOCK, GROWN IN RECOGNIZED NURSERY INACCORDANCE WITH GOOD HORTICULTURAL PRACTICE AND FREE OF DISEASE, INSECTS, EGGS, LARVAE,AND DEFECTS.3. OWNER RETAINS THE RIGHT TO INSPECT TREES AND SHRUBS FOR SIZE AND CONDITION OF BALLS ANDROOT SYSTEMS, INSECTS, INJURIES, AND LATENT DEFECTS, AND TO REJECT UNSATISFACTORY ORDEFECTIVE MATERIAL AT ANY TIME DURING PROGRESS OF WORK.4. NURSERY STOCK SHALL BE DELIVERED DIRECTLY FROM NURSERY. HEEL IN IMMEDIATELY UPONDELIVERY IF NOT TO BE PLANTED WITHIN FOUR HOURS, COVERING WITH MOIST SOIL OR MULCH TOPROTECT FROM DRYING. STORE PLANTS IN SHADE AND PROTECT FROM WEATHER.5. PROTECTION FROM EXTREMES IN EXPOSURE AND ROUGH HANDLING SHALL BE PROVIDED FOR ALLPLANT MATERIALS DURING TRANSPORT AND STORAGE.6. THE CONTRACTOR SHALL NOTIFY THE OWNER 48 HOURS PRIOR TO PLANTING SO THAT A MUTUALLYAGREEABLE TIME MAY BE ARRANGED FOR INSPECTION.7. LAY OUT INDIVIDUAL TREE AND SHRUB LOCATIONS WITH STAKES CENTERED AT PROPOSED PLANTINGLOCATIONS FOR APPROVAL BY OWNER.8. DO NOT START PLANTING WORK UNTIL LAYOUT IS APPROVED BY THE OWNER.1. UPON APPROVAL OF STAKING LOCATIONS CONTRACTOR SHALL EXCAVATE PLANTING HOLES CENTEREDAT STAKED LOCATIONS.2. DIG HOLES AS DETAILED AND TO A DIAMETER A MINIMUM OF TWO TIMES THE DIAMETER OF THE ROOTBALL OR CONTAINER.3. REMOVE STICKS, RUBBISH, FOREIGN MATERIALS AND UNDESIRABLE PLANTS AND THEIR ROOTS.REMOVE STONES MEASURING OVER 1-1/2 INCHES IN ANY DIMENSIONS.4. SET BALLED AND BURLAPPED (B&B) STOCK ON LAYER OF COMPACTED PLANTING SOIL MIXTURE, PLUMBAND IN CENTER OF PIT OR TRENCH WITH TOP OF ALL AT SAME ELEVATION AS ADJACENT FINISHEDLANDSCAPE GRADES.5. ROOT FLARE OF THE TREE MUST BE ABOVE FINISHED GRADE.6. CUT ALL CORDS AND TWIN AND REMOVE WIRE BASKET AND BURLAP FROM TOP AND SIDES OF BALLS;RETAIN BURLAP ON BOTTOMS.7. WHEN SET, PLACE ADDITIONAL PLANTING SOIL BACKFILL AROUND BASE AND SIDES OF BALL, AND WORKEACH LAYER TO SETTLE BACKFILL AND ELIMINATE VOIDS AND AIR POCKETS.8. WHEN EXCAVATION IS APPROXIMATELY 2/3 FULL, WATER THOROUGHLY BEFORE PLACING REMAINDEROF BACKFILL.9. REPEAT WATERING UNTIL NO MORE IS ABSORBED. WATER AGAIN AFTER PLACING FINAL LAYER OFBACKFILL.10. FOR CONTAINER GROWN STOCK, SAME AS FOR BALLED AND BURLAPPED STOCK, EXCEPT CUTCONTAINERS ON SIDES INTO QUARTERS WITH SHEAR. REMOVE CONTAINER BEFORE SETTING PLANTSO AS NOT TO DAMAGE ROOT BALLS.11. WATER EACH PLANT WITHIN 2 HOURS OF PLANTING.12. ALL PLANTINGS TO BE MULCHED UNLESS OTHERWISE NOTED ON THE PLAN.13. PLACE 4-INCH THICKNESS OF MULCH AROUND TREES AND SHRUBS WITHIN A PERIOD OF 48 HOURSAFTER THE SECOND WATERING.14. DO NOT PLACE MULCH IN DIRECT CONTACT WITH TRUNKS OR STEMS.1. LANDSCAPE WORK WILL BE INSPECTED FOR ACCEPTANCE IN PARTS AGREEABLE TO THE OWNER,PROVIDED WORK OFFERED FOR INSPECTION IS COMPLETE, INCLUDING MAINTENANCE, FOR THEPORTION IN QUESTION.2. AT THE CONCLUSION OF THE ESTABLISHMENT PERIOD, WHICH WILL BE ONE YEAR FOLLOWING INITIALINSTALLATION A FINAL INSPECTION OF PLANTING WILL BE MADE TO DETERMINE THE CONDITIONS OFAREAS SPECIFIED FOR LANDSCAPING.3. WHEN INSPECTED LANDSCAPE WORK DOES NOT COMPLY WITH REQUIREMENTS, REPLACE REJECTEDWORK AND CONTINUE SPECIFIED MAINTENANCE UNTIL RE-INSPECTED BY OWNER AND FOUND TO BEACCEPTABLE. REMOVE REJECTED PLANTS AND MATERIALS FROM SITE.1. WHEN INSPECTED LANDSCAPE WORK DOES NOT COMPLY WITH REQUIREMENTS, REPLACE REJECTEDWORK AND CONTINUE SPECIFIED MAINTENANCE UNTIL RE-INSPECTED BY OWNER AND FOUND TO BEACCEPTABLE. REMOVE REJECTED PLANTS AND MATERIALS FROM SITE.2. BEGIN MAINTENANCE IMMEDIATELY AFTER PLANTING.3. MAINTAIN TREES AND BUSHES INCLUDING WATERING FOR ONE YEAR AFTER ACCEPTANCE BY OWNER.IT IS CONTRACTORS RESPONSIBILITY FOR COORDINATE WATERING.4. TRIM, PRUNE, REMOVE CLIPPINGS AND DEAD OR BROKEN BRANCHES, AND TREAT PRUNED AREAS ANDOTHER WOUNDS.5. IT IS THE CONTRACTOR'S OPTION WHETHER OR NOT TO STAKE TREES. THE CONTRACTOR ISRESPONSIBLE FOR MAINTAINING TREES IN AN UPRIGHT POSITION THROUGHOUT THE ONE-YEARGUARANTEE PERIOD.1. PLANT MATERIAL SHALL BE GUARANTEED FOR ONE FULL YEAR AFTER OWNER ACCEPTANCE AND SHALLBE ALIVE AND IN SATISFACTORY CONDITION AT THE END OF THE GUARANTEE PERIOD. SUCHGUARANTEE EXCLUDES VANDALISM.2. AT THE END OF THE ONE-YEAR GUARANTEE PERIOD, INSPECTION WILL BE MADE BY THE OWNER UPONWRITTEN NOTICE BY THE CONTRACTOR AT LEAST FIVE DAYS BEFORE THE ANTICIPATED DATE. ANYPLANT MATERIAL REQUIRED UNDER THE CONTRACT THAT IS DEAD OR NOT IN SATISFACTORYCONDITION, AS DETERMINED BY THE OWNER, SHALL BE REMOVED FROM THE SITE, AND SHALL BEREPLACED AS SOON AS CONDITIONS PERMIT DURING THE NORMAL PLANTING SEASONS.3. THE OPINION OF THE OWNER SHALL GOVERN IN ANY AND ALL DISPUTES BY THE CONTRACTORREGARDING THE CONDITION AND DISPOSITION OF UNSATISFACTORY MAINTENANCE PROCEDURES ORREJECTED PLANTS.4. ALL REPLACEMENTS SHALL BE PLANT MATERIAL OF THE SAME KIND AND SIZE AS SPECIFIED IN THEPLANT LIST. REPLACEMENT COSTS SHALL BE BORNE BY THE CONTRACTOR.5. REPLACEMENT PLANTINGS REQUIRED AT THE END OF THE GUARANTEE PERIOD ARE NOT TO BEGUARANTEED. THE PLANT MATERIAL IS SUBJECT TO INSPECTION AND REJECTION BY THE OWNERBEFORE AND AFTER PLANTING.1. EDGE RESTRAINT BETWEEN PLANTING BEDS AND TURF SHALL BE BLACK COMMERCIAL GRADELANDSCAPE EDGING BY COL-MET OR APPROVED EQUAL, 6"x12 GAUGE STEEL.2. THE ESTABLISHMENT PERIOD FOR SOD SHALL BEGIN IMMEDIATELY AFTER INSTALLATION, WITH THEAPPROVAL OF THE OWNER, AND CONTINUE UNTIL THE DATE THAT THE OWNER PERFORMS A FINALINSPECTION.3. THE ESTABLISHMENT PERIOD FOR SODDED AREAS IS 1 YEAR.4. SOD SHALL CONFORM TO MNDOT SPEC. 3878.2.A MINERAL SOD; SOD SPECIES COMPOSITION SHALL BEMINNESOTA STATE SEED MIX 25-151 - HIGH MAINTENANCE TURF.5. FERTILIZER SHALL CONFORM TO MNDOT SPEC. 3881, TYPE 2 PHOSPHOROUS-FREE.6. FERTILIZER SHALL HAVE A FORMULA (N-P-K) AS DETERMINED BY THE RESULTS OF A SOIL TEST.CONTRACTOR TO CONDUCT SOIL TEST AND PROVIDE RESULTS ALONG WITH RECOMMENDED FERTILIZERFORMULA TO OWNER FOR REVIEW AND APPROVAL PRIOR TO APPLICATION.7. TOPSOIL SHALL BE IMPORTED AND CONFORM TO MNDOT SPEC. 3877.2B LOAM TOPSOIL BORROW.TOPSOIL SHALL BE SCREENED, PULVERIZED, AND CONTAIN LESS THAN 30% CLAY.8. 6" OF TOPSOIL SHALL BE PLACED IN ALL SEEDING AREAS.9. INSTALLATION OF SOD SHALL OCCUR WITHIN ONE (1) WEEK OF COMPLETING THE GRADING.10. PLACE ALL SOD STRIPS WITH LONG EDGES PARALLEL TO THE CONTOURS. STAGGER ALL JOINTSALTERNATELY WITHOUT SPACE BETWEEN. SECURE THE SOD TO SLOPES WITH BIODEGRADABLE ANCHORSYSTEMS.11. CONTRACTOR SHALL BE RESPONSIBLE FOR WATER DURING THE PLANTING ESTABLISHMENT PERIOD.THE IRRIGATION SYSTEM CONTRACTOR SHALL BE RESPONSIBLE FOR THE FOLLOWING:1. COORDINATION WITH ALL OTHER TRADES.2. DETAILED DESIGN OF AN IRRIGATION SYSTEM FOR THE SITE. THE LIMITS OF THE AREA TO BE IRRIGATEDARE INDICATED ON THE DRAWINGS. DESIGN SHALL INCLUDE PIPE SIZING, HEAD SELECTION, LOCATIONSOF HEADS, ZONING, AND CONTROL SYSTEMS. DESIGN SHALL PROVIDE NO OVERSPRAY ONTO WALKS.IRRIGATION PLAN, DESIGN DETAILS AND PRODUCT SHEETS SHALL BE SUBMITTED TO THE ENGINEER ANDOWNER FOR REVIEW AND APPROVAL PRIOR TO PURCHASING ANY MATERIALS.3. LABOR AND MATERIALS NECESSARY TO INSTALL A NEW IRRIGATION SYSTEM AS SHOWN IN GENERAL ONTHE PLAN. THE IRRIGATION CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR FURNISHING ANDINSTALLING THE IRRIGATION CONTROL SYSTEM ALONG WITH ANY CONNECTIONS MADE TO THE WATERSERVICE.4. TESTING OF THE COMPLETE IRRIGATION SYSTEM.5. STARTUP AND ADJUSTMENT OF THE SYSTEM.6. PROVIDE OWNER'S EMPLOYEES WITH OPERATIONAL TRAINING ONSITE AND SUBMIT OPERATION ANDMAINTENANCE MANUALS FOR ALL COMPONENTS.7. AS-BUILT DRAWINGS SHOWING THE LOCATION AND FEATURES OF ALL IRRIGATION COMPONENTS.1. ALL WORK AND MATERIALS TO BE IN FULL ACCORDANCE WITH LATEST RULES AND REGULATIONS OF THEDIVISION OF INDUSTRIAL SAFETY, THE UNIFORM PLUMBING CODE, NATIONAL ELECTRIC CODE, AMERICANSWITH DISABILITIES, AND OTHER APPLICABLE LAWS OR REGULATION.2. NOTHING IN THESE DRAWINGS OR SPECIFICATIONS IS TO BE CONSTRUED TO PERMIT WORK NOTCONFORMING TO THESE CODES.3. FURNISH, WITHOUT EXTRA CHARGE, ANY ADDITIONAL MATERIAL AND LABOR AS REQUIRED TO COMPLYWITH THESE RULES AND REGULATIONS, THOUGH THE WORK IS NOT MENTIONED IN THESE PARTICULARCONSTRUCTION DOCUMENTS.1. BECOME ACQUAINTED WITH ALL SITE CONDITIONS. LOCATE EXISTING UTILITIES AND EQUIPMENT TOREMAIN. SHOULD UTILITIES OR OTHER WORK NOT SHOWN ON THE DRAWINGS BE FOUND DURINGEXCAVATIONS, PROMPTLY NOTIFY ENGINEER. FAILURE TO DO SO WILL MAKE CONTRACTOR LIABLE FORANY AND ALL DAMAGE ARISING FROM OPERATIONS SUBSEQUENT TO DISCOVERY OF SUCH UTILITIES NOTSHOWN ON DRAWINGS.2. TAKE NECESSARY PRECAUTIONS TO PROTECT EXISTING SITE CONDITIONS. REPAIR ANY DAMAGED ITEMTO ITS ORIGINAL CONDITION OR FURNISH AND INSTALL EQUIVALENT REPLACEMENT AT NO ADDITIONALCOST TO OWNER.1. THE ENTIRE INSTALLATION SHALL FULLY COMPLY WITH ALL LOCAL AND STATE LAWS AND ORDINANCESAND WITH THE ESTABLISHED CODES ALLOCABLE THERETO.2. THE CONTRACTOR SHALL TAKE OUT ALL REQUIRED PERMITS, ARRANGE FOR ALL NECESSARYINSPECTION, AND PAY ANY FEES AND EXPENSES IN CONJUNCTION WITH THE SAME AS PART OF THEWORK UNDER THIS CONTRACT.1. SCHEDULE AND COORDINATE WORK WITH OTHER TRADES TO FACILITATE WORK AND AVOID CONFLICTS INCONSTRUCTION SEQUENCE AND EQUIPMENT INSTALLATION.2. REVIEW ENTIRE PLAN SET AND COORDINATE WITH OTHER TRADES AS REQUIRED BY SEQUENCE OFCONSTRUCTION TO ENSURE PROVISION OF MAINLINE AND ELECTRICAL CONDUIT STUB-OUTS AT ALLREQUIRED LOCATIONS.LANDSCAPE NOTESTURF RESTORATION NOTESINSPECTION AND ACCEPTANCEPLANTING NOTESMAINTENANCE NOTESGUARANTEE AND REPLACEMENTSCONTRACTORS RESPONSIBILITYCODES AND INSPECTIONQUALITY ASSURANCEPROTECTION OF EXISTING CONDITIONSCOORDINATIONL-102PRUNE ANY DAMAGED OR BROKEN BRANCHES. DONOT CUT LEADER.ROOT FLARE MUST BE ABOVE FINISHED GRADE.DO NOT COVER ROOT FLARE WITH MULCH; MULCHSHOULD NOT TOUCH TRUNK.DOUBLE SHRED, HARD WOOD MULCH (4") MIN.ROUGH THE SIDES OF THE HOLE SO THEY ARE NOTGLAZED FROM DIGGING.LOOSEN SIDES OF ROOT BALL AND PRUNE DAMAGED,DESICCATED, OR GIRDLING ROOTS. REMOVE ALL BURLAPTWINE BEFORE PLANTING.SET ROOT BALL ON SOIL BACKFILL SO THAT TOP OF ROOTBALL IS ABOVE FINISHED GRADE.BACKFILL AROUND THE ROOT BALL WITH LOOSE SOIL. WORKSOIL TO SETTLE AND ELIMINATE VOIDS AND AIR POCKETS.WATER THOROUGHLY WHEN BACKFILLED 2/3 FULL AND ALLOWTO SETTLE.2X ROOT BALL DIA. MINDECIDUOUS TREE PLANTINGSPECIES AS SHOWN ON PLAN1L-102NOT TO SCALECONIFEROUS TREE PLANTING2NOT TO SCALE2X ROOT BALL DIA. MINPRUNE ANY DAMAGED OR BROKEN BRANCHES. DONOT CUT LEADER.ROOT FLARE MUST BE ABOVE FINISHED GRADE.DO NOT COVER ROOT FLARE WITH MULCHDOUBLE SHRED, HARD WOOD MULCH (3") MIN.ROUGH THE SIDES OF THE HOLE SO THEY ARE NOTGLAZED FROM DIGGING.LOOSEN SIDES OF ROOT BALL AND PRUNE DAMAGED,DESICCATED, OR GIRDLING ROOTS.SET ROOT BALL ON SOIL BACKFILL SO THAT TOP OF ROOTBALL IS ABOVE FINISHED GRADE.BACKFILL AROUND THE ROOT BALL WITH LOOSE SOIL.WORK SOIL TO SETTLE AND ELIMINATE VOIDS AND AIRPOCKETS. WATER THOROUGHLY WHEN BACKFILLED 2/3FULL AND ALLOW TO SETTLE.SPECIES AS SHOW ON PLANSHRUB/PERENNIAL PLANTINGROCK MULCH (2") MIN. OR DOUBLESHREDDED HARDWOOD MULCH (3")MIN. MULCH SHOULD NOT TOUCH BASEOF PLANT.COMMERCIAL METAL EDGING, SEEPLANCONTAINER GROW MATERIALS SHALLHAVE ROOTS HAND LOOSENED UPONPLANTINGUNDISTURBED SUBGRADESCARIFY SIDES AND BOTTOM OF ENTIREBED WITH SPADE BY HAND TO BIND WITHPLANTING SOIL6"MINPREPARE SOIL FORTHE ENTIRE BEDPLANTING SOIL18" MIN.SEE PLAN3L-102NOT TO SCALE74 Dear Land Use Applicant: As a part of the Land Use Permit you are seeking, you will be asked to provide funds to cover the City’s expected costs of review and processing of your request. There are two components to this amount. The first is a base fee, which is a non-refundable amount. This fee covers several expenses, including: • The City’s costs of internal review of your application for completeness; • Ensuring that all required materials are available to properly process your request; • Public hearing notices which must be published in the City’s official newspaper (the St. Anthony Bulletin); • Mailed notice to all neighboring property owners within 350 feet of your property; • This base fee also covers a portion of the City’s costs in preparing staff reviews and reports to the appropriate public officials who will consider and ultimately make a decision on your request. For most applications, this includes the Planning Commission, which prepares an advisory recommendation following a formal public hearing on the matter, and the City Council, which makes the final decision. Other public bodies may be involved as well, depending on the exact nature of your request. The second component of the funds is an escrow amount, above the base fee. While the base fee covers most of the fixed expenses, it is common that staff and consultant review will exceed the base fee. To ensure that the costs of extraordinary review are not borne by neighbors, the City requires the escrow from which to draw those costs. You can minimize the amounts necessary to review your application by making sure it is complete and clear. Properly drawn plans and thorough narrative descriptions all help to streamline the City’s processing, which leads directly to lower costs. Following the final decision on your application by the City Council, staff will account for costs and review the escrow. If any funds remain, those will be refunded to you. It typically takes a couple of months to assemble final invoices before the City’s finance department can reconcile the account. The staff works diligently to finalize accounts as soon as possible, so please be patient. If you are curious as to the status of your escrow, feel free to contact City Hall. Before you begin this process, please consider a pre-application conference (by phone, email, or in person) with City community development staff. We are ready to assist in helping you understand the complexities of the review process, and the standards on which a potential application will be considered. We can also advise you on the materials that will help ensure you have a complete and clear application. City of St. Anthony City Hall 612-782-3301 Thanks for your interest in improving your property and reinvesting in the St. Anthony Village community. 75 Our Mission is to be a progressive and livable community, a walkable village, which is sustainable, safe and secure. Address of Property Involved: _________________________________________________________________________ Property ID Number: _________________________________________________________________________________ Legal Description: ___________________________________________________________________________________ __________________________________________________________________________________________________ Applicant Information Applicant Name: ____________________________________________________________________________________ Applicant Address: __________________________________________________________________________________ Applicant Telephone Number: ________________________________ Other: ___________________________________ Applicant Fax Number________________________________________________________________________________ Applicant Email Address: _____________________________________________________________________________ Property Information Property Owner (if different from above):________________________________________________________________ Owner Address: _____________________________________________________________________________________ Owner Telephone Number: ___________________________________________________________________________ Owner Email Address: ________________________________________________________________________________ Type of Request (Check All that Apply) Appeal ($100 fee) Comprehensive Plan Amendment ($750 fee + $1,500 escrow if residential; $3,500 escrow if commercial/industrial) Conditional Use Permit (CUP) ($500 fee+ $450 escrow if residential; $850 escrow if commercial/industrial) Easement Vacation ($200 fee + $500 escrow) Preliminary Plat ($500 fee + $500 escrow) Final Plat ($500 fee + $500 escrow) Minor Subdivision/Lot Split ($250 fee + $1,250 escrow) Planned Unit Development (PUD) ($750 fee + $2,500 escrow) Rezoning ($500 fee + $750 escrow) Zoning Text Amendment ($500 fee + $750 escrow) Site Plan ($250 fee + $450 escrow) Variance ($500 fee + $450 escrow if residential; $850 escrow if commercial/industrial) 3301 Silver Lake Road St. Anthony Village, Minnesota 55418 Office: (612) 782-3301 Fax: (612) 782-3302 www.savmn.com -For Office Use Only- Planning File Number _____________ Project Number _____________ Application Submittal Date _____________ Application Completed Date _____________ Fee Paid _____________ Receipt Number _____________ Planning Commission Meeting Date _____________ Council Decision _____________ Council Decision Date _____________ LAND USE APPLICATION 2501 Lowry Avenue Ne, St Anthony Village, MN 55418 component of 07-029-23-23-0001 See Attached Site Plan Robert Wall - Development 65, LLC 2445 Nevada Avenue North, Golden Valley, MN 55427 310-994-1610 send all correspondence via email. rwall@development65.com The Village LLC 1907 Wayzata Blvd. Suite 250, Wayzata, MN 55391 (952) 473-1700 bahoyt@gmail.com 4 4 76 Description of the Request (OR a separate detailed narrative explaining the project): ________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ Filing and Information Requirements The City recommends that you contact the planner prior to submission to discuss the application process, requirements, and deadlines. Incomplete Applications and Submission Deadline A complete land use application (including all required fees and escrows) must be received at least 30 days prior to the meeting of the Planning Commission or City Council meeting at which the request will be heard. Submission of an incomplete application may delay the processing of your land use request. The application approval time commences and an application is considered officially filed when the City Planner has received and examined the application and determined that the application is complete. A decision on whether the application is complete or incomplete shall be made within fifteen (15) working days following the submittal of the application. When the application is deemed to be “complete” it shall be placed on the agenda of the first possible Planning Commission meeting provided that all required public notices have been sent and published. Upon submission of a complete application, state statute requires that a decision be issued within 60 days regarding each request; however, a 60-day extension may be obtained if more time is needed. Notice of Meeting Attendance In order for the Planning Commission and the City Council to consider any application, the applicant or a designated representative must be present at the scheduled meeting. If not, the matter may be tabled until the next available agenda. Agenda Deadline and Meeting Schedule Planning Commission meetings are typically held on the third Tuesday of every month at 7:00 p.m., while City Council meetings are held typically the second and fourth Tuesday of every month at 7:00 p.m. Meeting dates and times are subject to change so please contact City Hall to verify the meeting date and time. All meetings are held at the St. Anthony Community Center in the Council Chambers, 3301 Silver Lake Road, St. Anthony, Minnesota 55418, unless otherwise stated. Applications are advised that additional meetings and/or workshops are scheduled when necessary. 77 Acknowledgement and Signature I acknowledge that I have read all of the information listed in the City of St. Anthony Village Land Use Application and fully understand that I am responsible for all costs incurred by the City related to the processing of this application. If additional fees are required to cover costs incurred from processing of the application, the City has the right to require additional payment from one or more of the undersigned, who shall be jointly liable for such fees. Such expenses may include (but are not limited to) direct city payroll and overhead costs, fees paid to consultants and other professionals, and the cost of printing, mailing, and supplies. Applicants are advised that an escrow deposit is required at the time of the submittal of the land use application to offset costs associated with the proposed project. Unused portions of an escrow are returned to the applicant upon successful implementation of an approved plan. I understand that approval from other agencies may be required before commencement with the stated project. __________________________________________________ __________________________ Property Owner Signature (Required) Date __________________________________________________ __________________________ Applicant Signature (If different than the property owner) Date Please contact the City Planner at 763-957-1100 or planner@savmn.com if you have any questions regarding this application. Brad Hoyt 11/16/20 Robert Wall 11/16/20 12 12/16/20 12/16/20 78 PAGE 1 OF 1Drawn By: SANDYDate:11/10/2020Scale: AS NOTEDRevisions# Date CommentsGENERAL NOTES:A. PULSE PRODUCTS DOES NOT ASSUME RESPONSIBILITYFOR THE INTERPRETATION OF THIS CALCULATION ORCOMPLAINCE TO THE LOCAL, STATE, OR FEDERALLIGHTNG CODES OR ORDINANCES.B. LIGHTING LAYOUT IS NOT INTENDED FOR CONSTRUCTIONDOCUMENTS BUT ONLY TO ILLUSTRATE THE PERFORMANCEOF THE PRODUCT.C. ALL READINGS/CALCULATIONS SHOWN ARE SHOWN ONOBJECTS/SURFACES.ST. ANTHONY VILLAGEChecked By: ROSSCalculation SummaryLabelCalcTypeUnitsAvgMaxMinAvg/MinLuminaire ScheduleSymbolQtyLabelArrangementLLFDescriptionArr. WattsMax/MinLum. Lumens5AASINGLE0.900RAYON T322LEDB MOUNT ON 25FT POLE WITH 3FT BASE306.238522SITE GROUNDIlluminanceFc1.3318.90.0N.A.N.A.SOUTH PARKINGIlluminanceFc3.7310.84BB1.03.7310.80WEST PARKINGIlluminanceFc2.887.41.22.406.17SINGLE0.900RAYON T322LEDB-300-UNI12-40-T3 MOUNT ON 25FT POLE WITH 3FT BASE4CCSINGLE0.900RAYON T632LED WALL MOUNT AT APPROX 10FT10.1410549DDSINGLE0.900ATLANTIC COM4-SYL20-35K-4CM10-HZ RECESSED AT APPROX 10FT17.11660299.236079Plan ViewScale: 1 inch= 40 Ft.GMSTSTSTSTSTHST11812925.39MHST12163924.90CBE12166925.22CBEAAAAAABBBBCCCCCCCCBBBBDDDDDDDDDDDDDDDDDDAAAA0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.4 0.5 0.5 0.4 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.5 0.6 0.6 0.6 0.4 0.3 0.3 0.2 0.2 0.3 0.4 0.5 0.6 0.7 0.6 0.5 0.4 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.5 0.6 0.8 0.9 0.9 0.7 0.6 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.5 0.7 1.0 1.3 1.3 1.1 0.7 0.5 0.3 0.3 0.3 0.4 0.6 0.9 1.2 1.4 1.3 0.9 0.7 0.5 0.4 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.2 0.3 0.3 0.3 0.3 0.3 0.4 0.4 0.4 0.5 0.7 1.0 1.5 1.8 1.7 1.4 0.9 0.6 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.4 0.5 0.7 1.2 2.1 2.9 3.0 2.1 1.2 0.8 0.6 0.5 0.5 0.6 0.9 1.6 2.5 3.2 2.7 1.8 1.1 0.8 0.7 0.6 0.5 0.4 0.5 0.5 0.5 0.4 0.4 0.3 0.3 0.4 0.4 0.4 0.4 0.4 0.6 0.6 0.7 0.7 0.8 1.0 1.7 2.8 3.7 3.6 2.6 1.5 0.9 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.00.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.4 0.5 0.9 1.6 2.6 3.9 6.3 6.4 4.1 2.8 1.7 1.0 0.7 0.8 1.2 2.0 3.1 5.1 6.9 5.8 3.6 2.5 1.6 1.1 0.9 0.8 0.8 0.8 0.9 0.8 0.7 0.6 0.5 0.5 0.5 0.6 0.7 0.8 0.8 1.0 1.1 1.1 1.1 1.3 1.8 3.0 5.3 7.9 7.5 4.9 2.7 1.7 1.2 0.8 0.6 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.00.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.4 0.6 0.8 1.4 2.6 4.7 7.6 10.5 10.6 8.0 5.0 2.7 1.4 0.9 1.0 1.7 3.2 5.7 8.8 11.1 9.9 7.0 4.3 2.4 1.6 1.3 1.4 1.5 1.6 1.8 1.6 1.2 0.9 0.7 0.7 0.8 1.1 1.4 1.5 1.6 1.8 1.7 1.5 1.6 1.8 2.6 4.3 7.5 10.9 10.6 7.0 4.0 2.4 1.7 1.3 1.0 0.8 0.5 0.3 0.3 0.2 0.1 0.1 0.1 0.00.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.4 0.5 0.8 1.1 1.5 2.0 3.1 4.8 7.3 10.0 10.2 7.7 5.1 3.2 1.9 1.4 1.5 2.3 3.6 5.7 8.5 10.7 9.6 6.9 4.6 3.1 2.2 2.0 2.3 3.0 3.6 3.8 3.1 2.0 1.3 0.9 0.9 1.2 1.8 2.6 3.3 3.5 3.2 2.5 2.1 2.0 2.2 2.9 4.6 7.6 10.7 10.6 7.2 4.3 2.7 2.1 1.9 1.7 1.3 0.9 0.6 0.4 0.2 0.2 0.1 0.1 0.10.0 0.0 0.1 0.1 0.1 0.2 0.3 0.5 0.7 1.1 1.5 1.8 2.1 2.5 3.4 4.4 6.2 7.6 7.8 6.4 4.5 3.3 2.1 1.6 1.6 2.5 3.5 4.9 6.9 8.2 7.6 5.9 4.5 3.5 2.6 2.6 3.4 5.2 7.4 8.4 5.6 3.0 1.7 1.1 1.1 1.6 2.8 4.8 7.1 6.9 5.3 3.6 2.7 2.3 2.3 2.7 3.9 6.0 7.7 7.5 5.7 3.7 2.7 2.4 2.5 2.7 2.3 1.8 1.2 0.7 0.3 0.2 0.2 0.1 0.10.0 0.1 0.1 0.1 0.2 0.3 0.4 0.7 1.4 2.1 2.7 3.0 2.8 2.7 3.0 3.5 4.3 4.8 4.9 4.3 3.4 2.5 1.8 1.5 1.5 2.0 2.7 3.7 4.5 5.0 4.9 4.3 3.5 2.9 2.7 3.0 4.3 7.0 10.4 11.3 8.2 4.0 1.8 1.2 1.2 1.9 3.7 7.8 11.0 10.2 7.3 4.6 3.1 2.4 2.2 2.4 3.0 4.0 4.7 4.7 3.9 3.0 2.6 2.8 3.2 3.8 3.7 3.3 2.2 0.9 0.6 0.4 0.2 0.2 0.10.0 0.1 0.1 0.2 0.2 0.4 0.7 1.0 2.6 4.1 4.4 4.1 3.4 2.8 2.5 2.6 2.7 2.8 2.7 2.6 2.3 1.7 1.2 1.0 1.1 1.4 1.9 2.4 2.7 2.8 2.9 2.8 2.5 2.2 2.3 2.9 4.4 7.1 10.3 10.6 7.5 4.2 2.1 1.3 1.2 1.8 3.7 7.6 10.8 10.8 7.7 4.8 3.2 2.3 2.0 2.1 2.4 2.7 3.1 2.9 2.6 2.4 2.4 3.0 3.9 5.0 5.7 5.8 3.6 1.6 0.9 0.5 0.3 0.2 0.10.1 0.1 0.1 0.2 0.3 0.5 1.0 1.9 3.9 6.9 6.7 5.6 4.1 2.9 2.1 1.7 1.6 1.4 1.3 1.4 1.3 1.0 0.8 0.6 0.7 0.9 1.2 1.4 1.5 1.4 1.6 1.6 1.6 1.7 1.9 2.4 3.5 5.4 7.1 7.3 5.5 3.5 2.1 1.4 1.3 1.8 3.2 5.6 7.6 7.9 6.1 4.0 2.7 2.0 1.7 2.0 2.2 2.3 2.3 2.0 1.8 1.8 2.0 3.0 4.5 6.7 8.3 8.8 5.5 2.7 1.3 0.7 0.4 0.2 0.10.1 0.1 0.1 0.2 0.4 0.7 1.3 2.9 6.3 9.9 9.3 7.3 4.9 0.4 0.7 0.7 0.7 0.6 0.8 0.8 0.7 0.7 0.6 0.4 0.5 0.7 0.7 0.8 0.8 0.9 1.0 1.0 1.1 1.2 1.4 1.9 2.6 3.5 4.3 4.4 3.5 2.6 1.8 1.4 1.3 1.6 2.4 3.6 4.6 4.8 3.9 3.0 2.1 1.5 1.4 1.7 2.9 2.7 1.6 1.3 1.3 1.2 1.5 2.8 4.7 7.7 10.3 11.2 7.9 3.6 1.6 0.7 0.4 0.2 0.10.1 0.1 0.1 0.2 0.4 0.7 1.5 3.4 7.6 11.3 10.5 8.0 5.31.1 1.3 1.8 2.3 2.6 2.6 2.3 1.8 1.4 1.2 1.1 1.3 1.7 2.3 2.7 2.8 2.5 2.1 1.5 1.21.1 1.6 2.7 4.5 7.1 9.3 10.0 6.7 3.1 1.4 0.7 0.4 0.2 0.10.1 0.1 0.1 0.2 0.4 0.6 1.3 2.7 5.3 8.8 8.4 7.0 5.21.2 1.5 1.7 1.7 1.5 1.4 1.1 1.0 0.9 1.0 1.2 1.5 1.7 1.8 1.7 1.51.1 1.8 2.6 3.8 5.5 6.6 7.0 4.2 2.0 1.0 0.6 0.3 0.2 0.10.1 0.1 0.1 0.2 0.3 0.5 0.9 1.6 3.4 5.8 5.7 5.3 4.61.0 1.1 1.1 1.0 1.0 1.4 2.0 1.9 1.0 0.9 1.1 1.1 1.2 1.2 0.91.8 1.7 2.2 2.9 3.9 4.3 4.2 2.7 1.1 0.7 0.4 0.2 0.2 0.10.1 0.1 0.1 0.2 0.3 0.4 0.6 0.9 2.1 3.3 3.7 3.9 3.90.7 0.7 0.7 0.8 7.8 17.3 14.5 2.5 0.7 0.8 0.8 0.82.3 1.4 1.5 2.0 2.7 2.6 2.2 1.5 0.7 0.4 0.3 0.2 0.1 0.10.1 0.1 0.1 0.2 0.2 0.3 0.4 0.7 1.3 1.8 2.4 2.8 2.60.1 0.4 0.5 0.6 8.3 18.9 15.9 2.6 0.6 0.6 0.6 0.60.8 1.0 1.0 1.3 1.5 1.4 1.0 0.7 0.5 0.2 0.2 0.1 0.1 0.10.1 0.1 0.1 0.2 0.2 0.3 0.4 0.6 0.8 1.1 1.4 1.6 1.70.3 0.3 0.5 8.0 18.3 15.5 2.5 0.4 0.40.3 0.4 0.5 0.7 0.8 0.7 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.00.1 0.1 0.1 0.2 0.2 0.3 0.4 0.5 0.7 0.8 1.1 1.2 1.20.7 0.7 0.70.7 0.7 0.70.5 0.5 0.4 0.4 0.3 0.2 0.20.0 0.00.1 0.2 0.3 0.3 0.4 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.00.1 0.1 0.2 0.2 0.3 0.4 0.5 0.6 0.8 1.0 1.2 1.2 1.3 1.2 1.0 0.9 0.8 0.8 0.9 1.0 1.0 1.0 1.0 1.0 0.9 0.7 0.5 0.4 0.3 0.2 0.2 0.20.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.00.1 0.1 0.2 0.3 0.4 0.5 0.7 0.9 1.2 1.5 1.8 2.0 1.9 1.7 1.5 1.3 1.1 1.1 1.3 1.5 1.7 1.8 1.8 1.6 1.3 1.0 0.7 0.5 0.4 0.3 0.2 0.20.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.00.1 0.1 0.2 0.3 0.5 0.7 0.9 1.2 1.7 2.3 2.8 3.1 2.9 2.5 2.0 1.7 1.5 1.6 1.8 2.2 2.6 3.0 2.9 2.5 2.0 1.4 1.0 0.7 0.5 0.4 0.40.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.1 0.1 0.2 0.3 0.5 0.8 1.1 1.6 2.3 3.4 4.6 5.2 4.6 3.5 2.5 2.0 1.9 1.9 2.2 3.0 4.1 4.9 4.9 3.9 2.7 1.8 1.2 0.8 0.6 0.5 0.7 0.90.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.1 0.1 0.2 0.3 0.5 0.7 1.2 1.8 2.9 4.7 7.3 8.5 7.3 4.8 3.1 2.2 1.9 2.1 2.6 3.8 6.0 7.9 8.0 6.0 3.6 2.2 1.3 0.9 0.6 0.5 0.7 1.4 2.20.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.1 0.1 0.1 0.2 0.4 0.7 1.1 1.9 3.2 5.7 9.4 11.6 9.2 5.7 3.3 2.2 1.9 2.0 2.7 4.4 7.4 10.9 10.9 7.4 4.2 2.3 1.3 0.8 0.5 0.4 0.4 0.7 0.8 0.20.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.1 0.1 0.2 0.3 0.6 1.0 1.7 2.9 5.3 8.8 11.2 8.9 5.2 2.9 1.9 1.6 1.8 2.5 4.0 6.8 10.4 10.7 7.1 3.9 2.0 1.2 0.7 0.4 0.3 0.3 0.4 0.4 0.2 0.10.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.1 0.1 0.2 0.3 0.5 0.7 1.2 1.9 3.3 5.8 7.1 5.8 3.3 2.0 1.4 1.2 1.3 1.7 2.6 4.6 6.8 7.0 4.7 2.5 1.4 0.9 0.5 0.3 0.2 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.1 0.1 0.1 0.2 0.3 0.4 0.6 1.0 1.8 2.7 3.3 2.9 1.9 1.1 0.8 0.8 0.8 0.9 1.4 2.4 3.2 3.3 2.4 1.5 0.8 0.5 0.4 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.1 0.1 0.1 0.2 0.2 0.4 0.7 1.0 1.4 1.6 1.5 1.1 0.8 0.5 0.4 0.5 0.6 0.9 1.3 1.6 1.6 1.3 0.9 0.6 0.3 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.1 0.1 0.1 0.2 0.3 0.4 0.6 0.7 0.8 0.8 0.6 0.5 0.4 0.3 0.3 0.4 0.5 0.7 0.8 0.8 0.7 0.5 0.4 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.2 0.3 0.3 0.3 0.4 0.4 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.01 fc1 fc0.5 fc0.5 fc0.25 fc0.25 fcTYPE AA & BBTYPE CCTYPE DD79 MEMORANDUM Tel: 612.879.6000 1301 American Blvd E. Suite 100, Bloomington, MN 55425 www.kaaswilson.com Page 1 of 1 Date: December 18, 2020 Attention: City of St Anthony Village Re: Development 65 Senior Housing Proposal Development 65 is proposing a 135-unit full service senior living building on a 4.35 acre site along the eastern edge of Stinson Parkway, a part of the historic Horace Cleveland Grand Rounds, between Lowry Avenue and 27th Avenue in St Anthony Village, Minnesota. Of these 135 senior units, 24 will be memory care, 28 will be assisted living, and 83 independent living. Once the proposed building is complete, Great Lakes Management will become the service provider for the community. Both Development 65 and Great Lakes Management have a proven track record in both responsibly developing and operating senior living communities throughout the MSP metro area. The proposed building layout would stretch north south along Stinson Parkway, with a jog eastward at the intersection with 26th Avenue. Main site access would align with this existing intersection as well, allowing vehicular traffic to easily flow into the established urban framework. Additionally, along a shared easement on the eastern edge of the site, an access road will be constructed to further aid site access for the potential of future developments. Between the access road and the proposed building will be a dense landscape buffer, allowing future residence to have access to peaceful outdoor spaces. The proposed senior living building is 4 stories with an underground parking garage, and will include amenities such as a large club room, multiple dining space, a commercial kitchen, separate memory care dining and lounge space, a memory care garden, and outdoor patio. The primary building materials will include brick, shake siding, and cement fiberboard siding. The brick and siding tones are reflective to what is found on the nearby St Charles Borromeo church and school, assuring the proposed building is complimentary to the existing neighborhood. The building must be large in order to provide needed resident services. However, consistent with Horace Cleveland’s ideas of “buildings in a park”, the façade is broken down into a series of “buildings” that project from the flat primary massing. Lastly, aluminum balconies and light accent trim shall also be featured in the design. The total parking for the development shall include approximately 91 garage stalls and 51 surface stalls, creating a 1.05:1 stall to unit ratio. Per city code, only 1 parking space is required for every 3 retirement home living units, therefore our current plan far exceeds the city requirements. We believe this parking count is more than sufficient to serve all residents, guests, and the building staff needed for the operation of this community. However, 20 proof of parking stalls have been designed into the site plan if the current parking amount is not adequate. Due to this site’s location along the Grand Rounds trail network, special considerations were put into the landscaping design of the site. Boulevard trees are proposed to be planted along Stinson Parkway to maintain its parkway appearance. Additionally, the stretch of drive that runs north of the main entrance parking would be grass paved, limiting the hardscaping visible to the public. Enhanced landscaping would be consistent throughout the site as well. Upon completion of the financing and various other development milestones, the goal for the project would be to break ground in the summer of 2021. The 14-16 month long construction timeline leads to a projected opening in the Fall of 2022. 80 PLANNING COMMISSION JANUARY 19, 2021 2501 Lowry Avenue NE Development 65 –Preliminary Plan PUD PRELIMINARY PLAN PUD -ZONING 81 PRELIMINARY PLAN PUD –SURROUNDING PARCELS, ETC. PRELIMINARY PLAN PUD –MAIN LEVEL PLAN 82 PRELIMINARY PLAN PUD –WEST ELEVATION CONCEPT PRELIMINARY PLAN PUD –FRONT ENTRY PERSPECTIVE 83 PRELIMINARY PLAN PUD –ELEVATIONS PRELIMINARY PLAN PUD –GARAGE LEVEL PLAN 84 PRELIMINARY PLAN PUD –UPPER LEVEL FLOOR PLAN PRELIMINARY PLAN PUD –LANDSCAPE CONCEPT 85 PRELIMINARY PLAN PUD –PUD CONSIDERATIONS Building height (code is 35 feet/3 stories); applicant proposes approximately 46 feet and 4 stories. Lot coverage/impervious surface (R-4 code limits this to 50%); applicant’s proposal is approximately 50.5%. Density (R-4 code limits this to approximately 24 units per acre, Comprehensive Plan calls for 20-40 units per acre); applicant is proposing approximately 32-36 units per acre. PRELIMINARY PLAN PUD –RECOMMENDED STAFF CONDITIONS 1. An access easement shall be in place to accommodate the easterly shared access road with the Urban Grove development site to Kenzie Terrace. Proof of such access easement shall be provided to the City as a part of the final PUD documentation. 2.Access-related issues shall be subject to comment and recommendation by the City Engineer. 3.The City finds that the proposed parking supply is adequate to serve the facility. 4.Final PUD Plans demonstrate compliance with ADA parking supply requirements (for disabled persons). 5.City Officials find the proposed four-story apartment building heights to be acceptable (within the context of the PUD). 6.As a part of the Final Plan submission, the submitted landscape plan be amended to add evergreen plantings along the north edge of the shared driveway. 7.As part of the Final PUD Plan submission, a signage plan be submitted for review which demonstrates compliance with City requirements. 8.Issues related to grading, drainage and utilities shall be subject to comment and recommendation by the City Engineer. 9.The applicant enter into a PUD agreement with the City and post all the necessary securities required by it. 10.Consideration of comments of other City Staff. 86 PRELIMINARY PLAN PUD –PLANNING COMMISSION ACTION Consideration of recommending approval for a Preliminary Plan PUD St. Anthony Village Senior Housing as presented by Development 65, and with conditions, including those recommended by staff and Planning Commission. PRELIMINARY PLAN PUD -PROCESS Preliminary Review with Community Development Committee (staff) Sketch Plan Review by Joint City Council and Planning Commission Preliminary Plan PUD Application – Public Hearing at Planning Commission; Consideration by City Council Financial Assistance Review and Consideration –HRA/City Council Final Plan PUD –City Council 87 THIS PAGE LEFT INTENTIONALLY BLANK 88 CITY OF SAINT ANTHONY VILLAGE HENNEPIN COUNTY, MINNESOTA RESOLUTION NO. _____________ A RESOLUTION APPROVING A REQUEST FOR A PRELIMINARY PLAN STAGE PUD, FOR THE SAINT ANTHONY VILLAGE SENIOR HOUSING PROJECT, A MULTI-FAMILY RESIDENTIAL PROJECT OF UP TO 155 DWELLING UNITS AT 2501 LOWRY AVENUE NE WHEREAS, the City of St. Anthony Village received a request from Development 65 LLC for a the St. Anthony Village Senior Housing PUD, redeveloping the subject site from single family residential to a multiple family residential development of up to 155 dwelling units at 2501 Lowry Avenue NE, legally described as follows: See Exhibit A; and WHEREAS, the property consists of approximately 4.25 acres and is located along the east boundary of Stinson Parkway and west boundary of the Urban Grove manufactured home park; and WHEREAS, the property is currently vacant; and WHEREAS, the property is currently zoned R-1, Single Family Residential; and WHEREAS, the project would be consistent with the St. Anthony 2040 Comprehensive Plan related to the conversion of this property from single family residential to multiple family residential use; and WHEREAS, the density of the proposed project at 32-36 units per acre is consistent with the Comprehensive Plan density range for such use; and WHEREAS, the Planning Commission has considered all of the comments and the staff report, which are incorporated by reference into the resolution; and WHEREAS, the Planning Commission held a public hearing on January 19, 2021 on the application and the applicant and members of the public were provided the opportunity to present information to the Planning Commission; and WHEREAS, the Planning Commission recommended approval of the Preliminary Plan PUD with the conditions noted in the Staff report, and as identified below; and WHEREAS, the City Council makes the following findings of fact in support of the resolution for approval: 1. The property is located in an area of mixed commercial and residential use. 2. The proposed improvements to the property are consistent with the character of the neighborhood in which it is located. 89 3. The various aspects of the proposed development are consistent with requirements of the City’s high density housing requirements, or are supported by the goals and objectives of the requirements for PUD consideration, and the long-term expectations of the Comprehensive Plan. 4. With the modification to the site plan under conditions as recommended by the Planning Commission, the proposed improvements constitute a reasonable use of the property. 5. The proposed PUD will accommodate reasonable use without negative impacts on neighboring property nor on public improvements and services. NOW THEREFORE MAY IT BE RESOVLED, that the City Council of the City of St. Anthony Village accepts the findings and recommendations documented in the staff report and approves Preliminary Plan for the St. Anthony Village Senior Housing PUD as shown on the plans submitted on December 17, 2020, at 2501 Lowry Avenue NE: 1. An access easement shall be in place to accommodate the easterly shared access road with the Urban Grove development site to Kenzie Terrace. Proof of such access easement shall be provided to the City as a part of the final PUD documentation. 2. Access-related issues shall be subject to comment and recommendation by the City Engineer. 3. The City finds that the proposed parking supply is adequate to serve the facility. 4. Final PUD Plans demonstrate compliance with ADA parking supply requirements (for disabled persons). 5. City Officials find the proposed four-story apartment building heights to be acceptable (within the context of the PUD). 6. As a part of the Final Plan submission, the submitted landscape plan be amended to add evergreen plantings along the north edge of the shared driveway. 7. As part of the Final PUD Plan submission, a signage plan be submitted for review which demonstrates compliance with City requirements. 8. Issues related to grading, drainage and utilities shall be subject to comment and recommendation by the City Engineer. 9. The applicant enter into a PUD agreement with the City and post all the necessary securities required by it. Passed in regular session of the City Council on the 9th day of February 2021. ____________________________________ Randy Stille, Mayor 90 ATTEST:____________________________ Nicole Miller, City Clerk Review for Administration: ____________________________________ Charlie Yunker, Interim City Manager 91 THIS PAGE LEFT INTENTIONALLY BLANK 92 Name Address Address NOTICE OF A PUBLIC HEARING January 19, 2021, 7:00 p.m. City Hall, 3301 Silver Lake Road, St. Anthony, MN 55418 Notice is hereby given that the City of Saint Anthony Village Planning Commission will hold a public hearing to consider the application of Development 65 for a Preliminary Plan stage PUD consisting of a 135-unit full service senior living building on a 4.35 acre site along the eastern edge of Stinson Parkway, between Lowry Avenue and 27th Avenue in St Anthony Village. The address of the subject property is 2501 Lowry Avenue a component of PID 07-029-23-23-0001. The Planning Commission agenda and packet item relating to this application will be made available prior to the meeting online at www.savmn.com. Ways to Comment: Online Those persons having an interest are encouraged to attend via Zoom. The link to participate via Zoom can be found at http://www.savmn.com/Calendar.aspx?EID=1220 In Person The public is welcome to attend in person at the City of Saint Anthony Community Center, 3301 Silver Lake Road, in the Council Chambers at 7:00 p.m. Please note seating is limited due to the pandemic. Written Written comments may be taken at the St. Anthony Village City Hall, 3301 Silver Lake Road, St. Anthony Village, Minnesota 55418 until the date of the public hearing. Comments can also be conveyed via email, to planner@savmn.com until the date of the public hearing. Questions? Questions may be directed to the City Planner at 763-957-1100. The Planning Commission will make a recommendation regarding the proposed request to the City Council for their meeting to be held on February 9, 2021 at 7:00 p.m. at City Hall. Steve Grittman City Planner 93 THIS PAGE LEFT INTENTIONALLY BLANK 94 MEMORANDUM To: St. Anthony Village Planning Commission From: Stephen Grittman, City Planner Date: City Council Regular Meeting for January 19, 2021 NAC File No: 323.01 – 20.21 Request: Request for a Conditional Use Permit for a Car Wash facility for Boulevard Autoworks at 2701 Kenzie Terrace. REFERRAL FROM COUNCIL FOR PLANNING COMMISSION RECOMMENDATIONS The applicant is proposing to construct a new car wash facility at 2701 Kenzie Terrace. The facility requires a conditional use permit, and would replace the existing parking lot on the site. Based on a review of the application, Planning Staff recommended approval of the CUP request, with conditions related to compliance with code requirements applicable to the impacts of the proposed use. The Planning Commission reviewed the application at a public hearing on December 15, 2020. Several members of the public provided written and oral comments, expressing concerns related to noise, lights, odors, and general compatibility with the neighborhood, with the potential to disrupt quality of life and diminish property values. The applicant expressed an interest in mitigating those concerns, and agreed to the required conditions recommended by staff. After the hearing, Commission discussed the item extensively, ultimately passing a motion to recommend approval of the Conditional Use Permit, based on the findings in the proposed resolution and with the conditions recommended in the staff report, as well as one additional condition limiting hours of operation to 7:00a.m. to 10:00p.m. The applicant had indicated that his proposed hours of operation would be 8:00a.m. to 5:00p.m. With those conditions, the Planning Commission vote was 7 in favor, 0 against. Subsequent to the Planning Commission meeting, a significant amount of additional public comment has been submitted through both written and verbal forums. One of those contributions has raised a concern related to the Planning Commission motion. The Commission took up the staff recommendation as a motion, then acted to incorporate an additional condition suggested by the Commission. A vote was taken, but the observer suggests that the vote only incorporated the additional condition into the Commission’s motion, and a subsequent vote on the motion as amended was not taken. While it appears that the intent of the Commission was clear, the City Council asked the Planning Commission to clarify its formal action, and has referred the item back to the Commission. At this meeting, therefore, staff is seeking a vote on the formal motion – as amended – which incorporates the original 10 staff conditions, and the hours of operation condition added by the Commission at its meeting on December 15. 95 January 12, 2021 Page 2 To do this under the applicable rules of meeting procedure, a member of the Commission should move the amended motion to bring it back to the table. Because the amendment language was approved by the Commission, this motion would not need a second. Because the public hearing was closed, the application is technically not up for additional public discussion. Staff has included copies of the correspondence that has been provided since the hearing for background. With this motion, the item will be on the table, with a recommendation of approval of the Conditional Use Permit, including the now 11 conditions. Those conditions are listed below. 1. Revise the plan to shift the facility and westerly egress lane at least 5 feet to the east (see next note). 2. In this additional setback space, plant a continuous row of Spruce trees no greater than 15 feet on center, to create and grow a buffer between the access aisle and the adjoining multi-family residential building. Due to the proposed grade and retaining wall, a wider space (and thus, greater shift) may be necessary to accommodate this planting. 3. Add larger evergreen trees to the northwest corner of the site to moderate impacts of headlights in the stacking lane. 4. Reorient the parking/access lanes in the front area to 90 degree parking angles, and eliminate the one-way circulation patterns that add unnecessary pavement. 5. Add a solid fence line along the north boundary/alley to create a buffer between the commercial activity and the single family neighborhood to the north, and add landscaping in that space to enhance the visual aesthetic and reinforce the buffer. 6. Add larger evergreen stock in the northeast portion of the stacking lane area to screen headlights from the single family properties. 7. Add a permanent canopy cover and solid side-walls to the vacuum area to buffer noise from this area and direct any noise to the south towards Kenzie Terrace, to mitigate noise impacts on the adjoining multi-family building. As noted above, there is no provision for outdoor commercial uses in the zoning ordinance, and a permanent canopy would avoid this conflict. 8. Reduce parking lot light pole height to no more than 20 feet, and ensure full cut-off hooded fixtures to reduce light spillage onto adjoining property. 9. Specify hooded, downcast wall lighting on the building to avoid any light-source glare. 10. Compliance with the requirements of the City Engineer with regard to a and construction, including utilities, stormwater, and street improvements. 11. Hours of Operation limited to between 7:00a.m. and 10:00p.m. The chair can then open discussion from the Commission, until the Commission is ready for a vote. A majority vote in favor will send the item to the City Council with a recommendation of approval as amended. The staff report, Commission discussion, and (draft) Council resolution will stand as the findings of fact supporting this motion. A majority vote in opposition will send the item to the City Council with a recommendation for denial. In this case, those voting against the motion should state their reasons for the record, which would then stand as the findings supporting the denial recommendation. A Copy of the original staff report is included in the Planning Commission’s packet materials for background. 96 MEMORANDUM To: St. Anthony Village Planning Commission From: Stephen Grittman, City Planner Date: Planning Commission Regular Meeting for December 15, 2020 NAC File No: 323.01 – 20.21 Request: Request for a Conditional Use Permit for a Car Wash facility for Boulevard Autoworks at 2701 Kenzie Terrace. BACKGROUND AND STAFF RECOMMENDATION The applicant is proposing to construct a new car wash facility at 2701 Kenzie Terrace. The facility requires a conditional use permit, and would replace the existing parking lot on the site. Based on a review of the proposed, Planning Staff recommends approval of the CUP request, with conditions related to compliance with code requirements applicable to. GENERAL INFORMATION Applicant: Boulevard Autoworks Owner: Boulevard Autoworks Location: 2801 Kenzie Terrace Existing Land Use / Zoning: Vacant / Zoned: C, Commercial Surrounding Land North: Single Family / Zoned: R-1 – Single Family Residential Use / Zoning: East: Commercial / Zoned: C – Commercial South: Commercial / Zoned: C – Commercial West: Multi Family Residential/ Zoned: PUD – Planned Unit Development Deadline for Agency Complete Application Date: 11-17-20 Action: 60 Days: 1-16-20 Letter Sent: Yes 120 Days: 3-17-20 97 December 15, 2020 Page 2 ANALYSIS 1. Background The applicant proposes to construct a car wash facility with a series of outdoor vacuum stations on the subject property, a current vacant parcel along Kenzie Terrace, just west of their current automobile service business. The subject property has been used as overflow parking, with limited pavement, but no buildings or other formal principal use. The proposed car wash building would be located toward the north/middle portion of the property, utilizing the middle of three existing curb cuts to Kenzie Terrace. The other two curb cut access points would be closed. Traffic is designed to enter the site and circulate counter-clockwise around the building to the entrance at the west end, exiting the building to the east, with access to a series of one-way driveways that provide access to outdoor vacuum stations on the south side of the building. The site plan also provides 6 additional parking stalls on the site in two separate bays. Automobile Service and Car Washes are both listed as Conditional Uses in the C, Commercial zoning district. (Sections 152.122 D. and F.). The zoning ordinance provides a series of setback requirements as follows: Front Yard (from street right of way): 35 feet Side Yard: 10 feet Rear Yard: 25 feet to an alley The zoning ordinance imposes an additional setback requirement in Commercial zoning districts adjacent to Residential zoning districts, which provides: Setbacks from residential districts. There 98 December 15, 2020 Page 3 must be a setback area of not less than 20 feet from any property in a residential district within which setback area parking, storage, and/or loading facilities are excluded. The proposed site plan appears to meet these minimum standards. In addition to the minimums, however, a Conditional Use Permit is subject to the following requirements to qualify for City approval, a specific in Section 152.243(C): (1) The use is one of the conditional uses specifically listed for the district in which the property is located; (2) The City Council has specified all conditions which the City Council deems necessary to make the use compatible with other uses in the area; (3) The use will not be detrimental to the health, safety, or general welfare of persons residing or working in the vicinity or to the values of property in the vicinity; and (4) The use will provide a service or a facility which is in the interest of public convenience and will contribute to the general welfare. As such, the standard of review is heightened by measuring how a particular use will impact both the public and the neighboring land uses. In addition to these review criteria, it must be noted that in Minnesota, courts have ruled that Conditional Uses are presumed to be allowed in the zoning district in which they are proposed, but that there are special aspects of the use that require attention and perhaps, mitigation, to ensure that they are consistent with the requirements and intent of the City’s zoning regulations and Comprehensive Plan. That is, there is a presumption that the use is allowed on properly zoned land – the question is whether the impacts of the use can or cannot be mitigated to a reasonable level expected of other permitted uses in the district. Therefore, the review of this use must consider how a typically permitted commercial use would impact the area, and if there are special aspects of this use that require alteration or other attention. For the Commercial zoning district, common commercial uses include retail and office facilities, as well as most commercial service businesses, although many services are also required to obtain Conditional Use Permits. Outdoor commercial uses are not listed as permitted uses in the district. For a car wash, there are some extraordinary aspects that require particular attention, over and above the common commercial use impacts. The most notable are headlight glare from vehicles sitting in stacking lanes, and noise from two sources – the exit dryer location, and the proposed exterior vacuum stations shown on the site plan. To mitigate these issues, staff has proposed some specific additions and changes to the site plan designed to moderate these impacts. As noted above, it is not reasonable to require the elimination of all impacts of commercial activity on the property. However, these recommended changes are intended to address those additional impacts of the proposed use. 1. Revise the plan to shift the facility and westerly egress lane at least 5 feet to the east (see next note). 2. In this additional setback space, plant a continuous row of Spruce trees no greater than 15 feet on center, to create and grow a buffer between the access aisle and the adjoining multi-family residential building. Due to the proposed grade and retaining wall, a wider space (and thus, greater shift) may be necessary to accommodate this planting. 3. Add larger evergreen trees to the northwest corner of the site to moderate impacts of headlights in the stacking lane. 4. Reorient the parking/access lanes in the front area to 90 degree parking angles, and eliminate the one-way circulation patterns that add unnecessary pavement. 99 December 15, 2020 Page 4 5. Add a solid fence line along the north boundary/alley to create a buffer between the commercial activity and the single family neighborhood to the north, and add landscaping in that space to enhance the visual aesthetic and reinforce the buffer. 6. Add larger evergreen stock in the northeast portion of the stacking lane area to screen headlights from the single family properties. 7. Add a permanent canopy cover and solid side-walls to the vacuum area to buffer noise from this area and direct any noise to the south towards Kenzie Terrace, to mitigate noise impacts on the adjoining multi-family building. As noted above, there is no provision for outdoor commercial uses in the zoning ordinance, and a permanent canopy would avoid this conflict. 8. Reduce parking lot light pole height to no more than 20 feet, and ensure full cut-off hooded fixtures to reduce light spillage onto adjoining property. 9. Specify hooded, downcast wall lighting on the building to avoid any light-source glare. 10. Compliance with the requirements of the City Engineer with regard to engineering and construction, including utilities, stormwater, and street improvements. These recommendations are illustrated, in part, as follows: Without these additions to the proposal, staff could not recommend approval of the proposed Conditional Use Permit. However, if these changes are made, staff believes that the use would meet the expectations for the impacts of commercial land uses, minimizing those as necessary to be reasonably compatible with the surrounding area. 2. Applicable Code Sections. Title XV Land Usage, Chapter 152 Zoning Code, Section §152.243 establishes the process and findings required for consideration of Conditional Use Permits. 100 December 15, 2020 Page 5 Title XV Land Usage, Chapter 152 Zoning Code, Section §152.122 identifies the allowable Conditional Uses in a C, Commercial zoning district. Title XV Land Usage, Chapter 152 Zoning Code, Section §152.124 and 125 identify the performance standards application to uses in the C, Commercial zoning district. CONCLUSION Staff recommends approval of the requested Conditional Use Permit for a car wash facility at 2701 Kenzie Terrace, only with the following conditions: 1. Revise the plan to shift the facility and westerly egress lane at least 5 feet to the east (see next note). 2. In this additional setback space, plant a continuous row of Spruce trees no greater than 15 feet on center, to create and grow a buffer between the access aisle and the adjoining multi-family residential building. Due to the proposed grade and retaining wall, a wider space (and thus, greater shift) may be necessary to accommodate this planting. 3. Add larger evergreen trees to the northwest corner of the site to moderate impacts of headlights in the stacking lane. 4. Reorient the parking/access lanes in the front area to 90 degree parking angles, and eliminate the one-way circulation patterns that add unnecessary pavement. 5. Add a solid fence line along the north boundary/alley to create a buffer between the commercial activity and the single family neighborhood to the north, and add landscaping in that space to enhance the visual aesthetic and reinforce the buffer. 6. Add larger evergreen stock in the northeast portion of the stacking lane area to screen headlights from the single family properties. 7. Add a permanent canopy cover and solid side-walls to the vacuum area to buffer noise from this area and direct any noise to the south towards Kenzie Terrace, to mitigate noise impacts on the adjoining multi-family building. As noted above, there is no provision for outdoor commercial uses in the zoning ordinance, and a permanent canopy would avoid this conflict. 8. Reduce parking lot light pole height to no more than 20 feet, and ensure full cut-off hooded fixtures to reduce light spillage onto adjoining property. 9. Specify hooded, downcast wall lighting on the building to avoid any light-source glare. 10. Compliance with the requirements of the City Engineer with regard to engineering and construction, including utilities, stormwater, and street improvements. ALTERNATIVE PLANNING COMMISSION ACTION 1. Motion to recommend approval of the request for CUP at 2701 Kenzie Terrace with the conditions identified in this report, recommending the attached resolution declaring terms and findings for City Council consideration. 2. Motion to recommend denial of the CUP. In the event of a recommendation for denial, the Planning Commission must state its findings related for denial on the record. 3. Request Additional Information and Table Action. A motion to table should be accompanied by the specific information requested of staff or the developer necessary to make a recommendation. 101 December 15, 2020 Page 6 ATTACHMENTS Exhibit A: Application and Supporting Material Exhibit B: Draft resolution 102 103 104 105 ALLEYKENZIE TERR ACE COOLIDGE STREET NE WILSON ST NE(COUNTY ROAD NO . 1 5 3 )C-0.0BLVD AUTOWORKS CARWASH COVER PAGE 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTIONKnow what's below.Call before you dig.Dial 811BLVD AUTOWORKS CARWASH SAINT ANTHONY, MN 2701 KENZIE TERRACESHEET INDEX C-0.0C-1.0SITEEXISTING CONDITIONS SURVEYC-3.0SITE PLANC-5.0UTILITY PLANC-6.0DETAILSL-1.0LANDSCAPE PLANC-4.0GRADING PLANCLARK WICKLUND, PEALLIANT ENGINEERING INC.233 PARK AVENUE SOUTH SUITE 300MINNEAPOLIS, MN 55415Phone 612-758-3080/Fax 612-758-3099cwicklund@alliant-inc.comPETER GOERS, PLSALLIANT ENGINEERING INC.233 PARK AVENUE SOUTH SUITE 300MINNEAPOLIS, MN 55415Phone 612-758-3080/Fax 612-758-3099dolmstead@alliant-inc.comMARK KRONBECK, PLA, ASLAALLIANT ENGINEERING INC.233 PARK AVENUE SOUTH SUITE 300MINNEAPOLIS, MN 55415Phone 612-758-3080/Fax 612-758-3099mkronbeck@alliant-inc.comVICINITY MAPNOT TO SCALECIVIL ENGINEER LAND SURVEYOR LANDSCAPE ARCHITECT PHOTOMETRIC PLANJOHN GROTKINRJ RYAN CONSTRUCTION, INC.1100 MENDOTA HEIGHTS ROADMENDOTA HEIGHTS, MN 55120Phone 651-365-7003//Fax 651-681-0235john.grotkin@rjryan.comGENERAL CONTRACTOR COVER SHEETA1ARCHITECTURAL SITE PLANA2FLOOR PLAN AND ELEVATIONSA3COLOR BUILDING ELEVATIONSCONTACT: JAMES BERTHIAUMELAMPERT ARCHTITECTS420 SUMMIT AVEST. PAUL, MN 55102Phone 763-755-3=1211/Fax 763-757-2849james@lampert-arch.comARCHITECT C-2.0DEMOLITION PLAN CITY PLANNING SUBMITTAL P-1.0AND DETAILS 106 N89°18'31"E 372.25S39°13'14"E 231.88S 5 0 ° 4 6 ' 4 6 "W 2 9 1 . 2 1 ALLEYKENZ IE TERRACE COOLIDGE STREET NE WILSON ST NE (COUN T Y RO AD NO . 1 5 3 )C-1.0BLVD AUTOWORKS CARWASH EXISTING CONDITIONS 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTIONLEGAL DESCRIPTIONThat part of the South Half of the Northwest 1/4 of Section 7, Township 29, Range 23 described as follows:Commencing at the intersection of the North line of the South 1079 8/10ths feet of the Northwest 1/4 with theNorthwesterly line of the original Northwesterly line of County Road No. 33, thence Southwestely 300 feet along saidNorthwesterly line, thence Northwesterly at right angles to the North line of the South 1079 8/10ths feet of theNorthwest 1/4, thence east to the point of beginning, except the road.NOTES1. This survey was prepared without the benefit of a title commitment and may not depict all easements,appurtenances, and encumbrances affecting the property.2. The locations of existing utilities on or serving the property are depicted based on Gopher State One Call Ticket No.202314033, available city maps, records and observed evidence locations. Lacking excavation, underground utilitylocations may not be exact. Verify critical utilities prior to construction or design.3. The orientation of this bearing system is based on the Hennepin County Coordinate System NAD83 1986Adjustment.4. All distances are in feet.5. The area of the above described property is 33,763 square feet or 0.775 acres.6. Bench Mark: City of Minneapolis Control Station GPS009, a MPLS Disk located south of the parking area alongRidgeway Parkway in the cemetery, approximately 4600 feet southeast of subject property, has an elevation of 956.96feet NGVD 29.7. Site Bench Mark: Sanitary manhole rim at the intersection of Wilson Street NE and Alley near the northwest cornerof site has an elevation of 916.90 feet NGVD 29Know what's below.Call before you dig.Dial 811107 ALLEYKENZ IE TERRACE COOLIDGE STREET NE WILSON ST NE (COUN T Y RO AD NO . 1 5 3 )C-2.0BLVD AUTOWORKS CARWASH DEMOLITION PLAN 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTIONKnow what's below.Call before you dig.Dial 811108 ALLEYKENZ IE TERRACE COOLIDGE STREET NE WILSON ST NE (COUN T Y RO AD NO . 1 5 3 )C-3.0BLVD AUTOWORKS CARWASH SITE PLAN 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTIONSITE PLAN NOTES: GENERAL NOTES: LEGEND: SITE DATA: Know what's below.Call before you dig.Dial 811109 ALLEYKENZ IE TERRACE COOLIDGE STREET NE WILSON ST NE (COUN T Y RO AD NO . 1 5 3 )C-4.0BLVD AUTOWORKS CARWASH GRADING PLAN 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTIONKnow what's below.Call before you dig.Dial 811110 C-5.0BLVD AUTOWORKS CARWASH UTILITY PLAN 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTIONUTILITY NOTES: UTILITY LEGEND: STORM SEWER SCHEDULE: RAIN GUARDIAN TURRET NOT TO SCALE1OCS 3NOT TO SCALE3Know what's below.Call before you dig.Dial 811FILTRATION BASINNOT TO SCALE2111 13 1/2"R3 " R3"1/2" PER FT.R12"R12"HANDICAPPEDPARKINGVEHICLE IDREQUIREDTYPTYPCLCLTYPTYPTYP TYP (VERIFY WITH SITE PLANS)FINISHED GRADE(SURFACE VARIES)PAVED SURFACE(PAVEMENT TYPEVARIES)COMPACTEDAGGREGATE BASESIZE NO. 53 AT 95%PROCTOR DENSITYCOMPACTEDSUBGRADECONCRETE CURB& GUTTER36"6" ROUND STEEL PIPEBOLLARD CONCRETE FILLEDEXPANSION JOINTBITUMINOUS PAVEMENT48" 8"20" DIA. FOOTINGC-6.0BLVD AUTOWORKS CARWASH DETAIL SHEET 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTIONKnow what's below.Call before you dig.Dial 811112 ALLEYKENZ IE TERRACE COOLIDGE STREET NE WILSON ST NE (COUN T Y ROAD NO . 1 5 3 )L-1.0BLVD AUTOWORKS CARWASH LANDSCAPE PLAN 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTIONLANDSCAPE LEGENDLANDSCAPE SCHEDULE: PLANTING NOTES: ZONING CODE: PERENNIAL PLANTINGNOT TO SCALE3EQUAL SPACINGPERENNIALS (TYP.),PLANT IN STAGGEREDROWS UNLESSOTHERWISE SHOWN ONLANDSCAPE PLANMIN. 3"-4" DEPTHHARDWOOD MULCH OVERFILTER FABRIC, SEE NOTESFOR TYPE & COLOR.MIN. 12" PLANTING SOIL ASSPECIFIED, SEE NOTES.UNDISTURBED ANDUNCOMPACTEDSUBGRADE2SHRUB PLANTINGNOT TO SCALEPROVIDE MULCH, DO NOT BURY STEMS ORTRUNK. SEE NOTES FOR TYPE AND DEPTHREQUIRED.UNDISTURBED ANDUNCOMPACTED SUBGRADEPRUNE DEAD AND BROKEN BRANCHESROOT BALL SHOULD SITDIRECTLY ON TOP OFUNDISTURBED SOIL.BACKFILL WITH TOPSOILFROM HOLE AND WATERTHOROUGHLY. PROVIDEPLANTING SOIL ASSPECIFIED IN NOTES.PROVIDE FILTER FABRIC,MIRAFI OR EQUALPLANT TOP OF ROOT BALL 1-2" ABOVESURROUNDING GRADE.PREPARE PLANTING AREA 3XTHE DIAMETER OF THEROOTBALL1TREE PLANTINGNOT TO SCALENOTES:1. TREE STAKING IS OPTIONAL.2. DO NOT PRUNE THE TREE AT PLANTING. PRUNE ONLY CROSSOVER LIMBS, CO-DOMINANT LEADERS ANDBROKEN OR DEAD BRANCHES.3. FOR TREES IN CONTAINERS, REMOVE CONTAINER PRIOR TO PLANTING. FOR BARE ROOT TREES, PLACETREE IN MIDDLE OF PLANTING HOLE, SPREAD ROOTS OUT RADIALLY FROM THE TRUNK AROUND THEPREPARED HOLE.PREPARE PLANTING AREA 3X THEDIAMETER OF THE ROOTBALL OR PERPLAN IF PLANTED IN A BIORETENTIONOR LARGER PLANTING AREAPLACE ROOTBALL ON UNEXCAVATED OR TAMPED SOILEXPOSE TRUNK FLAREMULCH RING, DIAMETER PER PLAN ORLANDSCAPE NOTES. PLACE MULCH SO NOT INCONTACT WITH BASE OF TREE.COMPLETELY REMOVE AND DISPOSE OF ALLTWINE, ROPE AND BASKETS. DISPOSE INTOPROPER LOCATION.TAMP SOIL AROUND ROOTBALL BASE FIRMLY WITH FOOTPRESSURE SO THAT THE ROOT BALL DOES NOT SHIFT.PLANTING SOIL, BACKFILL PLACED IN 6" LIFTSGUYING PLANSODUNDISTURBED SUBSOILROOTBALLPRUNE DEAD AND BROKEN BRANCHES16" POLY STRAP, 40 MIL. 1-1/2" WIDE1 FLAG PER WIRE3-GUY CABLES, DOUBLE STRAND, 14 GA. WIRESAT 120° SPACING, SEE GUYING PLAN18" MIN.MACHINE EDGE V-DITCH AROUNDALL TREES IN SODDED AREAS2"X2"X24" WOODEN STAKE AT AN ANGLEKnow what's below.Call before you dig.Dial 811113 ALLEYKENZ IE TERRACE COOLIDGE STREET NE WILSON ST NE (COUN T Y RO AD NO . 1 5 3 )0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.00.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.00.0 0.1 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.00.0 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.00.4 0.5 0.6 0.5 0.4 0.4 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.00.9 0.0 1.1 1.0 0.8 0.9 0.8 0.5 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.01.1 0.0 2.1 2.2 1.9 1.7 1.5 1.3 1.1 0.6 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.00.9 0.2 2.7 4.0 4.8 4.4 3.4 2.5 1.9 1.6 1.5 0.6 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.0 0.00.6 0.1 2.0 4.0 7.6 9.7 7.9 5.4 3.5 2.5 2.1 2.1 2.5 0.5 0.4 0.3 0.3 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.0 0.00.4 0.6 1.2 2.3 5.1 9.4 11.9 10.2 6.7 4.1 2.9 2.6 2.8 3.5 4.9 1.5 0.4 0.3 0.3 0.3 0.3 0.3 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.00.5 1.0 1.4 2.6 4.8 8.0 10.4 9.2 6.4 4.1 3.1 2.8 3.2 4.5 6.8 9.2 6.0 0.5 0.5 0.5 0.5 0.4 0.3 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.00.3 0.0 1.0 1.5 2.3 3.8 5.4 6.8 6.4 4.7 3.5 2.9 2.8 3.2 4.8 7.5 10.0 9.1 6.1 0.8 0.8 0.7 0.6 0.4 0.3 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.00.2 0.0 1.3 1.3 1.5 2.0 2.6 3.5 4.2 3.9 3.3 2.7 2.3 2.4 2.9 4.1 6.3 7.8 7.2 5.4 3.2 1.1 1.0 0.8 0.6 0.4 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.1 0.0 1.8 2.0 1.6 1.1 1.6 2.1 2.6 2.9 2.7 2.4 2.0 1.8 1.9 2.3 3.3 4.8 5.6 5.3 4.6 3.7 2.9 1.7 1.1 0.8 0.2 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.1 0.1 1.5 2.7 3.24.6 4.4 4.4 4.5 4.5 4.0 3.0 1.9 0.5 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.1 0.1 1.7 4.6 3.8 3.33.9 3.9 4.4 5.5 6.4 5.9 4.3 1.7 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 0.0 8.4 6.9 4.9 3.32.8 3.7 4.7 6.7 8.8 8.7 6.1 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.0 0.0 8.4 9.8 7.9 5.2 3.4 2.4 2.1 2.3 2.9 4.3 6.0 6.9 5.9 4.2 2.7 1.9 1.5 1.5 2.4 3.1 4.4 6.8 9.6 9.9 0.4 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.1 3.0 6.3 7.6 6.5 4.4 2.9 2.2 1.9 2.2 3.1 5.0 7.8 9.3 7.7 4.9 2.9 1.9 1.4 1.6 1.9 2.4 3.5 5.3 7.2 1.1 0.2 0.2 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.0 0.5 2.8 3.9 4.7 4.2 3.2 2.3 1.8 1.7 2.1 3.1 5.0 8.1 10.0 8.1 4.9 2.9 1.8 1.4 1.4 1.5 1.9 2.5 3.4 2.6 0.3 0.2 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.0 0.2 1.2 1.7 2.3 2.6 2.5 2.0 1.5 1.0 0.8 0.6 0.3 0.7 0.3 0.2 0.2 0.7 0.3 0.5 0.7 0.9 1.1 1.3 1.7 1.7 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.1 0.5 0.8 1.1 1.4 1.5 1.5 1.3 0.9 0.6 0.4 0.3 0.2 0.2 0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.8 1.0 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.0 0.2 0.4 0.6 0.8 0.9 1.0 1.0 0.8 0.6 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 0.3 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.1 0.2 0.3 0.4 0.5 0.6 0.6 0.6 0.5 0.4 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.2 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.1 0.1 0.2 0.3 0.4 0.4 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.1 0.1 0.1 0.2 0.3 0.3 0.3 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.0 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0AAHAAAAHAAHAABBBBP-1.0BLVD AUTOWORKS CARWASH PHOTOMETRIC PLAN 733 Marquette AvenueMinneapolis, MN 55402612.758.3080www.alliant-inc.comSuite 700FOR REVIEW ONLYPRELIMINARYNOT FOR CONSTRUCTION6130 Blue Circle Dr., Minnetonka, MN 55343Ph 952-217-0400 - Fax 952-930-1632www.pulseproducts.comLuminaire ScheduleSymbolQtyLabelArrangementTotal Lamp LumensLLFDescriptionLum. Watts1AASINGLE10.792RAYON T322LEDB-250-UNI12-40-T5 MOUNT ON 20FT POLE WITH 2FT BASE (LLF ADJUST FOR2504AAHSINGLEN.A.0.900RAYON T322LEDB-250-UNI12-30-T4-HS MOUNT ON 25FT POLE WITH 3FT BASE255.52BBSINGLEN.A.0.900RAYON T632LED WALL MOUNT AT APPROX 10FT10.14Calculation SummaryLabelCalcTypeUnitsAvgMaxMinAvg/MinMax/MinSITE GROUNDIlluminanceFc1.1311.90.0N.A.N.A.SOUTH PARKINGIlluminanceFc2.774.21.81.542.33Know what's below.Call before you dig.Dial 811114 115 116 117 From: JL Fleming <oxfordjet@gmail.com> Sent: Monday, December 7, 2020 4:56 PM To: planner@savmn.com Cc: Yvonne M <yvonnemeyer@hotmail.com>; Steve Dehler <stevedehler@gmail.com>; bbrozak <ebbrozak@comcast.net>; ljeremiason@outlook.com; David Eichinger <esw@usa.com> Subject: Request to Postpone Agenda Item - December 15 Planning Commission Meeting To Mr. Grittman, City Planner: I am sending this individually as an affected homeowner at the property adjacent to the subject parcel mentioned in the undated notice from the City of St Anthony regarding the "public" hearing (by Zoom) regarding 2701 Kenzie Terrace use, currently on the agenda for Tuesday, December 15 at 7:00pm: Request: Please postpone the December 15 meeting agenda item regarding the parcel at 2701 Kenzie Terrace to instead be conducted in good faith at a later time, e.g., spring or summer of 2021, when there is no health crisis and the limited participation solely by Zoom won't stifle the ability for many members of the public to provide feedback to the meeting – esp. several directly affected homeowners on property adjacent to subject parcel. See rationale for request for postponement: • I believe fewer than half of the 25-30 homes at the Kenzington Condominiums most-affected by the subject of the proposed permit use even have the technology or ability to participate in Zoom meetings. Thus, it isn't really good-faith or equitable public access to a meeting to limit participation on this important item to only those who have access to Zoom. • While there is a different and separate hearing coming up - a December 8 public hearing (tomorrow) - I note that meeting is regarding a development that, once it's built, won't have actual and known constant disturbance of the quality of life for the specific owners of the 25-30 units instantly affected here at the Kenzington by the proposed project at 2701 Kenzie Terrace - not asking for postponement of the December 8 Zoom meeting. The specifically affected homeowners at The Kenzington need to be able to have fair and full access to the meeting that is the subject of the current December 15 notification. • This item is presumably an item on a monthly meeting agenda, but it is for a meeting just 10 days before Christmas, during a pandemic, and there is undue stress on all Minnesotans and the populace in general, this seems like a rush job to fluff over the subject matter of this mailed notice - doesn't feel fair. This item could be postponed per above rationale and the rest of the meeting agenda go forward. • The applicant for this item's conditional use permit should understand that postponement of this item would be a sign of good faith dealing with residents in the community, and is not requested with an adversarial intention at all. When it's safe to conduct Planning Commission meetings in person for the public at City Hall, then let's have this meeting. Thank you. Respectfully submitted by: Jeanette Fleming, Owner, #410, The Kenzington (working from home since March, full capability for web meetings, myself, but know that is not the case for many of my neighbors who, along with myself, overlook the subject parcel) 612-801-1882 oxfordjet@gmail.com 118 From:Lee John Kurtz To:SA City; SA City Subject:Please forward this e-mail to the Mayor and City Council of Date:Saturday, December 05, 2020 3:37:41 PM Caution: This email originated outside our organization; please use caution. Hello, my name is Lee John Kurtz, and I reside at 2601 Kenzie Ter apt 109, the Kenzington Condominiums in St Anthony. I was deeply disturbed yesterday by a letter I received about a possible car wash being constructed at 2701 Kenzie Ter sometime in the future. My unit is one of the unlucky 25 that overlooks the property. I have talked to 3-4 of my neighbors and we are vehemently AGAINST this project! I'm sure NO ONE in their right mind would want a noisy car wash operating so close to their home. The fact that I work from 4:15 PM until 2:30 AM makes this even WORSE for me as I generally sleep from 4 AM until 11 or 11:30 AM during the work week. I see there is a ZOOM meeting scheduled about this in a week or so, but my work schedule and my non experience with Zoom ANYTHING, makes it a no go for me. I just want you all to know that, if necessary, I will rally the residents to at LEAST sign a petition against the possible car wash being built AND a boycott of Blvd Auto. A couple of the neighbors that I have talked to are 10 or more years OLDER than me (I am 60) and would enjoy the hell out of re- living their activities of the 1960's and fighting for a cause/protesting for the greater good (greater good being the residents of our building, and the 7 or 8 houses along 27 Ave NE that would also be affected by this project.) I'm sure there are available industrial use type properties somewhere in the area where a car wash can operate WITHOUT disturbing the lives of property tax paying citizens. Also, IF this car wash were to be allowed to operate on this property, I am SURE that our property values ( along with our property tax amounts) would take a tremendous turn downward. In my case, for example, I purchased my unit in 2017 with the full intention of selling it in June of 2025, to help finance my relocation to my native northern MN after my retirement. There as as many financial plans for the people living here as the number of people living here. Originally, I thought about sending an e-mail to Tom (?), the owner of Blvd Auto, to log my complaint, but reconsidered and decided to leave it to the people whose sworn oath is to protect the citizens of this city. I am neither a Democrat, or a Republican. I generally vote for the person who I think will do best at the job. Some of you I voted for, and others I did not. What I HAVE seen during the almost 4 years of living here, is that St Anthony is WAY better ran than Minneapolis, where I lived the majority of the 40 years since I relocated from Duluth in 1980. This is a simple quality of life issue. A car wash will SEVERELY deter the quality of life for quite a few people if built here. I can only speak for myself when I say that the farther along the plans for this proceed, the bigger the effort to stop it will be. I am BEGGING you to nip this in the bud BEFORE we have to spend the time and effort to fight this. I am ALL IN for this cause and consider myself to NOT be a "cause guy" at all normally. Thank you for your time. I can be reached at this e-mail address or 612-789-7172 between the hours of 11 AM and 2 PM Mon-Thurs, or anytime after noon on Fridays. I assume you take weekends off, but would be willing to discuss this with anyone from city hall ANYTIME on the weekends. Thanks once again!! LJK 119 Hello, I am writing to notify you of my concerns with the recently proposed carwash between Blvd Auto and The Kenzington. My house backs up to the proposed carwash site and I have many concerns with the proposal. The planning work so far has many gaps. Frankly I am concerned with the competence of the planning and zoning committee given these many gaps! I have the following concerns: 1. Placement in a residential neighborhood 2. Alley traffic and parking 3. Lighting 4. Pollution (Noise and Car Pollution) 5. Water management 1. Although the lot is zoned commercial, it is quite small and triangular. The lot butts up to residential housing on 2 of 3 sides. There will be a significant amount of traffic that will negatively effect property values. We already deal with significant traffic due to the Kenzington. The proposed site has a dumpster that faces the alley, which will result in more traffic. 2. Due to the street layouts in the area, increased alley traffic is very likely. This is an alley of single family homes where children frequently play and bike. Parking along our street is already significant at times. Just this week cars were displaced from the Kenzington parking lot due to a construction dumpster and a large crane! Currently Blvd employees park in the empty lot. Where will Blvd and Car Wash employees park once that lot is no longer available? There are not sufficient parking places indicated in the current plan, accounting for the Blvd staff parking. 3. Kenzington already has extremely bright lighting along the alley that is disruptive to the use of our home. We have had to install blackout shades in rooms facing the alley because of the parking lot lights in order to sleep in them! The addition of the car wash parking lot lights would add to the already present lighting problem, and further decrease the usability of all of our yards and south facing rooms. 4. I am VERY concerned about the poor air quality that will result in area yards due to the large volume of cars idling extremely close to my house. Car exhaust has been shown to increase the incidence of developmental delays such as autism. Has a study been done on the likely levels? Other area car washes have significant lines with idling cars for hours at a time. This will be located 20 feet from fenced yards where children play outside year round! Additionally, there will likely be significant noise pollution from the car wash and vacuum motors. I have not seen a study indicating how many decibels the motors will 120 produce. How could this have been approved by the Planning and Zoning Commission without analyzing this data? The volume of cars expected for a car wash is significant- as many as 600 cars on a Saturday or Sunday, 20 feet from residents’ yards! Would you enjoy having a car wash firing up in your back yard at 8 am on a Saturday or Sunday, nonstop, all day long? We certainly would not like that, and I expect it will significantly reduce our property value. I doubt any of you would appreciate that in your yard. 5. Has a full study done on water use and water management? There are already major water drainage issues in that lot and along the alley during summer rains. Currently the lot is permeable, and we already have this issue. How will this be managed? I have not seen this in the plans. It seems possible that water will be directed into residents’ yards. I do not believe the city has done their due diligence on any of these issues. I believe the Mayor and City Council should investigate how this was passed by the Planning and Zoning Commission with so many gaps. Regardless of the outcome of this matter, I encourage an investigation into the competence of the Commission prior to their being presenting with further proposals. Given the lack of due diligence by the Planning Commission to fully analyze the project in the interests of protecting the public and the current residents, I request that the Mayor and City Council reject the permit application. The Council must find that the use is not detrimental to health, safety, and general welfare of persons residing or working in the vicinity or to the values of property in the vicinity. None of this work has been done. This is a critical oversight. We believe the proposed use of the property is detrimental on all fronts. Best Regards, Suzan Cox 2616 27th Ave NE 121 1 Charlie Yunker From:noreply@civicplus.com Sent:Friday, January 08, 2021 6:16 PM To:Charlie Yunker Subject:Online Form Submittal: Public Comments for City Council Meetings Caution: This email originated outside our organization; please use caution. Public Comments for City Council Meetings First Name Cary and Gary Last Name Zahrbock Phone Number 612-270-0636 Email Address czahrbock@gmail.com Address 2704 27th Ave NE City St. Anthony State Minnesota Zip Code 55418 Public Comment January 8, 2021 Dear City Council members and City planner, We have been pleased to be St Anthony residents since 1984, and have owned our house on 27th Ave NE since July of 1987. We are writing to express our concerns about the planning commission’s approval of a Conditional Use Permit (CUP) for the proposed BLVD Carwash at 2701 Kenzie Terrace. In order for a Conditional Use Permit (CUP) to be given, the existing laws regarding impact of the project must be satisfied, specifically, in order for the CUP to be approved, The Council must find that the use is not detrimental to health, safety, and general welfare of persons residing or working in the vicinity or to the values of property in the vicinity. As owners of a single family home adjacent to the lot under consideration, we have the following concerns that have not been addressed and resolved by the St Anthony planning commission: 122 2 1. Location next to residential property 2. Health/safety/general welfare a. Air Pollution b. Noise Pollution c. Safety concerns 3. Water capacity and runoff management 4. Property values 1. LOCATION: The proposed carwash is in the middle of a residential area. Our single family homes, zoned R-1 would be adjacent to a carwash. Our neighbors to the South, the Kensington, is a multi-family housing building. My sister, Jan Cavanaugh, is an owner in the Kensington and shares our concerns about the impact of a car wash built at this location. There is no precedent in St. Anthony for a carwash adjacent to an R-1. It is a poor choice for the use of the land considering the housing nearby. 2. HEALTH/SAFETY/GENERAL WELFARE A. Air Pollution. No environmental impact study was done by St. Anthony Planning staff regarding the air pollution resulting from idling cars. The plans submitted show a maximum capacity of 16 cars in staging---all presumably idling. Imagine having 16 cars idling outside your backyard for many hours a day while in your back yard. There is no evidence presented by the planning commission that assessed this impact. When neighbors and I spoke with Tom, from Blvd, his business projections are an average of 100-120 cars per day. As someone who regularly uses a car wash, there are many rainy or snowy days that would be eliminated, leaving the bulk of the car washes occurring on nice days, when we would like to be outside of our home. B. Noise Pollution. The plan and planning commission assessment does not include an analysis of decibel levels during operating hours of the car wash. a. Specific noise concerns from our perspective are cars idling, car radios (imagine the cacophony of multiple car radios playing different radio stations, including at least one with a very loud bass thumping), multiple vacuums in use, and the noise of the engine noise, buzzers, brushes, water spray and dryers from the carwash itself. There is lack of analysis, or demonstration that the proposal is compliant with existing city and state noise ordinances. We believe that it is the planning staff’s duty is to ensure that these noise elements have been studied and submitted and are compliant. b. Hours of operation are of concern, as the initial response of the planning commission was to expand the requested hours of 123 3 the car wash from 7 am to 10 pm, 7 days per week. This neighborhood is quiet, so that currently, we can have conversations with neighbors outside, enjoy the sounds of birds and can sleep past 7 am on the weekends. Imagine living next to the noise identified above, 7 days per week, 15 hours per day. This is obviously detrimental to the health and general welfare of residents. C. Safety concerns. During a cordial and thoughtful discussion with Tom, from Blvd, we discussed the proposed fencing that would be bordering the north side of the proposed car wash. His plan (in accordance with the planning commission’s recommendation) would be to build a wooden fence at least 6 feet high the length of the alley. While this could provide some relief from car wash noise and visually, the planning commission did not provide an analysis regarding the impact on neighborhood safety. We have concerns about the potential risks to safety and property damage when the fence reduces sightlines to potential criminal behavior. 3. Water capacity and runoff management: There are millions and millions of dollars in upcoming proposed housing projects that will all need water. When the Lowry-Grove project was analyzed concerns were identified relative to insufficient infrastructure to accommodate the water needs of that project as well as the impact of water runoff by reduction of permeable surfaces. The projects on this end of the city, Kenzie Terrace and Stinson Parkway development, Development 65, and Trident Redevelopment Bremer site are under consideration for approval. We are concerned about potential impact on R-1 water volume and adequate volume for fire suppression. In addition, by changing the current permeable surface of the vacant lot to non-permeable surfaces, we are concerned that the sewer infrastructure may be inadequate to manage the volume of water used by the carwash as well as the change to non-permeable surface. The planning commission has not addressed or resolved this concern. 4. Property values: As required per ordinance for a CUP request, the City Must demonstrate there is no adverse devaluation of the R-1 occupancies. Until all the proper analysis of these key factors has been done (Health/Safety/General Welfare), there is no way to make an assessment of what will happen to property values. Given the impacts identified above - air pollution, noise pollution, safety concerns and water capacity, it is hard to imagine that the value of our property will not be negatively impacted. This will not only impact the homes along the 27th Ave alley, but also houses even a block or two away. Certainly, the value of the 124 4 Kenzington condos overlooking the carwash will be negatively impacted. From our perspective this proposed use will force depreciation of property values. That is unacceptable to the existing residents nearby who are paying considerable taxes to be a part of this lovely area. The Council must find that the use is not detrimental to health, safety, and general welfare of persons residing or working in the vicinity or to the values of property in the vicinity. None of this work has been done. This is a critical oversight. We believe the proposed use of the property is detrimental on all fronts. In consideration of the lack of due diligence by the Planning Commission to analyze and protect the public by examining data required by law, we believe that the Council must reject the conditional use permit. Additionally we are asking that this letter be put into the public record. Respectfully Submitted, Cary Zahrbock Gary Zahrbock 2704 27th Ave NE St. Anthony, MN 55418 Email not displaying correctly? View it in your browser. 125 1 Charlie Yunker From:Barbara Gottfried <bgott3joy@gmail.com> Sent:Sunday, January 10, 2021 10:45 AM To:Jan Jenson; Wendy Webster; Tom Randle; Bernard Walker; Charlie Yunker; *SAPlanner; Randy Stille; Thomas Kuykendall Subject:Kenzie Blvd Car Wash CUP Caution: This email originated outside our organization; please use caution. Please sign this in to the City Council Meeting for January 12, 2020: Dear Mayor and City Council, I live at the Kenzington Condos, a 55 + building, with my husband. Our home is facing and very near to the proposed car wash, as are 24 other condo units. I'm a cancer survivor of 6 years and I have asthma. My health is not as robust as a young person's. I'm sure that other seniors in our building of 150 units can say the same about their health. We are a vulnerable population. The idling car fumes from many cars, much of the day, everyday, is my biggest concern. This will negatively impact our air quality. Most of every day, I won't be able to open any of my windows nor use my balcony because of my health. I'm asking you to please oppose the construction of this car wash for the health of the seniors in the Kenzington condos. (Many retired seniors are at home much of the day.) Thank you, Barbara Gottfried Unit #307 126 This letter is to notify the St. Anthony City Council and Planning Commission of the many critical omissions in the proposal for the BLVD Carwash that is going to the council for approval based on the recommendations of the Planning Commission guided by the City Planner. In order for a Conditional Use Permit (CUP) to be given, the existing laws regarding impact of the project must be satisfied. There is much that has not been done. The proposal carwash is in the middle of housing. To the immediate south is the Kensington, a large condominium complex; to the east and south across the street is Autumn Woods, a large apartment complex; to the north and west, single family homes, some of which would be in the neighborhood of 30 feet away from the proposed carwash. The housing is R-1 zoned. There is no precedent in St. Anthony for a carwash adjacent to an R-1. It is a poor choice for the use of the land considering the housing nearby. The Council must find that the use is not detrimental to health, safety, and general welfare of persons residing or working in the vicinity or to the values of property in the vicinity. None of this work has been done. This is a critical oversight. We believe the proposed use of the property is detrimental on all fronts. HEALTH/SAFETY/GENERAL WELFARE Car Pollution. No environmental impact study was done by St. Anthony Planning staff. The plans submitted show a maximum capacity of 16 cars in staging---all presumably idling. Once these 16 spaces are used, where will the other waiting cars be? I can only assume they will be on Kenzie Terrace—a county road? People using a carwash may choose to leave their cars idling when using the vacuums. What is the projected emissions and it’s impact on the health of the people in the homes and condos and apartments? How many cars per hour are projected at peak use? I,Tom Deegan, spoke to two staff persons at the nearest carwash similar to the proposed BLVD Carwash---Mr. Carwash at 44th and Central Ave. in Columbia Heights. They told me,Tom Deegan, that at peak the number of cars per day is between 600 -800 cars (hours 7:30am-7pm). What is expected volume of cars projected? What are the proposed hours for the carwash? It is something to note that Mr. Carwash is quite loud and is nowhere near an R-1 zone. Light Pollution. The current lighting at BLVD Auto, right next to the proposed carwash, is exceedingly bright and, we believe, already there is a negative impact to existing housing. We believe that the existing lighting needs remediation and is possibly not within the ordinance. Now with the added light expected at the carwash, there would seem to be an issue of further light pollution. There needs to be an elevation submitted that demonstrates the projection of the lights proposed do not impact the adjacent R-1 dwellings. Noise Pollution. Where is the analysis of the decibel levels when the proposed carwash is working at full capacity? Specifically, cars idling, all vacuums being used, and the noise of the dryers from the carwash itself. We can only assume there will be car stereo noise. Are the 127 plans compliant with existing city noise ordinances? The planning staff’s duty is to ensure that these noise elements have been studied and submitted and are compliant. The neighborhood is quiet. This is one of the reasons people enjoy living in this area. We like to walk our dogs and visit with our neighbors. It is impossible to fully capture the negative impact of this project on the overall quality of life and desirability of being a homeowner, a condo owner, an apartment dweller in this neighborhood. WATER CONSUMPTION There are millions and millions of dollars in upcoming proposed housing projects that will all need water. At the time of the first iteration of the Lowry-Grove project there was concern that there may need to be added infrastructure to accommodate the water needs of that project. While that project went away, new projects are coming. The projects on this end of the city, Kenzie Terrace and Stinson Parkway development, Development 65, and Trident Redevelopment Bremer site are under consideration for approval. Where is the analysis of water usage for the BLVD Carwash and the expected needs of the area as there is further development been considered? How will this affect R-1 occupancies water volume? Will there be adequate volume for fire suppression? What is the big picture in terms of water needs to the community? We are a top tier Green City. There are systems for car wash facilities that are Green compliant. As there are few specifics throughout the proposal being brought forth by the Planning Commission, the Council cannot determine if this is a Green compliant project. In fact, it is possible to wash a car with less than 15 gallons of water then recapture and reuse almost 100% of that water. (See Denver, CO – Gleam carwash) All of the Health/Safety/General Welfare questions are about the impact of the proposed carwash on the health of the neighborhood’s residents. As a Green City it would seems we can do better to protect our citizenry by being diligent and following the law before bringing this submission to the Council. VISION FOR THE SOUTHERN GATEWAY TO ST. ANTHONY Is there a big picture vision for the southern gateway to the city? Does a carwash fit into that vision? PROPERTY VALUES As required per ordinance for a CUP request, the City Must demonstrate there is no adverse devaluation of the R-1 occupancies. Until all the proper analysis of these key factors has been 128 done (Health/Safety/General Welfare), there is no way to make an assessment of what will happen to property values. Will this carwash in such close proximity be detrimental to the value of the Kenzington condos which will overlook it? Will this carwash not affect the value the homes along the 27th Ave alley as well as across 27th Ave. most directly? Will it not affect the housing even a block or two away, especially in terms of air quality and noise as well as and property values? We believe it will. It seems very unlikely that these property values will Not suffer. From our perspective this proposed use will force depreciation of property values. That is unacceptable to the existing residents nearby who are paying considerable taxes to be a part of this lovely area. Finally, we can only wonder at the negligence of the Planning Commission and the City Planner. How can it be that such shoddy work has been even proposed? We are concerned and dismayed and would like the Mayor and the City Council to investigate what is going on and do the necessary work of oversight of the Planning Commission. We are concerned that a very careful choice is made for the permanent City Planner. In consideration of the lack of due diligence by the Planning Commission to analyze and protect the public by examining data required by law, we believe that the Council must reject the conditional use permit. Additionally we are asking that this letter be put into the public record. Respectfully Submitted, Thomas Deegan Susan Guthrie 2616 Pahl Ave. St. Anthony, MN 55418 129 1 Charlie Yunker From:Stephen Grittman <sgrittman@nacplanning.com> Sent:Monday, January 11, 2021 8:56 AM To:Charlie Yunker; Nicole Miller Subject:FW: subject ; Boulevard Car Wash. Caution: This email originated outside our organization; please use caution. FYI Stephen Grittman Northwest Associated Consultants, Inc. 4150 Olson Memorial Highway, Suite 320 Golden Valley, MN 55422 763-957-1100 (office) 651-726-7293 (direct) From: Walter Sentyrz <sentyrz@yahoo.com> Sent: Monday, January 11, 2021 8:53 AM To: planner@savmn.com Subject: subject ; Boulevard Car Wash. Mr. Steve Grittman City Planner of Saint Anthony Village. I am the owner of six homes in Saint Anthony Village, 2604 27th Ave N.E., 3100 Wilson St. N.E., 3401 Coolidge St. N.E., 3713 33rd Ave N.E., 2508 Saint Anthony Blvd., and my residence since 1985, 3316 Highcrest Road N.E. I am excited to endorse the Boulevard Car Wash project. I have known Mr. Thomas Archambault and his family for over 20 years. Tom has always been a caring and meticulous business owner. I believe Mr. Archambault will continue to run the car wash with the same pride and care as his present business. Also, the land use would transform a parking lot to a hard asset, paying Real Estate Taxes to Saint Anthony Village. Respectfully submitted, Walter B. Sentyrz Jr. 130 1 Charlie Yunker From:Barbara Gottfried <bgott3joy@gmail.com> Sent:Monday, January 11, 2021 5:09 PM To:Randy Stille; Tom Randle; Bernard Walker; Wendy Webster; Jan Jenson; Charlie Yunker; *SAPlanner Subject:CUP for Car Wash on Kenzie Terrace Caution: This email originated outside our organization; please use caution. Dear Mayor and City Council, Please add this to the public comments for the January 12th meeting at 7:00. I want to emphasize a question I wrote in my previous email to you. Can any of you, in truth, say you would welcome a car wash bordering your home and yard? We, as the many neighbors bordering the proposed car wash on both sides have submitted our list of negative impact statements and a petition. I'm a senior. Seniors are a vulnerable population! And, we seniors are a protected class under the law. Please keep in mind, the Kenzington Condos are not just a building to be counted as one neighbor. There are more than 150 people living here. Thank you, Barbara Gottfried Kenzington Condominiums 131 1 Charlie Yunker From:Thomas <thomas.isaacson@gmail.com> Sent:Monday, January 11, 2021 6:29 PM To:Charlie Yunker Subject:BLVD Car Wash Proposal Caution: This email originated outside our organization; please use caution. Hello Mayor, Council Members and City Staff, Regarding the proposed BLVD car wash on Kenzie Terrace: The northern boundary of the proposed plan, the side that abuttes the single family residential neighborhood, lacked considerable definition in comparison to the western boundary where The Kenzington is located. Elevation, vehicular access, garbage collection and details of the screening considerations for light, sound and visual aesthetics were not included in the proposal. Before the project is voted upon I think these details need to be established so that the neighborhood knows exactly what is being proposed. This development exacerbates what is a rather confusing area from a planning and safety perspective. 1. 2. The 27th Ave. alley that 3. runs next to the proposed development site is rumored to be a one-way intersection between Wilson and Kenzie Terrace and two-way between Wilson and Stinson (a stretch that runs uninterrupted for 1.5 blocks, which is unusual). The correct traffic designation 4. could not be confirmed by the city management upon request for clarification (again, unusual). 5. 6. 7. The exit of the alley on 8. Kenzie Terrace is a safety concern (confirmed with the police department) because you cannot make a legal left or right turn out of it, which may be why the traffic at this point of the alley is intended to be one-way (again, unconfirmed). 9. 10. 11. The intersection of the 12. 27th Ave. alley and Wilson is signed as a dead end when approaching from the north however traffic flows through the intersection. 13. 14. 15. There is visual obstruction 16. in the NE corner of the intersection which is a hazard for pedestrians, cyclists and drivers, all of whom regularly use this route. 17. I feel strongly that any development on this lot does not contribute further to traffic in the single family neighborhood immediately to the north. This triangle neighborhood is essentially an island surrounded by the major thoroughfares of St. Anthony Boulevard, Stinson and Kenzie Terrace that also experiences traffic from St Charles Church and School (not to mention NE cut through traffic along 27th Ave). 132 2 Finally, I feel like the peak operating times of the car wash are the exact opposite of what they should be for successfully coexisting with the neighborhood. During normal times, people are home during the weekend and that is when car washes are at peak times with constant operations. Any concerns around pollution (exhaust, noise and light) would be amplified during times when people are home. This goes against the conditional use permit approval condition of "not be detrimental to health, safety, general welfare of persons residing or working in the vicinity or to the values of property living in the vicinity." in my opinion. -Thomas Isaacson 2604 Pahl Ave 133 1 Charlie Yunker From:noreply@civicplus.com Sent:Tuesday, January 12, 2021 10:48 AM To:Charlie Yunker Subject:Online Form Submittal: Public Comments for City Council Meetings Caution: This email originated outside our organization; please use caution. Public Comments for City Council Meetings First Name JOHN Last Name KUFUS Phone Number 612-419-0722 Email Address john.kufus@gmail.com Address 2712 27TH AVE NE City ST. ANTHONY VILLAGE State MN Zip Code 55418 Public Comment January 11, 2021 Subject: Notice of Action on Proposed Car Wash 2701 Kenzie Terrace My name is John Kufus and I reside at 2712 27th Ave. NE. I am one of the property owners who will most directly be affected by the above proposal and I wish to strongly disagree with the Planning Commission’s decision to approve a conditional use permit to Boulevard Autoworks for the construction of a carwash at 2701 Kenzie Terrace. My concerns are principally: Noise due to dryer blower motors, vacuum cleaners, idling cars, car radios Traffic congestion along Kenzie Terrace Air Pollution due to idling cars 134 2 Decrease in property values due to the above concerns Sincerely, John A. Kufus 2712 27the Ave. NE St. Anthony Village, MN 55418 Email not displaying correctly? View it in your browser. 135 1 Charlie Yunker From:Randy Stille Sent:Monday, January 11, 2021 6:55 PM To:Charlie Yunker Subject:Fw: Online Form Submittal: Send Mayor Randy Stille an Email Randy Stille Mayor City of St. Anthony Village 3301 Silver Lake RD, St. Anthony, MN 55418 612-782-3301 | www.savmn.com randy.stille@savmn.com From: noreply@civicplus.com <noreply@civicplus.com> Sent: Thursday, January 7, 2021 8:03 PM To: Randy Stille Subject: Online Form Submittal: Send Mayor Randy Stille an Email Caution: This email originated outside our organization; please use caution. Send Mayor Randy Stille an Email First Name Suzan Last Name Cox Address 2616 27th Ave NE City St. Anthony State MN Zip Code 55418 Contact preference By email Phone Number 5154503368 Email Address Field not completed. Comments Hello, I am writing to notify you of my concerns with the recently proposed carwash between Blvd Auto and The Kenzington. My 136 2 house backs up to the proposed carwash site and I have many concerns with the proposal. The planning work so far has many gaps. Frankly I am concerned with the competence of the planning and zoning committee given these many gaps! I have the following concerns: 1. Placement in a residential neighborhood 2. Alley traffic and parking 3. Lighting 4. Pollution (Noise and Car Pollution) 5. Water management 1. Although the lot is zoned commercial, it is quite small and triangular. The lot butts up to residential housing on 2 of 3 sides. There will be a significant amount of traffic that will negatively effect property values. We already deal with significant traffic due to the Kenzington. The proposed site has a dumpster that faces the alley, which will result in more traffic. 2. Due to the street layouts in the area, increased alley traffic is very likely. This is an alley of single family homes where children frequently play and bike. Parking along our street is already significant at times. Just this week cars were displaced from the Kenzington parking lot due to a construction dumpster and a large crane! Currently Blvd employees park in the empty lot. Where will Blvd and Car Wash employees park once that lot is no longer available? There are not sufficient parking places indicated in the current plan, accounting for the Blvd staff parking. 3. Kenzington already has extremely bright lighting along the alley that is disruptive to the use of our home. We have had to install blackout shades in rooms facing the alley because of the parking lot lights in order to sleep in them! The addition of the car wash parking lot lights would add to the already present lighting problem, and further decrease the usability of all of our yards and south facing rooms. 4. I am VERY concerned about the poor air quality that will result in area yards due to the large volume of cars idling extremely close to my house. Car exhaust has been shown to increase the incidence of developmental delays such as autism. Has a study been done on the likely levels? Other area car washes have significant lines with idling cars for hours at a time. This will be located 20 feet from fenced yards where children play outside year round! Additionally, there will likely be significant noise pollution from 137 3 the car wash and vacuum motors. I have not seen a study indicating how many decibels the motors will produce. How could this have been approved by the Planning and Zoning Commission without analyzing this data? The volume of cars expected for a car wash is significant- as many as 600 cars on a Saturday or Sunday, 20 feet from residents’ yards! Would you enjoy having a car wash firing up in your back yard at 8 am on a Saturday or Sunday, nonstop, all day long? We certainly would not like that, and I expect it will significantly reduce our property value. I doubt any of you would appreciate that in your yard. 5. Has a full study done on water use and water management? There are already major water drainage issues in that lot and along the alley during summer rains. Currently the lot is permeable, and we already have this issue. How will this be managed? I have not seen this in the plans. It seems possible that water will be directed into residents’ yards. I do not believe the city has done their due diligence on any of these issues. I believe the Mayor and City Council should investigate how this was passed by the Planning and Zoning Commission with so many gaps. Regardless of the outcome of this matter, I encourage an investigation into the competence of the Commission prior to their being presenting with further proposals. Given the lack of due diligence by the Planning Commission to fully analyze the project in the interests of protecting the public and the current residents, I request that the Mayor and City Council reject the permit application. The Council must find that the use is not detrimental to health, safety, and general welfare of persons residing or working in the vicinity or to the values of property in the vicinity. None of this work has been done. This is a critical oversight. We believe the proposed use of the property is detrimental on all fronts. Best Regards, Suzan Cox 2616 27th Ave NE Email not displaying correctly? View it in your browser. 138 1 Charlie Yunker From:Randy Stille Sent:Monday, January 11, 2021 6:55 PM To:Charlie Yunker Subject:Fw: Online Form Submittal: Send Mayor Randy Stille an Email Randy Stille Mayor City of St. Anthony Village 3301 Silver Lake RD, St. Anthony, MN 55418 612-782-3301 | www.savmn.com randy.stille@savmn.com From: noreply@civicplus.com <noreply@civicplus.com> Sent: Thursday, January 7, 2021 4:06 PM To: Randy Stille Subject: Online Form Submittal: Send Mayor Randy Stille an Email Caution: This email originated outside our organization; please use caution. Send Mayor Randy Stille an Email First Name Sarah Last Name Cole Address 2420 27th ave NE City Saint Anthony State MN Zip Code 55418 Contact preference By phone Phone Number 2183907258 Email Address snwolff@hotmail.com Comments Hello, I am a resident of St. Anthony Village and live on 27th Ave NE between Stinson Blvd and Wilson. I am writing in regard to the 139 2 proposal of putting in a public car wash at the end of the alley between 27th Ave NE and Kenzie Terrace. I would like to state my strong desire for you to reconsider the location of this, and if that is not an option, at least consider what implications having this business in this location does to the surrounding residents. At the very least, I would expect to see some conversations around removing access to the alley for non- residents so they don't use it as a thoroughfare or cut through for easier access to the car wash. I would beg you to think of adding barricades to restrict access to the alley from Kenzie Terrace or Wilson at the fence line of the apartment building. I can only imagine the increased traffic and noise we would see, not to mention the deterioration of the already compromised alleyway. We use this alleyway for access to our garage while driving, and also use it when we are walking our dog or out with our children. As with all updates to the residential and commercial areas, I would hope and expect the city to have the safety of our citizens at the forefront of all decisions. Thank you for your time and consideration. Sincerely, Sarah Cole, and family 2420 27th Ave NE Email not displaying correctly? View it in your browser. 140 1 Charlie Yunker From:Randy Stille Sent:Monday, January 11, 2021 6:54 PM To:Charlie Yunker Subject:Fw: Online Form Submittal: Send Mayor Randy Stille an Email Randy Stille Mayor City of St. Anthony Village 3301 Silver Lake RD, St. Anthony, MN 55418 612-782-3301 | www.savmn.com randy.stille@savmn.com From: noreply@civicplus.com <noreply@civicplus.com> Sent: Friday, January 8, 2021 1:33 PM To: Randy Stille Subject: Online Form Submittal: Send Mayor Randy Stille an Email Caution: This email originated outside our organization; please use caution. Send Mayor Randy Stille an Email First Name Dan Last Name Spriggs Address 3331 Stinson Blvd City St Anthony State MN Zip Code 55418 Contact preference No follow up needed Phone Number 6122696118 Email Address michellejks@aol.com Comments Mr. Stillie There should be an ordinance that would bar the Confederate Flag from being displayed in any public venue in the city of St. 141 2 Anthony Max Spriggs, my father, fought at D-day. With an all African American unit, and risked his life for this country. When he returned from the war, he had to sit in the back of the bus and drink from separate water fountains. When the Confederate Flag was flown in the Nation Capital and how it has become a staple of the Ku Klux Klan rallies and how it has been it is waved to intimidate Black children who were integrating schools after Brown vs. the Board of Education. There should be no place for it in public places. The Confederate Flag represents the states that disfranchise Black Citizens. It is a flag that will be associated with the January 6 insurrection. The Rebel Flag had never been flown to my knowledge inside the halls of Congress. In the picture that shows the Confederate flag in the halls of Congress, there is a picture in the background of Summer, a representative from Mississippi who was beaten by Preston Brooks in May of 1856 on the floor of Congress for speaking out about slavery. So an Ordance should be introduced banning the Confederate flag from being displayed in public places. Thanks, Dan Spriggs Email not displaying correctly? View it in your browser. 142 1 Charlie Yunker From:Randy Stille Sent:Monday, January 11, 2021 6:53 PM To:Charlie Yunker Subject:Fw: Online Form Submittal: Send Mayor Randy Stille an Email Randy Stille Mayor City of St. Anthony Village 3301 Silver Lake RD, St. Anthony, MN 55418 612-782-3301 | www.savmn.com randy.stille@savmn.com From: noreply@civicplus.com <noreply@civicplus.com> Sent: Monday, January 11, 2021 5:32 AM To: Randy Stille Subject: Online Form Submittal: Send Mayor Randy Stille an Email Caution: This email originated outside our organization; please use caution. Send Mayor Randy Stille an Email First Name Jesse Last Name Pikturna Address 2616 27th Ave NE City Saint Anthony State Minnesota Zip Code 55418 Contact preference By email Phone Number 5154501572 Email Address pikturna@gmail.com Comments Mayor Stille, I am writing to notify you of my concerns with the recently proposed carwash between Blvd Auto and The Kenzington. 143 2 This site is just across the alley from my backyard. The proposed project will negatively impact me and my family. If approved it will be detrimental to our quality of life. I am shocked that such a project was recommended for approval by our Planning Commission. I would like to call on the city to deny this project based on the following concerns. All of these should have been raised by the Planning Commission. Their oversight is cause for broader concern as many larger projects are proposed in St. Anthony over the next several years. I have the following specific concerns with regard to the proposed car wash: Adjacency to a residential neighborhood Alley traffic and parking Noise pollution Air pollution Lighting Adjacency To A Residential Neighborhood The lot itself may not be zoned as residential, but the lot itself is very small. Residential housing neighbors it. If the project moves forward, neighboring single family homes will be impacted by activity at the site: traffic, noise, traffic, air emissions, and water pollution. Our quality of life will suffer. I believe my property value will suffer. I certainly would not have purchased my home had there been a car wash across the alley at the time. I am aware of no study that has been completed that demonstrates that property values cannot suffer as a result of such a project. As such, the concern is real and should have been addressed by the Planning Commission. There is a reason why new construction of car washes next to residential areas is rare, if it happens all. Alley Traffic and Parking The alley is already heavily used and this project might result in congestion in the alley. It could well result in our neighbors losing access to their garages if cars back up in the alley while waiting for washes. I understand too that there is potential for garbage trucks to access the alley to remove trash from a large dumpster on the site, a very different activity from unloading of small residential cans. Such activity could generate a lot of noise in the neighborhood. Additionally, I anticipate traffic and parking spilling onto Wilson and 27th Ave, creating crowding and potentially safety issues. 144 3 Noise Pollution I am aware of no study that has been done to quantify the level of noise that will be in our neighborhood after this project is complete. However, I have a swing set in my backyard. If children play on the swing set, I want them to be able to do so without damaging their hearing. I want my children to be able to sleep at night. I have no confidence that the carwash, if approved, will not result in disruption to my family. The Minnesota Pollution Control Agency has set thresholds for noise in residential areas. The project has not demonstrated that noise in our neighborhood will be below those thresholds upon completion. It has not demonstrated that noise will be below thresholds during construction. This work needs to be done before anything can be approved on this site. Air Pollution I have no idea what impact a number of idling cars will have on the air in the alley, but I want people to be able to walk down the alley and use their garages without suffering ill effects from fume inhalation. I want our neighbors at the Kenzington to be able to use their balconies without suffering ill effects from exhaust. I am aware of no study that has been done to study these impacts. Lighting I am very concerned about the light pollution that could be produced by this project. Bedroom windows in my house face the site. Children sleep in those rooms. Light pollution from the construction project and/or from the finished project could negatively impact my children. It could cause issues with their sleep. It could cause issues with their ability to learn in school. It could be detrimental to our quality of life. I do not believe the proposed project has done the necessary work to address any of these issues. In order to approve, the Council must find that the use is not detrimental to health, safety, and general welfare of persons residing or working in the vicinity or to the values of property in the vicinity. However, this project, if approved, will be detrimental to general welfare. There is also good reason to suspect that it could lower property values and cause ill effects on health. For those reasons, the council should reject the application. In addition, the council should review the qualifications of members of the Planning Commission members and offer training or take other steps to ensure competent work by the members. 145 4 Best Regards, Jesse Pikturna 2616 27th Ave NE Email not displaying correctly? View it in your browser. 146 1 Charlie Yunker From:Randy Stille Sent:Monday, January 11, 2021 6:34 PM To:Charlie Yunker Subject:Fw: BLVD Autoworks Car Wash Proposal Randy Stille Mayor City of St. Anthony Village 3301 Silver Lake RD, St. Anthony, MN 55418 612-782-3301 | www.savmn.com randy.stille@savmn.com From: Michael Wandell <mwandell@gmail.com> Sent: Monday, January 11, 2021 5:19 PM To: Randy Stille; Beth Comstock Wandell (comstock.beth@gmail.com) Subject: BLVD Autoworks Car Wash Proposal Caution: This email originated outside our organization; please use caution. Hi Randy, It's Mike Wandell. I'm not sure we've ever really formally met outside of National Night Out events where you end up talking to too many people to keep track of but we were on a Healing Circle call together a month or so ago so I'm assuming my name might ring a bell. I'm writing because I live on the south side of 27th Ave NE and the alley behind my house bumps up to the proposed Car Wash development location and I have several concerns about that empty lot becoming a car wash. I'm very concerned about the environmental and economic impact that it will have on our neighborhood and ultimately the community as a whole. Some broad stroke concerns I have are:  Air Pollution  Noise Pollution  Light Pollution  Water Runoff and Sewer Capacity  Traffic on 27th Ave and Kenzie Terrace  And of course how all the above will affect Property Values I believe I have heard that the proposal for this Car Wash is going to be sent back to the Planning Commission instead of being voted on tomorrow but I also have concerns as to how this was initially approved by the planning commission without taking many of my above concerns into consideration - let alone that idea building a car wash on that site means that there will always be a car wash in that location as the building won't be easily converted into another type of business which probably isn't in line with the City of Saint Anything Village's comprehensive growth plan. 147 2 My wife Beth and I would appreciate an opportunity to discuss the proposal with you before this goes to a vote. Is that something you'd be willing to do? Also, I'd like to reinforce the fact that I'm a concerned citizen and neighbor to this proposed development. I'm not someone that opposes change and/or growth and opportunity for SAV. In fact, I've been a resident of SAV since 2002 and am actively involved with several organizations - Current President of the WPPA, Board Member of the SANBE Foundation, Co-Navigator (leader) of the Voyager Organization along with Mark Kalar who you know from his days on the Planning Commission, Boosters Soccer Coach, Nourish 282 Volunteer and Fundraiser, the official unofficial mayor of SOSA (this title is quite an honor) and supporter of all things in Saint Anthony Village that I believe in, including helping out neighbors in need (example: Mark Sitarz and Richard Sonterre recently reached out to me asking if I could get a team together to help clear out significant yard overgrowth for a house on Edward Street where the homeowner is physically and financially unable to get his yard up to code). Oh, and I voted for you too if that counts for anything. Anyway, please let me know when a good time to talk might be. Thank you, Mike Wandell 2800 27th Avenue NE 651-402-6421 148 1 Charlie Yunker From:Barbara Gottfried <bgott3joy@gmail.com> Sent:Tuesday, January 12, 2021 1:15 PM To:Randy Stille; Tom Randle; Wendy Webster; Bernard Walker; Jan Jenson; Charlie Yunker; *SAPlanner Subject:Fwd: Car wash CUP on Kenzie Terrace Caution: This email originated outside our organization; please use caution. Dear Mayor and City Council, I am forwarding my letter that I sent to the planning commission. Please include this letter for tonight's meeting of January 12th at 7:00. ---------- Forwarded message --------- From: Barbara Gottfried <bgott3joy@gmail.com> Date: Thu, Jan 7, 2021, 12:33 PM Subject: Car wash CUP on Kenzie Terrace To: Marcey Westrick <Marcey.Westrick@savmn.com>, Meridith Socha <Meridith.Socha@savmn.com>, Thomas Kuykendall <Thomas.Kuykendall@savmn.com>, Dan Payne <dan.payne@savmn.com>, Brian Rude <Brian.Rude@savmn.com>, Corey Erickson <corey.erickson@savmn.com>, Paul Morita <paul.morita@savmn.com> Cc: Steve Grittman <planner@savmn.com> Dear Planning Commissioners, I live at the Kenzington Condos, a 55 + building, with my husband. Our home is facing and very near to the proposed car wash, as are 24 other condo units. I'm a cancer survivor of 6 years and I have asthma. My health is not as robust as a young person's. I'm sure that other seniors in our building of 150 units can say the same about their health. The idling car fumes from many cars much of the day, everyday, is my biggest concern. This will negatively impact our air quality. Most of every day, I won't be able to open any of my windows nor use my balcony because of my health. I'm asking you to please oppose the construction of this car wash for the health of the seniors in the Kenzington condos. (Many retired seniors are at home much of the day.) Thank you, Barbara Gottfried Unit #307 149 1 Charlie Yunker From:Randy Stille Sent:Tuesday, January 12, 2021 2:19 PM To:Charlie Yunker Subject:Fw: Online Form Submittal: Send Mayor Randy Stille an Email Randy Stille Mayor City of St. Anthony Village 3301 Silver Lake RD, St. Anthony, MN 55418 612-782-3301 | www.savmn.com randy.stille@savmn.com From: noreply@civicplus.com <noreply@civicplus.com> Sent: Tuesday, January 12, 2021 1:58 PM To: Randy Stille Subject: Online Form Submittal: Send Mayor Randy Stille an Email Caution: This email originated outside our organization; please use caution. Send Mayor Randy Stille an Email First Name Mike & Beth Last Name Wandell Address 2800 27th Ave NE City Saint Anthony Villag State MN Zip Code 55418 Contact preference By phone Phone Number 6514026421 Email Address mwandell@gmail.com Comments January 12, 2021 Dear Randy, 150 2 This is a more detailed and formal follow up to the email I sent directly to your email address (randy.stille@savmn.com) requesting the opportunity to speak with you regarding the BLVD Autoworks proposed Car Wash addition. My wife Beth and I are proud members of the Saint Anthony Village community. We are active in many volunteer organizations within the community and have done our best to try and make SAV a better place. I am the current President of the WPPA and a Co-Navigator (leader) in the Voyagers organization. This organization has recently helped with several situations that have directly helped the city and its residents. Beth volunteers for countless events and activities within the community as well. She is also a substitute teacher at Wilshire Park and was one of very few subs that was willing to work this fall, which helped keep the school open as long as possible. We have owned our home on 27th Avenue NE since 2002 and have been very happy with our little pocket in the SAV community (SOSA as it’s known). We are reaching out to you because we are very concerned about the planning commission’s approval of a Conditional Use Permit (CUP) for the proposed BLVD Carwash at 2701 Kenzie Terrace. In order for a Conditional Use Permit (CUP) to be given, the existing laws regarding impact of the project must be satisfied, specifically, in order for the CUP to be approved, The Council must find that the use is not detrimental to health, safety, and general welfare of persons residing or working in the vicinity or to the values of property in the vicinity. As owners of a single family home adjacent to the lot under consideration, we have the following concerns that have not been addressed and resolved by the St Anthony planning commission: 1. Location next to residential property 2. Health/safety/general welfare a. Air Pollution b. Noise Pollution c. Safety concerns 3. Water capacity and runoff management 4. Property values 1. LOCATION: The proposed carwash is in the middle of a residential area. Our single family homes, zoned R-1 would be adjacent to a carwash. Our neighbors to the South, the Kensington, is a multi-family housing building. As far as I am aware, there is no precedent in St. Anthony for a carwash adjacent to an R-1 and we feel that building a car was 151 3 is a poor choice for the use of the land considering the housing nearby. 2. HEALTH/SAFETY/GENERAL WELFARE A. Air Pollution. No environmental impact study was done by St. Anthony Planning staff regarding the air pollution resulting from idling cars. The plans submitted show a maximum capacity of 16 cars in staging---all presumably idling. Imagine having 16 cars idling outside your backyard for many hours a day while in your back yard. There is no evidence presented by the planning commission that assessed this impact. B. Noise Pollution. The plan and planning commission assessment does not include an analysis of decibel levels during operating hours of the car wash. a. Specific noise concerns from our perspective are cars idling, car radios (imagine the cacophony of multiple car radios playing different radio stations, including at least one with a very loud bass thumping), multiple vacuums in use, and likely most concerning is the constant noise of the blowers inside the car wash along with the added noise of the sprayers and other noises that emit from a carwash. There is lack of analysis, or demonstration that the proposal is compliant with existing city and state noise ordinances. We believe that it is the planning staff’s duty is to ensure that these noise elements have been studied and submitted and are compliant. b. Hours of operation are of concern, as the initial response of the planning commission was to expand the requested hours of the car wash from 7 am to 10 pm, 7 days per week. This neighborhood is quiet, so that currently, we can have conversations with neighbors outside, enjoy the sounds of birds and can sleep past 7 am on the weekends. Imagine living next to the noise identified above, 7 days per week, 15 hours per day. This is obviously detrimental to the health and general welfare of residents. 3. Water capacity and runoff management: There are millions and millions of dollars in upcoming proposed housing projects that will all need water. When the Lowry-Grove project was analyzed concerns were identified relative to insufficient infrastructure to accommodate the water needs of that project as well as the impact of water runoff by reduction of permeable surfaces. The projects on this end of the city, Kenzie Terrace and Stinson Parkway development, Development 65, and Trident Redevelopment Bremer site are under consideration for approval. We are concerned about potential impact on R-1 water volume and adequate volume for fire suppression. In addition, by changing the current permeable surface of the 152 4 vacant lot to non-permeable surfaces, we are concerned that the sewer infrastructure may be inadequate to manage the volume of water used by the carwash as well as the change to non-permeable surface. The planning commission has not addressed or resolved this concern. 4. Property values: As required per ordinance for a CUP request, the City Must demonstrate there is no adverse devaluation of the R-1 occupancies. Until all the proper analysis of these key factors has been done (Health/Safety/General Welfare), there is no way to make an assessment of what will happen to property values. Given the impacts identified above - air pollution, noise pollution, safety concerns and water capacity, it is hard to imagine that the value of our property will not be negatively impacted. This will not only impact the homes along the 27th Ave alley, but also houses even a block or two away. Certainly, the value of the Kenzington condos overlooking the carwash will be negatively impacted. From our perspective this proposed use will force depreciation of property values. That is unacceptable to the existing residents nearby who are paying considerable taxes to be a part of this community. The Council must find that the use is not detrimental to health, safety, and general welfare of persons residing or working in the vicinity or to the values of property in the vicinity. To date, none of this work has been done. This is a critical oversight. We believe the proposed use of the property is detrimental on all fronts. In consideration of the lack of due diligence by the Planning Commission to analyze and protect the public by examining data required by law, we believe that the Council must reject the conditional use permit. Additionally we are asking that this letter be put into the public record. Respectfully Submitted, J. Michael Wandell Elizabeth C. Wandell 2800 27th Ave NE St. Anthony, MN 55418 JMW- 651-402-6421 ECW – 612-710-2436 Email not displaying correctly? View it in your browser. 153 1 Charlie Yunker From:Paul McHugh <paulmchughmn@gmail.com> Sent:Tuesday, January 12, 2021 3:57 PM To:Charlie Yunker Subject:Public comment submissions re car wash CUP Attachments:Written opinion from MN realtor Ella Ritzman (email) - Commercial lot use permit.pdf; Kenzie Terrace Car Wash Noise Assessment, Stephen B. Platisha, P.E. (Professional Engineer).pdf Caution: This email originated outside our organization; please use caution. Hi Charlie, Please forward the attached to mayor and City council. Neither of these statements were written by me, but rather by professionals in real estate and noise assessment. Both deserve close examination by the council in evaluating the car wash CUP proposal. Thank you, Paul McHugh 154 Commercial lot use permit 1 message Ella Ritzman <ellampls@gmail.com>Mon, Jan 11, 2021 at 12:12 PM To: paulmchughmn@gmail.com Re: Proposed car wash at 2701 Kenzie Terrace  To Whom it may concern; A resident from 2601 Kenzie Terrace reached out to me today. He asked if I would give an opinion on the proposed development of a single lane car wash with 9 to 12 car vacuum stations abutting his residential senior living condominium unit.  I have not seen the property but from what Paul McHugh explained to me I imagine that these are some of the considerations that should be weighed: Air pollution from idling cars Noise pollution from vacuums, idling cars and the running carwash Noise from the customers (loud talking,auto music, mufflers, etc) Reduced value of residential property facing the car wash(potentially severe) Reduced quality of life for the residents being subject to all of the above I have never met Mr. McHugh. A fellow real estate broker gave him my name. Although the above observations are expressed by a real estate professional they seem to me to be obvious. -- Ella Ritzman/ Real Estate Broker MN 3233 19th Ave S  Minneapolis, MN 55407 Ritzman Realty 612-532-0738     155 156 157 158 159 1 Charlie Yunker From:noreply@civicplus.com Sent:Tuesday, January 12, 2021 4:37 PM To:Charlie Yunker Subject:Online Form Submittal: Public Comments for City Council Meetings Caution: This email originated outside our organization; please use caution. Public Comments for City Council Meetings First Name Tim Last Name Keane Phone Number 612-334-5015 Email Address tim.keane@kutakrock.com Address 60 South Sixth Street City Minneapolis State Minnesota Zip Code 55402 Public Comment Mayor Randy Stille and City Council Members City of St. Anthony Village 3301 Silver Lake Road NE St. Anthony, MN 55418-1667 RE: Conditional Use Permit Application for Car Wash located at 2701 Kenzie Terrace Dear Mayor and Council Members: This letter is offered on behalf of multiple residents of the Kensington Condominiums relating to the conditional use permit (CUP) application for a car wash located at 2701 Kenzie Terrace, St. Anthony Village, Minnesota (Property). The proposed car wash is located contiguous to the Kensington Condominiums (the Kensington) to the east, and single family residential to the north. The Kensington is a senior (55+) eligible building, occupied and owned by many residents 160 2 with aging conditions. The five-story Kensington has 19 balconies that will directly overlook the entry to the car wash. The granting of the CUP for this use is governed by the required findings set forth in SAV Code §152.243. The burden is on the applicant to prove, based upon facts in the record, that the use will conform to the stated standards and criteria for the issuance of the CUP. Roselawn Cemetery v. City of Roseville, Minn. App. 689 NW2d 254, 259. SAV Code §152.243(c)(4) provides: (3) The use will not be detrimental to the health, safety, or general welfare of persons residing or working in the vicinity or to the values of property in the vicinity; and Nearby residents of the Property have provided substantial testimony on the record directly bearing on this finding. Fact- based comments, concerns and testimony has addressed issues relating, but not limited to: • Adverse noise impacts from dryer blowers, vacuums, idling vehicles; • Adverse air quality impacts due to exhaust of idling vehicles, airborne particles, potentially affecting the health of adjacent senior residents; • Adverse impacts on adjacent residential property values. Additionally, sound expert, Stephen Platisha PE, submitted an assessment of noise impacts of the proposed car wash and nearby residential receptors, concluding that the car wash operations could likely cause a violation of state standards. Given the intensity of the car wash impacts of vehicle trips, noise, air pollution and safety concerns, this use is simply incompatible with existing surrounding neighboring residential land uses. The undisputed evidence in the record compels the conclusion that the proposed use for the Property would produce adverse impacts, detrimental to the health, safety, or general welfare to persons residing or working in the vicinity or to the values of property in the vicinity. Based upon the facts and the record, we respectfully submit that the CUP application must be denied. Sincerely, Timothy J. Keane Kutak Rock LLP Email not displaying correctly? View it in your browser. 161 162 163 164 165 166 167 THIS PAGE LEFT INTENTIONALLY BLANK 168 NORTHWEST ASSOCIATED CONSULTANTS, INC. __________________________________________________________________ 4150 Olson Memorial Highway, Ste. 320, Golden Valley, MN 55422 Telephone: 763.957.1100 Website: www.nacplanning.com MEMORANDUM TO: St. Anthony Village Planning Commission FROM: Stephen Grittman DATE: January 12, 2021 RE: St. Anthony Village – Planning Commission - Accessory Buildings FILE NO: 323.02 Accompanying this memorandum is a proposed mark-up of accessory building regulations found in the City’s Zoning Ordinance. The information is presented in two formats. The first is a two-column table which includes the existing code language from various sections relating to accessory buildings (column 2). For the existing text, current language is either retained or altered. Where it is to be altered (or deleted), you will see it stricken. Where it is to be kept intact, it is left unchanged, and copied into the proposed language in column 1. In column 1, staff has proposed new or changed language for those sections. This section includes changes to Definitions and various district requirements, with the bulk of the text being a complete update to the Accessory Building section of the code found in Section 152.176. In addition, there are a series of new regulations that are proposed to be added, including a shoreland notation for accessory buildings adjacent to Silver Lake. The second portion of the proposed material is a new table that would be added which is designed to consolidate the bulk of the dimensional standards applicable to (mostly) R-1 district requirements, and (partially) to other districts. The standards in this section primarily import the current regulations from other sections of the code, but a few are new and intended to be consistent with the manner in which they are addressed in current practice. We will plan to discuss this material under “Other Business” at the January meeting. If acceptable, the Planning Commission may move to call for a public hearing to formally consider these amendments as an ordinance amendment at the February Planning Commission meeting. 169 THIS PAGE LEFT INTENTIONALLY BLANK 170 Accessory Buildings Generally Existing Code Definitions: GARAGE: An accessory building (attached or detached) which is used, or can be used, to store passenger automobiles and light trucks, and which has a door opening which is six (6) feet or greater in width. ACCESSORY BUILDING (Recreational, Garden Shed, or Similar): An accessory building of no more than 200 square feet in floor area sheltering and accessory use such as recreation (such as a gazebo), tools, lawn and garden equipment, mechanical equipment (such as swimming pool equipment), or similar purposes. Such a building has a roof, and may or may not have solid walls. A. The following Accessory Buildings shall be allowed as permitted uses: 1. R-1, Single Family Zones: a. One (1) Attached Garage. b. Two Detached Accessory Buildings, provided only one is a garage or other building greater than 200 square feet. No more than two garages, (only one of which may be a detached garage), shall be allowed on any single family parcel. c. One (1) Recreational Structure or Garden Shed meeting the requirements of this ordinance. d. Recreational structures and uses, including swimming pools, hot tubs, play structures, animal shelters of less than 36 square feet in area, and landscape elements that do not provide any shelter for human occupancy, provided all other conditions and performance standards are met. a.e. Setback from principal building. Unless attached to and made a Definitions: GARAGE. An accessory building or portion of a principal building which is principally used for the storage of motor vehicles owned by occupants of the principal building. Garages cannot be larger than the principal structure or be more than 1,000 square feet in size in R-1, R-1A, and R-2 zoned property. 152.176 ACCESSORY BUILDINGS. (A) In yards. No detached accessory building may be located within any yard other than the rear yard, except that garages may be located in side yards. See Table (B) Minimum setback. The wall of an accessory buildings shall not be located less than five (5) feet from any property line and in no case shall any eave or other portion of any accessory building may be located within 3 feet of any property line, except as provided in division (L) below. See Table (C) Accessory buildings attached. If an accessory building is attached to the principal structure, it will be considered a part of the principal building and must comply with all setbacks and other requirements applicable to the principal building. See Table (D) Setback from principal building. Unless attached to and made a part of the principal building, no eave or other portion of an accessory building may be closer than 5 feet from any eave or other portion of a principal building, except as provided in division (L) below. (E) Design. All accessory buildings constructed after the construction of the principal building must be designed and constructed in a manner consistent with the design and general appearance of the principal building. Accessory buildings constructed primarily of canvas, plastic 171 part of the principal building, no eave or other portion of an accessory building may be closer than 5 feet from any eave or other portion of a principal building. f. Design. All accessory buildings constructed after the construction of the principal building must be designed and constructed in a manner consistent with the design and general appearance of the principal building. Accessory buildings constructed primarily of canvas, plastic fabric, or other similar non-permanent materials shall be prohibited. g. Commercial or Industrial Districts. No accessory building in a commercial or industrial district shall exceed the height of the principal building except by conditional use permit. h. Attached and Multi-family Buildings. Attached and multi- family buildings in the R3 and R4 districts are allowed one storage or maintenance building and one garden shed per complex, plus detached garage structures as needed. i. Building standards. All accessory buildings in excess of 200 square feet shall be constructed to the standards of the Minnesota State Building Code. The architectural appearance of accessory buildings should be visually compatible with the principal building relative to color, materials, and form. j. Accessory buildings without a Principal Building. No accessory building or structure shall be constructed on any lot prior to the time of construction of the principal building to which it is an fabric, or other similar non-permanent materials shall be prohibited. See Table (F). Height. (1) Residential Districts. A detached accessory building, accessory to a principal use located in a residence district shall not exceed the height of the principal building or fifteen (15) feet, whichever is less. The maximum height to the highest point on a roof shall not exceed twenty (20) feet. See Table (2) Commercial or Industrial Districts. No accessory building in a commercial or industrial district shall exceed the height of the principal building except by conditional use permit. (G). Number of buildings. A maximum of two individual accessory buildings per lot, including detached garages, shall be allowed in all zoning districts. Landscape features, such as statuary and the like; easily movable seasonal temporary structures not intended to remain erected for 12 months, such as party tents and the like; and backyard play equipment, such as swing sets, trampolines, slides, and the like, shall not count towards the number of permitted accessory buildings as provided in this division. (H). Size. (1) One- and Two-Family Dwellings. The maximum floor area of one accessory building or combination of two buildings in the R21, R1-A, and R2 districts shall not exceed 750 square feet in area or 80% of the area of the principal building, whichever is less. See Table (2) Attached and Multi-family Buildings. Attached and multi-family buildings in the R3 and R4 districts are allowed one storage or maintenance building and one garden shed per complex, plus detached garage structures as needed. (3) In all residential districts, one accessory building in addition to any detached garage may be permitted, except that it shall not exceed 120 square feet in area if a detached garage exists on the same lot. (I). Garage door openings. Garage door openings shall be limited in height to 8 feet 172 accessory unless authorized through an agreement as prepared by the City Attorney and approved by the City Council. k. Accessory Dwelling Units. Detached accessory buildings shall be prohibited from containing complete independent living facilities (accessory dwelling units), which would include permanent provisions for living, sleeping, eating, and sanitation. b. Permit Requirements. A zoning permit shall be required for all accessory buildings less than 120 square feet in area. All accessory buildings over 200 square feet shall require a building permit. A fee as determined from time to time by the City Council shall be required to process the permit. l. Accessory Dwelling Units. Detached accessory buildings shall be prohibited from containing complete independent living facilities (accessory dwelling units), which would include permanent provisions for living, sleeping, eating, and sanitation. m. Drainage and Utility Easements. No part of an accessory building shall extend into a drainage and utility easement or any required setback. as measured from the driveway apron at the door opening. See Table (J). Building standards. All accessory buildings in excess of 120 200 square feet shall be constructed to the standards of the Minnesota State Building Code. The architectural appearance of accessory buildings should be visually compatible with the principal building relative to color, materials, and form. (K). Accessory buildings without a Principal Building. No accessory building or structure shall be constructed on any lot prior to the time of construction of the principal building to which it is an accessory unless authorized through an agreement as prepared by the City Attorney and approved by the City Council. (L). Garage setback permit. A garage which will cover an area of no more than 576 square feet may be located within the side setbacks and/or rear setbacks if a setback permit has been issued for the garage under the following provisions of this section. (1) Application for a setback permit must be made in writing on forms provided by the City Manager and must be filed with the City Manager, together with a filing fee in the amount required under Chapter 33. The application must include a survey showing the proposed location of the building and the buildings on the property adjoining the setback in question. The application must also address the other matters to be considered by the Planning Commission and City Council, as set forth in division 79A St. Anthony - Land Usage (1) Application for a setback permit must be made in writing on forms provided by the City Manager and must be filed with the City Manager, together with a filing fee in the amount required under Chapter 33. The application must include a survey showing the proposed location of the building and the buildings on the property adjoining the setback in question. The application must also address the other matters to be considered by the Planning Commission and City Council, as set forth in division (B) above. The 173 permit application will be considered by the Planning Commission and City Council, and notice of the hearing will be given, all in the same manner as provided in § 152.243 for conditional use permits. After the hearing by the Planning Commission, the City Council will grant or deny the permit, stating its reasons for doing so. (2) In granting or denying the setback permit, the City Council will consider the proximity of the garage to any buildings on the adjoining property, the extent of vegetation or other screening on the subject property and the adjoining property, the effect of the garage on the light and visibility available to the adjoining property, modification to/or blockage of drainage ways, matters of fire safety, the existing garages on the adjoining property, the ability to locate garages elsewhere on the subject property, and any other matters which may be relevant to the degree of encroachment into the setback. (3) If a setback permit is granted, it will run with the title to the property for which it was granted so long as the garage for which it was granted continues to exist. If that building is destroyed or removed, the permit will automatically expire. (1993 Code, § 1650.02) Penalty, see § 10.99 (M). Driveways. Driveways shall be required for doorway openings meeting or exceeding 8 feet wide by 7 feet tall. All driveways must meet the standards as outlined in §152.179. (N). Accessory Dwelling Units. Detached accessory buildings shall be prohibited from containing complete independent living facilities (accessory dwelling units), which would include permanent provisions for living, sleeping, eating, and sanitation. (O), Drainage and Utility Easements. No part of an accessory building shall extend into a drainage and utility easement or any required setback. (P). Permit Requirements. A zoning permit shall be required for all accessory buildings less than 120 square feet in area. All accessory buildings over 120 square feet shall require a building 174 permit. A fee as determined from time to time by the City Council shall be required to process the permit. Landscape Elements Landscape elements, such as vegetation, gardens, statuary, and the like shall be allowed in all yards, provided other applicable regulations are met. Retaining walls shall be considered fences for the purposes of this ordinance. Trash Enclosures Trash enclosures, where allowed, shall be required to be constructed of materials that match the materials uses on the principal building exterior, and shall not be located in any yard closer to the public right of way than the principal structure. Detached Garage Materials (esp. MF Dwellings) Detached Garages accessory to multiple family dwellings, or any commercial or industrial use, shall be constructed of materials that match those used on the principal building. Recreational Structures and Uses. Gazebos, pool buildings, and other detached recreational structures shall meet the setbacks, size requirements, and other standards applicable to Garden Sheds. 175 District Performance Standards – Accessory Buildings and Uses. Unless otherwise specified in this section, all accessory buildings and/or uses in the R-1 District shall conform to the following requirements (except where noted as applying to other districts): Detached Garage Attached Garage Other Accessory Buildings, Recreational Structures, Garden Sheds Other Accessory Uses Front Yard Setback No closer than principal building, or 30 feet, whichever is greater 30 feet Not Allowed Not Allowed Side Yard Setback 5 feet 5 feet, with an aggregate total of 15 feet on two sides Not Allowed Not Allowed Side Yard Setback adjacent to public street 20 feet 20 feet 20 feet 20 feet Rear Yard Setback from private property 30 feet 5 feet 5 feet 5 feet Rear Yard Setback from Alley 5 feet 30 feet 5 feet 5 feet Rear Yard Setback from Public Street 30 feet 30 feet 30 feet 30 feet Maximum Square Feet 750 square feet, or 80% of ground floor area of principal building, whichever is less No greater than ground floor area of principal building 200 square feet NA Maximum Height – R-1, R-1A, R-2 15 feet to average roof height, and no more than 20 feet overall No greater than roof height of principal structure 15 feet to peak roof height NA Maximum Height – R-3, R-4 30 feet 30 feet 15 feet to peak roof height NA Maximum Height – C, I Districts No accessory building in a commercial or industrial district shall exceed the height of the principal building except by conditional use permit. No accessory building in a commercial or industrial district shall exceed the height of the principal building except by conditional use permit. 15 feet to peak roof height NA 176