My WebLink
|
Help
|
About
|
Sign Out
Home
2018.02.05 CC Packet
Hugo
>
City Council
>
City Council Agenda/Packets
>
2018 CC Packets
>
2018.02.05 CC Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2019 1:50:52 PM
Creation date
2/1/2018 2:52:46 PM
Metadata
Fields
Template:
City Council
Document Type
Agenda/Packets
Meeting Date
2/5/2018
Meeting Type
Regular
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2040 Water Supply System <br />Proposed Water System <br />Improvements <br />The City of Hugo's Water CIP includes a number of improvements to <br />ensure adequate water storage and supply. These improvements are <br />shown in Map 9-5. <br />The City's maximum day demand is expected to increase to 6,200 gpm <br />(8.95 MGD) by the year 2040. The system's existing firm capacity is <br />4,225 gpm (6.08 MGD). Assuming that future production wells will <br />have a production capacity of approximately 1,200 gpm and that the <br />maximum day demand is supplied over 20 hours, three additional <br />wells will be required by 2040. A well siting study will be required to <br />determine the locations of these future wells. <br />The City's average day demand is expected to increase to 2,400 <br />gpm (3.44 MGD) by the year 2040. The City's total existing storage <br />capacity is 2.0 MG. The City plans to construct a new 1.5 MG water <br />tower that will be located beside existing Well No. 6 in the future. Once <br />this new water tower is constructed, the existing Tower No. 2 will be <br />taken out of service, leaving the City's total future storage capacity at <br />3.0 MG. Based on a supply and storage analysis through the year <br />2040, this future storage capacity will satisfy the City's storage and fire <br />fighting requirements through that time. <br />To serve the eastern portion of the City that is currently outside of <br />the City's 2040 MUSA, the trunk water distribution system will need <br />to be extended to the east, in addition to the construction of supply <br />and storage infrastructures within that part of the City. Distribution, <br />supply, and storage requirements will be dependent on the expected <br />population and land use of the areas where service is extended. <br />)GO 2040 COMPREHENSIVE PLAN UPDATE <br />DRAFT Dec14-17 <br />for review only <br />COMPREHENSIVE WATER SUPPLY 222 <br />AND DISTRIBUITION PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.