Laserfiche WebLink
From:Rachel Juba <br />To:Emily Weber <br />Subject:FW: CUP Submittal - Lake Access Lot <br />Date:Monday, May 20, 2019 1:09:37 PM <br />Attachments:image3da4e4.PNG <br />  <br />  <br />From: Stephanie Hatten [mailto:SHatten@wsbeng.com]  <br />Sent: Thursday, May 16, 2019 10:12 AM <br />To: Rachel Juba <RJuba@ci.hugo.mn.us>; Mark Erichson <MErichson@wsbeng.com> <br />Subject: RE: CUP Submittal - Lake Access Lot <br />  <br />Hi Rachel, <br />  <br />I’ve reviewed the site and below are some comments: <br />  <br />New impervious being added is 1410 square feet. No stormwater management is required. <br />The site also does not trigger an erosion control permit, however, I would still recommend <br />they add in the plans a double row of silt fence adjacent to the wetland. <br />No floodplain fill is shown for the RCWD floodplain elevation, so no RCWD floodplain permit is <br />needed. <br />The new parking lot is shown to intersect the FEMA floodplain line work, however, the actual <br />elevation of 913.0 shown from the contours does not intersect the new impervious. <br />Therefore, there is no fill within the FEMA floodplain as well. <br />  <br />Let me know if you have any questions. Thanks! <br />Stephanie <br />  <br />Stephanie Hatten, CFM <br />Graduate Engineer <br />763.762.2828 (o) | 612.360.1284 (m) <br />WSB | wsbeng.com <br />This email, and any files transmitted with it, is confidential and is intended solely <br />for the use of the addressee. If you are not the addressee, please delete this email <br />from your system. Any use of this email by unintended recipients is strictly prohibited. <br />WSB does not accept liability for any errors or omissions which arise as a result <br />