Laserfiche WebLink
(10 <br />-�X933.2 <br />T- <br />1 934 - o-------- > <br />-} - <br />934.0 9 <br />932.0 ------- <br />/ 0 <br />/ , ' ! 933.9 - ' - �1� MATCH 933.80 - <br />/ r 93 <br />/ CV <br />cxo / 30 <br />/ 932.75 933.5 933.40 <br />/ 931.91 932.90 -IR <br />------ - - � - - 932.25 i <br />M ° <br />OVERFLOW PATH <br />(10 <br />w <br />ry <br />i----= <br />rn <br />=__- <br />932.7p- <br />933.00 <br />k9`32.6 <br />932.80 <br />® <br />0.. <br />.20 <br />933.50 <br />933.10 <br />0aA 931.85 i 932.85 0 / <br />932.75 ��� X93 1 ' 932.90 <br />I <br />931.77� ° <br />- ° o °° <br />933.02 / <br />X ---__ 3 l / <br />_ - � \ <br />CA- - CAW�LA CA I 0 932.75 Xco <br />932.62 / <br />932.25 2.1 % 31-75 _ 0.5% p-�OVV X l <br />_ <br />/ l I - -I ' cc <br />931.61 <br />931.55 �J o - _ 931.65 _ - - _ 0.5%- p=LOVy 932.70 i 7 <br />_ 932: t0- _ _ ° 932.66 <br />o.i _ <br />�) 932.06 x 931 931.60 _ _ _ <br />M 932.23 __ ___ <br />CA 931.23 932 52 " �o <br />+ �`' 931.49 ( 931.51 932.37 9 <br />co 931.87 - _ _ X 1� `°p° p� co p w <br />� OVERFLOW PATH w cN <br />932.49 x_W ___- CA � \\ ��� o w/CA X <br />° ° w X \ � <br />------ __ CD <br />�932.03 °� 32.65 ° 932.30 \ i V 932.60 x __� /--_� C� <br />931.70 I ° \ \ w = �_ _ Z _Z <br />p \ 932.8 0 <br />9 9 1. �4 � � 932.3 \ rn � b � � zz <br />J <br />+ 931.65 932.27 p ° \ 932.72 �a�" X <br />+ S�8 931�625 ° ° A 932.67 W m <br />.6� - 932.51 <br />�zj� _ x ����_, 931.62 AV �` �. <br />Ln <br />W 931.21 932.9 ° 932.78 \ o _ W <br />------------ - _ _ 931.15 931.577 931.90 �� \ 932.78 \ °° `S� m 'J o <br />F// RESTAURANT-N, 932.51X931.53 �i co <br />X 2 931.09 931.53 c° \ <br />931.50 ° 6 �� -)- i CA <br />A 9341 �i x Gq R <br />931.34 - 931.50 w� X i x \ DEN <br />-0- - f FFE 933.0 Q <br />�� °i o CA 932.39 <br />19 <br />w <br />I o °° 932.78 \ \RS`3S X <br />93 - <br />- _ _ +9�9 � 931.10 � i <br />0 931.66 93'L 14 - ? , 932.78 <br />�� - ------ -�__ 931.70 p 0 931.16 \\ 932.9 <br />932.9 <br />SS <br />° S ti 932.24 g34 <br />w - _ 932.25 '� _ 9 <br />931.62 302 - 931.15 931 932 - _ _ �C�r ��\� \ ° 933 <br />\ - 931.58 - - - 931.4 6 <br />- - 93,1.05 929 <br />-_ 32.5 0 <br />- - _ 2 - DECK o ° x <br />` \�N � � \ 932.9 �� � � ° p � <br />`/� _ ° <br />\ \ 92 �y W �< \ "' \ \ cxo \�� ` \ 932.15 \m 932.5 <br />wL� 28 3 g g v M�43 v VA w �� `�� \ �° o <br />\ ---- 929.93- - - - - - - - <br />\\� <br />wL \ \ % \\rn _ \� X <br />�� 931 0 -- <br />A `° X <br />v 930.38 v ° v v 931.4 \ VA EVEN �\ \ 932.09 ( / <br />\ 932.9 \ FUTURE T \ \ \ <br />\ \ \ <br />v 932.4, CENTER <br />931.4 <br />y <br />off� � v � �� '_A �`, 931.9 � � � c9 \ �� -_,: <br />EGG LAKE 928.1 <br />���.A `� 931.4� ��� 932.9 N \ CI6 <br />p <br />\\�9� v \ TUBE w��� ���� 932.65 <br />OHW-926.62(NAVD88) � � <br />v DE n <br />- \ <br />+ �.�� / CA/ 933.0 <br />\ ,.10wLwL \ 4 .a✓ �/ 933.0 <br />LWL- <br />\\�'' N , / <br />\ x <br />932.65,,I� <br />NI <br />iN,Ndo <br />x <br />UNDER DECK INFILTRATION BASIN \\\ 932.4 \ \ / �� / / X 9� 2 <br />BOTTOM 929.6 �'< \ t 932.4 �� ` X <br />OVERFLOW 930.8 \`N\ 931.9 / / / /� W <br />HWL 930.9 I \� - \ N'\ 43`� <br />928.1 <br />PHASE I GRADING PLAN <br />1"=20' <br />INFILTRATION CONSTRUCTION ( 1 <br />(TYP) C-503 <br />EDGE OF ICE MEASURED ON 12-05-19- <br />ICE ELEVATION = OWHL <br />EDGE OF DELINEATED WETLAND <br />HWL 928.5 <br />NINII <br />933.�`,`\ <br />\ \ / <br />< <� IN / NORTH INFILTRATION BASIN \ <br />\ BOTTOM 929.7 <br />933.0 \ OVERFLOW 931.2 <br />\ 3� \ J HWL 931.3 <br />� 3 / <br />\ \\ N, IN \\ !v`; / LA <br />\ V \ ry <br />w� \ <br />\ \ IN.NN <br />/ <br />NN IN NI <br />�9� \� <br />IN <br />�S7 N <br />CP c° <br />I <br />933.3 <br />GRADING NOTES <br />1. VERIFY ALL FIELD CONDITIONS AND UTILITY LOCATIONS PRIOR TO EXCAVATION/CONSTRUCTION. IF ANY DISCREPANCIES OR UNKNOWN <br />UTILITIES ARE FOUND THAT IMPACT DESIGN OR IMPAIR CONSTRUCTION, THE ENGINEER AND OWNER SHOULD BE IMMEDIATELY <br />NOTIFIED. <br />2. ALL WORK TO COMPLY WITH CURRENT MINNESOTA DEPARTMENT OF TRANSPORTATION (MNDOT) STANDARD SPECIFICATIONS FOR <br />CONSTRUCTION UNLESS NOTED. <br />3. FOLLOW ALL RECOMMENDATIONS PRESENTED IN GEOTECHNICAL EVALUATION REPORT PREPARED BY NTI, EXCEPT AS MODIFIED IN <br />THESE NOTES. <br />4. ALL NON -GRANULAR SOILS, AND TOPSOIL SHALL BE REMOVED FROM WITHIN THE PROPOSED BUILDING PAD. A GEOTECHNICAL <br />ENGINEER OR THEIR DESIGNATED REPRESENTATIVE SHALL OBSERVE THE PROJECT EXCAVATIONS TO VERIFY THAT UNSUITABLE <br />MATERIALS HAVE BEEN PROPERLY REMOVED FROM PROPOSED STRUCTURAL AREAS, THAT ADEQUATE BEARING SUPPORT IS PROVIDED <br />BY THE EXPOSED SOILS AND THAT STRUCTURAL FILL IS PLACED APPROPRIATELY. THE EXPOSED SOIL AT THE BASE OF FOOTINGS OR <br />THICKENED SLAB SHALL BE COMPACTED TO 98 PERCENT PROCTOR DRY DENSITY (ASTM D698). <br />5. ON -SITE GRANULAR SOIL IS GENERALLY SUITABLE FOR STRUCTURAL FILL. SILTY OR ORGANIC SOILS SHALL NOT BE USED FOR <br />STRUCTURAL FILL. PLACEMENT OF STRUCTURAL FILL SHALL BE OBSERVED AND TESTED BY AN EXPERIENCED TECHNICIAN OR <br />ENGINEER TO VERIFY THAT PROPER COMPACTION HAS BEEN ACHIEVED. STRUCTURAL FILL SHALL BE MOISTURE CONDITIONED (DRIED <br />OR WETTED) AS APPROPRIATE PRIOR TO PLACEMENT. MOISTURE CONDITIONED ENGINEERED FILL SHALL BE PLACED AND COMPACTED <br />IN LOOSE LIFTS OF 8 INCHES OR LESS. EACH LIFT OF FILL SHOULD BE COMPACTED BY LARGE VIBRATORY EQUIPMENT UNTIL THE <br />IN -PLACE SOIL DENSITY IS EQUAL TO OR GREATER THAN THE CRITERIA ESTABLISHED WITHIN THE FOLLOWING TABULATION. <br />TYPE OF CONSTRUCTION COMPACTION CRITERIA MOISTURE CONTENT VARIANCE FROM <br />OPTIMUM (% RESPECTIVE PROCTOR) <br />-3 TO +3% FOR SAND AND GRAVEL SOILS <br />NON -ENGINEERED FILL (GREEN SPACE) 95 <3% FOR CLAY SOILS <br />-3 TO +3% FOR SAND AND GRAVEL SOILS <br />ENGINEERED FILL BELOW FOUNDATIONS 98 <3% FOR CLAY SOILS <br />-3 TO +3% FOR SAND AND GRAVEL SOILS <br />ENGINEERED FILL BELOW FLOOR SLABS 98 <3% FOR CLAY SOILS <br />6. PARKING LOT SUBGRADE SHALL NOT BE COMPACTED. EXCAVATED TO SUBGRADE ELEVATION WITH TRACKED EQUIPMENT THAT <br />IMPARTS MINIMAL LOAD. DO NOT EXCAVATED WORK IN SUBGRADE WHEN WET OR WHEN PRECIPITATION IS IMMINENT. <br />7. SIDEWALLS SHALL BE RETAINED BENCHED OR SLOPED TO PROVIDE SAFE WORKING CONDITIONS. THE CONTRACTOR IS SOLELY <br />RESPONSIBLE FOR ASSESSING THE STABILITY OF AND EXECUTING PROJECT EXCAVATIONS USING SAFE METHODS. THE CONTRACTOR <br />IS ALSO RESPONSIBLE FOR NAMING THE "COMPETENT INDIVIDUAL" AS PER SUBPART P OF 29 CFR 1926.6 (FEDERAL REGISTER - OSHA). <br />8. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF SOIL, UTILITY AND BUILDING RETENTION SYSTEMS. <br />9. PAVEMENT: SEE DETAILS SHEET C-502 FOR BITUMINOUS AND CONCRETE PAVEMENT SECTION. <br />10. CONCRETE MIX NO.3F52 (MNDOT 2461) SHALL BE USED FOR HAND PLACED FORMED CURB AND GUTTER, MEDIANS, DRIVEWAYS, CROSS <br />GUTTERS, SIDEWALKS, PEDESTRIAN RAMPS AND MEDIANS. CONCRETE MIX NO.3F32, MNDOT SPECIFICATION 2461) SHALL BE USED FOR <br />AN EXTRUSION MACHINE PLACEMENT OF CONCRETE. IN THE PRODUCTION OF CONCRETE, AN AIR ENTRAINING AGENT SHALL BE ADDED <br />TO THE MIX ACCORDING TO MNDOT 2461.4. <br />11. FORM COATING MATERIAL SHALL MEET MNDOT 3902. <br />12. CONCRETE INSTALLATION SHALL CONFORM WITH MNDOT 2531. <br />13. SITE CONCRETE FINISHING - CONCRETE SHALL BE STRUCK TRUE TO CROSS SECTION AS SHOWN ON THE PLANS. NO ADDITIONAL <br />WATER MAY BE ADDED TO AID IN THE FINISHING PROCESS. A LIGHT BROOM FINISH WILL BE REQUIRED AT RIGHT ANGLES TO THE <br />CENTER LINE ON ALL CONCRETE WORK UNLESS DIRECTED OTHERWISE. ALL EXPOSED EDGES AND JOINTS IN CURB,GUTTER, SIDEWALK <br />AND STEPS SHALL BE ROUNDED WITH A SUITABLE EDGING TOOL. BEFORE FINAL FINISHING, THE CONTRACTOR SHALL CHECK THE <br />CONCRETE WITH A TEN (10) FOOT STEEL STRAIGHT EDGE TO ENSURE THERE IS NO VARIATION GREATER THAN 3/16"FROM THE <br />STRAIGHT EDGE ON TANGENT LINES OR GRADES. IF DEVIATIONS GREATER THAN 3/16" ARE FOUND THE WORK WILL BE CONSIDERED AS <br />UNACCEPTABLE AND WILL BE REQUIRED TO BE REMOVED AND REPLACED AT NO EXPENSE TO THE OWNER. <br />14. CONCRETE CURING SHALL BE PERFORMED BY APPLYING A MEMBRANE CURING COMPOUND (TYPE 2, WHITE PIGMENTED, MNDOT 3754) <br />TO THE EXPOSED SURFACE OF THE CONCRETE WITHIN ONE (1)HOUR AFTER FINISHING THE CONCRETE SURFACES. WHEN THE FORMS <br />ARE REMOVED IN LESS THAN 72 HOURS AFTER PLACING THE CONCRETE, THE CURING COMPOUND SHALL BE APPLIED IMMEDIATELY TO <br />THE EXPOSED SURFACES. THE RATE OF APPLICATION OF CURING COMPOUND SHALL BE 150 SQUARE FEET PER GALLON. THE <br />COMPOUND SHALL APPEAR AS WHITE AS A SHEET OF PAPER AFTER APPLICATION ON THE CONCRETE SURFACE. <br />15. PREFORMED EXPANSION JOINTS SHALL MEET MNDOT 3702, AND SHALL BE PROVIDED AT THE FOLLOWING LOCATIONS: AT THE <br />BEGINNING AND END OF ALL CURB AND GUTTER RADII. WHERE NEW CONCRETE SURROUNDS, ADJOINS, OR ABUTS ANY EXISTING FIXED <br />OBJECTS SUCH AS FIRE HYDRANTS, BUILDING FOUNDATIONS, CONCRETE DRIVEWAYS, SIDEWALKS, AND OTHER RIGID STRUCTURES. <br />AFTER EACH LOAD OF CONCRETE WHEN PLACING CURB AND EVERY 100 FEET WHEN PLACING SIDEWALK. CONTRACTION JOINTS WILL <br />NOT BE SEALED BUT WILL BE REQUIRED AT A SPACING OF 10 FEET ON CURB AND GUTTER AND ON SIDEWALK CONSTRUCTION AS <br />SHOWN ON THE PLAN. CONTRACTION JOINTS WILL BE CUT TO A DEPTH 1/3 THE THICKNESS OF THE CONCRETE, SURFACE AND BACK OF <br />ALL CURBS. CONTRACTION JOINTS SHALL BE PLACED SO THAT NO SLAB IS LARGER THAN 100 SQUARE FEET IN AREA. THE CONTRACTOR <br />IS RESPONSIBLE FOR CONSTRUCTING CONTRACTION JOINTS THAT PREVENT CONCRETE FROM CRACKING AT OTHER LOCATIONS. <br />16. CONCRETE TESTING INCLUDING SLUMP, AIR ENTRAINMENT, TEMPERATURE AND COMPRESSIVE STRENGTH SHALL BE PERFORMED ON <br />THE FIRST LOAD OF THE DAY FOR ALL CONCRETE POURS OF AT LEAST 4 CUBIC YARDS. AN ADDITIONAL TEST SHALL BE PERFORMED <br />FOR EACH 100 CUBIC YARDS OR PORTION THEREOF. <br />a <br />Know what's below. 20 60 <br />CaII before you dig. I SCALE IN FEET <br />ARCHITECTURAL <br />CONSORTIUM L.L.C. <br />901 NORTH THIRD STREET, <br />SUITE 220 <br />MINNEAPOLIS, MN 55401 <br />612-436-4030 <br />PROJECT <br />CATTLE HOUSE <br />RESTAURANT & <br />EVENT CENTER <br />HUGO, MINNESOTA <br />SHEET INDEX <br />PLANNED UNIT <br />DEVELOPMENT <br />(PUD), <br />PRELIMINARY PLAT, <br />SITE PLAN REVIEW <br />02/17/2020 <br />ISSUE DATE <br />AMENDED CITY APPLICATION 02/20/2020 <br />CITY COMMENTS 03/02/2020 <br />CITY COMMENTS 1 04/10/2020 <br />D E S I G N <br />Civil Engineering I Landscape Architecture I Construction Services <br />901 N 3rd STREET, SUITE 120 <br />MINNEAPOLIS, MN 55401 <br />p 612.260.7980 www.eIanIab.com <br />f 612.260.7990 <br />C E R T I FICATION <br />I hereby certify that this plan was prepared by me, <br />or under my direct supervision and that I am a <br />duly Licensed Professio eer under the <br />laws of the stateyQf 11 A. `0\ <br />NU `wC, <br />G <br />ONS� <br />Stephen M. Johnston DATE <br />REGISTRATION NO. 18914 01/17/2020 <br />SHEET <br />PHASE <br />GRADING PLAN <br />C-202 <br />PROJECT NO. <br />ARC19010 <br />