Laserfiche WebLink
=RFLOW IS % OF THE CURB <br />K HEIGHT <br />=RFLOW AT TOP OF <br />fER ASSEMBLY <br />.ISTING CURB, PLATE, BOX, <br />ID GRATE <br />.TER ASSEMBLY DIAMETER, 6" <br />I -GRADE 10" AT LOW POINT <br />3H-FLOW FABRIC <br />NU 1 E5: <br />1. REPLACE INLET GRATE UPON COMPLETE INSTALLATION OF INLET PROTECTION FABRIC. <br />2. CONTRACTOR SHALL REMOVE ALL ACCUMULATED SEDIMENT AND DEBRIS FROM THE SURFACE OF THE SYSTEM <br />AFTER EACH STORM EVENT AND AT THE COMPLETION OF THE CONTRACT. <br />3. REFERENCE APPLE VALLEY STANDARD PLATE ER04C. <br />CURB INLET FILTER <br />N T S <br />30' FROM EDGE OF ROAD <br />TO FRONT OF SPEED BUMP <br />35' R <br />Q <br />0 <br />I <br />O <br />C N J <br />C <br />0 <br />w <br />TO CONSTRUCTION <br />Z <br />I <br />AREA <br />NA <br />l l <br />l <br />l <br />co <br />I <br />p <br />z <br />n <br />C� <br />PLAN 35' R <br />z <br />6" MIN CRUSHED STONE <br />TO CONSTRUCTION AREA <br />U) <br />X <br />I <br />EXISTING <br />75' MINIMUM <br />UNDISTURBED <br />FINISHED <br />GRADE 1 <br />GEOTEXTILE FILTER 4" HIGH, 18" WIDE ROADWAY <br />F-FABRIC I I rSPEED BUMP <br />PROFILE <br />NOTES: <br />1. PROVIDE APPROPRIATE TRANSITION BETWEEN STABILIZED CONSTRUCTION ENTRANCE AND UNDISTURBED <br />ROADWAY. <br />2. THE ENTRANCE SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOWING OF SEDIMENT <br />ONTO UNDISTURBED ROADWAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH ADDITIONAL STONE OR ADDING <br />STONE TO THE LENGTH OF THE ENTRANCE. <br />3. REPAIR AND CLEANOUT MEASURES USED TO TRAP SEDIMENT. <br />4. ALL SEDIMENT SPILLED, DROPPED, WASHED, OR TRACKED ONTO UNDISTURBED ROADWAY SHALL BE REMOVED AS <br />DIRECTED BY THE ENGINEER. <br />5. FINAL LOCATION AND INSTALLATION SHALL BE COORDINATED WITH THE CITY PRIOR TO CONSTRUCTION ACTIVITIES. <br />6. CRUSHED STONE SHALL BE 1-1/2" DIA. CLOSE GRADED, AND IN ACCORDANCE TO MNDOT SECTION 2118. <br />STABILIZED CONSTRUCTION ACCESS <br />N T S <br />'B' TAMP THE TRENCH FULL OF SOIL. <br />SECURE WITH ROW OF STAPLES, <br />10" SPACING, 4" DOWN FROM <br />TRENCH <br />rr r <br />r r r r <br />rr <br />r ®o r r r <br />rrY xr rr \ <br />'C' OVERLAP: BURY UPPER END <br />OF LOWER STRIP AS IN 'A' <br />AND'B'. OVERLAP END OF rr <br />TOP STRIP 4" AND STAPLE. r r r r <br />r <br />'D' EROSION STOP: FOLD OF MATTING <br />BURIED IN SILT TRENCH AND <br />TAMPED. DOUBLEROW OF <br />STAPLES. <br />PLACE STAPLES 2 FEET APART <br />TO KEEP MATTING FIRMLY <br />PRESSED TO SOIL. <br />EROSION BLANKET <br />'A' BURY THE TOP END OF THE <br />MATTING IN A TRENCH 4" OR <br />MORE IN DEPTH <br />NOTE: <br />1. PLACE STAPLES 2 FEET APART TO <br />KEEP MATTING FIRMLY PRESSED TO <br />SOIL. <br />TYPICAL STAPLE #8 <br />GAUGE WIRE <br />EXISTING GROUND <br />SURFACE <br />00 <br />ILTER FABRIC AS SPECIFIED <br />ILLER AS SPECIFIED <br />FILL UPSTREAM BASE EDGE WITH <br />2" OF DIRT OR COMPOST TO <br />EMBED ROLL. <br />DIRECTION OF FLOW <br />WOODEN STAKES 1/2"X2"X16" MIN. PLACED 10' O.C. <br />WHEN INSTALLED ON GROUND. IF INSTALLED ON <br />PVMT. PROVIDE SANDBAGS BEHIND AND ON TOP AT <br />MIN. 10' O.C. <br />NOTE: <br />1. COMPOST FILTER LOGS (BIO ROLLS) SHALL BE FILTREXX EROSION CONTROL SOXX OR APPROVED EQUAL. <br />2. COMPOST FILLER TO BE MADE FROM A COMPOST BLEND 30%-40% GRADE 2 (SPEC 3890) AND 60%-70% <br />PARTIALLY DECOMPOSED WOOD CHIPS, PER MNDOT SPEC 3897. <br />3. FILTER FABRIC SHALL BE GEOTEXTILE KNITTED MATERIAL WITH MAX. OPENINGS OF 3/811 <br />. <br />4. IF MULTIPLE ROLLS NEEDED, OVERLAP BY MIN. 12" AT ENDS AND STAKE. <br />5. SILT SHALL BE REMOVED ONCE IT REACHES 80% OF THE HEIGHT OF THE ROLL OR AS DEEMED NECESSARY <br />BY SITE CONTRACTOR TO MAINTAIN PROPER FUNCTION. <br />SEDIMENT BIO-ROLL / COMPOST FILTER LOG <br />N T S <br />SUPPORT NET: 12 GAUGE 4" x 4" <br />WIRE HOOKED ONTO - <br />PREFORMED CHANNELS ON <br />POSTS AS SPECIFIED. <br />EXISTING GROUND <br />SURFACE <br />FILTER FABRIC WITH WIRE SUPPORT NET <br />AS SPECIFIED. <br />METAL POST AS <br />SPECIFIED. <br />FILTER FABRIC AS SPECIFIED SECURE <br />TO WIRE SUPPORT NET WITH METAL <br />CLIPS 12"O.C. <br />IIIANCHOR FABRIC SOIL, TAMP BACKFH ILL <br />CARRY WIRE SUPPORT =NET <br />DOWN INTO TRENCH <br />�z <br />N � <br />SEDIMENT FENCE <br />N T S <br />DIRECTION OF FLOW <br />tom` ��. \ <br />METAL POSTS 8'-0" O.C. <br />MAX. <br />(C�017RO <br />S�Otei <br />o7 m Oo M D21 <br />Civil Engineering • Surveying • Landscape Architecture <br />4931 W. 35th Street, Suite 200 <br />St. Louis Park, MN 55416 <br />civilsitegroup.com 612-615-0060 <br />0 <br />w <br />0 <br />0 <br />3 <br />2 <br />V <br />J <br />J <br />N <br />Z A <br />W L0 <br />2 2 <br />Z <br />Q <br />Q j <br />z <br />W z <br />♦Q � <br />V 00 <br />O <br />O <br />0 <br />0 <br />I HEREBY CERTIFY THAT THIS PLAN, <br />SPECIFICATION, OR REPORT WAS <br />PREPARED BY ME OR UNDER MY DIRECT <br />SUPERVISION AND THAT I AM A DULY <br />LICENSED PROFESSIONAL ENGINEER <br />UNDER THE LAWS OF THE STATE OF <br />MINNESOTA. <br />- MaTthew R. Pavek <br />DATE 02.21.2020 LICENSE NO. 44263 <br />ISSUE/SUBMITTAL SUMMARY <br />DRAWN BY: KT, ND, JD REVIEWED BY: PS <br />PROJECT NUMBER: 19296 <br />REVISION SUMMARY <br />DATE I DESCRIPTION <br />SWPPP - DETAILS <br />N T S <br />SW1 02 <br />4/17/2020 14:10:43 1 © COPYRIGHT CIVIL SITE GROUP I <br />