My WebLink
|
Help
|
About
|
Sign Out
Home
2021.02.01 CC Packet
Hugo
>
City Council
>
City Council Agenda/Packets
>
2021 CC Packets
>
2021.02.01 CC Packet
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2021 10:43:03 AM
Creation date
2/1/2021 10:40:55 AM
Metadata
Fields
Template:
City Council
Document Type
Agenda/Packets
Meeting Date
2/1/2021
Meeting Type
Regular
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. CONTRACTOR TO VERIFY ALL CONDITIONS AND REPORT DISCREPANCIES TO THE <br />ARCHITECT OR OWNER, PRIOR TO BEGINNING CONSTRUCTION. <br />2. MECHANICAL AND ELECTRICAL INFORMATION SHOWN IS INTENDED ONLY TO <br />COMMUNICATE DESIGN INTENT. REFER TO MECHANICAL AND ELECTRICAL <br />NARRATIVES FOR DETAILED INFORMATION. NOTIFY ARCHITECT/ENGINEER OF ANY <br />DISCREPANCIES NOTED PRIOR TO COMMENCEMENT OF WORK. <br />3. COORDINATE ALL CEILING MOUNTED EQUIPMENT SUPPORTS, DEVICE LOCATIONS, <br />CLEARANCES, ETC. WITH EQUIPMENT INSTALLERS AND SUPPLIERS PRIOR TO <br />INSTALLATION. <br />4. ACOUSTICAL PANEL CEILING GRIDS OR PANELS SHALL BE CENTERED IN ROOMS <br />UNLESS OTHERWISE NOTED OR DIMENSIONED. <br />5. ALL CEILING MOUNTED ITEMS (LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS, <br />ETC.) SHALL BE CENTERED IN ACOUSTICAL CEILING PANELS OR GYPSUM BOARD <br />SOFFITS UNLESS OTHERWISE NOTED OR DIMENSIONED. <br />6. SPACE LIGHT FIXTURES EVENLY IN ROOMS, BAYS, SPACES, ETC. AND CENTER <br />BETWEEN EXPOSED STRUCTURAL ELEMENTS WHERE APPROPRIATE. <br />7. DIMENSIONS TO CEILING-INSTALLED ITEMS ARE TO CENTERLINE OF FIXTURE OR <br />EQUIPMENT UNLESS NOTED OTHERWISE. <br />8. LOCATE CONTROL JOINTS IN GYPSUM BOARD CEILINGS, SOFFITS, BULKHEADS, AND <br />FASCIAS AS INDICATED ON DRAWINGS OR AS SPECIFIED AND TO ALIGN WITH THOSE <br />IN WALLS BELOW. VERIFY PROPOSED LAYOUT WITH ARCHITECT PRIOR TO <br />INSTALLATION. <br />9. PAINT ALL CONDUITS, DUCTWORK, SUPPORTS, HANGERS, ETC. THAT WILL REMAIN <br />EXPOSED TO VIEW. MATCH COLOR INDICATED FOR STRUCTURE (PNT-1) UNLESS <br />NOTED OTHERWISE. <br />10. REFER TO EXTERIOR ELEVATIONS (SHEET a3.0) FOR ANY ADDITIONAL LIGHTING OR <br />POWER REQUIREMENTS ON THE BUILDING FACE. <br />CEILING PLAN GENERAL NOTES <br />CEILING PLAN - SYMBOL KEY <br />NO WORK IN THIS AREA <br />EXISTING PARTITIONS TO REMAIN <br />NEW PARTITIONS, SEE PARTITION TYPES <br />TYP <br />1 <br />TYP <br />2 <br />TYP <br />2 <br />TYP <br />2 <br />TYP <br />1 <br />3 <br />4 <br />4 <br />5 <br />5 <br />53 <br />3 <br />4 <br />4 4 <br />6 <br />3 <br />3 <br />12 <br />6 <br />12 <br />6 <br />126 <br />77 <br />4 <br />8 <br />2 <br />TYP <br />12 <br />10 10 <br />TYP <br />6 <br />4 <br />11 11 <br />3 <br />3 <br />TYP <br />13 <br />KEY PLAN <br />DRAWING NUMBER <br />DRAWING TITLE <br />CLIENT <br />I hereby certify that this drawing was prepared by <br />me or under my direct supervision and that I am a <br />duly registered architect under the laws of the <br />State of Minnesota. <br />Title: XXXX <br />Registration Number: XXXX <br />Date: XXXX <br />By: <br />Title: XXXX <br />a r c h i t e c t s <br />4201 cedar avenue so. -minneapolis, MN 55407 <br />tel. (612) 904-1332 -fax (612) 904-7366 <br />Hagen, Christensen & McIlwain <br />CIVIL ENGINEER <br />STRUCTURAL ENGINEER <br />MECHANICAL / ELECTRICAL ENGINEER <br />N O T F O R C O N S T R U C T IO N <br />178 E 9TH STREET <br />SUITE 200 <br />SAINT PAUL, MN 55101 <br />6120 EARLE BROWN DRIVE <br />SUITE 700 <br />MINNEAPOLIS, MN 55430 <br />7705 BUSH LAKE ROAD <br />EDINA, MN 55439 <br />1/14/2021 3:52:33 PMC:\Users\Josh\Documents\2066_CITY OF HUGO LIONS PARK _ CENTRAL MODEL _2019_HCMarch.rvta9.1 <br />5524 UPPER 146TH STREET N <br />HUGO, MN 55038 <br />LIONS PARK CIVIC <br />PAVILION <br />REFLECTED CEILING <br />PLANS <br />KEYNOTES - REFLECTED CEILING PLAN <br />Number Description <br />1 SUSPENDED T&G WOOD CEILING ASSEMBLY WITH PERFORATED SOUND <br />ABSORBANT PANELS THROUGHOUT - STAIN AND SEAL <br />2 LINEAR LED LIGHT FIXTURES <br />3 GYP. BD. CEILING/ SOFFIT ASSEMBLY, PAINT. PROVIDE 6" LED RECESSED CAN LIGHT <br />FIXTURES <br />4 2'x2' ACOUSTICAL CEILING TILE AND GRID ASSEMBLY. PROVIDE 6" LED RECESSED <br />CAN LIGHT FIXTURES AND/OR BASKET FIXTURES AS SHOWN <br />5 NO CEILING, OPEN TO STRUCTURAL ABOVE, PAINT. PROVIDE 1x4/ 1x8 SUSPEBDED <br />LINEAR LED LIGHT FIXTURES <br />6 EXTERIOR WOOD BEAD BOARD SOFFIT. PROVIDE EXTERIOR GRADE LED LIGHT <br />FIXTURES <br />7 LINEAR COVED LIGHT FIXTURE <br />8 RECESSED TRACK FOR MANUAL SECURITY SIDE SLIDING WALL ASSEMBLY <br />10 GALVANIZED STEEL BEAM TO SUPPORT ROOF OVERHANG - WRAP IN WOOD, ALL <br />SIDES <br />11 PTD. GYP BOARD SOFFIT - MECHANICAL CHASES INTO LOW ROOF AREA <br />12 EXTERIOR METAL PANEL SOFFIT. PROVIDE EXTERIOR GRADE LED LIGHT FIXTURES <br />WHERE SHOWN ON RCP LAYOUT <br />13 DECORATIVE LED EXTERIOR PENDANT LIGHTING <br />1/8" = 1'-0"a9.1 <br />1 REFLECTED CEILING PLAN <br />NORTH <br />REVISION DATE DESCRIPTION
The URL can be used to link to this page
Your browser does not support the video tag.