Laserfiche WebLink
[14] Public Utility Easementper Doc. No. 3172032 <br />N89°40'02"E 1320.77Wire FenceEdge of WoodsGravel DriveWETLAND F16,078 SFWETLAND G16,910 SFWETLAND E67,678 SFWETLAND D23774 SFLIMITS OFCONSTRUCTIONLIMITS OFCONSTRUCTIONLIMITS OFCONSTRUCTIONLIMITS OFCONSTRUCTIONLIMITS OFCONSTRUCTIONLIMITS OFCONSTRUCTIONLIMITS OFCONSTRUCTIONBLOCK 1 <br />B <br />L <br />O <br />C <br />K <br /> <br /> <br />2 <br />BLOCK 8 <br />B <br />L <br />O <br />C <br />K <br /> <br /> <br />3 <br />BLOCK 9 <br />B <br />L <br />O <br />C <br />K <br /> <br /> <br />9 <br />OUTLOTB(224 <br />,692 <br /> SF <br />)OUTLOTE(29,702 SF)OUTLOTA(83 <br />,216 <br /> SF <br />)OUTLOTA(83,216 SF)100-YR HWL=915.54BASIN 3NWL=915.00OUTLET EL=915.00100-YR HWL=916.41BASIN 4NWL=913.00OUTLET EL=913.00OUTLET EOF=914.50100-YR HWL=914.93EOFEOFEOFEOF914.50EOF35'35'EOFEOF <br />EOFEXIST. 42" MET COUNCILSANITARY SEWERHYD & GV,TYP.HYD &GV,TYP.HYD & GV,TYP.24"WATERMAIN8" DIPWATERMAIN420 LF 8"PVC SDR35SAN @ 0.40%SAN MH 6RE=915.70IE(N)=907.25IE(W/S)=907.35177 LF 8"PVC SDR35SAN @ 0.40%SAN MH 7RE=917.55IE(NE)=907.82IE(SW)=907.92243 LF 8"PVC SDR35SAN @ 0.40%SAN MH 8RE=918.20IE(NE)=908.89SAN MH 31RE=917.80IE(N)=909.00IE(W)=909.10114 LF 8"PVC SDR35SAN @ 0.40%SAN MH 32RE=918.40IE(E)=909.56399 LF 8"PVC SDR35SAN @ 0.40%SAN MH 30RE=919.00IE(NE)=907.30IE(S)=907.40241 LF 8"PVC SDR35SAN @ 0.40%SAN MH 6ARE=916.50IE(N)=908.31CONNECT TOEXISTING 24" DIPWATERMAINEX 16" DIPWATERMAIN8" DIPWATERMAIN24" DIPWATERMAINHYD &GV,TYP.22.5° BEND90° BEND11.25° BEND22.5° BEND22.5° BEND90° BEND24X24X8 TEECONNECTION(1)45° BEND(1)11.5° BEND90° BEND90° BEND4" PVC SAN. (TYP)1" PVC WAT. (TYP)4" PVC SAN. (TYP)1" PVC WAT. (TYP)24X24X8 TEECONNECTION4" PVC SAN. (TYP)1" PVC WAT. (TYP)[14] Public Utility Easement <br />per Doc. No. 3172032Water TowerGravel DriveLIMITS OFCONSTRUCTIONLIMITS OFCONSTRUCTIONEXIST. 42" MET COUNCIL <br />SANITARY SEWER <br />HYD & GV,TYP.SAN MH 32RE=918.40IE(E)=909.56CONNECT TOEXISTING 24" DIPWATERMAINEX 16" DIPWATERMAINEX 24" DIPWATERMAINEX 8" PVC SANSERVICEEX SAN MH 46RE=919.70EX IE(N/S)=905.3390° BENDCivil Engineering Surveying Landscape Architecture4931 W. 35th Street, Suite 200St. Louis Park, MN 55416civilsitegroup.com 612-615-0060COPYRIGHT CIVIL SITE GROUP INC.cPROJECT <br />P <br />R <br />E <br />L <br />I <br />M <br />I <br />N <br />A <br />R <br />Y <br />: <br />N <br />O <br />T <br /> <br />F <br />O <br />R <br />C <br />O <br />N <br />S <br />T <br />R <br />U <br />C <br />T <br />I <br />O <br />NISSUE/SUBMITTAL SUMMARYDATEDESCRIPTION............PROJECT NUMBER:1830112/13/20REVISED CITY SUBMITTAL12/23/20REVISED CITY SUBMITTAL1/5/20WATERSHED SUBMITTAL1/26/21....12/4/20CITY SUBMITTALDRAWN BY:REVIEWED BY:mp, ktmp, kt..............202044263Matthew R. PavekLICENSE NO.DATEI HEREBY CERTIFY THAT THIS PLAN,SPECIFICATION, OR REPORT WASPREPARED BY ME OR UNDER MY DIRECTSUPERVISION AND THAT I AM A DULYLICENSED PROFESSIONAL ENGINEERUNDER THE LAWS OF THE STATE OFMINNESOTA.12.13.20The Meadows at Hugo <br />Hugo, MN <br />6001 Glenwood Avenue, Golden Valley, MN 55422 <br />Golden Valley Land CompanyCITY RESUBMITTALREVISION SUMMARYDATEDESCRIPTIONC4.1UTILITY PLAN(SAN WATER)............UTILITY LEGEND:01" = 50'-0"50'-0"25'-0"NKnow what'sbelow.before you dig.CallRCATCH BASINGATE VALVE AND VALVE BOXSANITARY SEWERSTORM SEWERWATER MAINPROPOSED FIRE HYDRANTMANHOLEFES AND RIP RAPGENERAL UTILITY NOTES:1.ALL EXISTING UTILITY LOCATIONS SHOWN ARE APPROXIMATE. CONTACT "GOPHER STATE ONECALL" (651-454-0002 OR 800-252-1166) FOR UTILITY LOCATIONS, 48 HOURS PRIOR TOCONSTRUCTION. THE CONTRACTOR SHALL REPAIR OR REPLACE ANY UTILITIES THAT AREDAMAGED DURING CONSTRUCTION AT NO COST TO THE OWNER.2. SEE SITE PLAN FOR HORIZONTAL DIMENSIONS AND LAYOUT.3. CONTRACTOR SHALL FIELD VERIFY LOCATION AND ELEVATION OF EXISTING UTILITIES ANDTOPOGRAPHIC FEATURES PRIOR TO CONSTRUCTION. THE CONTRACTOR SHALL IMMEDIATELYNOTIFY THE ENGINEER OF DISCREPANCIES OR VARIATIONS FROM THE PLANS.4. UTILITY INSTALLATION SHALL CONFORM TO THE CURRENT EDITION OF "STANDARDSPECIFICATIONS FOR WATER MAIN AND SERVICE LINE INSTALLATION" AND "SANITARY SEWER ANDSTORM SEWER INSTALLATION" AS PREPARED BY THE CITY ENGINEERS ASSOCIATION OFMINNESOTA (CEAM), AND SHALL CONFORM WITH THE REQUIREMENTS OF THE CITY AND THEPROJECT SPECIFICATIONS.5. CASTINGS SHALL BE SALVAGED FROM STRUCTURE REMOVALS AND RE-USED OR PLACED AT THEDIRECTION OF THE OWNER.6. ALL WATER PIPE SHALL BE CLASS 52 DUCTILE IRON PIPE (DIP) AWWA C151, ASME B16.4, AWWA C110, AWWA C153 UNLESS OTHERWISE NOTED.7. ALL SANITARY SEWER SHALL BE SDR 26 POLYVINYL CHLORIDE (PVC) ASTM D3034 & F679, OR SCH40 ASTM D1785, 2665, ASTM F794, 1866) UNLESS OTHERWISE NOTED.8. ALL STORM SEWER PIPE SHALL BE HDPE ASTM F714 & F2306 WITH ASTM D3212 SPEC FITTINGS UNLESS OTHERWISE NOTED.9. PIPE LENGTHS SHOWN ARE FROM CENTER TO CENTER OF STRUCTURE OR TO END OF FLAREDEND SECTION.10. UTILITIES ON THE PLAN ARE SHOWN TO WITHIN 5' OF THE BUILDING FOOTPRINT. THECONTRACTOR IS ULTIMATELY RESPONSIBLE FOR THE FINAL CONNECTION TO BUILDING LINES.COORDINATE WITH ARCHITECTURAL AND MECHANICAL PLANS.11. CATCH BASINS AND MANHOLES IN PAVED AREAS SHALL BE SUMPED 0.04 FEET. ALL CATCHBASINS IN GUTTERS SHALL BE SUMPED 0.15 FEET PER DETAILS. RIM ELEVATIONS SHOWN ONTHIS PLAN DO NOT REFLECT SUMPED ELEVATIONS.12. ALL FIRE HYDRANTS SHALL BE LOCATED 5 FEET BEHIND BACK OF CURB UNLESS OTHERWISENOTED.13. HYDRANT TYPE, VALVE, AND CONNECTION SHALL BE IN ACCORDANCE WITH CITY REQUIREMENTS.HYDRANT EXTENSIONS ARE INCIDENTAL.14. A MINIMUM OF 8 FEET OF COVER IS REQUIRED OVER ALL WATERMAIN, UNLESS OTHERWISENOTED. EXTRA DEPTH MAY BE REQUIRED TO MAINTAIN A MINIMUM OF 18" VERTICALSEPARATION TO SANITARY OR STORM SEWER LINES. EXTRA DEPTH WATERMAIN IS INCIDENTAL.15. A MINIMUM OF 18 INCHES OF VERTICAL SEPARATION AND 10 FEET OF HORIZONTAL SEPARATIONIS REQUIRED FOR ALL UTILITIES, UNLESS OTHERWISE NOTED.16. ALL CONNECTIONS TO EXISTING UTILITIES SHALL BE IN ACCORDANCE WITH CITY STANDARDS ANDCOORDINATED WITH THE CITY PRIOR TO CONSTRUCTION.17.CONNECTIONS TO EXISTING STRUCTURES SHALL BE CORE-DRILLED.18. COORDINATE LOCATIONS AND SIZES OF SERVICE CONNECTIONS WITH THE MECHANICALDRAWINGS.19. COORDINATE INSTALLATION AND SCHEDULING OF THE INSTALLATION OF UTILITIES WITHADJACENT CONTRACTORS AND CITY STAFF.20. ALL STREET REPAIRS AND PATCHING SHALL BE PERFORMED PER THE REQUIREMENTS OF THECITY. ALL PAVEMENT CONNECTIONS SHALL BE SAWCUT. ALL TRAFFIC CONTROLS SHALL BEPROVIDED BY THE CONTRACTOR AND SHALL BE ESTABLISHED PER THE REQUIREMENTS OF THEMINNESOTA MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MMUTCD) AND THE CITY. THISSHALL INCLUDE BUT NOT BE LIMITED TO SIGNAGE, BARRICADES, FLASHERS, AND FLAGGERS ASNEEDED. ALL PUBLIC STREETS SHALL BE OPEN TO TRAFFIC AT ALL TIMES. NO ROAD CLOSURESSHALL BE PERMITTED WITHOUT APPROVAL BY THE CITY.21. ALL STRUCTURES, PUBLIC AND PRIVATE, SHALL BE ADJUSTED TO PROPOSED GRADES WHEREREQUIRED. THE REQUIREMENTS OF ALL OWNERS MUST BE COMPLIED WITH. STRUCTURES BEINGRESET TO PAVED AREAS MUST MEET OWNERS REQUIREMENTS FOR TRAFFIC LOADING.22. CONTRACTOR SHALL COORDINATE ALL WORK WITH PRIVATE UTILITY COMPANIES.23. CONTRACTOR SHALL COORDINATE CONNECTION OF IRRIGATION SERVICE TO UTILITIES.COORDINATE THE INSTALLATION OF IRRIGATION SLEEVES NECESSARY AS TO NOT IMPACTINSTALLATION OF UTILITIES.24. CONTRACTOR SHALL MAINTAIN AS-BUILT PLANS THROUGHOUT CONSTRUCTION AND SUBMITTHESE PLANS TO ENGINEER UPON COMPLETION OF WORK.25.ALL JOINTS AND CONNECTIONS IN STORM SEWER SYSTEM SHALL BE GASTIGHT OR WATERTIGHT.APPROVED RESILIENT RUBBER JOINTS MUST BE USED TO MAKE WATERTIGHT CONNECTIONS TOMANHOLES, CATCHBASINS, OR OTHER STRUCTURES.26.ALL PORTIONS OF THE STORM SEWER SYSTEM LOCATED WITHIN 10 FEET OF THE BUILDING ORWATER SERVICE LINE MUST BE TESTED IN ACCORDANCE WITH MN RULES, CHAPTER 4714,SECTION 1109.0.MATCH LINE <br />CITY OF HUGO UTILITY NOTES:1.CONTRACTOR TO COORDINATE THE EXISTING UTILITY INFRASTRUCTUREALONG EXISTING PORTIONS OF FINALE WITH ALL UTILITY COMPANIES WHO MAYBE INVOLVED. RELOCATION, REMOVAL OR PROTECTION OF EXISTING UTILITIESMUST BE AGREED UPON AND COORDINATED PRIOR TO CONSTRUCTION.2.ACCESS TO KEYSTONE PLACE (ADJACENT PROPERTY) SHALL BE MAINTAINEDDURING UTILITY CONNECTIONS. COORDINATE PLAN WITH CITY PRIOR TOCONSTRUCTION.3.CONTRACTOR TO INSTALL 4" OF RIGID INSULATION PER DETAILS ON ALLSANITARY SEWER PIPES WITH LESS THAN 8' OF COVER.RCWD UTILITY NOTES:1.DEVELOPER MUST PROVIDE AN AS-BUILT SURVEY OF THE INVERT ELEVATIONSOF ALL CULVERTS EXTENDING INTO JD3 (DRAINAGE DITCH).1.1.OS 61, FES 60