Ms. Rachel Juba <br />February 5, 2021 <br />Page 2 <br />stormwater discharge location would be at the northwest corner to the existing ditch that runs <br />west to an area drain near the intersection of Everest Ave N and 122"d St N. <br />a. Recommend placing stormwater BMP in the northwest corner of the site at the lowest <br />part of the site and near the desired discharge location rather than the high point of <br />the site as shown. <br />8. Site will be required to provide a water quality treatment volume of 1.1 inches x total area of <br />new or reconstructed impervious. <br />a. If volume reduction practices (infiltration/water reuse) can be used on site, these will <br />be required. <br />b. If volume reduction practices are not feasible, any other BMP type may be used but <br />the TP Factor listed in RCWD Table C1 must be applied to calculate the total water <br />quality treatment volume required. <br />c. Area not treated for phosphorus may not exceed 15% of all new or reconstructed <br />impervious surface. For all untreated surface, TSS must be removed to the maximum <br />extent practicable <br />9. Peak stormwater runoff rates for the 100-year 24-hour rainfall event is limited to 0.1 cfs/acre. <br />a. Peak stormwater runoff rates for the proposed project must not exceed existing rates <br />for the 2-year and 10-year 24-hour rainfall events using Atlas 14 rainfall depths. <br />10. The lowest building opening must be 3' above the 100-year HWL and 1' above the EOF of an <br />adjacent BMP. <br />11. Storm sewer should be designed for a 10-year rainfall event. <br />12. Applicant will be required to demonstrate compliance with wetland bounce/inundation <br />allowances outlined in RCWD Rule C.8 for the onsite wetland. <br />13. Site is outside of the 100-year floodplain — no floodplain requirements. <br />14. Applicant will be required to show compliance with all other RCWD and City of Hugo rules. <br />15. A wetland delineation on the parcel has been approved. The roadway and lot configuration <br />appear to avoid potential wetland impacts. <br />Thank you for the opportunity to provide comments on this project. If you have any questions, <br />please do not hesitate to contact me at 651-286-8463. <br />Sincerely, <br />WSB <br />.' F"e�� <br />Mark Erichson, PE <br />City Engineer <br />cc: Scott Anderson, Public Works Director (email only) <br />Liz Finnegan, Senior Engineering Technician (email only) <br />C:\Users\rachel.juba\AppData\Local\Microsoft\Windows\I NetCache\Content.Outlook\O7PY7DSU\ <br />LTR-rjuba-Drengson Sketch Plan - 20210205 (002).docx <br />